STAR STOP SHALLOW WELL JET PUMP

Similar documents
SHALLOW WELL JET PUMP

LAWN SPRINKLER, IRRIGATION PUMP

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

PRE-PLUMBED SEWAGE SYSTEM

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS

AUTOMATIC SUBMERSIBLE UTILITY PUMP

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

GARDEN HOSE UTILITY PUMP

Installation Instructions and Parts Manual CPJ SERIES JET PUMPS. Shallow Well Jet Pumps. Convertible Jet Pumps. Ejectors (Purchase separately)

HALLMARK INDUSTRIES INC

2 Wire Plus Ground 3 Wire Plus Ground IL0655

END SUCTION CENTRIFUGAL PUMPS

Potable Water Convertible Jet Pumps

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

END SUCTION CENTRIFUGAL PUMPS

SUNC3000 / Item #40885

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

ESE Series Cast Iron Sewage Pumps

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

Matala. VersiFlow Series. Instruction and Maintenance Manual

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

StormPro BA Series Sump Pump

MODELS 125M/B, 150M/B and 200M/B

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

MODELS 125M/B, 150M/B and 200M/B

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

OWNERS GUIDE TO INSTALLATION AND OPERATION OF 1/2-5 HP, 5, 7, 10, 15, 19 & 27 GPM 4 SUBMERSIBLE PUMPS

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual

Owner s Manual GLASSLINED PUMP TANK

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

Installation Manual DIAPHRAGM WELL TANK

GeyserMax-Flow Series

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

STEP-BY-STEP INSTALLATION GUIDE

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

OWNER S MANUAL CONVERTIBLE JET PUMP

M-3025CB-AV Fuel Pump

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Self-Priming Centrifugal Pumps

Illumifalls Patio Pond

Installation Manual. Q Series Quadplex Grinder Systems. Contents

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

SUBMERSIBLE MINI-PUMP

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

Material required for drilled well application (indoor use only)

Artesian2 Owners Manual

PRODUCT NUMBERING SYSTEM SERIES PHASE. 1: Single Phase 3: Three Phase

StormPro BCV400 Sewage Ejector Pump

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

MH Series - Horizontal Multistage Pump OWNER'S MANUAL

Installation & Operating Manual

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

IMPORTANT SAFETY INSTRUCTIONS

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

TPAK Series COOLANT PUMP

S2n1 PREASSEMBLED SUMP PUMP SYSTEM

Sealless Centrifugal Canned Motor Pumps

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

Installation Operation Parts

Powerful & Intelligent Submersible Pumps

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

TPHK Series Immersible Pump

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source.

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

SPECIFICATIONS: Tank Size: 80 gallons PUMP RPMs: 1050 CFM: 40PSI; 90 PSI Max Pressure: 150 PSI Thermal overload protection

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

2460 / 2472 / Series Simplex Grinder Systems

TPHK Series Immersible Pump

Transcription:

SHALLOW WELL JET PUMP MODEL SJ0S / HP STAR starwatersystems.com STOP Questions, problems, missing parts? Before returning to your retailer, call our customer service department at -800-7-0, 7:0 a.m. - p.m., EST, Monday - Friday. ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Español p. 8 FW66 A

