Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

Similar documents
Powerware Battery Charger Module. User s Guide. Models ASY-0652 and ASY

Powerware Vdc Extended Battery Cabinet User s Guide.

02/15/01. Powerware User s Guide VA.

POWERWARE User s Guide VA.

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

Electrical Installation

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

Foreword

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

02/15/ RM. Powerware. User s Guide VA.

Cruising Charger Series OWNER S MANUAL

MAPNET II Transceiver Installation Instructions

Extended Battery Cabinet for Nfinity

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

Safety and General Information

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

3000VA 120/208/230VAC

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

Sentinel Field Satellite Controller

Innovative Circuit Technology Ltd.

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

User Manual. Solar Charge Controller 3KW

Operating Instructions

Price Computing Scale D Series Operation Manual

Expansion Signal (XSIG) Card Installation Instructions

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

USER MANUAL English / Español

Installation and user manual. Tower models 5P 750 5P P P 850G 5P 1550G

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Online Battery Backup

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

A419ABG-3C Electronic Temperature Control

Liebert GXT3 230V, ,000VA

WF-5110R True Sine Wave Inverter

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Twelve Unit Rapid Charger

OWNER'S OPERATING MANUAL

LED/Switch Modules Installation Instructions

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

Installation and Operating Manual

SPOTLIGHT 30 MILLION CANDLEPOWER

Eclipse Plus VA UPS and Surge Suppressor User s Manual

WF-5110R True Sine Wave Inverter

Lamp kit. Installation manual SIM 7 series R

Liebert GXT4. User Manual 700VA ~ 3000VA (230V)

AIS and 40 kva 400 V. Site Preparation and Installation Manual

Industrial On-Line UPS V, 700 VA VA. S4KC Series. Instruction Manual

Installing the Switch Chassis

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

XPRT 6kVA & 10kVA Online UPS

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Aurora Single Phase Emergency Lighting Inverters

Polaris 1000 User s Manual

5P 1500 RT 5P 2200 RT 5P P 3000 RT 5P Installation and user manual ENGLISH. Copyright 2012 EATON All rights reserved.

Innovative Circuit Technology Ltd.

WF-5100 Series True Sine Wave Inverters

9120 EBCU Battery Charger MODELS: 9120EBCU96V 9120EBCU240V

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

BroadBand PowerShield. 20 AHr Battery. User Manual

RK Standby Battery Operator s Manual

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

UNISTAR SB-NET V 50/60Hz 800VA to 3kVA USER MANUAL

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)

SAVE THESE INSTRUCTIONS

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

Patient Lift Scale Indicator Owner s Manual

SurePower Battery Pack Guide

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

RK Standby Battery Operator s Manual

Digital/Analog Amplifiers Installation Instructions

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

SRK12KX Battery-powered Crimping Tool

Home Solar 400 (HS 400) Home Solar 800 (HS 800) Home Backup 400 (HB 400) Home Backup 800 (HB 800) Owner s Manual

Installation Instructions

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

5P 650 AU 5P 650i R 5P 850 AU 5P 850i R 5P 1150 AU 5P 1150i R 5P 1550 AU 5P 1550i R. User's guide

Delta UPS - Ultron Family. HPH Series, Three Phase 20/30/40/60 kva 208V. User Manual. The power behind competitiveness

MODEL PS-4 DIGITAL PORTION SCALE

Installation Manual. Rev

Galaxy VM. Modular Battery Cabinets Installation GVMMODBCW, GVMMODBCN 09/

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Innovative Circuit Technology Ltd.

