TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

Similar documents
TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

TEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5

Test report No

European B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd

Test report No

Test report No

Germany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7

Test report No

Test report No

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

Test report no

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

FIRE TEST REPORT FH 5728

FIRE TEST REPORT FH 5078

FIRE TEST REPORT FH 5154

Test report No

Classification report No K1

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces

FIRE REGULATION IN FURNITURE WORLD OVERVIEW

Test Report No.: AJHL FT Date: JUN.02, 2016 Page 1 of 5

Test Report No.: SZTY TS Date: DEC 04, 2012 Page 1 of 10

VAUTH ANALYSING. TESTING. CERTIFYING. aviation components

Test Report No.: SHHG BC Date: JAN.31,2013 Page: 1 of 12

Test report no

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

PRODUCT EVALUATION REPORT

Test report no

MITRAS MATERIALS GMBH

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

Determination Of Fire Effluents From Products On Railway Vehicles

THERMAL SHOCK TEST REPORT

Test Report. No. SHAHG Date: 11 Nov Page 1 of 7.

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

NFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen

The Furniture Retail Quality Group Best Practice Guide

Test Report No.: SDHL FT Date: Jun.15, 2017 Page 1 of 5

CERTIFICATE of QUALITY TEST

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

With Compliments PLEASE FIND ENCLOSED OUR REPORT REFERENCE ALC E : : 1006

Urban Wildfire Interface: Exterior Wall Wildfire Testing

Test Report. No. SHAHG Date: 07 Nov Page 1 of 9.

Durable Goods Labelling Compliance

Test Report No.: AJD Date: NOV.05, 2013 Page: 1 of 5

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:

Laboratory Report. U. S. Department of Justice

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

Oxygen Bomb Calorimeter

Test Report No

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Test Report No.: SHHG MD Date: FEB. 26, 2016 Page: 1 of 17

MIRTA-KONTROL d.o.o. LABORATORY DEPARTMENT

Report Test Report

EU Mutual Recognition Technical Requirements

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)

EN 1154:1997 / A1:2002

TERMINATION TECHNOLOGIES FOR HAZARDOUS AREAS A practical guide

Cast Resin Transformers

Report Number BTC 12024F

Precision engineered to the highest Australian Standards, you ll find Ardent copper fittings and coils for just about every application. Ardent.

FIRE ASSESSMENT REPORT FAR 4659

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

National Standard of People s Republic of China

Technical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications

Flash Point Process Analyzer

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours

Comparison of Styropor and Neopor Expanded Polystyrene Foam Insulations HAI Project No. 1JJB

Test Report. No. SHAHG A01 Date: 10 May Page 1 of 6.

Physical Scaling of Water Mist Protection of 260-m 3 Machinery Enclosure

Verification/Report Number(s): HEARTWAY MEDICAL PRODUCTS Co., Ltd. Applicant Name/Address:

Roofing Tests for European Roofing Products ENV 1187 Test 1, 2, 3 and 4

CONTINUOUS IMMERSION AND DUST TEST REPORT

NovitaTech Engineering

ASTM E 1354 Caloric Content Determination of "3M Polyurethane Adhesive Sealant 540"

OMDEA Oil Mist Detection Efficiency Approval. Maximum false alarm immunity Minimum response time. Opacity over time. opacity. time.

Test Report. CHTC JIAHUA NONWOVEN CO.,LTD No.99,WaGou New Village, Pengchang,Xiantao,Hubei, CHINA

BULDER 00 ROOMHEATER

Test Report. No. SHAEC Date: 23 Apr Page 1 of 5.

Test Report. No. NGBHG Date: 28 Jun Page 1 of 6.

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

14 April 2016 Total Pages: 2. WET PENDULUM SLIP RESISTANCE Job No: M16/10016

TEST REPORT. No. 284a/14

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Page 2 of 23 UNT150420C11

Test Report No.: SDHL FT Date: May 15, 2017 Page 1 of 15

Test Report. No. SHAHG Date: 12 Dec Page 1 of 7.

