MTC Series. Marine Temperature Calibrator

Similar documents
MTC series. Marine Temperature Calibrator. temperature. » Wide temperature range

ITC series. Industrial Temperature Calibrators. Portable and easy-to-use temperature calibrator

ITC series. Industrial Temperature Calibrators. Portable and easy-to-use temperature calibrator

Model ITC-155/320 and 650 Industrial Temperature Calibrator

CTC series. Compact Temperature Calibrators. Fast, timesaving, and reliable true temperature calibrator. Specification Sheet

Model CTC-series Compact Temperature Calibrator

CTC-series. Compact Temperature Calibrator. temperature

CTC Series. Compact Temperature Calibrator. temp erature. Specification Sheet SS-CP-2281-US Page 1 of 8 NOW

Model CTC-series Compact Temperature Calibrator

CTC series. Compact. Calibrators. Temperature. Fast, timesaving, and reliable true temperature calibrator

Model ATC-125 Advanced Temperature Calibrator

Model ATC-156/157/320 and 650 Advanced Temperature Calibrator

ATC series JOFRA TM. Advanced Temperature Calibrator. Your choice for optimum temperature calibration. Specification Sheet NOTICE

Model ATC-140/250 Advanced Temperature Calibrator

Model ATC-125. Advanced Temperature Calibrator. Patented! t e m p e r a t u r e

User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A

User manual ma Loop Calibrator Jofra macal

Reference manual Temperature Calibrator JOFRA MTC-140/320/650 A

User Manual Compact Temperature Calibrator Jofra CTC-155/350/660 A/C

HPC600. Handheld Pressure Calibrator. Built-in electric pump. pressure

J O F R A. t e m p e r a t u r e. c a l i b r a t i o n. i n s t r u m e n t s

Dry Block and Liquid Bath Temperature Calibrator Series

Temperature multi-function calibrator Model CTM

Dry Block and Liquid Bath Temperature Calibrator Series

Reference Manual Temperature Calibrator JOFRA ITC-155/320/650 A Copyright 2002 AMETEK DENMARK A/S

Model Type T Hydraulic Deadweight Tester

Thermo Scientific Variomag Magnetic Stirrers

500/800. CalTrak. High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry. FEATURES DESCRIPTION

P014 Hydraulic Jack Pump Operation Manual for P014 and System E

ADTS542F. Your touch, our technology. Wireless ADTS500 Series Easy-to-Use Pitot Static Tester. Features

ADTS542F. Your touch, our technology. GE Oil & Gas. Wireless ADTS500 Series Easy-to-Use Pitot Static Tester. Features

Reference manual Industrial Temperatur Calibrator Jofra ITC-155/320/650 A

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

P014 Hydraulic Jack Pump Operation Manual for P014 and System E

User- and Reference manual Temperature Calibrator JOFRA ETC-125 A / 400 A / 400 R Copyright 2005 AMETEK DENMARK A/S ( UK)

Reference manual Compact Temperatur Calibrator Jofra CTC-140/320/650 A/B Jofra CTC-1200 A

Reference Manual Handheld Pressure Calibrator JOFRA HPC400

Beamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications

ADTS550F. Your touch, our technology. GE Measurement & Control. (ADTS552F, ADTS553F, ADTS554F) Wireless ADTS500 Series Easy-to-Use Pitot Static Tester

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

P-Series Screw Pump. Operation Manual for P016, P017, and P-018-CPF Pressure Pumps

Pressure Transmitter

Industrial Pressure Indicator

ASC300. Advanced Signal Calibrator. Process signal calibrator with superior accuracy. Specification Sheet

TURBOMOLECULAR PUMPS ATP SERIES

Part No. 01/3955 July LS Series Contacting Extensometer. User Manual. LS Series Contacting Extensometer User Manual 1

UNIVERSAL TESTING MACHINES STENTOR II CC & ATLAS II CC

MJÖLNER 200 Microhmmeter

Type T Pump. Operation Manual for T-1and T-1-CPF

Low Profile Insertion Vortex

PRIME MOVER CONTROLS INC. MARINE PROPULSION CONTROLS. Series MPC-CP SYSTEM

Model Type T Hydraulic Deadweight Tester

RCM. Direct Reading Flowmeter. for Liquids or Gases

User- and Reference manual Temperature Calibrator JOFRA ETC-125 A / 400 A / 400 R