TABLE OF CONTENTS Product Specifications... Safety Information... Package Contents... Preparation... General Pump Information... Well to Pump Connection...6 Pump to Tank Connection...9 Tank to House Connection...0 Pump Electrical Connections... Pump Priming and Startup... Care and Maintenance... Warranty... Troubleshooting...6 Replacement Parts...7 PRODUCT SPECIFICATIONS Power supply required... volts or 0 volts, 60 Hz (Pump is set by the factory to run on 0 volts) Maximum water temperature...77 F ( C) Individual branch circuit required... Amp minimum Discharge connection... in. NPT connection...-/ in. NPT Motor duty... Continuous duty with enforced air cooling and thermal overload protection Pressure switch... Preset at 0 PSI on / 0 PSI off Water depth rating... Maximum of ft. MODEL HP VOLTAGE HZ AMP Capacity - U.S. Gallons per Minute at Discharge 0 PSI FT. FT. FT. SJ0S / /0 60 7.8/.6 9. 6.. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product. SAFETY INFORMATION DANGER electrical shock hazard. Always disconnect power source before performing any work on or near the or its connected load. If the power disconnect point is out-of-sight, lock it in the open position and tag it to prevent unexpected application of power. Failure to do so could result in fatal electrical shock. electrical shock hazard. Do not handle the pump with wet hands or when standing in water as fatal electrical shock could occur. Disconnect main power before handling unit for ANY REASON! RISK OF ELECTRIC SHOCK. These pumps have not been investigated for use in swimming pool areas. WARNING Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA). Replace damaged or worn wiring cord immediately. Never use an extension cord. Do not kink power cable and never allow the cable to come in contact with oil, grease, hot surfaces, or chemicals. Wire to correct supply voltage. See nameplate and wiring diagrams and check voltage of power supply. Unit must be securely and adequately electrically grounded. This can be accomplished by wiring the unit to a ground metal-clad raceway system or by using a separate ground wire connected to the bare metal of the frame or other suitable means. Do not disassemble the housing. This pump has no repairable internal parts and disassembling may cause leakage or dangerous electrical wiring issues. Make certain the electrical power source is adequate for the requirements of the pump. Never use an extension cord with this pump. CHEMICAL ALERT. This product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm. HAZARDOUS PRESSURE ALERT. Install pressure relief valve in discharge pipe. Release all pressure on system before working on any component. explosion alert Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in flammable and/or explosive atmospheres.

SAFETY INFORMATION GENERAL PUMP INFORMATION CAUTION This pump is not to be used for irrigation or water systems. Protect the power cable from coming in contact with sharp objects. Do not run pump dry. Pump and plumbing must be full of water before startup. Do not pump water which contains sand, mud, silt, or debris. INJURY MAY RESULT Be careful when touching the exterior of an operating. It may be hot enough to be painful or cause injury. Typical Pump Setup. Shallow well jet pumps are designed for use where the suction lift is ft. or less. They can be used with drilled or cased wells.. Jet pumps can also be used with dug wells, driven wells or with cisterns or lakes. Lift ft. Max Lift Discharge to Home Support -/ in. Water Level Check Valve Foot Valve Discharge to Home / or in. Discharge / or in. Discharge IL0 PACKAGE CONTENTS Description Quantity Pump ft. Max Support Water Level -/ in. PREPARATION Before beginning installation of product, make sure all parts are present. If any part is missing or damaged, do not attempt to assemble the product. Compare parts to package contents list. Estimated Installation Time: hours. Tools Required for New Installation (not included): pipe wrench, pliers, Phillips screwdriver, pipe clamp, -step PVC glue system (primer and sealer), thread tape, tire gauge or compressor Drive Point Ventilation - Ventilation and drainage must be provided to prevent damage to the from heat and moisture. Freezing - Pump and all piping must be protected from freezing. If freezing weather is forecast, drain pump or remove completely from the system. Water Supply - The water source must be able to supply enough water to satisfy the capacity of pump and water needs. See performance chart on page. Lift - lift is the vertical distance from the lowest level of the water to the pump intake. Pump will move water as long as it is within vertical ft. of the water source. Horizontal Distance - The horizontal distance is the horizontal measurement between pump suction and the water source. This distance may affect the ability of pump to operate. If it is more than 00 ft., call the manufacturer for assistance: -800-7-0. IL7 Parts Required for New Installation (not included): well seal, -/ in. to in. male PVC adapter (), -/ in. male PVC adapter, in. male PVC adapter, -/ in. foot valve, -/ in. PVC pipe and couplings, in. PVC pipe and couplings, -/ in. PVC elbow, in. PVC elbow, in. discharge tee, galvanized bushing, pressure gauge (optional) or pipe plug, -/ in. union (optional), in. union (optional), electrical wire, electrical wire strain relief, in. x in. x in. tee, / in. x / in. slip coupling, in. x in. slip adapter, in. x / in. slip adapter

