SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

Similar documents
Example. U side. Stations SY5000

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

Series SY3000/5000 How to Order Manifold

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

VQ1000. How to Order Manifold. Kit type

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

Series SY3000/5000/7000

4/5 Port Solenoid Valve

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

Series SY3000/5000/7000

3 Port Solenoid Valve

4/5 Port Solenoid Valve

Plug Lead Unit: Flip Type

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

5 Port Solenoid Valve

5 Port Solenoid Valve

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VQZ1000/2000/3000 Single Unit

5 Port Solenoid Valve

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

5 Port Solenoid Valve

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

5 Port Solenoid Valve

Base Mounted Plug-in/Plug Lead: Single Unit

5 Port Solenoid Valve

5 Port Solenoid Valve

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

Series VQ Port Solenoid Valve

5 Port Solenoid Valve

3 Port Solenoid Valve

Pilot Operated 2 Port Solenoid Valve for Dry Air

Series SYJ300/500/700

Fieldbus System (Output device for driving 5 port solenoid valves)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

Series SYJ3000/5000/7000

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

How to Order Manifold. Kit type L8 B4 B6 B8 LM

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

Specifications. Fluid Ambient and fluid temperature ( C)

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

5 Port Solenoid Valve

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Series VP3145/3165/3185

Series SYJ Way 4 and 5 Port. Rubber Seal Solenoid Pilot Valve

How to Order Manifold. Option Symbol

3 Port Solenoid Valve

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Gateway System Serial Transmission System

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

Vacuum Release Valve with Restrictor

3 Port Solenoid Valve

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Manifold Specifications Stacking Type

3 Port 3 Position Valve

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

Fieldbus System (Gateway Decentralized Type)

Manifold Specifications

5 Port Solenoid Valve Plug Lead Type

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Series PCW. PC Wiring System

Vacuum System Peripherals

Pilot Operated 2 Port Solenoid Valve for Dry Air

4/5 Port Air Operated Valve. SYJA3000 Series. How to Order. (Manifold use only) Type of actuation. 2 position single. 3 position closed center

New Concept Connector Type Manifold

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

Manifold Specifications

Space Saving Vacuum Ejector/Vacuum Pump System

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Manifold Specifications

3 Port Solenoid Valve Direct Operated Poppet Type

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500

2.26 S OLENOID VALVES S ERIES VQ1000

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Series SV1000/2000/3000/4000

Transcription:

Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Individual Wiring How to Order Manifold SSY 4 0 U C6 How to Order Valve Manifold ssembly Ordering example SY000 SY000 Valve stations 02 2 stations 20 20 stations SU/EXH block assembly mounting position Symbol Mounting position pplicable no. of stations U 2 to 10 stations D (oth sides) 2 to 20 stations M Special specifications For special specifications, indicate separately on the manifold specification sheet. Stations + + + + Double solenoid (24 VDC) SY240-G (2 sets) Single solenoid (24 VDC) SY140-G (2 sets) lanking plate assembly 000-7-1 Cylinder port size C6: With for ø6 Manifold base ( stations) SSY-4-0D-C6, port size (Metric size) (Inch size) Symbol ort size pplicable series Symbol ort size pplicable series C4 for ø4 N for ø 2 " C6 for ø6 SY000 N7 for ø 1 4 " SY000 M Mixed M Mixed C4 for ø4 N for ø 2 " C6 for ø6 N7 for ø 1 4 " SY000 SY000 C for ø N9 for ø 16 " M Mixed M Mixed In the case of mixed specifications (M), indicate separately on the manifold specification sheet. Option When a longer is desired than the specified stations, specify the station number to be required. (20 stations at maximum) For external pilot specifications and built-in silencer, refer to catalog on page 1-4-194. SSY-4-0D-C6 000-7-1 SY140-G SY240-G 2 1 1 set (Type 4, stations manifold base part no.) 1 set (lanking plate assembly part no.) 2 sets (Single solenoid part no.) 2 sets (Double solenoid part no.) The asterisk denotes the symbol for assembly. refix. it to the part nos. of the solenoid valve, etc The valve arrangement is numbered as the 1st. station from regardless of the mounting position of SU/EXH block assembly. In ordering, specify the part nos. in the order from the 1st. station on. esides, when the arrangement will be complicated, fill out the manifold specification sheet to instruct us. 1-4-0

ase Mounted SY000/000 How to Order Valves SY 2 40 L SY000 SY000 Type of actuation 1 2 position single 2 2 position double position closed center 4 position exhaust center position pressure center Nil T DC Coil specifications Standard With power saving circuit (24, VDC only) ower saving circuit is not available in the case of D, DO or W type. ated 24 VDC 6 VDC V 6 VDC S VDC VDC C ( Hz) 0 60 1 100 VC 2 200 VC 110 VC [11 VC] 4 220 VC [20 VC] DC specifications of type D and DO is only available with and 24 VDC. For type W, DC is only available. D and DO only available for SY000. Electrical entry Grommet G: Lead wire length 00 mm H: Lead wire length 600 mm Electrical entry for G, H, L, M, W Nil S Z U Nil Non-locking push type D ush-turn locking slotted type E ush-turn locking lever type Light/Surge Without light/surge With surge With light/surge With surge (Non-polar type) With light/surge (Non-polar type) For C valves there is no S option. It is already built-in to the rectifier circuit. For and U, DC is only available. ower saving circuit is only available in the "Z" type. Electrical entry for D Nil Without light/surge S With surge (Non-polar type) Z With light/surge (Non-polar type) 24,, 6,, VDC/100, 110, 200, 220 VC L plug connector L: With lead wire (Length 00 mm) LN: Without lead wire LO: Without connector DOZ is not available. For C valves there is no S option. It is already built-in to the rectifier circuit. M plug connector M: With lead wire (Length 00 mm) MN: Without lead wire MO: Without connector 24, VDC/ 100, 110, 200, 220 VC DIN terminal (SY000) D: With connector DO: Without connector 24,, 6,, VDC M connector WO: Without connector cable LN, MN type: with 2 sockets. D and DO only available for SY000. DIN terminal type Y conforming to DIN460C standard is also available. For details, refer to page 1-4-201. For connector cable of M connector, refer to page 1-4-209. SV SZ SY SYJ 1-4-1

ase Mounted SY000/000 Manifold Specifications Model pplicable valve Manifold type (SU)/ (EXH) Valve stations, port orting specifications ort size Manifold base weight W (g), n: Stations Location Direction, port, port SSY-4 SSY-4 SY 40 SY 40 Stacking type/ mounted Common SU, Common EXH Note 1) 2 to 20 stations ase Side C ( for ø) C10 ( for ø10) C4 ( for ø4) C4 ( for ø4) C6 ( for ø6) C6 ( for ø6) C ( for ø) 2 to 10 stations: W = 22n + 11 11 to 20 stations: W = 22n + 140 2 to 10 stations: W = 47n + 16 11 to 20 stations: W = 47n + 190 Note 1) For more than 11 stations, supply pressure to port on both sides and exhaust from port on both sides. Flow Characteristics Model 1,, (, E, E) SSY-4 SSY-4 C C10 ort size 4, 2 (, ) C6 C Flow characteristics 1 4/2 ( /) 4/2 / (/ E/E) C (dm / (s bar) ) b Cv C (dm / (s bar) ) b Cv 0. 2.2 0.21 0.24 0.22 0. 0.9 2. 0.1 0.1 0.22 0. Note) The value is for manifold base with stations and individually operated 2 position type. 1-4-2

ase Mounted SY000/000 Manifold Option Individual SU spacer assembly End plate SU port ssembly part no. ort size t SY000 SY000--2 M x 0. 11 SY000 SY000--16 1 1 Note) The SU port may be either on the lead wire side or on the end plate side. lanking plate assembly SY000 SY000 Dimensions/ VZ1000 11 1 efer to L dimensions No. L Dimension No. L Dimension 0 9 11 2. No. 22 L Dimension 7 No. L Dimension 10. No. 44 L Dimension 64 No. L Dimension 7. No. 66 L Dimension 92 ssembly part no. 000-7-1 000-76- 1 2 110. 24 2. 4 2 4 660. 6 79 67 9. 1 14 260. 27 24 9 6. 4 46 67 t 4 1. 14 1 2. 2 26 410. 42 7 60. 47 4 6. 69 7 10. 2 6 69 94 960. 9. 70 97 Individual EXH spacer assembly SU block disk SU block disk ssembly part no. ort size t SY000 SY000-9-2 M x 0. 11 SY000 SY000-9-16 1 1 Note) The EXH port may be either on the lead wire side or on the end plate side. Thread type Nil c F G N NT T NTF 6 160. 16 29 27 2 4. 44 7 49 0 710. 72 60 4 71 9. EXH port 1 10. 2 9 40. 9 61 62 60. 7 7 1. 19 29 0 460. 47 1 2 7. 74 Caution Mounting screw tightening torques M2: 0.16 N m M: 0. N m M4: 1.4 N m Fill in with an appropriate no. listed on the table of DIN rail dimensions shown below. L 19 20. 4 41 42 610. 62 6 64. 9 9 10 210. 22 21 60. 1 2 4. 49 4 6. 4 760. 77 6 910. efer to dimension on pages starting with page 1-4-6 for lengths that correspond to the number of manifold stations. t y installing a SU block disk in the pressure supply passage of a manifold valve, it is possible to supply two or more different high and low pressures to one manifold. SY000 SY000 L Label for block disk VZ000--1 Label for SU block disk Label for EXH block disk Silencer with For SY000 (ø) For SY000 (ø10) Label for SU/EXH block disk L lug (white) These are inserted in unused cylinder ports and SU, EXH ports. urchasing order is available in units of 10 pieces. Dimensions pplicable fittings size ød 4 art no. 000-77-1 000-77-1 Model N20-KM N200-KM10 N00-KM10 SY000 SY000 Effective area 14 mm 2 26 mm 2 0 mm 2 ø16 ø22 ø2 art no. 000-77-1 000-77-1 26. 70 C 1 0. 97 Model L D KQ2-04 16 2 6 6 KQ2-06 1 KQ2-0 20. 9 10 10 KQ2-10 22 4 1 " 2 " 1 4 " 16 " ød y installing an EXH block disk in the exhaust passage of a manifold valve, it is possible to divide the valve s exhaust so that it does not affect another valve. (Two block disks are needed to divide both exhausts.) The labels shown below are used on manifold stations containing SU/EXH block disk(s) to show their location. ( pcs. each) Note) When a block disk is concurrently ordered by specifying on the manifold specification sheet, etc., a label will be stuck on the position where block disk is mounted. The silencer plugs directly into the s of the manifold. L C ød KQ2-01 16 1. KQ2-0 16 2 6 KQ2-07 1. KQ2-09 20. 9 10 SV SZ SY SYJ 1-4-

ase Mounted SY000/000 Manifold Option How to Order Interface egulator (SY000/000 only) SY000 Y000 0 SY000 2 Y000 00 2 ressure gauge connection port 0 06 M1 egulating port 1 1 port port ( controlled type, port regulation) port ( controlled type, port regulation) ressure gauge (G1-10-01) [for odd number station] ressure gauge (G1-10-01) [for even number station] lug (M-) In the case of Y000 with a pressure gauge when mounting on the manifold, use caution that the part numbers are different between the odd no. stations and the even no. ressure gauge connection port 00 M1 egulating port 1 1 port port ( controlled type, port regulation) port ( controlled type, port regulation) ressure gauge (G1-10-01) lug (M-) Y000-0- -2 Y000-06- -2 Y000-M1- -2 Y000-00- -2 Y000-M1- -2 (For mounting odd (For mounting even number stations) number stations) + + + + + ccessory ound head combination screw Y000 SY000-2-10 (M26) Y000 M x 4., Matt nickel plated Gasket 000-7-4 000-7-6 Caution Mounting screw tightening torques M2: 0. N m M: 0. N m 1-4-4

ase Mounted SY000/000 Dimensions: SY000 [ ]: C SSY-4- Stations D- utton for release (itch) =16 26 SSY-4- Stations U- utton for release (itch) 26 =16 2 + + Stations n 2 stations 110. 100 4 1 4 6 7 9 10 stations 14 160. 19 210. 22 2. 17. 10 162.. 200 2. 22 116 16 12 14 14. 164 10 1 196 1. 2 11. 1. 100. With interface regulator (with gauge) (itch) =16 26 4. 4. 41.2 69. (7.2) 1. 2 (Lead wire length) pprox. 00 2 1. (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 119. [4.2] 44.2 (For DIN: 4.) 1.6 (For DIN: 2.9) 1.2 (For DIN: 2.). + + (ail mounting hole pitch:.) (.) (, port) pplicable tubing O.D.: ø10, ø/" holding screw 4..4 [.6] 41.2 107.2 [111.6] (), port pplicable tubing O.D.: ø10, ø/" (Lead wire length) pprox. 00 (Light/Surge ) 119. [4.2] 44.2 (For DIN : 4.) 1.2 1.6 (For DIN : 2.9) (For DIN : 2.). holding screw (.), port pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 4..4 [.6] 41.2 107.2 [111.6] () (ail mounting hole pitch:.) 71.1 [7.1].7 (Station n) (Station 1) (Light/Surge ) + + + + + 42.7 lock separation button (ush type) 7. ø1 42.7 94.1 [101.1] 1-4-

ase Mounted SY000/000 DIN ail Manifold Exploded View Type 4 c r release button w t + y q + + w a olts e b lock separation button c release button SMC eplacement arts No. Description art no. SY000 SY000 Note : SY000 (Metric size) C4: With for ø4 (Inch size) N: With for ø 2" C6: With for ø6 N7: With for ø 1 4" Manifold block SY000 (Metric size) C4: With for ø4 (Inch size) N: With for ø q assembly 000-0-1-000-0-1- 2" C6: With for ø6 N7: With for ø 1 4" C: With for ø N9: With for ø 16" (Gasket 6 is supplied as an accessory.) w (Metric size) (Metric size), port SY000 (Metric size) With for ø SU/EXH block 000-1-1 000-1-1 (Inch size) With for ø 16" assembly (Inch size) (Inch size), port SY000 (Metric size) With for ø10 000-1-1 000-1-1 (Inch size) With for ø " e End block assembly 000-2-1 000-2-1 For r End block assembly 000--1 000--1 For t ound head SY000-2-4 M x 26 combination screw (Matt nickel plated) y Gasket 000-7-4 000-7-6 u VZ1000-11-1- efer to page 1-4-. u 1-4-10

ase Mounted SY000/000 DIN ail Manifold Exploded View How to Increase Manifold ase Station expansion is possible at any position. 1 2 4 Loosen bolt a fixing the manifold base until it begins to turn idly. (While pressing releasing buttons c, at two locations, separate the manifold base from the.) ress manifold block assembly dividing button b, that are at the location where manifold bases are to be added, until button b locks, and then separate the block assemblies. Mount additional manifold block assembly on the as shown in the Fig. (1). ress the block assemblies until a click sound is produced, and tighten the bolts a to fix them to the. Caution (Tightening torque: 1.4 N m) (While lightly holding the blocks after fixing an end block on one side, tighten the other end block for for better sealing.) Caution Note 1) When there are 10 or fewer manifold block assemblies, and more are added to make a total of 11 or more, a supply/exhaust block assembly must also be added. Note 2) When disassembly and assembly are performed, air leakage may result if connections between blocks and tightening of the end block s holding screw, is inadequate. efore supplying air, confirm that there are no gaps, etc. between blocks, and that manifold blocks are securely fastened to the. Then supply air and confirm that there is no air leakage before operating. Fig. (1) lock mounting procedure How to Change Fitting ssembly. O-ring Clip Fitting assembly Fitting ssembly art No. Metric size for ø4 SY000 for ø6 for ø4 SY000 for ø6 for ø Inch size for ø 2 " SY000 for ø 1 4 " for ø 2 " SY000 for ø 1 4 " for ø 16 " Type 4 manifold permits change in the and port sizes by changing the manifold block fitting assembly. fter removing the valve, remove the clip with a screwdriver, etc. For mounting a new fitting assembly, insert it and then insert a clip until it will not come out of the manifold block. VVQ1000-0-C4 VVQ1000-0-C6 VVQ1000-1-C4 VVQ1000-1-C6 VVQ1000-1-C VVQ1000-0-N VVQ1000-0-N7 VVQ1000-1-N VVQ1000-1-N7 VVQ1000-1-N9 Note 1) and ports cannot be changed. Note 2) Use caution that O-rings must be free from scratches and dust. Otherwise, air leakage may result. SV SZ SY SYJ Hook the here and press down in the direction of the arrow until a click sound is heard. 1-4-11