Industrial Pressure Indicator

MIT515, MIT525, MIT1025, MIT1525

HUMIDITY / TEMPERATURE TRANSMITTER

Reference Manual Professional Temperature Calibrator Jofra PTC-125/155/350/425/660 A/B/C

TOP SMART intelligent position monitor:

Temperature Calibration Guide

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

5 kv and 10 kv Insulation Resistance

3000 SERIES DRY-BLOCK HEAT SOURCE

UNIVERSAL TESTING MACHINERY STENTOR II CC - ATLAS II CC - T-DRIVE CC

F-2700 SERIES INSERTION VORTEX FLOW METER

AUTOMATED TORSION BENCH DRIVETWIST

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A Copyright 2005 AMETEK DENMARK A/S ( UK)

Industrial Pressure Indicator

530 Power. Grounding. Line voltage. Caution. A proper earth ground is required for GC operations.

PIT, PIF & PIX Pressure-to-Current Transmitters

Fluke 500 Series Battery Analyzers

Automated Precision Weighing

Viscomaster TM. Viscosity- and Density-Solutions for fuel oil applications.

The FMM force tester can be controlled using L1 software for limit, cycling, hold and coefficient of friction testing.

Digital Insulation Resistance Testers. you can depend on

Z+ Series. 200W, 400W, 600W and 800W Programmable DC Power Supplies. Z+ Series 1. Model Selector. Minimises system rack height

Automated Precision Weighing

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

SSP-Series Portable Balances Operation Manual

REVOLUTIONIZE YOUR GAS DENSITY AND PURITY MEASUREMENT TECHNOLOGY

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

MIT515, MIT525 and MIT & 10 kv DC Insulation Resistance Testers

Thermo Scientific Sorvall MTX and MX Plus Micro-Ultracentrifuge Series. powerful separation technology. quiet, compact design

F-2600 SERIES INLINE VORTEX FLOW METER

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

COMPACT DRY PUMPING SYSTEMS DRYTEL SERIES

PIECAL 520B & 521B Thermocouple Source Operating Instructions

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

Low Profile DC Power Supply with Zero Voltage Soft Switching

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

PIT, PIF & PIX. Features. Pressure-to-Current Transmitters

Thermo Scientific Hot Plates, Stirrers and Stirring Hot Plates

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

Viscomaster TM series viscosity transmitters for marine and power HFO applications

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

F-2700 SERIES INSERTION VORTEX FLOW METER

Transcription:

MTC Series Marine Temperature Calibrator

Save Time, Save Money Up to 3 Year Calibration Interval Maximize accuracy with a one year recommended calibration interval, or lower your cost of ownership by extending your interval up to three years! Reduce costs associated by recalibration and managing assets by 66%. With wide temperature ranges from -17 to 650 C / 1 to 1202 F, the MTC series of portable temperature calibrators facilitates correct readings on all of your temperature monitoring devices. Maintain and Calibrate monitoring devices for: Fast Calibration The MTC-320 A and the MTC-650 A contain an innovative heating block profile, which heats up to 320 C / 608 F in just 4 minutes, and up to 650 C / 1202 F in only 10 minutes. The special heating profile minimizes mass and yet, still accepts an insertion tube with a 1 in (26 mm) outer diameter. It s the perfect compromise between temperature stability, homogeneity, and rapid heating and cooling. Fuel oil inlet Exhaust gas Crankcase protection Turbine & gear bearings Steam Servo oil propeller pitch Purifiers Starting air Hydraulic systems Oil burner Lubricating oil systems Scavenge air Sea water cooling Charge air Uptake gas Feed water Cooling water outlet Refrigeration systems Gland steam Condensing system Easy to Read, Intuitive Operation Avoid confusing sub-menus or multiple keystroke combinations with simple one-key, one-function logic. Access primary features like automatic switch test and auto-stepping directly from the main screen. The backlit display features dedicated icons, which help in identifying instrument conditions and operational steps. Generators Safety Valves Turbo-charger lubrication Main steam Condensers Cylinder/piston/fuel valve cooling media Thrust/shaft/plane/stern tube bearings