GENERAL PUMP INFORMATION WELL TO PUMP CONNECTION (SUCTION PIPE) And Fittings. Use galvanized steel or NSF PW Schedule 0 PVC pipe and fittings. This material is designed for water pressure and will seal against air and water under pressure. Do not use DWV fittings, as these are designed for drains without pressure and will not seal properly. CAUTION: The entire system must be air and water tight for efficient operation and to maintain prime. Wire Size: The wire size is determined by the distance from the power source to the pump and the horsepower rating of the. See the wire chart on page for proper wire size. WELL TO PUMP CONNECTION (SUCTION PIPE) CAUTION: Dry-fit entire assembly to ensure proper fit before gluing or taping parts. -/ in. in. NPT Discharge. Using a -step PVC system (not included), attach enough -/ in. PVC pipe and couplings (not included) to the adapter to equal the depth of the well, minus ft.. Before sliding the pipe assembly into the well, firmly clamp the assembly with a pipe clamp (not included) to prevent the assembly from sliding down into the well. ft. maximum Water level -/ in. PVC pipe clamp CAUTION: Follow all proper gluing procedures as specified by the glue manufacturer. Always glue in a vertical direction whenever possible to prevent glue from dripping inside pipe or fittings CAUTION: Use pipe tape and pipe paste compound on all male threads. Tighten with wrench to a snug fit and add another / turn to ensure proper seal.. Thread -/ in. male PVC adapter (not included) into a -/ in. foot valve (not included). Hand tighten, then tighten / turn with a pipe wrench. -/ in. male PVC adapter. Remove the pipe clamp and slide a well seal (not included) over the PVC pipe and onto the well casing. The PVC pipe should extend approximately in. above the top of the well seal, depending on the height of the pump. NOTE: Do not let the assembly slide down into the well. Tighten the well seal until the rubber gaskets are tight against the well casing and the PVC pipe. Well Seal Approx. in. ft. minimum -/ in. Foot valve. Using a -step PVC system, attach a -/ in. PVC elbow (not included) onto the rigid PVC pipe extending from the well seal. -/ in. PVC Elbow 6 7

WELL TO PUMP CONNECTION (SUCTION PIPE) PUMP TO TANK CONNECTION (DISCHARGE PIPE) 6. Wrap thread tape (not included) around the threads of a -/ in. male PVC adapter (not included). Thread the adapter into the -/ in. opening in the front of pump. 6 -/ in. male PVC adapter. Wrap thread tape around threads of a in. discharge tee (not included). Using a pipe wrench, thread the in. discharge tee into the in. opening in the top of pump. in. Discharge Tee 7. An optional -/ in. union (not included) is recommended for easy connection and disconnection. 7 -/ in. Union. Install a in. MPT x / in. FPT galvanized bushing and (optional) pressure gauge (both not included), or a pipe plug (not included). Do not tighten, as you will prime pump later at this location. Pressure Gauge or Plug with Bushing 8. Using -step PVC system, attach -/ in. PVC pipe and couplings as needed to connect the -/ in. male PVC adapter to the -/ in. PVC elbow attached to the top of the well pipe in Step. 8 -/ in. PVC. Wrap thread tape around the threads of a in. male PVC adapter (not included) and thread the adapter into the discharge tee. in. male PVC adapter NOTE: Be sure the pipe slopes downward slightly from pump to the well to prevent air pockets. Well. Continue with in. fittings and pipe to the pressure tank. An optional in. union (not included) is recommended for easy connection and disconnection. To pressure tank in. union 8 9

TANK TO HOUSE CONNECTION TANK TO HOUSE CONNECTION. Most pressure tanks will have a in. inlet elbow on the bottom. Connect to this elbow with a in. MPT x in. slip (glue) adapter and short piece of pipe. Adapter. Attach the pipe from the pump to the tee installed in Step. Then, from the tee, install / in. pipe and optional shut off valve (not included) to connect tee to house plumbing. Shut off valve From Pump To House Plumbing. Attach a in. elbow (not included) to the pipe. Elbow 6. IMPORTANT: Air pressure in the tank must be PSI lower than the cut-in of the pressure switch. Pump has a 0/0 PSI pressure switch, so tank pressure must be set at 8 PSI. Locate the air valve/stem on the tank and check pressure with a tire gauge (not included). If air needs to be removed, press down on valve to bleed off air. Use a tire pump or air compressor to add air if needed. 6 Air Valve/Stem Tank Tire gauge. Attach a in. pipe (not included) to the elbow and a in. x / in. reducer bushing (not included) to the pipe.. Attach a / in. pipe (not included) to the reducer bushing. Install an optional / in. union (not included) and continue with pipe and / in. x / in. x / in. tee (not included). 68 in. x / in. Reducer Bushing Tee in. Union / in. pipe Reducer bushing PUMP ELECTRICAL CONNECTIONS WARNING: Always disconnect pump from electricity before performing any work on the. Under-sized wiring can cause failure and even fire. Use proper wire size specified in the Wire Size Chart. Replace damaged or worn wiring cord immediately. Do not kink power cable and never allow the cable to come in contact with oil, grease, hot surfaces, or chemicals. The pump must be properly grounded using the proper wire cable with ground. CAUTION: Protect the power cable from coming in contact with sharp objects. All wiring should be performed by a qualified electrician in accordance with the National Electric Code and local electric codes. Connect the pump to a separate electrical circuit with a dedicated circuit breaker. Refer to the Wire Size Chart for proper fuse size. Distance from Motor to Meter 0-0 Ft. 0-00 Ft. 00-0 Ft. 0-00 Ft. 00-00 Ft. WIRE SIZE CHART Recommended Copper Wire and Fuse Sizes Single Phase Motors / HP Volt 0 Volt 0 8 * Fuse Size (Amps) (*) Not economical to run in V, use 0 V 0