- - - - - Type4- N SY000/000 ase Mounted Manifold Stacking Type/DIN ail Mounted Connector ox How to Order Manifold SSY SY000 SY000 4 Specifications Symbol Specifications With connector box (+COM spec.) N With connector box ( COM spec.) The style of attached lead wire assembly is different. U 0 D C6 How to Order Valve Manifold ssembly Ordering example (SY000, +COM, ) DC 24V SMC CONNECTO OX + - 1 14 7 6 + + + + + Double solenoid (24 VDC) SY240-LOU (2 sets) Single solenoid (24 VDC) SY140-LOU (2 sets) Cylinder port size C6: With for ø6 Manifold base SSY-4-U-0D-C6 Connector box mounting position Symbol Mounting position U D Valve stations Symbol Stations Note 02 2 stations pplicable up to 16 solenoid 16 16 stations valves. SU/EXH block assembly mounting position Symbol Mounting position pplicable stations U 2 to 10 stations D oth sides 2 to 16 stations M Special specifications For special specifications, indicate separately on the manifold specification sheet. (Metric size) Symbol ort size.pplicable series for ø4 for ø6 SY000 Mixed C4 C6 M C4 C6 C M for ø4 for ø6 SY000 for ø Mixed / port size (Inch size) Symbol ort size pplicable series for ø /2" for ø 1 /4" Mixed SY000 N N7 M N N7 N9 M for ø /2" for ø 1 /4" for ø /2" Mixed In the case of mixed specifications, indicate separately on the manifold specification sheet. SY000 Option When a longer is desired than the specified stations, specify the station number to be required. (Max. 20 stations) For external pilot specifications and built-in silencer, refer to page 1-4-194. lanking plate assembly 000-7-1 SSY-4-U-0D-C6 1 set (Type 4, stations manifold base part no.) 000-7-1 1 set (lanking plate assembly part no) SY140-LOU 2 sets (Single solenoid part no.) SY240-LOU 2 sets (Double solenoid part no.) The asterisk denotes the symbol for assembly. refix it to the part nos. of the solenoid valve, etc. The valve arrangement is numbered as the 1st. station from regardless of the mounting position of connector box. In ordering, specify the part nos. in the order from the 1st. station on. esides, when the arrangement will be complicated, fill out the manifold specification sheet to instruct us. U SSY -4- D- -C is assembled with solenoid valve and lead wire assembly when shipping. When ordering manifold only (without valves/wires/options), refer to how to order on page 1-4-0 and list the connector box (VZ000-106-1) and the rail stopper (TXE1-SMC) below the manifold to allow for the connector box mounting at. (e sure to order station longer than number of the manifold stations.) In this case, please note that dimensions, and on pages 1-4-16 and 1-4-17 may vary slightly.) For other components, refer to page 1-4-1. SY000 SY000 Stations. 2 1 How to Order Valves SY 2 40 LOU Type of actuation 1 2 position single 2 2 position double position closed center 4 position exhaust center position pressure center D Nil Non-locking push type D ush-turn locking slotted type E ush-turn locking lever type ated 24 VDC 1-4-12

- + - + ase Mounted SY000/000 Manifold Specifications Model pplicable valve Manifold type (SU)/ (EXH) Valve stations, port orting specifications ort size Location Direction, port, port Manifold base weight W (g) n: Stations pplicable flat ribbon cable connector Wiring specifications Flow Characteristics SSY-4- N SSY-4- N SY 40 SY 40 Stacking type/ mounted Common SU, Common EXH 2 to 16 stations Note 1, 2) ase Side C ( for ø) C10 ( for ø10) C4 ( for ø4) C4 ( for ø4) C6 ( for ø6) C6 ( for ø6) C ( for ø) 2 to 10 stations: W = 26n + 207 11 to 20 stations: W = 26n + 229 2 to 10 stations: W = 2n + 24 11 to 16 stations: W = 2n + 279 Flat ribbon cable connector Socket: 20 pins MIL type with strain relief conforming to MIL-C-0 +COM specifications (Type 4-), COM specifications (Type 4-N) Note 1) For more than 11 stations, supply pressure to port on both sides and exhaust from port on both sides. Note 2) There is a limit depending on the number of solenoids. efer to How to Order. SV SZ SY SYJ Model 1,, (, E, E) SSY-4- SSY-4- C C10 ort size 4, 2 (, ) C6 C Flow characteristics 1 4/2 ( /) 4/2 / (/ E/E) C (dm /(s bar)) b Cv C (dm /(s bar)) b Cv 0. 2.2 0.21 0.24 0.22 0. 0.9 2. 0.1 0.1 0.22 0. Note) The value is for manifold base with stations and individually operated 2 position type. Manifold Wiring Diagram (Circuit diagram for the reference layout) +COM electric circuit diagram Connector box (Wiring example) Station 1 Station 2 Station COM electric circuit diagram Connector box (Wiring example) Station 1 Station 2 Station Triangle mark Station 4 Triangle mark Station 4 Station Station 24 VDC ower supply terminal 24 VDC ower supply terminal SoL. eference layout Connector box for +COM allows transmission until G71-OD16, manufactured by OMON Corp., to be connected directly for serial transmission. dditionally, it can also be used for the C wiring system. When an external power source must be supplied to the manifold, correct polarity must be observed, otherwise damage to LC is possible. The wiring of solenoid valves, corresponds with the labeled connector box 0 to 1 from. If valves other than non-polar type are used, this may cause malfunction. CONNECTO OX VZ000-106-1 SoL. 0 1 2 4 6 7 9 10 11 1 14 1 - + (Station n) - + - + - + - + (Station 2) (Station 1) SoL. 1-4-1

ase Mounted SY000/000 Manifold Option Individual SU spacer assembly Individual EXH spacer assembly SU block disk EXH block disk End plate End plate y installing a SU block disk in the pressure supply passage of a manifold valve, it is possible to supply two or more different high and low pressures to one manifold. y installing an EXH block disk in the exhaust passage of a manifold valve, it is possible to divide the valve s exhaust so that it does not affect another valve. (Two block disks are needed to divide both exhausts.) SU port ssembly part no. ort size t SY000 SY000--2 M x 0. 11 SY000 SY000--16 1 1 Note) The SU port may be either on the lead wire side or on the end plate side. (n assembly is shipped under the condition shown in the figure.) lanking plate assembly t EXH port t ssembly part no. ort size t SY000 SY000-9-2 M x 0. 11 SY000 SY000-9-16 1 1 Note) The EXH port may be either on the lead wire side or on the end plate side. (n assembly is shipped under the condition shown in the figure.) Thread type Nil c F G N NT T NTF SY000 SY000 Label for block disk VZ000--1 Label for SU block disk art no. 000-77-1 000-77-1 Label for EXH block disk SY000 SY000 art no. 000-77-1 000-77-1 The labels shown below are used on manifold stations containing SU/EXH block disk(s) to show their location. ( pcs. each) Label for SU/EXH block disk Note) When a block disk is concurrently ordered by specifying on the manifold specification sheet, etc., a label will be stuck on the position where block disk is mounted. Silencer with The silencer plugs directly into the s of the manifold. SY000 SY000 ssembly part no. 000-7-1 000-76- Cable assembly XT100-FC20-1 Caution Mounting screw tightening torques M2: 0.16 N m M: 0. N m M4: 1.4 N m ed For SY000 (ø) For SY000 (ø10) lug (white) Model N20-KM N200-KM10 N00-KM10 Effective area 14 mm 2 26 mm 2 0 mm 2 ø16 ø22 ø2 26. 70 C 1 0. 97 These are inserted in unused cylinder ports and SU, EXH ports. urchasing order is available in units of 10 pieces. Terminal number Connector ssembly for Flat ibbon Cable Cable length (L) 1. m m m ssembly part no. XT100-FC20-1 XT100-FC20-2 XT100-FC20- Connector manufacturers example Sumitomo M Limited Fujitsu Limited Japan viation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Note Cable 20 core x 22 WG For other commercial connectors, use a 20 pins with strain relief conforming to MIL-C-0. Warning Dimensions pplicable fittings size ød 4 Model L D KQ2-04 16 2 6 6 KQ2-06 1 KQ2-0 20. 9 10 10 KQ2-10 22 4 1 " 2 " 1 4 " 16 " KQ2-01 16 1. KQ2-0 16 2 6 KQ2-07 1. KQ2-09 20. 9 10 When mounting a valve or spacer on the manifold base or sub-plate, etc., those mounting directions are determined. If mounted in the wrong direction, the equipment to be connected may cause malfunction. efer to external dimensions, and then mount it. 1-4-14

- - - - - ase Mounted SY000/000 Manifold Option How to Order Interface regulator (SY000, 000 only) SY000 Y000 0 SY000 2 Y000 00 2 0 06 M1 egulating port 1 1 port port ( controlled type, port regulation) port ( controlled type, port regulation) ressure gauge connection port ressure gauge (G1-10-01) [for odd number station] ressure gauge (G1-10-01) [for even number station] lug (M-) In the case of Y000 with a pressure gauge when mounting on the manifold, use caution that the part numbers are different between the odd no. stations and the even no. stations to avoid gauges from interfering from each others. 00 M1 egulating port 1 1 port port ( controlled type, port regulation) port ( controlled type, port regulation) ressure gauge connection port ressure gauge (G1-10-01) lug (M-) SV SZ SY SYJ Y000-0- -2 (For odd number stations) Y000-06- -2 (For even number stations) Y000-M1- -2 Y000-00- -2 Y000-M1- -2 + + + + + ccessory ound head combination screw Y000 SY000-2-10 (M2 x 6) Y000 M x 4., Matt nickel plated Gasket 000-7-4 000-7-6 Caution Mounting screw tightening torques M2: 0.16 N m M: 0. N m 1-4-1

1 -+ -+ 2 0 4 6 -+ -+ Dimensions: SY000 SSY-4-U- Stations D- (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 1. (itch) =16 26 utton for release 2 pplicable connector: 20 pins MIL type With strain releaf (Conforming to MIL-C-0) 19.6 7 44.2 42. 1.6 6. 42.. CONNECTO OX VZ000-106-1 0 1 2 4 6 7 9 10 11 1 14 1 41 () (.), port pplicable tubing O.D.: ø10, ø/" 1.2 4. 41.2 With interface regulator (with gauge) (itch) =16 26 4. 44.2 69. (7.2) 4. LED for power supply ower supply terminal - + - + - + - + - + (ail mounting hole pitch:.) holding screw - + - + - + ø1 94.1 42.7 (Light/Surge ).1 42.6 6 71.1.7 42.7 SSY-4-D- Stations U- 26 (itch) =16 7 utton for release 2 7. 1. 1 - + 2 0 4 6 - + 0 ase Mounted SY000/000 SV SZ SY SYJ (Station n) (Station 1) lock separation button (ush type), port pplicable tubing O.D.: ø10, ø/" () 41 19.6 7 6. 44.2 4. 41.2 1.2 1.6 (.) 1 14 1 11 10 9 7 6 4 2 1 0 CONNECTO OX VZ000-106-1 (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" ower supply terminal LED for power supply. 42. 42. holding screw (ail mounting hole pitch:.) (Station n) (Station 1) (Light/Surge ) 71.1.7 42.7 - + - + lock separation button (ush type) - + - + - + 7. 42.6.1 pplicable connector: 20 pins MIL type With strain releaf (Conforming to MIL-C-0) Stations n 2 stations 4 6 7 9 10 11 1 14 1 16 stations 160. 1. 19 210. 2. 24 260. 27 29 2 4 60. 7 9 410. 10. 200 22 27. 20 262. 27.. 7. 0 62. 7. 400 4 100 116 12 14 164 10 196 2 246 262 27 294 10 26 11. 16. 1. 16. 16. 1. Two SU/EXH blocks are provided for models with 11 stations or more. 1-4-17

DC 24V 6 7 1 4 14 2 1 1 0 11 10 9 SMC ase Mounted SY000/000 DIN ail Manifold Exploded View 4-N Type D olts y i u o + - t!0 r q a olts w w e C release button b lock separation button eplacement arts No. Description SY000 art no. SY000 Note SY000 (Metric size) (Inch size) C4: With for ø4 N: With for ø 2" C6: With for ø6 N7: With for ø 1 4" Manifold block q For SY000 000-0-1-000-0-1- assembly (Metric size) (Inch size) C4: With for ø4 N: With for ø 2" C6: With for ø6 N7: With for ø 1 4" C: With for ø N9: With for ø 16" (Gasket 10 is supplied as an accessory.) (Metric size) (Metric size), port SY000 (Metric size) With for ø w SU/EXH block 000-1-1 000-1-1 (Inch size) With for ø 16" assembly (Inch size) (Inch size), port SY000 (Metric size) With for ø10 000-1-1 000-1-1 (Inch size) With for ø " e End block assembly 000-2-1 000-2-1 For r End block assembly L 000--1 000--1 For t Connector box VZ000-106-1 For 24 VDC only y ail stopper TXE1-SMC Made by Kasuga Electric Works, Ltd. SY000-4-1- SY000-4-2- +COM Type D, 2 to stations Type U, 9 to 16 stations u i o!0!1 Connector assembly SY000-4-2- SY000-4-1N- SY000-4-2N- SY000-4-- SY000-4-2N- SY000-4-N- Dust cap VZ000-6-2 ound head M x 26, SY000-2-4 combination screw Matt nickel plated Gasket 000-7-4 000-7-6 VZ1000-11-1- +COM COM COM Type D, 9 to 16 stations Type U, 2 to stations Type D, 2 to stations Type U, 9 to 16 stations Type D, 9 to 16 stations Type U, 2 to stations efer to page 1-4-.!1 1-4-1

ase Mounted SY000/000 How to Increase Manifold ase Station expansion is possible at any position. 1 Loosen bolt a fixing the manifold base until it begins to turn idly. (While pressing releasing buttons c, at two locations, separate the manifold base from the.) 2 4 ress manifold block assembly dividing button b, that are at the location where manifold bases are to be added, until button b locks, and then separate the block assemblies. Mount additional manifold block assembly on the as shown in the Fig. (1). ress the block assemblies until a click sound is produced, and tighten the bolts a to fix them to the. Caution (Tightening torque: 1.4 N m) (While lightly holding the blocks after fixing an end block on one side, tighten the other end block for better sealing.) Untighten the rail stopper bolt d to demount the connector box from the, and when remounting it, tighten the bolt while pressing it against the rail. Caution Note 1) When there are 10 or fewer manifold block assemblies, and more are added to make a total of 11 or more, a supply/exhaust block assembly must also be added. Note 2) When disassembly and assembly are performed, air leakage may result if connections between blocks and tightening of the end block s holding screw, is inadequate. efore supplying air, confirm that there are no gaps, etc. between blocks, and that manifold blocks are securely fastened to the. Then supply air and confirm that there is no air leakage before operating. Note ) One connector assembly is necessary for one solenoid. When a number is necessary for the connector assembly mark tube, suffix the number to the part no. (0 to 1 are provided as mark tube numbers.) Ex) +COM spec.: D type for 2 to stations: No. 10 SY000-4-1-10 How to Change Fitting ssembly Fig. (1) lock mounting procedure Hook the here and press down in the direction of the arrow until a click sound is heard. SV SZ SY SYJ Type 4 manifold permits change in the and port sizes by changing the manifold block fitting assembly. fter removing the valve, remove the clip with a screwdriver, etc. For mounting a new fitting assembly, insert it and then insert a clip until it will not come out of the manifold block. Fitting ssembly art No. Metric size SY000 for ø4 VVQ1000-0-C4 for ø6 VVQ1000-0-C6 for ø4 VVQ1000-1-C4 SY000 for ø6 VVQ1000-1-C6 for ø VVQ1000-1-C Inch size SY000 for ø 2 " VVQ1000-0-N for ø1 4 " VVQ1000-0-N7 SY000 for ø 2 " for ø1 4 " VVQ1000-1-N VVQ1000-1-N7 for ø 16 " VVQ1000-1-N9 Note 1) and ports cannot be changed. Note 2) Use caution that O-rings must be free from scratches and dust. Otherwise, air leakage may result. O ring Clip Fitting assembly 1-4-19