Useful Features MVI Mains power Variance Immunity improves temperature stability Unstable mains power supplies are a major contributor to on-board calibration inaccuracies. Traditional temperature calibrators often become unstable in shipboard environments where large electrical motors, heating elements, and other devices Auto Switch Test Auto Stepping Program the slope rate from 0.1 to 9.9 C/ F. The Program up to 9 steps with dwell times on each step. MTC will store the Open, Close, and Deadband Monitor sensor output from the control room or values. Use the feature to ensure repeatability when bridge, while the MTC performs auto step functions testing thermo-switches. from the engine room. Or burn-in new sensors prior to installation. are periodically cycled on and off. The cycling of supply power can cause lower quality temperature regulators to perform inconsistently, leading to both inaccurate readings and unstable temperatures. The MTC series calibrators MTC-320 A and MTC-650 A employ the MVI, thus avoiding such stability problems. The MVI circuitry continuously monitors the supply voltage and ensures a constant energy flow to the heating elements. Interchangeable Inserts Maximum Temperature Not limited by fixed holes. Interchangeable Select a maximum temperature limit for the insertion tubes are used to match the diameter of calibrator, avoiding damage to the sensor-under- the sensor-under-test. test by excessive temperatures. Reduces drift resulting from extended periods of exposures to high temperature. Mains MVI Normal

Multi-Information Display Dual Readings Set and read temperatures simultaneously. Calibrate and Adjust Anywhere Stability Indicator The bold checkmark on the display indicates that the calibrator has reached the desired temperature and is stable. A convenient countdown timer is activated five minutes before the unit reaches stability. Messages and Icons Display alphanumeric message and status icons. Instrument Setups Stores the complete instrument setup, including engineering units, stability criteria, resolution, display contrast, slope (ramp) rate, auto-step settings, and maximum temperature. Set Temperature The Up and Down arrow keys allow the user to set the exact temperature desired, with a resolution of 0.1 C or F. The MTC series has a very easy and straightforward procedure for re-calibration and adjustment. There is no need for a screwdriver or PC software. The only thing you need is a reliable reference thermometer. Simply place the probe in the calibrator and follow the instructions on the display. The unit s serial number, software revision level, and the last calibration date is easily accessible.

