SEE PAGE 4 FOR IMPORTANT INFORMATION CONCERNING LIMITED WARRANTY, AND LIMITATION OF LIABILITY. Operating Instructions. Please read before use

Similar documents
CORPORA 110N DATASHEET I SEE PAGE 4 FOR IMPORTANT INFORMATION CONCERNING LIMITED WARRANTY, AND LIMITATION OF LIABILITY. I

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

SEE PAGE 5 FOR IMPORTANT INFORMATION CONCERNING LIMITED WARRANTY, AND LIMITATION OF LIABILITY AIR SUPPLY FITTING (SS) QA SERIES

TBHD1 CRIMPING TOOL FOR THOMAS & BETTS TS DIES

SCT SERIES PRE-SET TENSION SAFE-T-CABLE APPLICATION TOOL

MPT-200A SPECIFICATIONS AND OPERATING INSTRUCTIONS

HXE4B BATTERY POWERED CRIMP TOOL

ABOT4001 REV1 BATTERY POWERED CRIMP TOOL

HDE36B BATTERY POWERED CRIMP TOOL

HDE36 BATTERY POWERED CRIMP TOOL

ME310B BATTERY POWERED CRIMP TOOL

AFE8B BATTERY POWERED CRIMP TOOL

failure, or a reduced service life of the wiring system.

Analog Durometer Model AD-100

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

Electric Actuator Installation, Operation & Maintenance Manual

Procedure to Install the New Autogap components in ER-1225 and ER825 Brake with inverted Armature Hub

Installation Instructions Receiver Rack (Part # 7700) Universal Application

AT Clutch Major Service Sizes 25, 55, 115

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

Force Test Stands Series TS MODELS TSA750, TSA750H, TSB100, TSC1000 & TSC1000H. User s Guide

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

INSTALLATION INSTRUCTIONS

Universal Tablet Mounting Kit with Built-In FM Transmitter 88.7 IPD-UNVBT OWNER S MANUAL IPD-UNVBT 3_14_14.indd 1 3/14/2014 5:28:50 PM

Force Test Stands Series TS MODELS TSA750, TSA750H, TSB100, TSC1000 & TSC1000H. User s Guide

ODY-17-1 DIGITAL COMPASS DISPLAY

INSTRUCTION MANUAL SURFACE RESISTIVITY METER SRM-110

Wrap Spring Clutches & Brakes CB & Super CB Series P-2026-WE SM592-gb-02/08

A5000GEC-24VDC ZERO SPEED SWITCH

ODY-01-1 or ODY-01-2 SPEEDOMETER

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

Compressor Clutch Replacement Procedure

P5510. Users Manual. Pneumatic Comparison Test Pump

FR1118- P10. User s Manual

EAGL 1-Touch Laser Level

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

C3000 SIGNAL TRANSMITTER. Introduction

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

A Member of the. Integrated Metering Technologies

Installation Instructions Soft Top Replacement Hardware, Wrangler

AXD 530 MicroManometer

A1100 GUARDIAN OVERFILL PREVENTION SYSTEM

SFP-250 and SFP-400. Installation Instructions. An Altra Industrial Motion Company P-231-WE

OPERATIONS MANUAL MODEL MT-500

Preassembled Clutch/Electrically Released Brake Module

series USER MANUAL

A Member of the. Integrated Metering Technologies

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Electromagnetic Particle Clutches and Brakes Models: POC, PHC-R, PMC-A3, POB, PRB and PTB-BL3 P Performance Manual

CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

& r"1aintef~ance. Your KENBAK-l computer is a quality instrument which is. should expect months or years of operation without significant

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

SIDE-WIND, A-FRAME TRAILER JACK. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

ODY-10-1 rev. B FUEL PRESSURE GAUGE

Force Test Stands Series ES MODELS ES10 & ES20. User s Guide

Preassembled Clutch/Brake Module

Warner Electric UNIBRAKE Motor Brakes

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

idrive Power Cord Extender Installation Instructions MODELS: 3960M/3961S (1) 25 POWER CORD DRILL WITH 3/32 DRILL BIT

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

Torque Wrenches

OWNERS MANUAL HF4263

ERD Electrically Released Brakes

OWNERS MANUAL HF PAIR VERTICAL DUMBBELL RACK. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

ODY-04-1 or ODY-04-2 rev. B WATER TEMPERATURE GAUGE

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Force Test Stands Series ES MODEL ES05