Type4 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted lug-in How to Order Manifold Type 4F (D-sub connector, 2 pins) SSY 4 F D 0 U SY000 SY000 Common specifications Nil ositive common N Negative common Connector mounting position Symbol Mounting position U D C4 How to Order Valve Manifold ssembly Example (Type 4F/D-sub connector (2 pins)) Double solenoid (24 VDC) SY24-FU (1 set) Stations..2 1 Single solenoid (24 VDC) SY140-FU (2 sets) lanking plate assembly 000-7-2 (1 set) Symbol Stations 02 2 stations 20 20 stations Valve stations Note Single wining spec. (pplicable up to 20 solenoid valves.) This also includes the number of blanking plate assemblies. Two stations are necessary for the double, position (Dual body type). SU/EXH block assembly mounting position Symbol Mounting position Stations U D 2 to 10 stations 2 to 10 stations (oth sides) 2 to 20 stations M Special specifications For special specifications, indicate separately on the manifold specification sheet. (Metric size) Symbol ort size pplicable series for ø4 for ø6 Mixed SY000 C4 C6 M C4 C6 C M for ø4 for ø6 SY000 for ø Mixed, port size (Inch size) Symbol ort size pplicable series N for ø 2 " N7 for ø1 4 " SY000 M Mixed N for ø 2 " N7 for ø1 4 " N9 for ø 16 " SY000 M Mixed In the case of mixed specifications (M), indicate separately on the manifold specification sheet. Voltage Nil 24 VDC V VDC Option When a longer is desired than the specified stations, specify the station number to be required. (20 stations at maximum) For external pilot and built-in silencer, refer to page 1-4-197. SSY-4FD-0U-C6 1 set (Type 4F, D-sub connector port manifold base part no.) 000-7-2 1 set (lanking plate assembly part no) SY140-FU 2 sets (Single solenoid part no.) SY24-FU 1 set (Double solenoid part no.) The asterisk denotes the symbol for assembly. refix it to the part nos. of the solenoid valve, etc. The valve arrangement is numbered as the 1st. station from regardless of the mounting position of connector box. When ordering double solenoid valves/ position (Dual body type), please keep in mind that they require two manifold stations. How to Order Valves (Type 4F, 4, 4T, 4T1) 2 position single Double, position SY 1 4 0 FU SY 2 SY000 SY000 Type of actuation 2 2 position double position closed center 4 position exhaust center position pressure center 4 Dual body type (Double, position) ated 24 VDC 6 VDC Nil D E Manifold base ( stations) SSY-4FD-0D-C6 FU Non-locking push type ush-turn locking slotted type ush-turn locking lever type 1-4-140

ase Mounted SY000/000 How to Order Manifold Type 4 (Flat ribbon cable) SSY 4 D 0 U C4 Option When a longer is desired than the specified stations, specify the station number to be required. (20 stations at maximum) SY000 Voltage SY000 Nil 24 VDC Common specifications, port size V VDC Nil ositive common (Metric size) (Inch size) N Negative common Symbol ort size pplicable series Symbol ort size pplicable series C4 for ø4 N for ø 2 " Connector poles C6 for ø6 SY000 N7 for ø1 4 " SY000 Symbol oles Stations M Mixed M Mixed Nil 26 2 to 20 stations C4 for ø4 N for ø 2 " G 20 2 to 16 stations C6 for ø6 N7 for ø1 4 " SY000 SY000 H 10 2 to stations C for ø N9 for ø 16 " M Mixed M Mixed In the case of mixed specifications, indicate separately on the manifold Connector mounting position specification sheet. Symbol Mounting position SU/EXH block assembly mounting position U Symbol Mounting position Stations D U 2 to 10 stations D 2 to 10 stations oth sides 2 to 20 stations M Special specifications For special specifications, indicate separately Valve stations (lanking plate assemblies are included.) by the manifold specification sheet. 26 pins () connector 20 pins (G) connector 10 pins (H) connector Symbol Stations Note Symbol Stations Note Symbol Stations Note 02 2 stations Single wiring spec. 02 2 stations Single wiring spec. 02 2 stations Single wiring spec. (pplicable up to 20 (pplicable up to 16 (pplicable up to 20 20 stations solenoid valves.) 16 16 stations solenoid valves.) 0 stations solenoid valves) Two stations are necessary for the double, position (Dual body type). SV SZ SY SYJ Type 4T (9 pins terminal block) SSY 4T D 0 U C4 Type 4T1 (1 pins terminal block) SSY 4T1 D 1 C4 SY000 SY000 Terminal block mounting position Symbol Mounting position U D Valve stations Symbol 02 Stations 2 stations Note Single wiring spec. 0 (pplicable up to solenoid valves) stations This also includes the number of blanking plate assemblies. Two stations are necessary for the double, position (Dual body type). SU/EXH block assembly mounting position Symbol Mounting position Stations U D 2 to stations 2 to stations oth sides 2 to stations M Special specifications For special specifications, indicate separately by the manifold specification sheet. Option When a longer is desired than the specified stations, specify the station number to be required., port size (Metric size) Symbol ort size pplicable series C4 C6 M C4 C6 C M for ø4 for ø6 Mixed SY000 for ø4 for ø6 SY000 for ø Mixed (Inch size) Symbol ort size pplicable series N for ø 2 " N7 for ø1 4 " SY000 M Mixed N for ø 2 " N7 for ø1 4 " N9 for ø 16 " SY000 M Mixed In the case of mixed specifications (M), indicate separately on the manifold specification sheet. SY000 SY000 Terminal block mounting position Symbol Mounting position U D Valve stations Symbol 02 Stations 2 stations Note Single wining spec. (pplicable up to solenoid valves.) stations This also includes the number of blanking plate assemblies. Two stations are necessary for the double, position (Dual body type). SU/EXH block assembly mounting position Symbol Mounting position Stations U D 2 to 10 stations 2 to 10 stations oth sides 2 to stations M Special specifications For special specifications, indicate separately by the manifold specification sheet. Option When a longer is desired than the specified stations, specify the station number to be required., port size (Metric size) Symbol ort size pplicable series C4 for ø4 C6 for ø6 SY000 M Mixed C4 for ø4 C6 for ø6 SY000 C for ø M Mixed (Inch size) Symbol ort size pplicable series N for ø 2 " N7 for ø1 4 " SY000 M Mixed N for ø 2 " N7 for ø1 4 " SY000 N9 for ø 16 " M Mixed In the case of mixed specifications (M), indicate separately on the manifold specification sheet. Note) The terminal block (4T ) manifold has no common polarity. It can be used for both positive and negative common. 1-4-141

ase Mounted SY000/000 How to Order Manifold Type 4G (Flat cable, C wiring system compatible) SSY 4G D 0 U C4 SY000 SY000 Connector mounting position Symbol Mounting position U D Valve stations Symbol Stations Note 02 2 stations Single wining spec. 16 16 stations (pplicable up to 16 solenoid valves.) Two stations are necessary for the double, position (Dual body type). This also includes the number of blanking plate assemblies. SU/EXH block assembly mounting position Symbol U D M Mounting position Stations 2 to 10 stations 2 to 10 stations oth sides 2 to 16 stations Special specifications For special specifications, indicate separately on the manifold specification sheet. Option When a longer is desired than the specified stations, specify the station number to be required. (20 stations at maximum), port size (Metric size) Symbol ort size pplicable series for ø4 for ø6 SY000 Mixed C4 C6 M C4 C6 C M for ø4 for ø6 SY000 for ø Mixed In the case of mixed specifications, indicate separately on the manifold specification sheet. SU/EXH block assembly specifications Symbol Nil S S (Inch size) Symbol ort size pplicable series N N7 for ø 2 " for ø1 4 " SY000 M N Mixed for ø 2 " N7 for ø1 4 " N9 for ø 16 " SY000 M Mixed Specifications Internal pilot External pilot Internal pilot/uilt-in silencer External pilot/uilt-in silencer 1-4-142

ase Mounted SY000/000 D-sub connector Flat ribbon cable Terminal block Manifold Option Manifold Specifications Model Manifold (SU)/ (EXH) Valve stations Note 1, 2), port Location orting specifications Direction ort size, port, port pplicable connector SY000 SY000 SY000 SY000 Internal wiring Manifold base weight w (g) SY000 n: Stations (D-sub connector) SY000 D-sub connector Type 4F Flow Characteristics Model 1,, (, E, E) SSY-4 SSY-4 C C10 ort size Flat ribbon cable Type 4 Terminal block Type 4 Type 4G Type 4H Type 4T Type 4T1 Type 4G lug-in Common SU, Common EXH Flat ribbon cable C wiring system compatible 2 to 20 stations 2 to 16 stations 2 to stations 2 to stations 2 to 16 stations ase Side C ( for ø) C10 ( for ø10) C4 ( for ø4)/c6 ( for ø6) C4 ( for ø4)/c6 ( for ø6)/c ( for ø) D-sub connector Complies with MIL-C-240 JIS-X-101 Terminal block (M) 9 pins Terminal block (M) 1 pins +COM (Type 4 ), COM (Type 4N ) In common between +COM and COM. + COM 2 to 10 stations: W = 26n + 2 11 to 20 stations: W = 26n + 199 2 to 10 stations: W = 4n + 227 11 to 20 stations: W = 2n + 264 4, 2 (, ) C6 C Flat ribbon cable connector Socket: 26 pins MIL type with strain relief Conforming to MIL-C-0 Flat ribbon cable connector Socket: 20 pins MIL type with strain relief Conforming to MIL-C-0 Flat ribbon cable connector Socket: 10 pins MIL type with strain relief Conforming to MIL-C-0 Flow characteristics 1 4/2 ( /) 4/2 / (/ E/E) C (dm /(s bar)) b Cv C (dm /(s bar)) b Cv 0. 2.2 0.21 0.24 0.22 0. 0.9 2. 0.1 0.1 0.22 0. Note) The value is for manifold base with stations and individually operated 2 position type. Flat ribbon cable connector Socket: 20 pins MIL type with strain relief Conforming to MIL-C-0 Note 1)For more than 11 stations, supply pressure to port on both sides and exhaust from port on both sides. Note 2)There is a limit depending on the number of solenoids. efer to How to Order. SV SZ SY SYJ lanking plate assembly Note) Short cap SU block disk y installing a SU block disk in the pressure supply passage of a manifold valve, it is possible to supply two or more different high and low pressures to one manifold. Label for block disk The labels shown below are used on manifold stations containing SU/EXH block disk(s) to show their location. ( pcs. each) VZ000--1 (In common with SY000/000) Label for SU block disk Label for EXH block disk Label for SU/EXH block disk SY000 SY000 ssembly part no. 000-7-2 000-76-6 Note) When mounting blanking plate, be sure to mount a short cap. Two stations are necessary for the double, position (Dual body type). Caution Mounting screw tightening torques M2: 0. N m M: 0. N m M4: 1.4 N m SY000 SY000 EXH block disk art no. 000-77-1 000-77-1 y installing an EXH block disk in the exhaust passage of a manifold valve, it is possible to divide the valve s exhaust so that it does not affect another valve. (Two block disks are needed to divide both exhausts.) SY000 SY000 art no. 000-77-1 000-77-1 Note) When a block disk is concurrently ordered by specifying on the manifold specification sheet, etc., a label will be stuck on the position where block disk is mounted. Silencer with The silencer plugs directly into the Onetouch fittings of the manifold. For SY000 (ø) For SY000 (ø10) lug (white) These are inserted in unused cylinder ports and SU, EXH ports. urchasing order is available in units of 10 pieces. Dimensions pplicable fittings size ød 4 Model N20-KM N200-KM10 N00-KM10 Effective area 14 mm 2 26 mm 2 0 mm 2 ø16 ø22 ø2 26. 70 C 1 0. 97 Model L D KQ2-04 16 2 6 6 KQ2-06 1 KQ2-0 20. 9 10 10 KQ2-10 22 4 1 " 2 " 1 4 " 16 " ød ød KQ2-01 16 1. KQ2-0 16 2 6 KQ2-07 1. KQ2-09 20. 9 10 C L 1-4-14

ase Mounted SY000/000 Manifold Option D-sub connector (2 pins)/cable assembly XT100-DS2-01 00 00 L 47.04 Terminal no. 1 1 16 14 2 D-sub Connector Cable Cable length (L) 1. m m m Socket side ssembly part no. XT100-DS2-01 XT100-DS2-00 XT100-DS2-00 Connector manufacturers example Hirose Electric Co., Ltd. Fujitsu Limited Japan viation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Note Cable 2 core x 24 WG When a commercially available connector is required, use a 2 pin female connector conforming to MIL-C240. Electric Characteristics Flat ibbon Cable Connector/Cable assembly 44 2-M2.6 x 0.4 pprox. ø10 Multi-core vinyl cable 0. mm 2 x 2C Item Characteristics Conductor resistance Ω/km, 20 C 6 or less Voltage limit V, 1 min, C 1000 Insulation resistance MΩkm, 20 C or more Note) The min. bending radius of D-sub cable assembly is 20 mm. D-sub Connector Cable ssembly Terminal No. Terminal no. Lead wire color Dot marking 1 lack None 2 rown None ed 4 Orange Yellow 6 ink 7 lue None None None None None urple White 9 Gray lack 10 White lack 11 White ed Yellow ed 1 Orange ed 14 Yellow lack 1 ink lack 16 lue White urple None 1 Gray None 19 Orange lack 20 ed White 21 rown White 22 ink ed 2 Gray ed 24 lack White 2 White None Dimensions/ XT100-FC - 1 to Triangle mark position ed VZ1000 11 1 efer to L dimensions Fill in with an appropriate no. listed on the table of dimensions shown below. W L Terminal number L Flat ibbon Cable ssembly Cable length (L) 1. m m m Connector width (W) 10 pins XT100-FC10-1 XT100-FC10-2 XT100-FC10-.2 20 pins XT100-FC20-1 XT100-FC20-2 XT100-FC20-0 Connector manufacturers example Hirose Electric Co., Ltd. Sumitomo M Limited Fujitsu Limited Japan viation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. 26 pins XT100-FC26-1 XT100-FC26-2 XT100-FC26-7. For other commercial connectors, use a type with strain relief that conform to MIL-C-0. No. L Dimension No. L Dimension No. L Dimension No. L Dimension No. L Dimension No. L Dimension No. L Dimension 0 9 11 2. 22 7 10. 44 64 7. 66 92 1 110. 24 2. 4 2 4 660. 6 79 67 9. 2 1 260. 24 9. 46 67 7 10. 6 94 1. 14 27 2 410. 6 4 47 6. 2 69 960. 4 14 1 2. 26 42 7 60. 4 69 9. 70 97 160. 16 29 27 4. 7 49 710. 60 4 71 9. 6 10. 2 44 9. 0 72 61 60. 7 1. 1 2 29 460. 40 9 1 7. 62 7 19 19. 0 47 41 610. 2 74 6. 9 210. 20 4 1 4. 42 62 760. 64 9 10 22 21 60. 2 49 4 6. 4 77 6 910. efer to dimension on pages starting with page 1-4-10 for lengths that correspond to the number of manifold stations. 1-4-144

ase Mounted SY000/000 Manifold Internal Wiring Type 4(N)F: D-sub Connector D-sub connector used for electric wiring reduces labor during wiring operation. Connectors conforming to MIL are used for interchangeability. Stations 2 1 <For positive common (4F)> ositive pole (common) Negative ole Not use Station 20 Station SOL. Station 4 SOL. (Double solenoid Dual body type) Station (Single solenoid) Station 2 (Single solenoid) Station 1 (Single solenoid) } <For negative common (4NF)> ositive pole Negative ole (common) Not use Station 20 Station SOL. Station 4 SOL. (Double solenoid Dual body type) Station (Single solenoid) Station 2 (Single solenoid) Station 1 (Single solenoid) } SV SZ SY SYJ ower supply terminal ower supply terminal The power source terminal is used for connecting to an external power source. The maximum number of stations that can be accommodated is 20 manifold stations, with up to 22 solenoids. (For more stations, please contact SMC.) egardless of the connector mounting position, stations are to be counted from as the 1st one. Type 4(N): Flat ibbon Cable (26 pins) flat cable connector used for electric wiring reduces labor during wiring operation. Connectors conforming to MIL are used for interchangeability. <For positive common (4)> ositive pole (common) Negative pole Not use Station 20 <For negative common (4N)> ositive pole Negative pole (common) Not use Station 20 Stations. 2 1 Station SOL. (Double solenoid Station 4 SOL. Dual body type) Station (Single solenoid) } Station SOL. (Double solenoid Station 4 SOL. Dual body type) Station (Single solenoid) } Station 2 (Single solenoid) Station 1 (Single solenoid) Triangle mark Station 2 (Single solenoid) Station 1 (Single solenoid) Triangle mark ower supply terminal ower supply terminal Triangle mark eference figure Note) Terminal no. is not indicated on the connector. The terminal no. indicated in the connection schematic of connector, as shown in the reference, means a correlation of 1, 2, 26 from the triangle mark side on the flat ribbon cable of connector. The power source terminal is used for connecting to an external power source. The maximum number of stations that can be accommodated is 20 manifold stations, with up to 20 solenoids. (For more stations, please contact SMC.) egardless of the connector mounting position, stations are to be counted from as the 1st one. 1-4-14