Specifications Mains Power Voltage...115 V (90-127) / 230 V (180-254) Max Power Consumption.... (MTC-140 A) 150 VA Max Power Consumption.... (MTC-320 A / 650 A) 1150 VA Frequency, US deliveries... 60 Hz ±5 Frequency, non US deliveries... 50 Hz ±5, 60 Hz ±5 Temperature All specifications are given with an ambient temperature 23 C/73.4 F ± 3 C/5.9 F. Specified at 115 V/230 V. Accuracy 1 Year MTC-140 A...±0.4 C /±0.72 F MTC-320 A... ±0.5 C /±0.9 F MTC-650 A...±0.9 C /±1.62 F 3 Year MTC-140 A... ±0.8 C /±1.44 F MTC-320 A... ±1.2 C /±2.16 F MTC-650 A... ±1.8 C /±3.24 F Specification when using the internal reference. (Load 4 mm OD reference probe in the center of the insert). Range MTC-140 A Range...-17 to 140 C / 1 to 284 F Cooling Capacity @ ambient of 0 C / 32 F... -30 C / -22 F Cooling Capacity @ ambient of 23 C / 73 F...-17 C / -1 F Cooling Capacity @ ambient of 40 C / 104 F...-2 C / 28 F Range MTC-320 A Range... 33 to 320 C / 91 to 608 F Range MTC-650 A Range...33 to 650 C / 91 to 1202 F Settings Resolution... 1 or 0.1 Units... C or F Temperature (cont.) Stability MTC-140 A... ±0.05 C / ±0.09 F MTC-320 A / 650 A.... ±0.1 C / ±0.18 F Measured after the stability indicator has been on for 10 minutes. Measuring time is 30 minutes. Time to Stability (typical) MTC-140 A...5 minutes MTC-320 A / 650 A....8 minutes Heating Time MTC-140 A... -17 to 23 C / 1 to 73 F....3 minutes MTC-140 A...23 to 140 C / 73 to 284 F... 15 minutes MTC-320 A...33 to 320 C / 91 to 608 F....4 minutes MTC-650 A... 33 to 650 C / 91 to 1202 F... 10 minutes Cooling Time MTC-140 A... 140 to 100 C / 284 to 212 F....2 minutes MTC-140 A... 100 to 0 C / 212 to 32 F... 10 minutes MTC-140 A...0 to -15 C / 32 to 5 F... 13 minutes MTC-320 A... 320 to 100 C / 608 to 212 F... 16 minutes MTC-650 A... 650 to 100 C / 1202 to 212 F... 28 minutes Physical Specifications Dimension L x W x H.. 241 x 139 x 325 mm / 9.5 x 5.5 x 12.8 in Weight MTC-140 A...6.5 kg / 14.3 lb MTC-320 A... 5 kg / 11 lb MTC-650 A...6.4 kg / 14.1 lb Immersion Depth MTC-140 A (insulation included)...115 mm / 4.5 in MTC-320 A/650 A...110 mm / 4.3 in Insert Dimensions (diameter x length) MTC-140 A...19 mm x 100 mm / 0.75 x 3.9 in MTC-320 A/650 A... 26 mm x 120 mm / 1 x 4.7 in Electrical Switch Input (dry contact) Test Voltage.... Maximum 5 VDC Test Current.... Maximum 2.5 ma Digital Interface RS232 (9-pin Male) Environmental Operating Temperature 0 to 40 C / 32 to 104 F Storage Temperature -20 to 50 C / -4 to 122 F Humidity Up to 90% Rh Protection Class IP-10 Certificates CE.... 2004/108/EC : EN61326-1: 2006 2006/95/EC : EN61010-1:2010 EN61010-2-030 : 2010 DNV...Marine type approval from Det Norske Veritas. See the certificate at ametekcalibration.com Shipping Weight With Standard Accessories MTC-140 A... 10 kg / 22 lb MTC-320 A...8 kg / 17.5 lb MTC-650 A...9.5 kg / 21 lb Size: L x W x H...410 x 250 x 370 mm / 16.2 x 9.8 x 14.6 in With Standard Accessories and Rugged Carrying Case MTC-140 A... 13 kg / 28.6 lb MTC-320 A... 11 kg / 24 lb MTC-650 A... 12.5 kg / 27.6 lb Size: L x W x H... 515 x 200 x 390 mm /20.3 x 7.9 x 15.4 in

MTC Series Inserts Inserts for MTC-140 A and MTC-320 A are made of aluminum. Inserts for MTC-650 A are made of brass. All specifications on hole sizes refer to the outer diameter of the sensor-under-test. The correct clearance size is applied in all predrilled inserts. Predrilled Inserts metric (mm) Part Numbers Probe Diameter Insert Code 1 MTC-140 A 2 MTC-320 A MTC-650 A 3 mm 003 123428 123436 123444 4 mm 004 60F451 100177 100196 5 mm 005 123429 123437 123445 6 mm 006 60F453 100179 100198 7 mm 007 123430 123438 122516 8 mm 008 105185 100182 100201 9 mm 009 105186 100183 100202 10 mm 010 105187 100185 105188 11 mm 011 123431 100188 100204 12 mm 012 123432 100186 100206 13 mm 013 123433 60F339 105189 14 mm 014 N/A 100190 100208 15 mm 015 N/A 100191 100209 16 mm 016 N/A 123439 123446 18 mm 018 N/A 123440 122517 20 mm 020 N/A 123441 122518 Package of the above inserts 124679 124681 124685 Multi-hole type 1 M01 123479 3 123475 123476 Predrilled Inserts imperial (in) Part Numbers Probe Diameter Insert Code 1 MTC-140 A 2 MTC-320 A MTC-650 A 1/8 in 125 60F450 100176 100195 3/16 in 187 60F452 100178 100197 1/4 in 250 60F454 100180 100199 5/16 in 312 60F456 100181 100200 3/8 in 375 60F458 100184 100203 7/16 in 437 60F460 100187 100205 1/2 in 500 60F462 100189 100207 9/16 in 562 60F464 60F344 60F408 5/8 in 625 60F466 100192 100210 11/16 688 N/A 60F348 60F412 3/4 in 750 N/A 100193 100211 3/16 in 813 N/A 60F352 60F416 7/8 in 875 N/A 60F354 60F418 Package of the above inserts 124680 124682 124686 Multi-hole type 2 M02 123480 3 123477 123478 Note 1: Use the insert code when ordered as the standard insert together with a new calibrator. Note 2: MTC-140 A only: Remember to use matching insulation plugs. Note 3: MTC-140 A only: All multi-hole inserts are delivered with a matching insulation plug. Undrilled Inserts Part Numbers Inserts MTC-140 A MTC-320 A MTC-650 A 5-pack 60F448 100175 100194 Insulation Plug MTC-320/650 A Inserts 3 6 9 3/8 123937 N/A N/A 5 4 1/8 3/16 1/4 Typical Weight MTC-320 A: 5.8 oz/170 g MTC-650 A: 17.8 oz/510 g Multi-hole M01 Multi-hole M02 MTC-140 A Inserts Typical Weight 4 3 3/16 MTC-140 A: 2.6 oz / 75 g Undrilled 5 6 1/4 1/8 Multi-hole M01 Multi-hole M02 Undrilled