P5514, P5514-V & P5514-EP Hydraulic Comparison Test Pump

3.5mm Coaxial Calibration Kit

INTRODUCTION INSTALLATION

ODY-19-1 AIR PRESSURE GAUGE

TABLE OF CONTENTS. Important Safety Information 3. Parts List 4

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Preassembled Clutch/Electrically Released Brake Module

flexible infrared thermometer

ROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008

Safety Sentry Electronic Breakaway Switch

HLY-1111 HEAD TEMPERATURE GAUGE

INSTALLATION INSTRUCTION & OWNER S MANUAL

Power Float Manifold. Installation and Operations Manual Module 11A

MARCY Recumbent Bike PL-960

Adapter. Owner's Manual & Warranty. Item# JSFSA. Compatible with Weego Jump Starter Battery+ Models JS 12 & JS 18

Installation Instructions. Application List Dodge 24V PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION

INSTRUCTIONS Refillable, reusable. Extra versatile. Pressurized by free air

Hollywood Racks Sport Rider Hitch Rack Instruction Manual

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

HLY-1013 or HLY-1014 MINI SPEEDOMETER

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

2.4mm Coaxial Calibration Kit

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

Electro-Brake 375, 475, 650, 825, 1000, 1225

LAYCOCK SYSTEMS, INC N. 43 rd Street Tampa, FL

Potentiometer Thrust Plate Kit (50421) Installation & Operator s Instruction Manual

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

Model FM2642 Wall Mount. Full Motion Television Wall Mount

Transcription:

STATIC TORQUE METER SEE PAGE 4 FOR IMPORTANT INFORMATION CONCERNING LIMITED WARRANTY, AND LIMITATION OF LIABILITY. Operating Instructions Please read before use 0-200 in. lbs. torque range Increment markings of 5 in. lbs. 1 / 4" drive BT-ST-701 Unequalled Accuracy Specified Torque Values Improve Assembly Procedures A special repeated, assembly and their torque meter for the controlled, accurate of circular connectors. accessories. The Static Torque Meter works on the proven accurate principle of applied force down the center line of the work. The Torque Meter, utilizing the Daniels Adaptor Tool, applies this principle to the assembly of circular connectors and their rear accessories. It hos o balanced pointer and o calibrated alloy steel torque beam, for added accuracy ond long life. The Torque Meter is certified to meet the accuracy in Federal Specification GGG-W-00686D, os calibrated at the factory. The accuracy of this wrench is ±4% between 40in-lb and 200in-lb. Accuracy is not controlled below 40in-lb. In the assembly of circular connectors and their rear accessories, the use of a specified torque value improves the consistency of the assembly process by answering the question, How tight is tight?". The unique Torque Meter works in a static (stationary) mounting position enabling the operator increased use of his/her hands. The meter head con be locked anywhere to o full 90" tilt range to facilitate various access requirements. The exclusive electric signal light eliminates the need to watch intricate dial markings in the torque operation. The Torque Meter should be dedicated for either left or right direction and can be mounted to a bench top, or for mobility, to its clamp base mount accessory. 8 U ilt to La st The Torque Meter hos a precision geared meter movement for increased durability. All parts are mode from alloy and tool steels, specially heat treated; external ports are nickel and chrome plated. DANIELS MANUFACTURING CORP., 526 THORPE ROAD, ORLANDO, FLORIDA 32824 USA PHONE (407) 855-6161, FAX (407) 855-6884. COPYRIGHT 2001 DANIELS MANUFACTURING CORP. WWW.DMCTOOLS.COM E-MAIL: DMCOOMCTOOLS.COM ALL RIGHTS RESERVED 8/16 REV. C PAGE 1 BT-ST-701-DS