ase Mounted SY000/000 Manifold Internal Wiring Type 4(N)G: Flat ibbon Cable (20 pins) flat cable connector used for electric wiring reduces labor during wiring operation. Connectors conforming to MIL are used for interchangeability. <For positive common (4G)> <For negative common (4NG)> ositive pole (common) Negative pole Station 16 ositive pole Negative pole (common) Station 16 Stations 2 1 Station SOL. (Double solenoid Station 4 SOL. } Dual body type) Station (Single solenoid) Station SOL. (Double solenoid Station 4 SOL. Dual body type) Station (Single solenoid) } Station 2 (Single solenoid) Station 1 (Single solenoid) Triangle mark Station 2 (Single solenoid) Station 1 (Single solenoid) Triangle mark ower supply terminal ower supply terminal Triangle mark eference figure Note) Terminal no. is not indicated on the connector. The terminal no. indicated in the connection schematic of connector, as shown in the reference, means a correlation of 1, 2, 20 from the triangle mark side on the flat ribbon cable of connector. The power source terminal is used for connecting to an external power source. The maximum number of stations that can be accommodated is 16 manifold stations, with up to 16 solenoids. (For more stations, please contact SMC.) egardless of the connector mounting position, stations are to be counted from as the 1st one. Type 4(N)H: Flat ibbon Cable (10 pins) flat cable connector used for electric wiring reduces labor during wiring operation. Connectors conforming to MIL are used for interchangeability. <For positive common (4H)> <For negative common (4NH)> ositive pole (common) Negative pole Station ositive pole Negative pole (common) Station Station SOL. (Double solenoid Station 4 SOL. Dual body type) Station (Single solenoid) } Station SOL. Station 4 SOL. (Double solenoid Dual body type) Station (Single solenoid) } Stations. 2 1 Station 2 (Single solenoid) Station 1 (Single solenoid) Triangle mark Station 2 (Single solenoid) Station 1 (Single solenoid) Triangle mark Triangle mark eference figure Note) Terminal no. is not indicated on the connector. The terminal no. indicated in the connection schematic of connector, as shown in the reference, means a correlation of 1, 2, 10 from the triangle mark side on the flat ribbon cable of connector. ower supply terminal ower supply terminal The power source terminal is used for connecting to an external power source. The maximum number of stations that can be accommodated is manifold stations, with up to solenoids. (For more stations, please contact SMC.) egardless of the connector mounting position, stations are to be counted from as the 1st one. 1-4-146

ase Mounted SY000/000 Manifold Internal Wiring Type 4T: Terminal lock terminal block style permits direct cable connection without treatment of lead wires. (4T) Station SV Station SOL. Station 4 SOL. } (Double solenoid Dual body type) SZ SY Stations 2 1 Station (Single solenoid) SYJ Station 2 (Single solenoid) Station 1 (Single solenoid) Common (+, ) The maximum number of stations that can be accommodated is manifold stations, with up to solenoids. (For more stations, please contact SMC.) egardless of the connector mounting position, stations are to be counted from as the 1st one. There is no polarity in the COM wiring. Supply positive power for +COM spec. and negative power for COM spec. Type 4T1: Terminal lock (4T1) Station Station Stations 2 1 Station SOL. Station 4 SOL. } (Double solenoid Dual body type) Station (Single solenoid) Station 2 (Single solenoid) Station 1 (Single solenoid) Station 9 Common (+, ) The maximum number of stations that can be accommodated is manifold stations, with up to solenoids. (For more stations, please contact SMC.) egardless of the connector mounting position, stations are to be counted from as the 1st one. There is no polarity in the COM wiring. Supply positive power for +COM spec. and negative power for COM spec. 1-4-147

ase Mounted SY000/000 Manifold Internal Wiring Type 4G: Flat ibbon Cable (C Wiring System compatible) It s the manifold for 20 pins flat ribbon cable connector which is compliant for C wiring system. 24VDC +COM + Stations 2 1 - CW type SMC Electric circuit diagram (elow wiring is the case of all double solenoid connections.) Cable connector for flat ribbon cable Connector terminal number Triangle mark position 1 station { 2 stations { stations { 4 stations { stations { 6 stations { 7 stations { stations { Terminal no. SOL. 20 SOL. 1 SOL. 16 SOL. 14 SOL. SOL. 10 SOL. SOL. 6 SOL. 19 SOL. SOL. 1 SOL. 1 SOL. 11 SOL. 9 SOL. 7 SOL..4 24 VDC + 1.2 The maximum number of stations that can be accommodated is 16 manifold stations, with up to 16 solenoids. (For more stations, please contact SMC.) egardless of the connector mounting position, stations are to be counted from as the 1st one. For details about the C wiring system, refer to catalog CT.ES02-20 separately. 1-4-14

ase Mounted SY000/000 How to Connect SSY -4 (lug-in) ower terminal is equipped with plug-in manifold of SY as standard. ower terminal enables the power supply to valve from either of manifold or controller side. 1. Wiring example when using manifold power supply terminals LC SY manifold internal wiring (Flat ribbon cable, plus common specifications) Negative pole Controller side (LC, etc.) (NN open collector output) SV SZ SY Manifold valve (SSY-4GD-0U- ) SYJ DC power supply Solenoid valve ower supply terminal Triangle mark Cable assembly XT100-FC20-, etc. ower supply 2. Wiring example when not using manifold power supply terminals (ower is supplied to the controller side or along the wiring, etc.) LC SY manifold internal wiring (Flat ribbon cable, plus common specifications) ositive pole ower supply Controller side (LC, etc.) (NN open collector output) Manifold valve (SSY-4GD-0U- ) DC power supply Solenoid valve ower supply terminal Triangle mark Cable assembly XT100-FC20-, etc. Caution Single wire, COM position, etc. of LC are different from each manufacturer. When connecting with LC, read the specifications carefully and understand the electrical circuit. oor wiring could cause damage to LC, power source, etc. as well as manifold and valve. 1-4-149

ase Mounted SY000/000 SY000: D-sub Connector/lug-in SSY-4FU- Stations D- (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 1. Equivalent to the applicable D-sub connector {JIS-X-101, MIL-C-240} 114. 110.4 19.4 41.2. Terminal no. 1 ower supply terminals The indication marking is for 24 VDC. SSY-4FU- Stations - 27 24VDC +COM - + M2.6 (Station n) (Light/Surge ) 71.1 47.7 M Terminal screw (itch) = 16 26 (.) (ail mounting hole pitch:.) 7 47 (Station 1) utton for release 2 (, port) pplicable tubing O.D.: ø10, ø/" () (itch) = 16 26 1.2 7. holding screw 42.7 lock separation button (ush type) Depress and turn to operate and lock override. side: Orange side: Green utton for release Note) The to dimensions of SSY-4FU- Stations U- are identical to those of SSY-4FU- Stations D-. Stations n 2 stations 4 6 7 9 10 stations 1.14 160.1.19 210.2.24 260. 17.10.200 22 27.20 10 1 17 1 169 1 201 2 2 1 1. 11. 16. 1. 2 1. (, port) pplicable tubing O.D.: ø10, ø/" Equivalent to the applicable D-sub connector {JIS-X-101, MIL-C-240} 27 114. 19.4 41.2 110.4. Terminal no. 1 24VDC +COM - + M2.6 ower supply terminals The indication marking is for 24 VDC. (.) ress and turn to operate ( and lock override. ) side: Orange side: Green (ail mounting hole pitch:.) (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" () 1.2 holding screw Stations n 2 stations 4 6 7 9 10 stations 14 1.19 210.2.24 260.2. 17.162..200 22 27.20 27 19 1 1 20 219 2 21. 1 1. 11. 16. Stations n 11 stations 1 14 1 16 1 19 20 stations 29 10.2 4 60.7 9 410.42 4. 27.00.7.0 62.7.400 4.42 267 2 299 1 1 47 6 79 9 411 1. 16. 1. 14 1-4-

ase Mounted SY000/000 SY000: D-sub Connector/lug-in SSY-4FD- Stations U- 26 (itch) 46 = 16 utton for release 2 1. (, port) pplicable tubing O.D.: ø10, ø/" holding screw 114. 1.2. (.) (, port)pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 2 () 19.4 41.2 110.4 Equivalent to the applicable D-sub connector {JIS-X-101, MIL-C-240} Note) The to dimensions of SSY-4FD- Stations D- are identical to those of SSY-4FD- Stations U-. SV SZ SY SYJ 24VDC +COM - + ress and turn to operate ( and lock override. ) side: Orange side: Green (Station n) (Light/Surge ) 71.1 42.7 Terminal no. 1 M2.6 (ail mounting hole pitch:.) (Station 1) 7 M Terminal screw 7. 47.6 ower supply terminals The indication marking is for 24 VDC. Stations n 2 stations 1. 10 1 4 6 7 9 10 stations 160. 1. 19 210. 2. 24 260. 10. 200 22 27. 20 17 11. 1 16 169 1. 201 2 2 1. 14 17. 1 1. SSY-4FD- Stations - 1. (, port) pplicable tubing O.D.: ø10, ø/" holding screw 114. 1.2 ress and turn to operate and lock override. side: Orange side: Green 26 (itch) 47 = 16 (.) 24VDC +COM - Terminal no. 1 M2.6 (ail mounting hole pitch:.) + lock separation button (ush type) utton for release 2 (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" () Equivalent to the applicable D-sub connector {JIS-X-101, MIL-C-240} 2. 41.2 19.4 110.4 Stations n Stations n ower supply terminals The indication marking is for 24 VDC. 2 stations 14 17.. 11 stations 29 27. 267 4 6 7 9 10 stations 1. 19 210. 2. 24 260. 2.. 200 22 27. 20 27 1 1 1 1. 11. 20 16 219 2. 21 162. 19 10. 00 2 1. 1 14 1 16 1 19 20 stations 4 60. 7 9 410. 42 4. 7. 0 62. 7. 400 4. 42 1 16. 1 47 1 6. 79 9 14 411 2. 299 1-4-1

ase Mounted SY000/000 SY000: Flat ibbon Cable/lug-in SSY-4U- Stations D- (26 pins) (itch) = 16 26 utton for release (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" pplicable connector: 26 pins MIL type With strain releaf (Conforming to MIL-C-0) 2.9 (, port) pplicable tubing O.D.: ø10, ø/" holding screw pplicable connector: 20 pins MIL type (Conforming to MIL-C-0) pplicable connector: 10 pins MIL type (Conforming to MIL-C-0) Triangle mark position Triangle mark position 24VDC +COM + 24VDC +COM + 24VDC +COM + (Light/Surge ) (Station n) (Station 1) Type 4G (20 pins) Type 4H (10 pins) M Terminal screw SSY-4U- Stations - 47 (26 pins) (itch) = 16 26 utton for release 2 1. 1. 2 (.) () Note) The to dimensions of SSY-4 U- Stations U- are identical to those of SSY-4 U- Stations D-. 41.2 114. 110.4 19.4. 1.2 ower supply terminals The indication marking is for 24 VDC. Triangle mark position (ail mounting hole pitch:.) Depress and turn to operate ( and lock override. ) side: Orange side: Green 71.1 47.7 7 7. 42.7 lock separation button (ush type) Stations n 2 stations 4 6 7 9 10 stations 1.14 160.1.19 210.2.24 260. 17.10.200 22 27.20 10 1 17 1 169 1 201 2 2 1 1. 11. 16. 1. (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" pplicable connector: 26 pins MIL type With strain releaf 2.9 (Conforming to MIL-C-0) 41.2 114. 110.4 19.4. ower supply terminals The indication marking is for 24 VDC. 24VDC +COM + (.) Triangle mark position (ail mounting hole pitch:.) (, port) pplicable tubing O.D.: ø10, ø/" () holding screw 1.2 ress and turn to operate ( and lock override. ) side: Orange side: Green Stations n 2 stations 4 6 7 9 10 stations 14 1.19 210.2.24 260.2. 17.162..200 22 27.20 27 19 1 1 20 219 2 21. 1 1. 11. 16. Stations n 11 stations 1 14 1 16 1 19 20 stations 29 10.2 4 60.7 9 410.42 4. 27.00.7.0 62.7.400 4.42 267 2 299 1 1 47 6 79 9 411 1. 16. 1. 14 1-4-16

ase Mounted SY000/000 SY000: Flat ibbon Cable/lug-in SSY-4D- Stations U- 2 (26 pins) 26 (itch) 46 = 16 utton for release 1. (, port) pplicable tubing O.D.: ø10, ø/" holding screw 114. 1.2. (.) 2 (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" () 41.2 pplicable connector: 26 pins MIL type With strain releaf (Conforming to MIL-C-0) 19.4 110.4 Triangle mark position Note) The to dimensions of SSY-4 D- Stations D- are identical to those of SSY-4 D- Stations U-. SV SZ SY SYJ 24VDC +COM + ress and turn to operate ( and lock override. ) (ail mounting hole pitch:.) side: Orange side: Green (Station n) (Station 1) (Light/Surge ) 71.1 42.7 SSY-4D- Stations - 26 (itch) = 16 (26 pins) utton for release 1. 2 M Terminal screw 7. 47.6 ower supply terminals The indication marking is for 24 VDC. Stations n 2 stations 1. 10 1 4 6 7 9 10 stations 160. 1. 19 210. 2. 24 260. 10. 200 22 27. 20 17 11. 1 16 169 1. 201 2 2 1. 14 17. 1 1. 47 lock separation button (ush type) (, port) pplicable tubing O.D.: ø10, ø/" holding screw 114. 1.2 ress and turn to operate and lock override. side: Orange side: Green (.) 24VDC +COM Triangle mark position (ail mounting hole pitch:.) + (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 2 () pplicable connector: 26 pins MIL type With strain releaf (Conforming to MIL-C-0). 41.2 19.4 110.4 ower supply terminals The indication marking is for 24 VDC. Stations n Stations n 2 stations 14 17.. 11 stations 29 27. 267 4 6 7 9 10 stations 1. 19 210. 2. 24 260. 2.. 200 22 27. 20 27 1 1 1 1. 11. 20 16 219 2. 21 162. 19 10. 00 2 1. 1 14 1 16 1 19 20 stations 4 60. 7 9 410. 42 4. 7. 0 62. 7. 400 4. 42 1 16. 1 47 1 6. 79 9 14 411 2. 299 1-4-

7 6 4 2 1 COM 7 6 4 2 1 COM ase Mounted SY000/000 SY000: 9 ins Terminal lock/lug-in SSY-4TU- Stations D- (9 pins) (itch) =16 26 utton for release 1. 2 (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 6 114.. 27. COM 1 2 4 6 7 M Terminal screw (.) (, port) pplicable tubing O.D.: ø10, ø/" () holding screw 41.2 1.2 110.4 Note) The to dimensions of SSY-4TU- Stations U-, SSY-4TD- Stations U-, SSY-4TD- Stations D- of SSY-4TU- Stations D-. are identical those SV SZ SY SYJ ress and turn to operate and lock override. side: Orange side: Green (ail mounting hole pitch:.) (Station n) (Station 1) (Light/Surge ) SSY-4TU- Stations - 2 114. 71.4. 27. 47 (9 pins) COM 1 2 4 6 7 (itch) =16 M Terminal screw lock separation button (ush type) 26 utton for release (.) 7. 42.7 71.1 1. 41.2 1.2 110.4 Stations n (, port) pplicable tubing O.D.: ø10, ø/" (, port) pplicable tubing O.D.: ø4, ø/2" () ø, ø/16" holding screw 2 stations 1. 10 1 4 6 7 stations 160. 1. 19 210. 2. 10. 200 22 17 11. 1 16 169 1. 201 14 17. 1 1. Note) The to dimensions of SSY-4TD- Stations - are identical to those of SSY-4TU- Stations -. ress and turn to operate and lock override. side: Orange side: Green (ail mounting hole pitch:.) Stations n 2 stations 14 17.. 4 6 7 stations 1. 19 210. 2. 24. 200 22 27. 1 1 1 1. 11. 20 16 219 162. 19 1-4-19