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Allen-Bradley 1609-D600N

c-go 24V/6A 24V/8A 24V/12A

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Switching DC Power Supply

General Description. Product Specification. Document Digital Temperature Interlock

Galaxy Receiving and Unpacking 09/

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

Eaton 9PXM. 4-20kVA Split-Phase Rack-Tower UPS Guide Specification

SENS DC PowerCab 120 Installation, Operation, & Maintenance Manual

Galaxy VX. 480 V UPS System Technical Specifications 07/

BatteryChargers. Quick Start Guide AA RECHARGER POWERCHARGER

Updated: October 2012

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

Transcription:

Eaton 9170 + Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

Class A EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. W A R N I N G WARNING This is a product for restricted sales distribution to informed partners. Installation restrictions or additional measures may be needed to prevent electromagnetic disturbances. Eaton is a registered trademark of Eaton or its subsidiaries and affiliates. All other trademarks are property of their respective companies. Copyright 2002-2015 Eaton, Raleigh, NC, USA. All rights reserved. No part of this document may be reproduced in any way without the express written approval of Eaton.

Special Symbols The following are examples of symbols used on the product to alert you to important information: RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol. CAUTION: REFER TO OPERATOR'S MANUAL - Refer to your operator's manual for additional information, such as important operating and maintenance instructions. This symbol indicates that you should not discard waste electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center.

Table of Contents 1 INTRODUCTION........................................................................ 7 Physical Features................................................................ 7 2 INSTALLATION......................................................................... 11 Cabinet Preparation.............................................................. 11 DC Cabling Between Cabinets..................................................... 12 Setting DIP Switches............................................................. 12 Output Current Limit......................................................... 12 Periodic Float Charge........................................................ 13 Reserved Switch............................................................ 13 Battery Charger Module Installation................................................. 13 3 OPERATION............................................................................ 15 UPS Cabinet Operation........................................................... 15 External Battery Cabinet Operation.................................................. 15 Output Foldback................................................................ 15 4 SPECIFICATIONS....................................................................... 17 5 TROUBLESHOOTING.................................................................... 23 Alarm Messages................................................................ 23 Audible Alarms and UPS Conditions................................................. 23 Battery Charger Module Replacement............................................... 23 Service and Support.............................................................. 24 Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality 5

Table of Contents 6 Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality

Chapter 1 Introduction The optional Eaton 9170+ battery charger module is designed to provide additional current for faster recharging of uninterruptible power system (UPS) battery modules in systems with many batteries. NOTE To realize maximum module functionality, install battery charger modules in the UPS cabinet. For systems with especially long runtime requirements, DIP switches on the rear panel of the battery charger module make it possible to install the module in a specially designed external battery cabinet (ASY-0739). The battery charger module is capable of providing up to 20 amperes of current for optimum charging, based upon the condition and number of batteries in the system. Examples of improved system recharge times are shown in Table 1. Note that larger systems require at least one (or more) battery charger modules to be able to recharge the larger number of battery modules. Table 1. Recharge Times Using Battery Charger Modules Designed Runtime (Minutes) Number of Battery Charger Modules Battery Modules 6 kva Capacity 12 kva Capacity 18 kva Capacity Recharge Time (Hours) Battery Modules Recharge Time (Hours) Battery Modules Recharge Time (Hours) 0 20 20 20 58 16 32 48 1 3 4 6 120 1 28 5 56 8 82 11 240 360 480 1 9 17 N/A 54 110 160 2 6 9 13 1 14 N/A N/A 78 160 234 2 7 14 19 1 18 N/A N/A 2 102 10 200 18 308 26 3 7 13 18 Physical Features The battery charger module is similar in appearance to a power module. The two primary differences are the front label color (light-purple for the ASY-0652 and orange for the ASY-0675) and the current-limit DIP switch on the rear panel of the module as shown in Figure 1. See Setting DIP Switches on page 12 for more information on DIP switch functions. The module may be installed in either the UPS cabinet (6-, 9-, and 12-slot sizes) or a special 12-slot external battery cabinet. Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality 7

Introduction Current Limit 1 2 5A Off Off* On 10A On Off DIP Switch Detail Off 1 2 3 4 15A 20A Off On On On * Factory default setting Figure 1. Battery Charger Module (Rear View) The external battery cabinet may have input power hardwired through rigid or flexible conduit, as shown in Figure 2, or input power may be supplied through a plug-terminated line cord (requires the purchase of a line cord kit). Besides input power, the external battery cabinet has a cable or conduit connection to the UPS cabinet. It may also have a cable or conduit to additional external battery cabinets. 8 Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality

Introduction To UPS or Previous External Battery Cabinet DC Emergency Disconnect Switch Button AC Line In To Next External Battery Cabinet Figure 2. External Battery Cabinet for Charger Modules Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality 9

Introduction 10 Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality

Chapter 2 Installation Eaton 9170+ battery charger modules can be plugged into any UPS cabinet slot above the battery modules, but below the power modules. Battery charger modules may be installed in only one type of external battery cabinet, the ASY-0739 12-slot external battery cabinet (top three slots only). Plugging them into the other slots, or other types of external battery cabinet, can result in damage. NOTE Do not block the cabinet s ventilation holes on the sides or the back. Cabinet Preparation Follow the procedures in the Eaton 9170+ UPS (3-18 kva) User s Guide for: l l Equipment clearances Installing the UPS cabinet and optional external battery cabinets If additional external battery cabinets are to be used for battery charger modules, install input power wiring to each additional cabinet (see Figure 3). Table 2 shows required wire sizes based upon the number of battery charger modules. For each 12-slot external battery cabinet, stabilizer brackets must be installed. If required, also install a floor anchor kit as described in the Eaton 9170+ UPS (3-18 kva) User s Guide. NOTE The ASY-0739 12-slot external battery cabinet must be wired for input power from the utility AC power supply. (a) Split-Phase Power Modules (3-wire plus ground input) (2 PEN) 100/200, 110/220, 120/208, 120/240, 127/220 Vac (b) Universal Power Modules (2-wire plus ground input) 200, 208, 220, 230, and 240 Vac L2 L1 3 2 1 L1 3 2 1 N L2/N GND GND Figure 3. Input Power Wiring to ASY-0739 External Battery Cabinet Table 2. Required Input Wiring for ASY-0739 External Battery Cabinet Number of Charger Modules Input Circuit Breaker Rating 75 C Copper Wire Size Conductor Screw Torque 1 15A 14/12 AWG 2.3 Nm (20 lb in) 2 30A 10 AWG 2.3 Nm (20 lb in) 3 45A 8 AWG 2.8 Nm (25 lb in) Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality 11

Installation DC Cabling Between Cabinets Refer to Battery Cabinet Installation in the Eaton 9170+ UPS (3-18 kva) User s Guide for the procedure to connect the cable assembly between the external battery cabinet and the UPS cabinet, or to additional external battery cabinets. NOTE The cabinet-to-cabinet DC wiring starts in the second-from-top section of the UPS and daisy-chains to the external battery cabinet entrance panels located adjacent to the DC Emergency Disconnect Switches. Note that ASY-0739 has an entrance panel on its top module which only accommodates AC input for chargers, not DC connections. See Figure 2 on page 9 for the proper location of cabinet-to-cabinet wiring. Setting DIP Switches The DIP switches on the rear panel of the battery charger module are functional only when the module is installed in an external battery cabinet. The DIP switches control two functions: the output current limit and a periodic float charging to equalize all battery capacities. NOTE When the module is placed in the UPS cabinet, do not set the DIP switches. Set the DIP switches ONLY if the battery charger module is placed in the ASY-0739 12-slot external battery cabinet. The ASY-0739 is the only battery cabinet that can accommodate battery charger modules (top three slots only). Output Current Limit The battery charger module is capable of producing up to 5A, 10A, 15A, or 20A when installed in an external battery cabinet. Discharged batteries must be recharged at an optimum rate, neither too quickly nor too slowly. For optimum charging of batteries, you must set DIP switches 1 and 2. Follow the guidelines in Table 3 to determine the proper output current setting and set DIP switches 1 and 2 accordingly (see Figure 4). Table 3. Output Current Limit Settings Output Current Limit Minimum Requirement DIP Switch 1 DIP Switch 2 5A 2 battery strings (7.2 Ah) Off Off* 10A 4 battery strings (14.4 Ah) On Off 15A 6 battery strings (21.6 Ah) Off On 20A 8 battery strings (28.8 Ah) On On NOTE A battery string is made up of two battery modules. * Factory-default setting On Off 1 2 3 4 Figure 4. DIP Switches 12 Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality

Installation Periodic Float Charge To enable automatic float (or equalize) charging of the battery modules every 30 days, set DIP switch 3 to ON. NOTE When more than one battery charger module is installed in ASY-0739, only one of them should have Periodic Float Charge set to ON. Reserved Switch The function of DIP switch 4 is reserved; it should remain in the OFF position. Battery Charger Module Installation To install the battery charger modules into the UPS or external battery cabinet: NOTE Place battery charger modules above the battery modules in the UPS cabinet, or in any of the top three slots of the ASY-0739 12-slot external battery cabinet. CAUTION A maximum, total combination of seven (7) power modules and battery charger modules are allowed in the UPS cabinet. If additional battery charger modules are needed for the system, you must install them in ASY-0739 cabinets. 1. Remove the front cover(s) of the cabinet. The covers have spring latches on the left and right sides that hold them in place. 2. Insert the battery charger modules into the cabinet. To insert a battery charger module: Lower the front slightly and lift the rear edge over the safety stop on the center support rail. Keep the module handle extended until the module is fully inserted. Raise the battery charger module handle to secure the module into the cabinet. Be sure the handle latch snaps into place. Tighten the thumbscrew on the handle. 3. Reinstall the front cover(s). 4. Turn on the UPS according to the Eaton 9170+ UPS (3-18 kva) User s Guide. Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality 13

Installation 14 Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality

Chapter 3 Operation The Eaton 9170+ battery charger module operates in two automatic modes: l l As a charger module within the UPS cabinet under control of the UPS power modules As an independent charger module located in an external battery cabinet containing battery modules for the UPS system UPS Cabinet Operation When the battery charger module is installed in the UPS cabinet, it communicates through a controller area network (CAN) bus with the power modules. The power modules monitor and control the battery charger. Alarm conditions detected by the battery charger module are logged and announced by the UPS system (refer to the Eaton 9170+ UPS (3-18 kva) User s Guide). Normal output voltage is 133 Vdc. External Battery Cabinet Operation When the battery charger module is installed in an external battery cabinet, it has no communication path with the UPS power modules. Therefore, it controls its own operation, independent of any system information within the power modules. The module output current limit is set by the rear panel DIP switches. An audible alarm signals module status and alarm conditions (see Troubleshooting on page 23). Normal output voltage is 133 Vdc. Output Foldback If the battery charger module senses a charged-battery condition, it folds back its output voltage to prevent overcharging system batteries. Output current is controlled by power modules on the UPS CAN bus or by the rear panel DIP switches. Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality 15