NFPA 285 TEST REPORT. Report No.: H Test Date: June 1, Rendered to: ARCONIC ARCHITECTURAL PRODUCTS Eastman, Georgia

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

Transcription:

Page: 1 of 5 IGEPA GROUP GMBH & CO. KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : MASTER JET S PREMIUM MESH 270 B1 TORNADO Sample Number : SHCCM130400735 Test Required : To determine the flammability (building materials class B1) in accordance with Product specification : Width 1.10m-3.20m Product or Lot : SBI-PMR Material and Mark : PVC and polyester Date of Receipt : Apr. 25, 2013 DIN 4102-1 (May 1998) Fire behaviour of building materials and elements Part 1: Classification of building materials, requirements and testing Test Period : Apr. 25, 2013 to May. 17, 2013 Test result(s) : For further details, please refer to the following page(s) Signed for SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Sally Xie Authorized signatory

Page: 2 of 5 I. Test conducted This test was conducted as per DIN 4102-15:1990, DIN 4102-16:1998 and DIN 4102-1:1998 Clause 6.2. Classification in according to DIN 4102-1 (May 1998) Clause 6.1-Class B1 materials II. Sample details Color / Density White / 241g/m 2 Size of sample 1000 mm 190 mm, 190 mm 90 mm Conditioning Prior to testing, the sample was conditioned at least 14 days to constant mass at a temperature of 23 ± 2 C, and a relative humidity of 50 ± 6 %. III. Test results 1) Brandschacht Test according to DIN 4102-15 &16 Exposed surface: The Front Face 1 Specimen fixings according to DIN 4102 part 15, table Results of Brandschacht Test (part 1) - 1 2 Max. flame height above lower sample edge; cm 40 3 Time 1) min:s 0:09 Melting/burning through 4 Time 1) min:s 0:01 Back of specimen 5 Flaming/glowing, Time 1) min:s 0:01 6 Discolouring, Time 1) min:s 0:01

Page: 3 of 5 Results of Brandschacht Test (part 2) Burning droplets YES 7 Begin 1) min:s 0:03 Amount / 8 Specimen material falling off in separate droplets / 9 Specimen material falling off continuously Burning parts 10 Begin 1) min:s / 11 Parts of sample falling off separately / 12 Parts of sample falling off continuously / 13 Duration of continued combustion on mesh base (max.) min:s Burner flame impairment by dripping/falling material 14 Time 1) min:s / Premature ending of test / 15 End of burning at specimen 1) min:s / 16 Time when test terminated (if applicable) 1) min:s / Burning after end of test 17 Duration min:s / 18 Number of specimens / 19 Front of specimen / 20 Back of specimen / 21 Height of flame cm / Glowing after end of test 22 Duration min:s / 23 Number of specimens /

Page: 4 of 5 Results of Brandschacht Test (part 3) 24 Front of specimen / 25 Back of specimen / 26 Top half of specimen / 27 Bottom half of specimen / Residual length 28 Single results cm 65 64 64 65 29 Average of the single results cm 64.5 Smoke temperature 30 Max. of average 167 31 Time 1) min:s 10:00 Note: 1) time from start of testing 2) Normal Flammability Test according to DIN 4102-1 Clause 6.2 Flame application: [ ] bottom edge ignition, [ ] surface ignition Specimen 1 2 3 4 5 Reaching the measuring mark within 20 seconds No No No No No Self extinguishing of the flame (s) 15 15 15 15 15 Max. flame height (cm) 7 8 7 9 8 End of afterflaming (s) 15 15 15 15 15 End of afterglowing (s) 15 15 15 15 15 Molten dripping No No No No No Smoke developments (visual impression) Slight All timings are from start of testing Criteria for classification for Class B1 (DIN 4102-1 Clause 6.1.2) All materials, except flooring, may be classed as B1 materials if they met, a) Pass DIN 4102-16 brandschacht test if

Page: 5 of 5 1) The mean value for the residual length of each specimen is at least 15 cm, and no individual values are lower than 0 cm; 2) The mean effluent temperature does not exceed 200 in any test; 3) The requirement for the residual length of each specimen is met even where there is afterflame, afterglow, or smouldering. b) Pass DIN 4102-1 Clause 6.2.3 Ignitability Test if, For each specimen, flaming doesn t reach the gage mark within 20s after flame application. Conclusion: The tested sample meets the low flammability requirements of class B1 of building materials under DIN 4102-1 (May 1998). STATEMENTS: This test report does not replace any mandatory certification of the product that may be required. The test results relate to the behaviour of the test specimens of a product under the particular conditions of the test; they are not intended to be the sole criterion for assessing the potential fire and smoke hazard of the product in use. Note: The test was performed by SGS internal laboratory. Photo Appendix: ********* End of report ********