2 4 6 7 9 9 9 9 2 4 6 7 ase Mounted SY000/000 SY000: 1 ins Terminal lock/lug-in SSY-4T1U- Stations D- (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 1. (1 pins) utton for release (itch) =16 26 2 Note) The to dimensions of SSY-4T1U- Stations U- are identical to those of SSY-4T1U- Stations D-. 4. 27. (.) (, port) pplicable tubing O.D.: ø10, ø/" () 6 114. holding screw. 0.9 71.4 7 6 4 2 1 COM M Terminal screw COM 1 16 1 14 1 11 10 16 1 14 1 11 10 ress and turn to operate and lock override. side: Orange 1.2 41.2 110.4 Stations n 2 stations 160. 10 6 side: Green (ail mounting hole pitch:.) (Station n) (Station 1) (Light/Surge ) lock separation button (ush type) 7. 42.7 71.1 4 6 7 9 10 stations 1. 19 22 2. 24 27 2.. 2. 22 27. 262. 27 1 1. 4 190 16. 206 222 1 2. 24 162. 142 SSY-4T1U- Stations - (1 pins) 6 (itch) =16 26 utton for release 2 1. (, port) pplicable tubing O.D.: ø10, ø/" 4. 27. (.) (, port) pplicable tubing O.D.: ø4, ø/2" () ø, ø/16" 114.. 7 6 4 2 1 COM COM 1 16 1 14 1 11 10 16 1 14 1 11 10 1.2 41.2 110.4 Stations n 2 stations 162. 144 4 6 7 9 stations 210. 22 2. 24 27 2. 200 2. 22 27. 262. 27 6 192 20 1. 224 240 16. 26 1. 160 holding screw M Terminal screw ress and turn to operate and lock override. side: Orange side: Green (ail mounting hole pitch:.) Stations n 10 stations 29 27. 272 1 11 1 14 1 16 stations. 4 60.. 9 410. 2 7. 0 7 7. 400 04 20 14 6 2 16. 6 1 4 1 2. 2. 1-4-162

9 9 9 9 7 6 4 2 7 6 4 2 ase Mounted SY000/000 SY000: 1 ins Terminal lock/lug-in SSY-4T1D- Stations U- 42.7 holding screw 26 (, port) pplicable tubing O.D.: ø10, ø/" 114. 1.2. (.) (1 pins) (itch) 67 =16 16 1 14 1 11 10 16 1 14 1 11 10 4. 27. 7 6 4 2 1 COM COM 1 utton for release 1. (, port) pplicable tubing O.D.: ø4, ø/2" () ø, ø/16" 41.2 110.4 Note) The to dimensions of SSY-4T1D- Stations D- are identical to those of SSY-4T1D- Stations U-. SV SZ SY SYJ (Station n) (Light/Surge ) 71.1 42.7 7. M ress and turn to operate Terminal screw and lock override. side: Orange side: Green (ail mounting hole pitch:.) (Station 1) 71.4 0.9 6 Stations n 2 stations 160. 10 6 4 6 7 9 10 stations 1. 19 22 2. 24 27 2.. 2. 22 27. 262. 27 1 1. 4 190 16. 206 222 1 2. 24 162. 142 SSY-4T1D- Stations - 26 (itch) =16 (1 pins) 6 lock separation button (ush type) utton for release 1. 2 (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" holding screw (.) 4. 27. (, port) pplicable tubing O.D.: ø10, ø/" () 114. 1.2. M ress and turn to operate Terminal screw and lock override. side: Orange side: Green (ail mounting hole pitch:.) 16 1 14 1 11 10 16 1 14 1 11 10 7 6 4 2 1 COM COM 1 41.2 110.4 Stations n Stations n 2 stations 162. 144 10 stations 29 27. 272 1 4 6 7 9 stations 210. 22 2. 24 27 2. 200 2. 22 27. 262. 27 6 192 20 1. 224 240 16. 26 1. 160. 11 1 14 1 16 stations. 4 60.. 9 410. 2 7. 0 7 7. 400 04 20 14 6 2 16. 6 1 4 1 2. 2. 1-4-16

ase Mounted SY000/000 SY000: C Wiring System Compatible (Flat ribbon cable/lug-in) SSY-4GU- Stations D- (itch) = 16 26 utton for release 1. (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" G 2 (, port) pplicable tubing O.D.: ø10, ø/" Note) The to dimensions of SSY-4GU- Stations U- are identical to those of SSY-4GU- Stations D-. pplicable connector: 20 pins MIL type With strain releaf (Conforming to MIL-C-0) 2.9 (.) () holding screw CW type 114. 110.4 41.2 2.2. 1.2 ower supply terminals The indication marking is for 24 VDC. 24VDC +COM - + Triangle mark position (ail mounting hole pitch:.) ress and turn to operate and lock override. side: Orange side: Green (Light/Surge ) 71.1 47.7 M Terminal screw (Station n) 7 (Station 1) 7. 42.7 Stations n 2 stations 4 6 7 9 10 stations 1. 14 160. 1. 19 210. 2. 24 260. 17. 10. 200 22 27. 20 10 1 17 1 169 1 201 2 2 1 1. 11. 16. 1. SSY-4GU- Stations - 47 (itch) = 16 26 utton for release 2 1. lock separation button (ush type) pplicable connector: 20 pins MIL type With strain releaf (Conforming to MIL-C-0) 2.9 41.2 114. 110.4 2.2. ower supply terminals The indication marking is for 24 VDC. G 24VDC +COM - + (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" Triangle mark position (.) (ail mounting hole pitch:.) (, port) pplicable tubing O.D.: ø10, ø/" () holding screw Stations n 2 stations 4 6 7 9 10 stations 14 1. 19 210. 2. 24 260. 2. 17. 162.. 200 22 27. 20 27 19 1 1 20 219 2 21. 1 1. 11. 16. Stations n 11 stations 1 14 1 16 stations 29 10. 2 4 60. 7 27. 00. 7. 0 62. 267 2 299 1 1 47 1. 16. 1 ress and turn to operate ( and lock override. ) side: Orange side: Green 1.2 1-4-166

ase Mounted SY000/000 SY000: C Wiring System Compatible (Flat ribbon cable/lug-in) SSY-4GD- Stations U- (, port)pplicable tubing O.D.: ø10, ø/" holding screw 114. 1.2 2. 26 (itch) = 16 46 (.) G utton for release (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" () 26.1 1. 41.2 pplicable connector: 20 pins MIL type With strain releaf (Conforming to MIL-C-0) 2.2 110.4 Triangle mark position Note) The to dimensions of SSY-4GD- Stations D- are identical to those of SSY-4GD- Stations U-. CW type SV SZ SY SYJ 24VDC +COM - + ress and turn to operate ( and lock override. ) side: Orange side: Green (Station n) (Light/Surge ) 71.1 42.7 (ail mounting hole pitch:.) (Station 1) 7 M Terminal screw 7. 47.6 Stations n 2 stations 1. 10 1 4 6 7 9 10 stations 160. 1. 19 210. 2. 24 260. 10. 200 22 27. 20 17 11. 1 16 169 1. 201 2 2 1. 14 17. 1 1. SSY-4GD- Stations - 26 (itch) =16 lock separation button (ush type) 47 utton for release 1. G 2 ower supply terminals The indication marking is for 24 VDC. (, port) pplicable tubing O.D.: ø10, ø/" holding screw 114. 1.2 ress and turn to operate and lock override. side: Orange side: Green Triangle mark position (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" () pplicable connector: 20 pins MIL type 26.1 With strain releaf (Conforming to MIL-C-0) (.) 24VDC +COM - + (ail mounting hole pitch:.). 41.2 2.2 110.4 ower supply terminals The indication marking is for 24 VDC. Stations n Stations n 2 stations 14 17.. 11 stations 29 27. 267 4 6 7 9 10 stations 1. 19 210. 2. 24 260. 2.. 200 22 27. 20 27 1 1 1 1. 11. 20 16 219 2. 21 162. 19 10. 00 2 1. 1 14 1 16 stations 4 60. 7 7. 0 62. 1 16. 1 47 1 2. 299 1-4-167

ase Mounted SY000/000 DIN ail Manifold Exploded View Type 4F (D-sub Connector) Manifold r c w release button y u q osiotion when inserted b lock separation button t a olts e c release button Cover eplacement arts No. q w e r t-1 t-2 t- t-4 t- t-6 y u i Description Manifold block assembly SU/EXH block assembly End block assembly End block assembly Connector block assembly (for D-sub connector) Connector block assembly (for 26 pins flat cable) Connector block assembly (for 20 pins flat cable) Connector block assembly (for 10 pins flat cable) Connector block assembly (for 2 to stations (T, T1) terminal block) Connector block assembly (for 9 to stations (T1) terminal block) ound head combination screw Gasket art no. Note SY000 SY000 Manifold block assembly part number differs according to an attached lead wire assembly based on the connector spec. Select an appropriate part number from the table of manifold block assembly part number shown below. (Gasket 7 is supplied as an accessory.) (Metric size) 000-1-2 (Inch size) 000-1-16 000-2-2 000--2 000-64- 1 1N 2 2N 2 2N 2 2N 000-64- -26 000-64- -20 000-64- -10 000-64- (Metric size) 000-1-2 (Inch size) 000-1-16 000-2-2 000--2 000-64- 1 1N 2 2N 000-64- -26 2 2N 000-64- -20 2 2N 000-64- -10 000-64- 000-64- 000-64- M x 26, SY000-2-4 Matt nickel plated 000-7-4 000-7-6 VZ1000-11-1-l Metric size SY000:, port with for ø SY000:, port with for ø10 For For -1: +COM -1N: COM -2: +COM -2N: COM In common between +COM and COM. efer to page 1-4-. Note 1) The numbers -1 to 4 are for 24 VDC. For VDC, suffix -V to the end of parts number. (Example) 000-64-1- V Note 2) Two manifold block assemblies are necessary for the double, position (Dual body type). i Inch size With for ø 16" With for ø " Note) For 24 VDC Style of manifold Manifold block assembly part no. For 4(N)F (D-sub connector) 000-0-- For 4(N) G H (Flat ribbon cable) 000-0-- For 4G C Wiring System compatible T For 4 T1 000-0-7- (Terminal block) Note : port SY000 (metric size) C4: With for ø4 C6: With for ø6 (inch size) N: With One-touch fittign for ø 2" N7: With for ø 1 4", port SY000 (metric size) C4: With for ø4 C6: With for ø6 C: With for ø (inch size) N: WIth for ø 2" N7: With for ø 1 4" N9: With for ø 16" 1-4-16

ase Mounted SY000/000 How to Increase Manifold ase 1 2 4 6 7 Loosen bolt a fixing the manifold base until it begins to turn idly. (While pressing releasing buttons c, at two locations, separate the manifold base from the.) dditional bases are to be added to the. ress splitting button b of the manifold block assembly on the until button b locks, and then separate the block assemblies. Separate the connector block assembly in the same manner as 2, and remove the connector mounting screw shown in Fig. (1). Loosen the valve mounting screw on the, remove the valve, and take out the receptacle housing. (efer to Fig. (2).) Insert the common wire (red) of the manifold block assembly to be added into the pin insertion section (N mark) of the receptacle housing that was taken out in 4, mount it on the manifold block, and mount the removed valve. s shown in Fig. (), mount the additional manifold block assembly on the on the. efer to the circuit diagram, and insert the lead wire (black) as shown in Fig. (4). ress the blocks against each other until a click sound is produced, place the lead wire in the manifold block, and close the lid without pinching the lead wire. While lightly holding the blocks together so that there are no gaps between them, secure them to the by tightening the screws a. (Tightening torque: 1.4 N m) Caution Fitting ssembly 1. Depending on the connector, there is a limit to the number of solenoids that can be used. Manifold bases that can be added cannot exceed the number of usable solenoids. 2. The manifold block assembly mounting position for additional manifold bases is always on the, because wires are connected to respective connectors sequentially from the.. When bolt a for the end block is not sufficiently tightened during reassembly, air leakage may result. efore supplying air, check that there is no gap between blocks and that the manifold block is firmly fixed to the in order to ensure air supply without leakage. Type 4 manifold permits change in the and port sizes by changing the manifold block fitting assembly. fter removing the valve, remove the clip with a screwdriver, etc. For mounting a new fitting assembly, insert it and then insert a clip until it will not come out of the manifold block. Fig. (1) Connector mounting screw Fig. () Fig. (4) T D-sub connector (4F) Flat ribbon cable (4 ) Terminal block (4 T1) in Cover Note) fter inserting pins, lightly pull lead wiresto check that pins are locked. eceptacle housing Fig. (2) Hook the here and press down in the direction of the arrow until a click sound is heard. Connector Connector in Note) Insert pins after removing the connectorfrom the main unit. fter inserting pins, lightly pull lead wires to check that the pins are locked. Valve mounting screw (2 pcs.) eceptacle housing in insertion point N mark Clip Tab terminal Note) Insert tab terminals completely. SV SZ SY SYJ Fitting ssembly art No. Metric size for ø4 SY000 for ø6 for ø4 SY000 for ø6 for ø VVQ1000-0-C4 VVQ1000-0-C6 VVQ1000-1-C4 VVQ1000-1-C6 VVQ1000-1-C Inch size for ø 2 " SY000 for ø1 4 " for ø 2 " SY000 for ø1 4 " for ø 16 " Note 1) and ports cannot be changed. Note 2) Use caution that O-rings must be free from scratches and dust. Otherwise, air leakage may result. VVQ1000-0-N VVQ1000-0-N7 VVQ1000-1-N VVQ1000-1-N7 VVQ1000-1-N9 O-ring Fitting assembly 1-4-169