PUMP ELECTRICAL CONNECTIONS PUMP ELECTRICAL CONNECTIONS Wiring the pressure switch CAUTION: Make certain that the power source matches the pump requirements. This pump has a dual voltage and can run on either V or 0 V. Pump is pre-set at the factory to run on 0 V.. To change pump voltage, remove the square voltage switch cover at the top of pump and move the voltage switch as shown. V Setting 0 V Setting. Connect the green ground wire from the power supply to the remaining green ground screw in the pressure switch and re-attach the pressure switch cover. power supply Ground Screws Wire from. To connect the pressure switch, remove the switch cover and insert an electrical wire strain relief (not included) into the opening in the side of the pressure switch. Strain Relief Pressure Switch PUMP PRIMING AND STARTUP PRIMING CAUTION: All pumps must be primed (filling the cavity with water) before they are first operated. This may take several gallons of water, as the suction pipe will be filled in addition to the cavity of pump.. Remove pipe plug or pressure gauge (not included) at the top of the discharge tee and the vent plug in front of the discharge tee. Vent plug Priming plug or pressure gauge. Thread the electrical wire (not included) from the power supply through the strain relief and tighten both screws on the strain relief. Do not crush wire. power supply. Slowly fill the discharge tee with water until water overflows the vent plug opening. Replace the vent plug loosely. NOTE: It will take several minutes to fill pump and suction pipe completely. Vent plug opening Vent plug Priming plug opening Discharge Tee. Connect the two wires from the power supply to the two outside terminals on the pressure switch. power supply. Be sure entire suction pipe is filled when priming. Depending on the length of suction pipe, many gallons will be needed to fill the entire system. Outside terminal Outside terminal