,,,. DANIELS MANUFACTURING -.., 1 CORPORATION Operation Method 1. and Setting of Setting Electric torque va I ue. Electric Arm at Signal Dial desired Certification Bezel This Torque Tool, as calibrated at the factory, is certified to meet or exeed accuracy specified in the Federal Specification GGG-W-00686C and was calibrated on o torque standard that is traceable to the Notional Bureau of Standards. --- Electric Arm 1 / 4" Drive 0 0 Pointer Light Bulb Battery Cover Note: For consistency and accuracy it is suggested that this torque tool be dedicated for use in one direction only. Should this not be practical for your application the following procedure should be followed for initial setting or when changing direction. It is recommended that the tool be operated 3 or 4 times at half load in the torque direction that will be used. Full load may now be applied for your application. Right-Hand Torque (force in clockwise direction) 1. Turn the bezel clockwise (CW) until light goes on. 2. Continue to turn clockwise (CW) and set pointer onto desired torque value. 3. Now, turn bezel counter-clockwise (CCW) until pointer is aligned with zero (0). 4. When preset as stated above, the signal light goes on when the applied torque equals the wrench setting. 5. When pressure on the wrench is released, the pointer will return to zero (0). 6. The wrench can be used for repetitive operations without resetting provided the torque on the wrench is released as soon as the signal light goes on. If torque is continued ofter the light goes on, the wrong torque (over torque) will be applied and the wrench will hove to be reset. If in doubt, always reset. Left-Hand Torque (force in counter-clockwise direction) Proceed as explained for right hand torque execpt turn bezel counter-clockwise (CCW) until light goes on and pointer is aligned with zero (0). Then, turn clockwise (CW) to desired torque value. PAGE 2

,,,. fl,. DANIELS MANUFACTURING,,.,, W'j CORPORATION Method 2. Setting Electric Arm at zero. Right-Hand Torque (force in clockwise direction) 1. Turn bezel clockwise (CW) until light goes on. 2. Continue to turn bezel clockwise (CW) until zero (0) of scale is lined up with pointer. 3. Now, turn bezel counter-clockwise (CCW) until light goes off and pointer is aligned with the desired torque value. Pointer is now preset to a desired torque. 4. Apply force in clockwise (CW) direction. The preset torque is reached when the light goes on. When the force is released the pointer will return to the torque value. 5. To change the preset torque to another value, return to Step 1. 6. Important - always make sure the electric contact arm is zeroed. Left-Hand Torque (force in counter-clockwise direction) Proceed as explained for right hand torque except turn bezel counter-clockwise (CCW) until light goes on and pointer is aligned with inner zero. Then turn clockwise (cw) to set pointer to desire torque value. Instructions for Static Torque Meter with the Beta Adaptor Tool on Circular Connectors, and their Accessories. After the backshell has been hand tightened using the Daniels Adaptor Tool (see Adaptor Tool Information), the Adaptor Tool and the connector assembly is inserted into the drive of the preset Static Torque Meter. The backshell is then tightened using the Daniels Strap Wrench, or other means of turning the backshell safely. Once the proper torque value has been reached, the signal light comes on and pressure is stopped. The Torque Meter measures force from the center line of the work, which is the most accurate method for tightening accessories to a specified torque value. PAGE 3

Battery and Bulb 1. Bulb, G.E. No. 112, 1.2 V,.22 A, or equivalent 2. Battery: AA, 1. 5 V or equivalent 3. Replace bulb without opening the lid. Check for light by turning the bezel until contact is mode. 4. To replace battery, open the lid and loosen the bulb. Place the new battery into the housing and tighten the bulb. Check the light by turning the bezel until contact is mode. LIMITATION OF LIABILITY DANIELS MANUFACTURING CORPORATION IS NOT LIABLE FOR CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY NATURE OR KIND RESULTING FROM THE USE, OR MISUSE, OF ANY OF ITS PRODUCTS. OWNERS AND USERS OF DMC PRODUCTS ASSUME FULL RESPONSIBILITY FOR INSTRUCTING THEIR EMPLOYEES IN THE PROPER AND SAFE USE OF SUCH PRODUCTS. LIMITED WARRANTY DMC (Daniels Manufacturing Corporation) warrants each new product sold by it to be free from defects in material and workmanship under normal use and service. DMC's obligation under this warranty is limited to the free correction or, at DMC's option, the refund of the purchase price of any such product which proves defective in normal service within ninety (90) days ofter delivery to the first user, provided that the product is returned to DMC with all transportation charges prepaid and which shall appear to DMC's satisfaction, ofter DMC's inspection, to hove been defective in material or workmanship, it being understood that DMC products ore not consumer products. This warranty shall not cover any damage to any product which, in the opinion of DMC, was caused by normal wear, misuse, improper operation, tampering, neglect or occident. This warranty is in lieu of oil other warranties expres or implied. No warranty, express or implied, is mode or authorized to be mode or assumed with respect to products of Daniels Manufacturing Corporation other than those herein set forth. PAGE 4

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Daniels Manufacturing: BT-ST-701