Type4S SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Serial Transmission (Integrated) How to Order Manifold SSY 4S 0 U C6 Symbol 0 C D E F1 G H J1 J2 K Q 1 SY000 SY000 Model Specifications Without SI unit With general type SI unit ( EX00) Mitsubishi Electric Corp.: MELSECNET/ MINI-S Data Link System OMON Corp.: SYSUS Wire System SH Corp: Satellite I/O Link System Matsushita Electric Works: MEWNET-F System NKE Corp.: Uni-wire System (16 outout points) ockwell utomation: llen radley emote I/O (IO) System NKE Corp.: Uni-wire H System SUNX Corp.: S-LINK System (16 output points) SUNX Corp.: S-LINK System ( output points) Fuji Electric Co.: T-LINK Mini System DeviceNet, Compous/D (OMON Corp.) OMON Corp.: Compous/S System (16 output points) 2 OMON Corp.: Compous/S System ( output points) U JEMNET (JCN-1) V Mitsubishi Electric Corp.: CC-LINK System For the general purpose type, a transmission unit is require on the CU side. Even though when it is not equipped with SI unit, length is long enough for future expectancy of mounting SI unit. Valve stations Symbol 02 Stations 2 stations Note Single wining spec. 16 (pplicable up to 16 solenoid valves.) 16 stations This also includes the number of blanking plate assemblies. Two stations are necessary for the double, position (Dual body type). SU/EXH block assembly mounting position Symbol Mounting position Stations U D 2 to 10 stations 2 to 10 stations (oth sides) 2 to 16 stations M Special specifications For special specifications, indicate separately on the manifold specification sheet. SI Unit art No. Symbol C D E F1 G H Specifications With general type SI unit ( EX00) Mitsubishi Electric Corp.: MELSECNET/MINI-S Data Link System OMON Corp.: SYSUS Wire System SH Corp.: Satellite I/O Link System Matsushita Electric Works: MEWNET-F System NKE Corp.: Uni-wire System (16 output points) ockwell utomation: llen radley emote I/O (IO) System NKE Corp.: Uni-wire H System Option When a longer DIN rail is desired than the specified stations, specify the station number to be required. (Max. 20 stations), port size (Metric size) Symbol ort size pplicable series C4 One-touch fitting for ø4 C6 One-touch SY000 fitting for ø6 M Mixed C4 One-touch fitting for ø4 C6 One-touch fitting for ø6 SY000 C One-touch fitting for ø M Mixed (Inch size) Symbol ort size pplicable series N One-touch fitting for ø/2" N7 One-touch SY000 fitting for ø1/4" M Mixed N One-touch fitting for ø/2" N7 One-touch fitting for ø1/4" SY000 N9 One-touch fitting for ø/16" M Mixed In the case of mixed specifications, indicate separately on the manifold specification sheet. For SSY -4S EX22-S001 EX2-SM1 EX2-ST1 EX2-SSH1 EX2-S1 EX2-SUW1 EX2-S1 EX2-SUH1 Symbol J1 J2 K Q 1 2 U V How to Order Valve Manifold ssembly Ordering example Double solenoid (24 VDC) SY24-FU Stations. 2 1 SSY-4S-0U-C6 1 set (Type 4S with serial unit stations manifold base part no.) SY140-FU sets (Single solenoid part no.) SY24-FU 1 set (Double solenoid part no.) The asterisk. denotes the. symbol. for assembly.. refix. it to the part nos. of the solenoid valve, etc. The valve arrangement is numbered as the 1st. station from D side. When ordering double solenoid valves/ position (Dual body type), please keep in mind that they require two manifold stations. Serial unit is available only for the D-side mounting type. 2 position single Double position How to Order Valves SY 1 SY 2 SY000 SY000 Type of actuation 2 2 position double position closed center 4 position exhaust center position pressure center Nil D E 4 4 Specifications: SUNX Corp.: S-LINK System (16 output points) SUNX Corp.: S-LINK System ( output points) Fuji Electric Co.: T-LINK Mini System Device Net: Compous/D (OMON Corp.) OMON Corp.: Compous/S (16 output points) OMON Corp.: Compous/S ( output points) JEMNET (JCN-1) Mitsubishi Electric Corp.: CC-LINK System Single solenoid (24 VDC) SY140-FU Manifold base ( stations) SSY-4S-0U-C6 0 FU FU ated 24 VDC Dual body type (Double, position) Non-locking push type ush-turn locking slotted type ush-turn locking lever type For SSY -4S EX2-SS EX2-SS EX2-SFU1 EX2-SDN1 EX2-SCS1 EX2-SCS2 EX2-SJN1 EX2-SMJ1 1-4-0

ase Mounted SY000/000 The serial transmission system reduces wiring work, while minimizing wiring and saving space. 16 stations max. (Specify a model with more than stations by using a manifold specification sheet.) Type S pplicable to EX00 Type S Mitsubishi Electric Corporation MELSECNET/MINI-S Data Link System Stations 2 1 The total number of stations is tabulated starting from station one on the. Maximum station: Up to 16 solenoids (16 single solenoids). Name of terminal block, LED Note LED TD UN/E Description Lights up when receiving data. Flashes when received data is normal; lights up when abnormal. Connection to T unit LC manufacturer s I/O card enables serial transmission. EX00-TM1 For models of Mitsubishi Electric Corporation EX00-TT1 For models of OMON Corporation EX00-TFU1 For models of Fuji Electric Co., Ltd. EX00-T001 For general models Up to 2 points per unit. No. of output points: 16 points LED OWE UN D SD E. Description Lights up when power supply is ON. Lights up when the data transmission with the master station is normal. Lights up when receiving data. Lights up when sending data. Lights up when data reception error occurs; goes off when the error is corrected. MELSECNET/MINI-S Data Link System Master unit: J71T2-S J71T2-S 1SJ71T2-S No. of output points: 16 points, No. of sta. occupied: 2 stations SV SZ SY SYJ SI manifold solenoid valve T unit O unit SI unit SI unit Master unit emote I/O unit emote I/O unit Item External power supply Current consumption (Internal unit) Specifications 24 VDC +10%/ % S, S, SD, SE, SF1, SG, SJ1, 0.1 SJ2, SK, S1, S2, SH, SU, SV 0. SC, SQ Cable wiring Ground either the reception side or the transmission side of the shielding wire shield. Ground either the reception side or the transmission side of the shielding wire shield. Type SC OMON Corporation SYSUS Wiring System Type SD SH Corporation Satellite I/O Link System Type SE Matsushita Electric Works, Ltd. MEWNET-F System Name of terminal block, LED LED UN T/ E Description Lights up when transmission is normal and LC is in operation mode. Flashes when transmission is normal; lights up when it is abnormal. LED OWE UN EO.SET HOLD Description Lights up when power supply is ON. Lights up when power supply is ON and the slave unit is operating normally. Lights up in cases of abnormal slave unit switch setting, abnormal communications, when the master unit LC has stopped or if the slave unit is defective. Lights up when receiving the control input from the master unit. LED OWE COMM. LM Description Lights up when power supply is ON. Flashes when sending and receiving data. Lights up when the unit is abnormal; flashes for setting error. Note SYSUS Wire System Master unit: Type C00-M201 Type C200H-M201 No. of output points: 16 points Satellite I/O Link System Master unit: ZW-1LM JW-1LM JW-2LM No. of output points: 16 points MEWNET-F System Master unit: F740 F740 No. of output points: 16 points Cable wiring Master station SI unit Type ground SI unit Type ground a) 2-wire type Wiring does not include signal ground line (SG). Master station Slave unit 01 Slave unit 02 Slave unit 7 With shield Twister pair wire Type ground Type ground Type ground Type ground a) -wire type Wiring does not include signal ground line (SG). Master station Slave unit 01 Slave unit 02 Slave unit 7 Master station SI unit SI unit Type ground Type ground With shield Twister pair wire Type ground Type ground Type ground Type ground 1-4-1

ase Mounted SY000/000 Type SF1 NKE Corporation Uni-wire System Type SG ockwell utomation, Inc. llen radley emote I/O (IO) System Type SJ1, SJ2 SUNX Corporation S-LINK System Name of terminal block, LED LED OWE SEND Description Lights up when power supply is ON. Transmission indicator: Flashes when normal; goes out or lights up when abnormal. LED OWE COM. EO Description Lights up when power supply is ON. Lights up when communication is normal. Flashes when communication is initialized. Goes out for abnormal communication. Lights up for abnormal communication. LED OWE SEND Description Lights up when power supply is ON. Transmission indicator: Flashes when normal, flashes slowly when abnormal. Note Uni-wire System Send unit: SD-0 No. of output points: 16 points emote I/O (IO) System No. of output points: 16 points S-LINK System S-LINK Controller: SL-CU1 No. of output points: 16 points (Type SJ1) No. of output points: points (Type SJ2) ower supply a) Type T branching multi-drop wiring (S-LINK System) b) Crossover wiring (Sensor Link System) Cable wiring Transmission line ower supply ower supply ower supply Master station SI unit Type ground SI unit Terminal\ register Type ground lack White Main transmission line rown lue Transmission line ressure connector SL-J1 The above is the example of using dedicated S-LINK flat ribbon cable SL-CMl00. Type SK Fuji Electric Co, Ltd. T Link Mini System Type SDQ DeviceNet Type S1, S2 OMON Corporation Compous/S System Name of terminal block, LED Note LED OWE SEND Description Lights up when power supply is ON. Lights up for abnormal transmission or power off at the processor side. T Link Mini System Master unit: FTM100 Converter: FC100-G02 epeater: FC200-C10 No. of output points: 16 points LED OWE MOD/NET DeviceNet OMON Corporation: Master station unit: No. of output points: Description Green light is ON when the circuit is powered. Goes out when SI unit is not online or the circuit is not powered. Green light is continuously ON when SI unit is on-line and in operation. ed light flashes for connection timeout (minor communication error). ed light is continuously ON for connection time-out (major communication error) or online impossibility. Compous/D System C200HW-DSM21 16 points LED OWE COMM E Description Lights up when transmission is ON; goes out when not powered. Lights up for normal communication; goes out for abnormal communication or waiting. Lights up for abnormal communication; goes out for normal communication or waiting. Compous/S System Master unit: C200HW-SM21 Master unit: COM1-SM21 No. of output points: 16 points (Type S1) No. of output points: points (Type S2) Master station Slave unit 01 Slave unit 0 Slave unit 04 Cable wiring With shield Twister pair wire Type ground Type ground Type ground Type ground Master Connector with terminal register Connect the shielding wire to the SD terminal. If the shielding wire is not connected to the SD terminal, normal transmission will be impossible even for short distances. Furthermore, do not ground the shielding wire (SD). ressure connector for distribution 1-4-2

1 2 4 6 7 O N 2 2 7 7 7 2 ase Mounted SY000/000 Type SH NKE Corporation Uni-wire H System Type SU JEMNET (JCN-1) Type SV Mitsubishi Electric Corporation CC-LINK System Name of terminal block, LED Note LED OWE SEND OWE SEND ON OFF DDESS 24V 0V D G D G 24V 0V Description Lights up when power supply is ON. (Lights on when normal; flickers when drops. Transmission indicator: flashes when normal; goes out or lights up when abnormal. Uni-wire H System Send unit: SD-H2 No. of output points: 16 points LED OWE COMM LM OWECOMM LM 24V 0V SG FG 24V 0V ON DI.SW Description Lights up when SI unit power supply is ON. Lights up for normal communication. Lights up for abnormal communication. JEM Net (JCN-1) (eference) J71J92-S (Mitsubishi Electric Corporation) 1SJ71J92-S (Mitsubishi Electric Corporation) C200HW-JM21 (OMON Corporation) NJ-JCN-1 (Fuji Electric Co., Ltd.) N1L-J1 (Fuji Electric Co., Ltd.) No. of output points: 16 points 1 0 LED W L UN SD D L E. LE. W SD LUN D TE 0 9 6 1 4 9 6 STTION NO. 0 0 24V 0V +24V 24G D D DG FG 1 4 9 6 Description Lights up when transmission power; goes out when not powered. Lights up when receiving normal data. Lights up when sending data. Lights up when receiving data. Lights up for transmission error and setting error; flashes when station or transmission speed settings are changed during operation. x 10 x 1 CC-Link System Master unit: J61T11 Master unit: 1SJ61T11 Master unit: J61QT11 Master unit: 1SJ61QT11 No. of output points: 16 points 1 4 SV SZ SY SYJ DG a) 2-wire type Cable wiring Transmission line ower supply ower supply ower supply ower supply 24V 0V 24V 0V 24V 0V 24V 0V 24V 0V DG D G 24V 0V 24V 0V DG D G 24V 0V Master station SG FG a) -wire type Master station SG FG Slave unit (SI unit) SG FG With shield Twisted pair wire Slave unit (SI unit) SG FG With shield Twisted pair wire Slave unit (SI unit) SG FG Slave unit (SI unit) SG FG Slave unit (SI unit) SG FG Slave unit (SI unit) SG FG Terminal resistor Master unit O unit O unit D D D Terminal D D D DG DG DG resistor SLD FG FG FG With shield Twisted pair wire Type ground Type ground Type ground DG 1-4-

ase Mounted SY000/000 SY000: Serial Transmission Unit/lug-in SSY-4S - Stations U- utton for release (itch) 26 = 16 41 2 1. (, port) pplicable tubing O.D.: ø10, ø/" holding screw 114. 110.4 41.2 1.2 (.) 2. (, port) pplicable tubing O.D.: ø4, ø/2" 9. () ø, ø/16". 4 64 M Terminal screw 6.2 SV SZ SY SYJ (Light/Surge ) (Station n) 71.1 42.7 SSY-4S - Stations - utton for release 26 ress and turn to operate ( and lock override. ) side: Orange side: Green (ail mounting hole pitch:.) (Station 1) (itch) = 16 42 7. lock separation button ush type 66.1 Stations n 2 stations 162. 100.4 4 6 7 9 10 stations 19 210. 2. 24 260. 2. 29. 12 1.9 200 14.2 22 164 16.7 27. 10 14.9 20 196 1.2 27 2.7 27. 22 1.9 1. 116 1.7 Note) Width of SI unit applicable to E : Matsushita Electric Works, Ltd. and G : ockwell utomation, Inc. widens to 24. mm. For further information, please consult with SMC. 2 1. (, port) pplicable tubing O.D.: ø10, ø/" holding screw (.) 2. 9. (, port) pplicable tubing O.D.: ø4, ø/2" () ø, ø/16" 114. 110.4 41.2 1.2 (ail mounting hole pitch:.) ress and turn to operate and lock override. side: Orange side: Green. 4 64 Stations n Stations n 2 stations 1. 11 14.7 11 stations. 2 262.7 4 6 7 9 10 stations 22 2. 24 260. 29 10. 2. 10 22 27. 20 27. 20 00 19. 14.9 166 19.4 1.7 1.9 1 14 1 16 stations 4 7. 27 1.9 60. 0 294 14.2 7 62. 10.4 9 7. 26 16.9 410. 400 42 1.2 2. 27 214 16. 14.9 246 1.2 Note) Width of SI unit applicable to E : Matsushita Electric Works, Ltd. and G : ockwell utomation, Inc. widens to 24. mm. For further information, please consult with SMC. 1-4-

Type4S1 SY000/000 ase Mounted Monifold Stacking Type/DIN ail Mounted Serial Transmission (Separated) How to Order Manifold SSY 4S1 D 0 U C4 Symbol 0 C D E F1 G H J1 J2 K Q 1 2 U V SY000 SY000 Model Specifications Without SI unit With general type SI unit ( EX00) Mitsubishi Electric Corp.: MELSECNET/ MINI-S Data Link System OMON Corp.: SYSUS Wire System SH Corp: Satellite I/O Link System Matsushita Electric Works: MEWNET-F System NKE Corp.: Uni-wire System (16 outout points) ockwell utomation: llen radley emote I/O (IO) System NKE Corp.: Uni-wire H System SUNX Corp.: S-LINK System (16 output points) SUNX Corp.: S-LINK System ( output points) Fuji Electric Co.: T-LINK Mini System DeviceNet, Compous/D (OMON Corp.) OMON Corp.: Compous/S System (16 output points) OMON Corp.: Compous/S System ( output points) JEMNET (JCN-1) Mitsubishi Electric Corp.: CC-LINK System For the general purpose type, a transmission unit is require on the CU side. Even though when it is not equipped with SI unit, length is long enough for future expectancy of mounting SI unit. When a shorter rail is required (same as type 4 ), suffix 0 in the optional blank at the end of part number. For SI unit specifications, efer to pages 1-4-1 to 1-4-. SI unit mounting position Symbol Mounting position U D Option When a longer is desired than the specified stations, specify the station number to be required. (Max. 20 stations), port size (Metric size) Symbol ort size C4 for ø4 C6 for ø6 M Mixed C4 for ø4 C6 for ø6 C for ø M Mixed pplicable series SY000 SY000 SU/EXH block assembly mounting position Symbol Mounting position Stations U D 2 to 10 stations 2 to 10 stations oth sides 2 to 16 stations M Special specifications For special specifications, indicate separately on the manifold specification sheet. Valve stations Symbol Stations 02 2 stations 16 16 stations (Inch size) Symbol ort size pplicable series N N7 M N for ø 2 " for ø 1 4 " Mixed for ø 2 " SY000 N7 for ø 1 4 " N9 for ø 16 " SY000 M Mixed In the case of mixed specifications, indicate separately on the manifold specification sheet. Note Single wiring spec. (pplicable up to 16 solenoid valves.) This also includes the number of blanking plate assemblies. Two stations are necessary for the double, position (Dual body type). SI Unit art No. Symbol C D E F1 G H Specifications With general type SI unit ( EX00) Mitsubishi Electric Corp.: MELSECNET/MINI-S Data Link System OMON Corp.: SYSUS Wire System SH Corp.: Satellite I/O Link System Matsushita Electric Works: MEWNET-F System NKE Corp.: Uni-wire System (16 output points) ockwell utomation: llen radley emote I/O (IO) System NKE Corp.: Uni-wire H System For SSY -4S1 EX21-S001 EX1-SM1 EX1-ST1 EX1-SSH1 EX1-S1 EX1-SUW1 EX1-S1 EX1-SUH1 Symbol J1 J2 K Q 1 2 U V For terminal LED descriptions and cable wiring, etc. for each SI unit, refer to pages 1-4-1 to 1-4-. Specifications: SUNX Corp.: S-LINK System (16 output points) SUNX Corp.: S-LINK System ( output points) Fuji Electric Co.: T-LINK Mini System Device Net: Compous/D (OMON Corp.) OMON Corp.: Compous/S (16 output points) OMON Corp.: Compous/S ( output points) JEMNET (JCN-1) Mitsubishi Electric Corp.: CC-LINK System For SSY -4S1 EX1-SS EX1-SS EX1-SFU1 EX1-SDN1 EX1-SCS1 EX1-SCS2 EX1-SJN1 EX1-SMJ1 For external pilot specifications and built-in silencer, refer to catalog on page 1-4-196. 1-4-6