PUMP PRIMING AND STARTUP CARE AND MAINTENANCE. Check to be sure water in the cavity of pump stays constant. If water level goes down, it could indicate a leak in the foot valve, check valve or suction pipe. pipe Water Level Winterizing CAUTION: Drain the entire system if there is danger of freezing.. To drain pump, remove the drain plug located on the front of pump and the vent plug located on the top of pump. Vent Plug Check for leaks Drain Plug. Once pump is filled, wrap the pressure gauge or discharge tee plug and vent plug threads with thread tape and thread into pump. Tighten with wrench. NOTE: Before turning on breaker, open several outlets or faucets to allow water flow during priming. 6. Turn on breaker to start pump. IMPORTANT: If the pump hums instead of pumping or turns off repeatedly, shut pump off immediately. Check voltage. Make sure your incoming voltage matches the pump wiring voltage. See PUMP ELECTRICAL CONNECTIONS. IMPORTANT: If pump fails to prime within five minutes: Turn power off at the breaker box and check all pipe connections for leaks. All connections must be water and air tight in order for pump to operate. 7. Check suction pipe for any sagging. Support suction pipe in a straight line to the pump. 6 7 Breaker Box To Pressure Tank Vent Plug in. Discharge Pressure Gauge or Discharge Tee Plug WARRANTY This product is warranted for one year from the date of purchase or two years from the date of manufacture, whichever occurs first. Subject to the conditions hereinafter set forth, the manufacturer will repair or replace to the original consumer, any portion of the product which proves defective due to defective materials or workmanship. To obtain warranty service, contact the dealer from whom the product was purchased. The manufacturer retains the sole right and option to determine whether to repair or replace defective equipment, parts or components. Damage due to conditions beyond the control of the manufacturer is not covered by this warranty. THIS WARRANTY WILL NOT APPLY: (a) To defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (b) to failures resulting from abuse, accident or negligence or use of inappropriate chemicals or additives in the water; (c) to normal maintenance services and the parts used in connection with such service; (d) to units which are not installed in accordance with normal applicable local codes, ordinances and good trade practices; and (e) the unit is used for purposes other than for what it was designed and manufactured. RETURN OF WARRANTED COMPONENTS: Any item to be repaired or replaced under this warranty must be returned to the manufacturer at Kendallville, Indiana or such other place as the manufacturer may designate, freight prepaid. THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND MAY NOT BE EXTENDED OR MODIFIED BY ANYONE. ANY IMPLIED WARRANTIES SHALL BE LIMITED TO THE PERIOD OF THE LIMITED WARRANTY AND THEREAFTER ALL SUCH IMPLIED WARRANTIES ARE DISCLAIMED AND EXCLUDED. THE MANUFACTURER SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, SUCH AS, BUT NOT LIMITED TO DAMAGE TO, OR LOSS OF, OTHER PROPERTY OR EQUIPMENT, LOSS OF PROFITS, INCONVENIENCE, OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY TYPE OR NATURE. THE LIABILITY OF THE MANUFACTURER SHALL NOT EXCEED THE PRICE OF THE PRODUCT UPON WHICH SUCH LIABILITY IS BASED. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow limitations on duration of implied warranties or exclusion of incidental or consequential damages, so the above limitations may not apply to you. NOTE: Look for leaks or a milky color in the discharged water, which indicates an air leak. Re-prime if necessary, following steps through 6 above. Reset breaker at the breaker box. All connections must be water and air tight in order for pump to operate. -/ in. Well Foot Valve FOR YOUR WARRANTY PROTECTION, THE WARRANTY REGISTRATION MUST BE COMPLETED AND RETURNED TO THE WARRANTY INFORMATION CENTER WITHIN TEN DAYS OF INSTALLATION. WARRANTY VALID IN CANADA AND MEXICO.

TROUBLESHOOTING REPLACEMENT PARTS LIST Problem Possible Cause Corrective Action Little or no. Pump is not primed. Follow priming instructions (page ) discharge. lift too high or too long. Move pump closer to water source. Lift should be less than ft.. Hole or air leak in suction line. Repair or replace. Use pipe tape and pipe sealing compound. Foot valve too small. Match foot valve to piping or install one size larger foot valve. Foot valve or suction line not. Submerge lower in water submerged deep enough in water 6. Voltage switch incorrect 6. Be sure V or 0 V power supply matches voltage switch setting on pump 7. Casing gasket leaking 7. Replace Pump will not deliver water or develop pressure Pump vibrates and/or makes excessive noise Pump will not start or run. Pump is not primed. Follow priming instructions (page ). Leak in suction line. Repair or replace. dope all threads. Discharge line is closed and priming air has nowhere to go. Open several outlets or faucets during priming procedure. Foot valve is leaking. Replace foot valve. Foot valve not submerged below. Lower foot valve and reprime water level. Mounting plate or foundation not rigid. Reinforce enough. Foreign material in pump. Disassemble pump and clean. Impeller damaged. Replace. Voltage switch incorrect. Be sure V or 0 V power supply matches voltage switch setting on. Blown fuse or open circuit breaker. Replace fuse or close circuit breaker. Loose or broken wiring. Tighten connections, replace broken wiring. Stone or foreign object lodged in. Disassemble pump and remove impeller foreign object. Thermal overload has opened circuit. Allow unit to cool, restart after reason for overload has been determined For replacement parts, call our customer service department at -800-7-0, 7:0 a.m. - p.m., EST, Monday - Friday. PART DESCRIPTION PART NO. B O-rings / Nozzle / Venturi Kit 07 C Diffuser 0707 D Impeller 0709 E Mechanical Seal 070 F O-Ring 07 G Pressure Switch 07 G B C D E F 6 7