Operation 16 Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality

Chapter 4 Specifications This chapter provides specifications for battery charger modules. Table 4. Model Specifications for Universal Power Modules (ASY-0528 and ASY-0674) Optional Chargers UPS kva/watts Input Current for 200/208/220/230/240V Three-Slot Cabinet Output Current for 200/208/220/230/240V Recommended Input Service Heat Dissipation NA 3/2100 14/13.5/13/12.5/12A 15/14.5/14/13/12.5A 25A 285W (0.98 kbtu/hr) Six-Slot Cabinet CAUTION: Do NOT install more than three power and/or battery charger modules in a 6-slot cabinet. Optional Chargers UPS kva/watts Input Current for 200/208/220/230/240V Output Current for 200/208/220/230/240V Recommended Input Service Heat Dissipation 0 3/2100 14/13.5/13/12.5/12A 15/14.5/14/13/12.5A 25A 285W (0.98 kbtu/hr) 1 3/2100 30/29.5/29/28.5/28A 15/14.5/14/13/12.5A 40A 570W (1.95 kbtu/hr) 2 3/2100 46/45.5/45/44.5/44A 15/14.5/14/13/12.5A 60A 860W (2.93 kbtu/hr) 0 6/4200 28/27/26/25/24A 30/29/28/26/25A 40A 570W (1.95 kbtu/hr) 1 6/4200 44/43/42/41/40A 30/29/28/26/25A 60A 860W (2.93 kbtu/hr) 0 9/6300 42/40.5/39/37.5/36A 45/43.5/42/39/37.5A 60A 860W (2.93 kbtu/hr) Nine- and Twelve-Slot Cabinet CAUTION: Do NOT install more than seven power and/or battery charger modules in a 9- or 12-slot cabinet. Optional Chargers UPS kva/watts Input Current for 200/208/220/230/240V Output Current for 200/208/220/230/240V Recommended Input Service Heat Dissipation 0 3/2100 14/13.5/13/12.5/12A 15/14.5/14/13/12.5A 25A 285W (0.98 kbtu/hr) 1 3/2100 30/29.5/29/28.5/28A 15/14.5/14/13/12.5A 40A 570W (1.95 kbtu/hr) 2 3/2100 46/45.5/45/44.5/44A 15/14.5/14/13/12.5A 60A 860W (2.93 kbtu/hr) 3 3/2100 62/61.5/61/60.5/60A 15/14.5/14/13/12.5A 80A 1145W (3.90 kbtu/hr) 4 3/2100 78/77.5/77/76.5/76A 15/14.5/14/13/12.5A 100A 1430W 5 3/2100 94/93.5/93/92.5/92A 15/14.5/14/13/12.5A 125A 1720W 0 6/4200 28/27/26/25/24A 30/29/28/26/25A 40A 570W (1.95 kbtu/hr) 1 6/4200 44/43/42/41/40A 30/29/28/26/25A 60A 860W (2.93 kbtu/hr) * Maximum current rating for the cabinet size. If an additional charger is desired, it must be installed in external battery cabinet ASY-0739. Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality 17

Specifications Table 4. Model Specifications for Universal Power Modules (ASY-0528 and ASY-0674) (Continued) Optional Chargers UPS kva/watts Input Current for 200/208/220/230/240V Three-Slot Cabinet Output Current for 200/208/220/230/240V Recommended Input Service Heat Dissipation 2 6/4200 60/59/58/57/56A 30/29/28/26/25A 80A 1145W (3.90 kbtu/hr) 3 6/4200 76/75/74/73/72A 30/29/28/26/25A 100A 1430W 4 6/4200 92/91/90/89/88A 30/29/28/26/25A 125A 1720W 5 6/4200 102A* 30/29/28/26/25A 125A 1995W 0 9/6300 42/40.5/39/37.5/36A 45/43.5/42/39/37.5A 60A 860W (2.93 kbtu/hr) 1 9/6300 58/56.5/55/53.5/52A 45/43.5/42/39/37.5A 80A 1145W (3.90 kbtu/hr) 2 9/6300 74/72.5/71/69.5/68A 45/43.5/42/39/37.5A 100A 1430W 3 9/6300 90/88.5/87/85.5/84A 45/43.5/42/39/37.5A 125A 1720W 4 9/6300 102A* 45/43.5/42/39/37.5A 125A 1995W 0 12/8400 56/54/52/50/48A 60/58/56/52/50A 80A 1145W (3.90 kbtu/hr) 1 12/8400 72/70/68/66/64A 60/58/56/52/50A 100A 1430W 2 12/8400 88/86/84/82/80A 60/58/56/52/50A 125A 1720W 3 12/8400 102/102/100/98/96A* 60/58/56/52/50A 125A 1995W 0 15/10500 70/67.5/65/62.5/60A 75/72.5/70/65/62.5A 100A 1430W 1 15/10500 86/83.5/81/78.5/76A 75/72.5/70/65/62.5A 125A 1720W 2 15/10500 102/99.5/97/94.5/92A* 75/72.5/70/65/62.5A 125A 1995W 0 18/12600 84/81/78/75/72A 90/87/84/78/75A 125A 1720W 1 18/12600 100/97/94/91/88A* 90/87/84/78/75A 125A 1995W * Maximum current rating for the cabinet size. If an additional charger is desired, it must be installed in external battery cabinet ASY-0739. 18 Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality

Specifications Table 5. Model Specifications for Split-Phase Power Modules (ASY-0673) Optional Chargers UPS kva/watts Input Current (200V) Three-Slot Cabinet Output Current (100/200V, 110/220V, 120/240V) Recommended Input Service Heat Dissipation NA 3/2500 16A* 15A, 14A, 12.5A 25A 285W (0.98 kbtu/hr) Six-Slot Cabinet CAUTION: Do NOT install more than three power and/or battery charger modules in a 6-slot cabinet. Optional Chargers UPS kva/watts Input Current (200V) Output Current (100/200V, 110/220V, 120/240V) Recommended Input Service Heat Dissipation 0 3/2500 16A 15A, 14A, 12.5A 25A 285W (0.98 kbtu/hr) 1 3/2500 32A 15A, 14A, 12.5A 40A 570W (1.95 kbtu/hr) 2 3/2500 48A* 15A, 14A, 12.5A 60A 860W (2.93 kbtu/hr) 0 6/5000 32A 30A, 28A, 25A 40A 570W (1.95 kbtu/hr) 1 6/5000 48A* 30A, 28A, 25A 60A 860W (2.93 kbtu/hr) 0 9/7500 48A* 45A, 42A, 37.5A 60A 860W (2.93 kbtu/hr) Nine- and Twelve-Slot Cabinet CAUTION: Do NOT install more than seven power and/or battery charger modules in a 9- or 12-slot cabinet. Optional Chargers UPS kva/watts Input Current (200V) Output Current (100/200V, 110/220V, 120/240V) Recommended Input Service Heat Dissipation 0 3/2500 16A 15A, 14A, 12.5A 25A 285W (0.98 kbtu/hr) 1 3/2500 32A 15A, 14A, 12.5A 40A 570W (1.95 kbtu/hr) 2 3/2500 48A 15A, 14A, 12.5A 60A 860W (2.93 kbtu/hr) 3 3/2500 64A 15A, 14A, 12.5A 80A 1145W (3.90 kbtu/hr) 4 3/2500 80A 15A, 14A, 12.5A 100A 1430W 5 3/2500 96A 15A, 14A, 12.5A 125A 1720W 0 6/5000 32A 30A, 28A, 25A 40A 570W (1.95 kbtu/hr) 1 6/5000 48A 30A, 28A, 25A 60A 860W (2.93 kbtu/hr) 2 6/5000 64A 30A, 28A, 25A 80A 1145W (3.90 kbtu/hr) 3 6/5000 80A 30A, 28A, 25A 100A 1430W * Maximum current rating for the cabinet size. If an additional charger is desired, it must be installed in external battery cabinet ASY-0739. Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality 19

Specifications Table 5. Model Specifications for Split-Phase Power Modules (ASY-0673) (Continued) Optional Chargers UPS kva/watts Input Current (200V) Three-Slot Cabinet Output Current (100/200V, 110/220V, 120/240V) Recommended Input Service Heat Dissipation 4 6/5000 96A 30A, 28A, 25A 125A 1720W 5 6/5000 102A* 30A, 28A, 25A 125A 1995W 0 9/7500 48A 45A, 42A, 37.5A 60A 860W (2.93 kbtu/hr) 1 9/7500 64A 45A, 42A, 37.5A 80A 1145W (3.90 kbtu/hr) 2 9/7500 80A 45A, 42A, 37.5A 100A 1430W 3 9/7500 96A 45A, 42A, 37.5A 125A 1720W 4 9/7500 102A* 45A, 42A, 37.5A 125A 1995W 0 12/10000 64A 60A, 56A, 50A 80A 1145W (3.90 kbtu/hr) 1 12/10000 80A 60A, 56A, 50A 100A 1430W 2 12/10000 96A 60A, 56A, 50A 125A 1720W 3 12/10000 102A* 60A, 56A, 50A 125A 1995W 0 15/12500 80A 75A, 70A, 62.5A 100A 1430W 1 15/12500 96A 75A, 70A, 62.5A 125A 1720W 2 15/12500 102A* 75A, 70A, 62.5A 125A 1995W 0 18/15000 96A 90A, 84A, 75A 125A 1720W 1 18/15000 102A* 90A, 84A, 75A 125A 1995W * Maximum current rating for the cabinet size. If an additional charger is desired, it must be installed in external battery cabinet ASY-0739. 20 Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality

Specifications Table 6. Model Specifications for Split-Phase Power Modules (ASY-0567) Optional Chargers UPS kva/watts Input Current (200V) Three-Slot Cabinet Output Current (200V, 220V, 240V) Recommended Input Service Heat Dissipation NA 3/2100 14A 15A, 14A, 12.5A 25A 285W (0.98 kbtu/ hr) Six-Slot Cabinet CAUTION: Do NOT install more than three power and/or battery charger modules in a 6-slot cabinet. Optional Chargers UPS kva/watts Input Current (200V) Output Current (200V, 220V, 240V) Recommended Input Service Heat Dissipation 0 3/2100 14A 15A, 14A, 12.5A 25A 285W (0.98 kbtu/ hr) 1 3/2100 30A 15A, 14A, 12.5A 40A 570W (1.95 kbtu/ hr) 2 3/2100 46A 15A, 14A, 12.5A 60A 860W (2.93 kbtu/ hr) 0 6/4200 28A 30A, 28A, 25A 40A 570W (1.95 kbtu/ hr) 1 6/4200 44A 30A, 28A, 25A 60A 860W (2.93 kbtu/ hr) 0 9/6300 44A 45A, 42A, 37.5A 60A 860W (2.93 kbtu/ hr) Nine- and Twelve-Slot Cabinet CAUTION: Do NOT install more than seven power and/or battery charger modules in a 9- or 12-slot cabinet. Optional Chargers UPS kva/watts Input Current (200V) Output Current (200V, 220V, 240V) Recommended Input Service Heat Dissipation 0 3/2100 14A 15A, 14A, 12.5A 25A 285W (0.98 kbtu/ hr) 1 3/2100 30A 15A, 14A, 12.5A 40A 570W (1.95 kbtu/ hr) 2 3/2100 46A 15A, 14A, 12.5A 60A 860W (2.93 kbtu/ hr) 3 3/2100 62A 15A, 14A, 12.5A 80A 1145W (3.90 kbtu/hr) 4 3/2100 78A 15A, 14A, 12.5A 100A 1430W 5 3/2100 94A 15A, 14A, 12.5A 125A 1720W 0 6/4200 28A 30A, 28A, 25A 40A 570W (1.95 kbtu/ hr) 1 6/4200 44A 30A, 28A, 25A 60A 860W (2.93 kbtu/ hr) 2 6/4200 60A 30A, 28A, 25A 80A 1145W (3.90 kbtu/hr) 3 6/4200 76A 30A, 28A, 25A 100A 1430W * Maximum current rating for the cabinet size. If an additional charger is desired, it must be installed in external battery cabinet ASY-0739. Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality 21

Specifications Table 6. Model Specifications for Split-Phase Power Modules (ASY-0567) (Continued) Optional Chargers UPS kva/watts Input Current (200V) Three-Slot Cabinet Output Current (200V, 220V, 240V) Recommended Input Service Heat Dissipation 4 6/4200 92A 30A, 28A, 25A 125A 1720W 5 6/4200 102A* 30A, 28A, 25A 125A 1995W 0 9/6300 42A 45A, 42A, 37.5A 60A 860W (2.93 kbtu/ hr) 1 9/6300 58A 45A, 42A, 37.5A 80A 1145W (3.90 kbtu/hr) 2 9/6300 74A 45A, 42A, 37.5A 100A 1430W 3 9/6300 90A 45A, 42A, 37.5A 125A 1720W 4 9/6300 102A* 45A, 42A, 37.5A 125A 1995W 0 12/8400 56A 60A, 56A, 50A 80A 1145W (3.90 kbtu/hr) 1 12/8400 72A 60A, 56A, 50A 100A 1430W 2 12/8400 88A 60A, 56A, 50A 125A 1720W 3 12/8400 102A* 60A, 56A, 50A 125A 1995W 0 15/10500 70A 75A, 70A, 62A 100A 1430W 1 15/10500 86A 75A, 70A, 62A 125A 1720W 2 15/10500 102A* 75A, 70A, 62A 125A 1995W 0 18/12600 84A 90A, 84A, 75A 125A 1720W 1 18/12600 100A 90A, 84A, 75A 125A 1995W * Maximum current rating for the cabinet size. If an additional charger is desired, it must be installed in external battery cabinet ASY-0739. 22 Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality

Chapter 5 Troubleshooting Alarm Messages When the Eaton 9170+ battery charger module is located in a UPS cabinet, the UPS displays alarm messages which involve the battery charger module. Refer to Troubleshooting in the Eaton 9170+ UPS (3-18 kva) User s Guide. Audible Alarms and UPS Conditions When the battery charger module is located in an external battery cabinet, the battery charger module uses an audible alarm feature to alert you of potential power problems. When the alarm is activated, the battery charger module beeps in different intervals according to a particular condition. Use Table 7 to determine and resolve the alarms and conditions. Table 7. Battery Charger Module Audible Alarms Audible Alarm Condition Action 1 short (0.5 sec) Startup Nothing. Module is operating normally. 1 short, pause, 2 short Shorted output error Call your service representative. 1 short, pause, 3 short Battery overvoltage error Call your service representative. 1 short, pause, 4 short Charger failure Call your service representative. Battery Charger Module Replacement The battery charger module may be hot-swapped in a manner similar to replacing power modules or battery modules. This feature enables you to replace the module without disconnecting the load or damaging the UPS. Use care in removing and installing battery charger modules. To replace a battery charger module: 1. Remove the front cover(s) of the cabinet. The covers have spring latches on the left and right sides that hold them in place. 2. Loosen the thumbscrew on the module handle. Press down on the latch release at the center of the module handle and pull the handle down. As the module handle fully extends, the module disconnects. Slide the module slowly out of the cabinet. 3. Use two hands to support the module. When the module is fully extended, lower the front slightly and lift the rear edge over the safety stop on the center support rail. 4. Treat the original and replacement modules with care to avoid damaging connectors or internal circuitry. Label the original module with masking tape or some other identifier. Record the serial number of the replacement module for your warranty. 5. If replacing a battery charger module in an external battery cabinet, verify that the DIP switches on the replacement are set to the same positions as the original. 6. Insert the replacement module by sliding it carefully into the cabinet. Lower the front slightly and lift the rear edge over the safety stop on the center support rail. Keep the module handle extended until the module is fully inserted. 7. Raise the battery charger module handle to secure the module into the cabinet. Be sure the handle latch snaps into place. Tighten the thumbscrew on the handle. 8. Reinstall the front cover(s). Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality 23

Troubleshooting Service and Support If you have any questions or problems with the UPS, call your Local Distributor or the Help Desk at one of the following telephone numbers and ask for a UPS technical representative. United States: 1-800-356-5737 Canada: 1-800-461-9166 ext 260 All other countries: Call your local service representative Please have the following information ready when you call the Help Desk: l l l l l l Model number Serial number Version number (if available) Date of failure or problem Symptoms of failure or problem Customer return address and contact information If repair is required, you will be given a Returned Material Authorization (RMA) Number. This number must appear on the outside of the package and on the Bill Of Lading (if applicable). Use the original packaging or request packaging from the Help Desk or distributor. Units damaged in shipment as a result of improper packaging are not covered under warranty. A replacement or repair unit will be shipped, freight prepaid for all warrantied units. NOTE For critical applications, immediate replacement may be available. Call the Help Desk for the dealer or distributor nearest you. 24 Eaton 9170+ Battery Charger Module (Models ASY-0652 and ASY-0675) User s Guide 164201399 Rev F www.eaton.com/powerquality

*164201399 F* 164201399 F