ase Mounted SY000/000 How to Order Valve Manifold ssembly How to Order Valves SY 1 4 0 FU Ordering example 2 position single Double solenoid (24 VDC) SY24-FU Stations. 2 1 Single solenoid (24 VDC) SY140-FU Double, position SY 2 SY000 SY000 Type of actuation 2 2 position double position closed center 4 position exhaust center position pressure center 4 Dual body type (Double, position) FU SV SZ SY SYJ Manifold base ( stations) SSY-4S1D-0U-C6 SY-4S1D-0U-C6 1 set (Type 4S1 with serial unit station manifold base part no.) SY140-FU sets (Single solenoid part no.) SY24-FU 1 set (Double solenoid part no.) ated 24 VDC Nil Non-locking push type D ush-turn locking slotted type E ush-turn locking lever type The asterisk denotes the symbol for assembly. refix it to the part nos. of the solenoid valve, etc. The valve arrangement is numbered as the 1st. station from regardless of the mounting position of SI unit. When ordering double solenoid valves/ position (Dual body type), please keep in mind that they require two manifold stations. 1-4-7

ase Mounted SY000/000 SY000: Serial Transmission Unit/lug-in SSY-4S1 U- Stations D- (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 1. (itch) =16 26 2 Note) The to dimensions of SSY-4S1 U- Stations U- are identical to those of SSY-4S1 U- Stations D-. M Terminal screw utton for release 9. 0. (.) (, port) pplicable tubing O.D.: ø10, ø/" () holding screw 114. 64 4. 1.2 41.2 110.4 (Station n) (Light/Surge ) 66.1 (Station 1) 7. 42.7 71.1 Stations n 2 stations 4 6 7 9 10 stations 1. 210. 22 2. 260. 27 2. 29 162. 200 2. 22 20 262. 27 27. 10 1. 1 17 16. 1 169 1 1. 201 2 14 2 Note) Width of SI unit applicable to E : Matsushita Electric Works, Ltd. and G : ockwell utomation, Inc. widens to 24. mm. For further information, please consult with SMC. SSY-4S1 U- Stations - 47 (itch) =16 26 utton for release 2 1. 6.2 ress and turn to operate and lock override. side: Orange side: Green (ail mounting hole pitch:.) lock separation button (ush type) 114. (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 9. 0. 64 4. ress and turn to operate and lock override. side: Orange side: Green (.) (ail mounting hole pitch:.) (, port) pplicable tubing O.D.: ø10, ø/" () holding screw 1.2 41.2 110.4 Stations n Stations n 2 stations 4 6 7 9 10 stations 19 210. 22 2. 260. 27 2. 10. 2. 200 2. 22 20 262. 27 00. 19 1 1. 1 16. 20 219 1 2. 21 11 stations 1 14 1 16 stations. 4 7. 9 410. 2 7. 62. 7 7. 400 267 2 299 1 1 47 14 16. 1 1 11. Note) Width of SI unit applicable to E : Matsushita Electric Works, Ltd. and G : ockwell utomation, Inc. widens to 24. mm. For further information, please consult with SMC. 1-4-10

ase Mounted SY000/000 SY000: Serial Transmission Unit/lug-in SSY-4S1 D- Stations U- 2 (itch) 26 = 16 46 utton for release 1. Note) The to dimensions of SSY-4S1 D- Stations D- are identical to those of SSY-4S1 D- Stations U-. (, port) pplicable tubing O.D.: ø10, ø/" holding screw 114. 110.4 1.2 41.2 (.) (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 0. 9. () M Terminal screw. 4 64 6.2 SV SZ SY SYJ ress and turn to operate ( and lock override. ) (ail mounting hole pitch:.) side: Orange side: Green (Station n) (Station 1) (Light/Surge ) 71.1 42.7 7. SSY-4S1 D- Stations - 26 (itch) 47 = 16 66.1 lock separation button (ush type) utton for release Stations n 2 stations 162. 10 1. 4 6 7 9 10 stations 1. 210. 22 2. 260. 27 2. 29 200 2. 2 20 262. 27 27. 1 17 16. 1 169 1 1. 201 2 14 2 Note) Width of SI unit applicable to E : Matsushita Electric Works, Ltd. and G : ockwell utomation, Inc. widens to 24. mm. For further information, please consult with SMC. 1. 2 (, port) pplicable tubing O.D.: ø10, ø/" holding screw 41.2 114. 110.4 1.2 ress and turn to operate and lock override. side: Orange side: Green (.) (ail mounting hole pitch:.) (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 0. 9. (). 4 64 Stations n Stations n 2 stations 4 6 7 9 10 stations 19 210. 22 2. 260. 27 2. 10. 2. 200 2. 22 20 262. 27 00. 19 1 1. 1 16. 20 219 1 2. 21 11 stations 1 14 1 16 stations. 4 7. 9 410. 2 7. 62. 7 7. 400 267 2 299 1 1 47 14 16. 1 1 11. Note) Width of SI unit applicable to E : Matsushita Electric Works, Ltd. and G : ockwell utomation, Inc. widens to 24. mm. For further information, please consult with SMC. 1-4-11

ort Valve SY00/00 Mixed Mounting Type on ort Valve Manifold port valve can be mounted on manifold for port valve. pplication How to Order Valve Manifold ssembly ossible to be mounted on all kinds of manifolds for SY000/000. efer to How to Order Manifold for details. Ordering example Cylinder port size C6: With for ø6 port valve: Single solenoid SY0-G-C6 (1 set) + + + + + E E port valve: Double solenoid SY220-G-C6 (2 sets) port valve: Single solenoid (N.C.) SY1-G-C6 (2 sets) Manifold base ( stations) SSY-20-0 SSY-20-0 SY1-G-C6 SY0-G-C6 SY220-G-C6 1 set (Type 20, station manifold base part no.) 2 sets ( port valve, type NC part no.) 1 set ( port valve, single solenoid part no.) 2 sets ( port valve, double solenoid part no.) The asterisk denotes the symbol for assembly. refix it to the part nos. of the solenoid valve, etc. dd the valve and option part number under the manifold base part number. In the case of complex arrangement, specify them on the manifold specification sheet. 1-4-

SY000/000 ody orted/how to Order Valves Individual Wiring: For SSY -20 SY 1 L 01 SY00 SY00 Nil T Type of actuation 1 Normally closed (N.C.) 2 Normally open Nil D Solenoid type Single solenoid Double solenoid Coil specifications Standard With power saving circuit (24 VDC, VDC only) ower saving circuit is not available in the case of D, DO or W type. Thread type Nil c F G N NT T NTF port size Thread piping Symbol ort size pplicable series M M x 0. SY00 01 1 SY00 (Metric size) (Inch size) Symbol ort size pplicable series Symbol ort size pplicable series C4 for ø4 N for ø 2 " SY00 C6 for ø6 N7 for ø1 4 " SY00 C6 for ø6 N7 for ø1 4 " SY00 C for ø N9 for ø 16 " SY00 SV SZ SY SYJ Grommet G: Lead wire length 00 mm H: Lead wire length 600 mm DC 24 VDC 6 VDC V 6 VDC S VDC VDC 24,, 6,, VDC/ 100, 110, 200, 220 VC L plug connector L: With lead wire (Length 00 mm) LN: Without lead wire LO: Without connector M plug connector C ated 1 100 VC 2 200 VC 110 VC [11 VC] 4 220 VC [20 VC] DC specifications of type D and DO is only available with and 24 VDC. For type W, DC is only available. M: With lead wire (Length 00 mm) MN: Without lead wire MO: Without connector LN, MN type: with 2 sockets. For DIN terminal of SY00 series, refer to page 1-4-207. DIN terminal type Y conforming to DIN 460C is also available. For details, refer to page 1-4-201. 24, VDC/ 100, 110, 200, 220 VC DIN terminal D: With connector DO:Without connector Electrical entry 24,, 6,, VDC M connector WO: Without connector cable For connector cable of M connector, refer to page 1-4-209. Nil Non-locking push type D ush-turn locking slotted type E ush-turn locking lever type Light/Surge Electrical entry for G, H, L, M, W Nil S Z U Without light/surge With surge With light/surge With surge (Non-polar type) With light/surge (Non-polar type) For C valves there is no S option. It is already builtin to the rectifier circuit. *For and U, DC is only available. ower saving circuit is only available in the "Z" type. Electrical entry for D (SY00 only) Nil S Z Without light/surge With surge With light/surge DOZ is not available. For C valves there is no S option. It is already built-in to the rectifier circuit. Note) When placing an order for body ported solenoid valve as a single unit, mounting bolt for manifold and gasket are not attached. Order them separately, if necessary. (For details, refer to catalog on page 1-4-61.) 1-4-1

SY000/000 Flat ribbon cable: SSY -20 Light/Surge ated 24 VDC 6 VDC For DC: SY 1 LO Z For C: SY 1 SY00 SY00 Type of actuation 1 Normally closed (N.C.) 2 Normally open (N.C.) Nil D Solenoid type Single solenoid Double solenoid Individual wiring: For SSY -41/42/4 ody orted/how to Order Valves 1 LOZ SY 1 L SY00 SY00 Type of actuation 1 Normally closed (N.C.) 2 Normally open (N.C.) Nil T DC Nil D 24 VDC 6 VDC V 6 VDC S VDC VDC 1-4-14 Solenoid type Single solenoid Double solenoid ilot type Nil Internal pilot External pilot External pilot is not available for Type 41 manifold. Coil specifications Standard With power saving circuit (24 VDC, VDC only) ower saving circuit is not available in the case of D, DO or W type. C Z With light/surge With light/surge U (Non-polar type) Note) Z: ositive common specifications only. ated 1 100 VC 2 200 VC 110 VC [11 VC] 4 220 VC [20 VC] DC specifications of type D and DO is only available with and 24 VDC. For type W, DC is only available. Nil D E ated 1 100 VC 110 VC [11 VC] Non-locking push type ush-turn locking slotted type ush-turn locking lever type ase Mounted/How to Order Valves Electrical entry Grommet port size Thread piping Symbol ort size pplicable series M M x 0. SY00 01 1 SY00 (Metric size) (Inch size) Symbol ort size pplicable series Symbol ort size pplicable series C4 for ø4 N for ø 2 " SY00 C6 for ø6 N7 for ø1 4 " SY00 C6 for ø6 N7 for ø1 4 " SY00 C for ø N9 for ø 16 " SY00 Nil Non-locking push type D ush-turn locking slotted type E ush-turn locking lever type Light/Surge Electrical entry for G, H, L, M, W Nil S Z U Without light/surge With surge With light/surge With surge (Non-polar type) With light/surge (Non-polar type) For C valves there is no S option. It is already built-in to the rectifier circuit. For and U, DC is only available. ower saving circuit is only available in the "Z" type. 24,, 6,, VDC/ 100, 110, 200, 220 VC L plug connector M plug connector G: Lead wire length 00 mm L: With lead wire (Length 00 mm) M: With lead wire (Length 00 mm) H: Lead wire LN: Without lead wire MN: Without lead wire length 600 mm LO: Without connector MO: Without connector LN, MN type: with 2 sockets. For DIN terminal of SY00 series, refer to page 1-4-207. DIN terminal type Y conforming to DIN Thread type Nil c F G N NT T NTF Electrical entry for D (SY00 only) Nil S Z Without light/surge With surge With light/surge DOZ is not available. For C valves there is no S option. It is already built-in to the rectifier circuit. 24, VDC/ 100, 110, 200, 220 VC DIN terminal D: With connector DO: Without connector 24,, 6,, VDC M connector WO: Without connector cable 460C is also available. For details, refer to page 1-4-201. For connector cable of M connector, refer to page 1-4-209.

SY000/000 ase Mounted/How to Order Valves Flat ribbon cable: Connector box type: For SSY -41/42/4-41/42 For DC: 4-41/42 For C: SY 1 SY 1 SY00 SY00 Type of actuation 1 Normally closed (N.C.) 2 Normally open (N.C.) Nil D ated 24 VDC 6 VDC Solenoid type Single solenoid Double solenoid LO Z 1 LOZ ilot type Nil Internal pilot External pilot External pilot is not available for Type 41 manifold. Light/Surge With light/surge Z With light/surge U (Non-polar type) Note) Z: ositive common specifications only. Nil Non-locking push type D ush-turn locking slotted type E ush-turn locking lever type ated 1 100 VC 110 VC [11 VC] SV SZ SY SYJ lug-in: For SSY -4 Single solenoid SY 1 FU Double solenoid SY 1 C FU SY00 SY00 Type of actuation 1 Normally closed (N.C.) 2 Normally open (N.C.) Dual body type When ordering double solenoid valves (Dual body type), please keep in mind that they require two manifold stations. Nil Non-locking push type D ush-turn locking slotted type E ush-turn locking lever type ated For DC 24 VDC 6 VDC ilot type Nil Internal pilot External pilot 1-4-1

SY000/000 Construction JIS Symbol Single solenoid Normally closed (N.C.) Single solenoid JIS Symbol Double solenoid Normally closed (N.C.) Double solenoid y w u e y w u r E t q r E t q JIS Symbol Single solenoid Normally open (N.O.) Single solenoid JIS Symbol Double solenoid Normally open (N.O.) Double solenoid y w u w u e y Component arts r E t q r E t q No. Description Material Note q ody luminum die-casted (SY000: Zinc die-casted) White w dapter plate esin White e End plate esin White r iston esin t Spool valve assembly luminum, HN How to Order M ort lock ssembly eplacement arts No. Description No. y ilot valve assembly efer to How to Order ilot Valve ssembly on page 1-4-10. u M port block assembly efer to How to Order ort lock ssembly below. SY 00 2 SY00 SY00, port size Thread piping Symbol ort size pplicable series M M x 0. SY00 01 1 SY00 (Metric size) Symbol ort size pplicable series C4 for ø4 C6 for ø6 SY00 C4 for ø4 C6 C for ø6 for ø SY00 Thread type Nil F c G N NT T NTF (Inch size) Symbol ort size pplicable series N for ø 2 " N7 for ø1 4 " SY00 N for ø 2 " N7 for ø1 4 " SY00 N9 for ø 16 " Caution One-touch fitting assembly Mounting screw tightening torques SY00 (M2) : 0. N m SY00 (M) : 0.6 N m Mounting screw ort block assembly (cassette type) Only replacement of the fittings assembly is possible. Metric size for ø4 SY00 for ø6 for ø4 SY00 for ø6 for ø Inch size for ø 2 " SY00 for ø1 4 " for ø 2 " SY00 for ø1 4 " for ø 16 " VVQ1000-0-C4 VVQ1000-0-C6 VVQ1000-1-C4 VVQ1000-1-C6 VVQ1000-1-C VVQ1000-0-N VVQ1000-0-N7 VVQ1000-1-N VVQ1000-1-N7 VVQ1000-1-N9 1-4-16

SY000/000 Specifications Dimensions, specifications, solenoid specifications, response time and effective area are the same as port valve. Weight SY00 Type of actuation Single Double Single Double Single Double Single Double Grommet 1 6 6 74 4 72 47 6 Weight (g) L, M plug connector 74 9 79 7 77 0 70 SY00 Valve model SY - -01 Valve model SY - -M C4 SY - - N C6 SY - - N7 SY - C4 SY - -N C6 SY - -N7 C SY - -N9 SY - Type of actuation Single Double Single Double Single Double Single Double Single Double Grommet 69 7 2 100 79 97 7 9 7 Weight (g) L, M plug connector DIN terminal 72 9 9 1 2 10 102 144 77 9 9 140 4 10 10 147 79 7 0 SV SZ SY SYJ 1-4-

Type4S2 Made to Order Specifications: 000/000 Serial Transmission Type With SMC s IN1 Serial Transmission Manifold Equipped with SMC s IN1 How to Order Manifold Type 4S2 (Serial type with IN1) SSY 4S2 U 06 D C4 SY000 SY000 Symbol Stations 02 2 stations 16 SI unit mounting position Symbol Mounting position U D 16 stations Valve stations Note Single wining spec. (pplicable up to 16 solenoid valves.) This also includes the number of blanking plate assemblies. Two stations are necessary for the double, position (Dual body type). SU/EXH block assembly mounting position Symbol Mounting position Stations U D 2 to 10 stations 2 to 10 stations oth sides 2 to 16 stations M Special specifications For special specifications, indicate separately on the manifold specification sheet., port size (Metric size) Symbol ort size pplicable series for ø4 for ø6 SY000 Mixed C4 C6 M C4 C6 C M for ø4 for ø6 for ø Mixed SY000 (Inch size) Symbol ort size pplicable series N N7 for ø 2 " for ø1 4 " SY000 M N Mixed for ø 2 " N7 for ø1 4 " N9 for ø 16 " SY000 M Mixed In the case of mixed specifications, indicate separately on the manifold specification sheet. Option When a longer is desired than the specified stations, specify the station number to be required. (20 stations at maximum) How to Order pplicable SI Unit IN1 How to Order Valves 2 position single Double, position M1 pplicable makers M1 For Mitsubishi Electric Corporation T1 For OMON Corporation FU1 For Fuji Electric Co., Ltd. SH1 For SH Corporation TY1 TY2 For Toyoda Machine Works, Ltd. 1 For Matsushita Electric Works Ltd. HT1 For Hitachi, Ltd. 1 For ockwell utomation, Inc. TS1 For TOSHI Corporation SY 1 4 0 FU SY 2 SY000 SY000 Type of actuation 2 2 position double position closed center 4 position exhaust center position pressure center 4 Dual body type (Double, position) FU ated 24 VDC Nil D E Non-locking push type ush-turn locking slotted type ush-turn locking lever type 1-4-1 For external pilot specifications and built-in silencer, refer to page 1-4-196.

SY000/000 SY000: Serial Transmission Unit/lug-in SSY-4S2D- Stations U- utton for release 2 (, port) pplicable tubing O.D.: ø10, ø/" (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 114. 110.4 41.2 1.2. holding screw ress and turn to operate and lock override. side: Orange side: Green 26 (.) (itch) = 16 46 SMC IN1-M1 7 4 (ail mounting hole pitch:.) (Station n) (Station 1) (Light/Surge ) OWEUN SD D EO x 10 x 1 OUTUT 0 1 2 4 6 7 9 CDEF STTION NO. () 1. 1.7 4 Note) G1/2 (Signal, power supply output port) The to dimensions of SSY-4S2D- Stations D-, SSY-4S2U- Stations D-, SSY-4S2U- Stations U- are identical to those of SSY-4S2D- Stations U-. 29.. 1.2 72.9 42.7 7. lock separation button (ush type) G1/2 (Signal, power supply output port) (itch) utton for release 26 = 16 47 SSY-4S2U- Stations - 2 9 21 27. 11. 1. Stations n 2 stations 4 6 7 9 10 stations 210. 22 24 260. 27 29 10. 2. 200 2. 27. 20 262. 27. 00. 2 10 1. 1 17 16. 1 169 1 1. 201 2 14 2 Note) The to dimensions of SSY-4S2U- Stations - are identical to those of SSY-4S2D- Stations -. (, port) pplicable tubing O.D.: ø10, ø/" (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" (.) 7 4 () 114. 110.4 41.2 2.. holding screw ress and turn to operate and lock override. side: Orange side: Green SMC IN1-M1 (ail mounting hole pitch:.) OWEUN SD D EO x 10 x 1 OUTUT 0 1 2 4 6 7 9 CDEF STTION NO. 1.7 4 21 Stations n 2 stations 4 6 7 9 stations 2. 24 260. 27 29 10. 2 4 22 27. 20 262. 27. 00. 7. 19 1 1. 1 16. 20 219 1 2. Stations n 10 stations 11 1 14 1 16 stations 60. 7. 410. 42 4. 460. 0 62. 7 400 4. 42 40 21 267 14 2 299 16. 1 1 1 1 47. 1-4-190

Type4S Made to Order Specifications: 000/000 Serial Transmission Type With OMON Corp s G71-OD16 Serial Transmission Manifold Equipped with OMON Corp s Transmission Unit G71-OD16 How to Order Manifold Type 4S (Serial type with transmission unit) SSY 4S U 06 D SY000 SY000 Specifications Symbol Specifications Nil With transmission unit 0 Note) Without transmission unit Note) Even though when it is not equipped with transmission unit, length is long enough for future expectancy of mounting transmission unit. When a shorter rail is required (same as type 4 ), suffix 0 in the optional blank at the end of part number. Transmission unit mounting position Symbol Mounting position U D Symbol Stations 02 2 stations 16 16 stations Valve stations Note Single wiring spec. (pplicable up to 16 solenoid valves.) This also includes the number of blanking plate assemblies. Two stations are necessary for the double, position (Dual body type). SU/EXH block assembly mounting position Symbol Mounting position Stations U D 2 to 10 stations 2 to 10 stations (oth sides) 2 to 16 stations M Special specifications C4 For special specifications, indicate separately on the manifold specification sheet., port size (Metric size) (Inch size) Symbol ort size pplicable series Symbol ort size pplicable series C4 C6 M C4 C6 C M for ø4 for ø6 Mixed SY000 for ø4 for ø6 SY000 for ø Mixed N N7 M N N7 N9 M for ø 2 " for ø1 4 " SY000 Mixed for ø 2 " for ø1 4 " SY000 for ø 16 " Mixed In the case of mixed specifications, indicate separately on the manifold specification sheet. Option When a longer is desired than the specified stations, specify the station number to be required. (20 stations at maximum) For external pilot specifications and built-in silencer, refer to page 1-4-196. How to Order Valves 2 position single Double, position Internal Wiring of Manifold Serial Type 4S (Example of arrangement) Caution SY 1 4 0 FU SY 2 SY000 SY000 Type of actuation 2 2 position double position closed center 4 position exhaust center position pressure center FU The wiring specifications for SSY -4S0 are different from those for SSY -4G. 4 Dual body type (Double, position) ated 24 VDC Single solenoid Single solenoid Single solenoid Double solenoid Dual body type Double solenoid Dual body type ower supply terminal Nil D E Station 1 Station 2 Station Station 4 Station Station 6 Station 7 Station Non-locking push type ush-turn locking slotted type ush-turn locking lever type Station 9 Station 10 Station 11 Station Station 1 Station 14 Station 1 Station 16 Minus port lus port (common) Triangle mark For specifications on OMON Corp s transmitter terminals, refer to the instruction manual or the catalog of transmitter terminals, etc. Max. 16 solenoids are applicable. lease consult with SMC for more solenoids. 1-4-191 SV SZ SY SYJ

Made to Order Specifications SY000/000 SY000: Serial Transmission Unit/lug-in SSY-4SD- Stations U- utton for release 2 (, port) pplicable tubing O.D.: ø10, ø/" 26 (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 114. 110.4 41.2 1.2 (.) (itch) = 16 46 60 G71-OD16 OMON UN OUTUT E T/ OWE S4 () 1.. 42. 4 Note) The to dimensions of SSY-4SD- Stations D-, SSY-4SU- Stations D-, SSY-4SU- Stations U- are identical to those of SSY-4SD- Stations U-. SV SZ SY SYJ + - holding screw (Station n) (Light/Surge ) 72.9 42.7 24VDC +COM - + Transmission terminal G71-OD16 ress and turn to operate ower supply terminal ( and lock override. ) side: Orange side: Green (ail mounting hole pitch:.) (Station 1) 7.1 CH OUT M Terminal screw 7. 6.1 ail stopper TXE1-SMC Stations n 2 stations 4 6 7 9 10 stations 210. 22 2. 260. 27 2. 29 2. 200 2. 22 20 262. 27 27.. 2 10 16. 1 1 17 1 1. 169 16 1 14 201. 2 2 1 SSY-4SD- Stations - utton for release lock separation button (ush type) 26 (itch) = 16 47 Note) The to dimensions of SSY- 4SU- Stations - are identical to those of SSY-4SD- Stations -. 2 1. (, port) pplicable tubing O.D.: ø10, ø/" (, port) pplicable tubing O.D.: ø4, ø/2" ø, ø/16" 60 () (.) 4 114. 110.4 41.2 2. holding screw ress and turn to operate and lock override. side: Orange side: Green 24VDC +COM - + G71-OD16 OMON (ail mounting hole pitch:.) CH OUT UN OUTUT E T/ OWE + - S4 Transmission terminal G71-OD16 ower supply terminal. 42. ail stopper TXE1-SMC Stations n 2 stations 4 6 7 9 stations 22 2. 260. 27 2. 10. 2. 2. 22 20 262. 27 00. 2 14 19 1 16. 1 1 1 20. 219 16 2 14 Stations n 10 stations 11 1 14 1 16 stations 4 7. 9 410. 4. 44 7. 62. 7 7. 400 42 47. 21. 267 2 1 299 1. 1 11. 1 16 47 1-4-19

4 Type Made to Order Specifications: SY000/000 External ilot/uilt-in Silencer External pilot manifold bases for low-pressure/vacuum use are added to split style/ manifolds. The built-in silencer has materialized a clear-cut appearance. Individual Wiring/Connector ox Type How to Order Manifold Type 4 SSY SY000 SY000 Valve stations SU/EXH block assembly Symbol Stations mounting position 02 2 stations Symbol Mounting position Stations U 20 20 stations D 2 to 10 stations The number of blanking plate oth sides 2 to 20 stations assembly is M Special specifications included. For special specifications, indicate separately on the manifold specification sheet. 4 0 U C6 SU/EXH block assembly specifications Symbol Specifications External pilot S Internal pilot/uilt-in silencer S External pilot/uilt-in silencer (Metric size) Symbol ort size pplicable series for ø4 for ø6 Mixed SY000 C4 C6 M C4 C6 C M for ø4 for ø6 SY000 for ø Mixed In the case of mixed specifications, indicate separately on the manifold specification sheet. Option When a longer is desired than the specified stations, specify the station number to be required. (Max. 20 stations), port size (Inch size) Symbol ort size pplicable series N for ø 2 " N7 for ø1 4 " SY000 M Mixed N for ø 2 " N7 for ø1 4 " N9 for ø 16 " SY000 M Mixed How to Order Valve Manifold ssembly Ordering example Single solenoid (external pilot specifications) SY140-G ( sets) + + + + + 2 1 Stations SSY-4-0DS-C6 SY140-G The asterisk denotes the symbol for assembly. refix it to the part nos. of the solenoid valve, etc. uilt-in silencer Manifold base ( stations) SSY-4-0DS-C6 1 set (External pilot with built-in silencer part no.) sets (Single solenoid part no.) The valve arrangement is numbered as the 1st. station from regardless of the mounting position of SU/EXH block assembly. In ordering, specify the part nos. in the order from the 1st. station on. esides, when the arrangement will be complicated, fill out the manifold specification sheet to instruct us. For manifolds with SU/EXH block assembly at each end of the manifold, external pilot ports and silencers will be also located at each end of the manifold. The SU/EXH block assembly (/000-1-1), for special usage, as shown on page 1-4-10, can also be mounted. lease specify the mounting position, by correctly filling in the blank space on the manifold specification sheet. 1-4-194

Made to Order Specifications SY000/000 SY 2 40 L How to Order Valves SY000 SY000 Type of actuation 1 2 position single 2 2 position double position closed center 4 position exhaust center position pressure center Nil T Nil ilot type Internal pilot External pilot Coil specifications Standard With power saving circuit (24 VDC, VDC only) ower saving circuit is not available in the case of D, DO or W type. ated DC 24 VDC 6 VDC V 6 VDC S VDC VDC C ( 0 60 Hz) 1 100 VC 2 200 VC 110 VC [11 VC] 4 220 VC [20 VC] DC specifications of type D and DO is only available with and 24 VDC. For type W, DC is only available. D and DO only available for SY000. Light/Surge Electrical entry for G, H, L, M, W Nil Without light/surge S With surge Z With light/surge With surge (Non-polar type) U With light/surge (Non-polar type) For C valves there is no S option. It is already built-in to the rectifier circuit. For and U, DC is only available. ower saving circuit is only available in the "Z" type. Electrical entry for D (SY000 only) Nil Without light/surge S With surge (Non-polar type) Z With light/surge (Non-polar type) DOZ is not available. For C valves there is no S option. It is already built-in to the rectifier circuit. Nil Non-locking push type D ush-turn locking slotted type E ush-turn locking lever type SV SZ SY SYJ Electrical entry Grommet G: Lead wire length 00 mm H: Lead wire length 600 mm 24,, 6,, VDC/100, 110, 200, 220 VC L plug connector L: With lead wire (Length 00 mm) LN: Without lead wire LO: Without connector M plug connector M: With lead wire (Length 00 mm) MN: Without lead wire MO: Without connector 24, VDC/ 100, 110, 200, 220 VC DIN terminal (SY000 only) D: With connector DO: Without connector 24,, 6,, VDC M connector WO: Without connector cable LN, MN type: with 2 sockets. D and DO only available for SY000. DIN terminal type Y conforming to DIN460C standard is also available. For details, refer to page 1-4-201. Setting -LOU is available only for connector box type. For connector cable of M connector, refer to pages 1-4-209 to 210. 1-4-19

SY000/000 lug-in How to Order Manifold Type 4 SSY 4 F U 0 U SY000 SY000 Common specifications Connector Nil ositive common mounting position N Negative common Symbol Mounting position No symbol is used for T, T1, S types. U D Connector type Symbol Mounting position F D-sub connector Flat ribbon cable 26 pins G Flat ribbon cable 20 pins H Flat ribbon cable 10 pins T Terminal block 9 pins T1 Terminal block 1 pins S Serial transmission type For details, refer to page 1-4-140. Valve stations Symbol Stations Note 02 2 stations Single wining specificatios 20 20 stations This also includes the number of blanking plate assemblies. Depending on the connector, the number of stations is limited. efer to page 1-4-14. Two stations are necessary for the double, position (Dual body type). SU/EXH block assembly mounting position Symbol Mounting position Stations U 2 to 10 stations D (oth sides) 2 to 20 stations M Special specifications For special specifications, indicate separately on the manifold specification sheet. SU/EXH block assembly specifications Symbol Specifications External pilot S Internal pilot/uilt-in silencer S External pilot/uilt-in silencer, port size (Metric size) (Inch size) Symbol ort size pplicable series Symbol ort size pplicable series C4 for ø4 N for ø 2 " C6 for ø6 SY000 N7 for ø1 4 " SY000 M Mixed M Mixed C4 for ø4 N for ø 2 " C6 for ø6 N7 for ø1 4 " SY000 SY000 C for ø N9 for ø 16 " M Mixed M Mixed In the case of mixed specifications, indicate separately on the manifold specification sheet. Voltage Nil 24 VDC Option V VDC When a longer is desired than No symbol is used for T, T1, S types. the specified stations, specify the station number to be required. (20 stations at maximum) 1-4-196 How to Order Valve Manifold ssembly Ordering example Single solenoid (external pilot specifications) SY140-FU ( sets) Double solenoid (external pilot specifications) SY24-FU (1 set) Stations 2 1 SSY-4FU-0DS-C6 1 set (External pilot with built-in silencer part no.) SY140-FU sets (Single solenoid part no.) SY24-FU 1 set (Double solenoid part no.) The asterisk denotes the symbol for assembly. refix it to the part nos. of the solenoid valve, etc. The valve arrangement is numbered as the 1st. station from regardless of the mounting position of SU/EXH block assembly. In ordering, specify the part nos. in the order from the 1st. station on. esides, when the arrangement will be complicated, fill out the manifold specification sheet to instruct us. For manifolds with SU/EXH block at each end of the manifold, external pilot ports and silencers will be also located at each end of the manifold. The SU/EXH block assembly (/000-1-1), for special usage, as shown on page 1-4-10, can also be mounted. lease specify the mounting position, by correctly filling in the blank space on the manifold specification sheet. Two stations of the manifold base are necessary for the double, position (Dual body type). Use caution when specifying the number of stations required for the manifold base. SY000 SY000 How to Order Valves SY 1 4 FU Type of actuation 1 2 position single 2 2 position double position closed center 4 position exhaust center position pressure center ody Option 0 Standard (Single only) Dual body type (Double, position) Nil ated 24 VDC 6 VDC V 6 VDC S VDC VDC Mark: 4T and T1 only S type is available for 24 VDC only. ilot type Internal pilot External pilot Nil D E uilt-in silencer Manifold base ( stations) SSY-4FU-0DS-C6 Non-locking push type ush-turn locking slotted type ush-turn locking lever type