Ordering Information Base Model Number MTC140A MTC-140 A, -17 to 140 C (-1 to 284 F) MTC320A MTC-320 A, 50 to 320 C (122 to 608 F) MTC650A MTC-650 A, 50 to 650 C (122 to 1202 F) Power Supply (US deliveries 60 Hz only) 115 115 VAC 230 230 VAC Mains Power Cable Type A European 230 V B USA/Canada 115 V C UK 240 V D South Africa 220 V E Italy 220 V F Australia 240 V G Denmark 230 V H Switzerland 220 V I Israel 230 V Standard Delivery MTC dry-block calibrator (user specified) Mains power cable (user specified) Traceable certificate - temperature performance Insert (user specified) Tool for insertion tubes User manual Test cables (1 x red, 1 x black) RS232 cable JOFRACAL calibration software MTC-140 A includes 3 pieces insulation plugs (p/n 123469). Insert Type and Size 1x insert for dry-block configuration XXX (Please see insert section for correct code.) Calibration Certificate F H Traceable Calibration Certificate 17025 Accredited Calibration Certificate (Optional) Option C Rugged Carrying Case MTC650A 230 AM01FC...JOFRA MTC-650 A with standard accessories, 230 VAC, European power cord, multi-hole type M01, NPL traceable certificate, and carrying case.

Accessories 122832....Cleaning Brushes - 4 mm - Package of 3 pcs 60F174...Cleaning Brushes - 6 mm - Package of 3 pcs 22822....Cleaning Brushes - 8 mm - Package of 3 pcs 65-F100....Insulation in Tube, 100 mm x Ø25 mm 65-F101....Insulation in Tube, 150 mm x Ø25 mm 65-F102....Insulation in Tube, 200 mm x Ø25 mm 65-F103....Insulation in Tube, 250 mm x Ø25 mm 65-F104....Insulation in Tube, 300 mm x Ø25 mm 65-F105....Insulation in Tube, 350 mm x Ø25 mm 65-F106....Insulation in Tube, 400 mm x Ø25 mm 65-F107....Insulation in Tube, 450 mm x Ø25 mm 123469....Set of 3 pcs insulation plugs for MTC-140 A 123408....Carrying Case United Kingdom Tel +44 (0) 1243 833 302 jofra@ametek.co.uk USA, Florida Tel +1 (800) 527 9999 cal.info@ametek.com Singapore Tel +65 6484 2388 jofra@ametek.com France Tel +33 (0) 30 68 89 40 general.lloyd-instruments@ametek.fr USA, California Tel +1 (800) 444 1850 crystal@ametek.com India Tel +91 22 2836 4750 jofra@ametek.com China, Shanghai Tel +86 5868 5111 jofra-china.sales@ametek.com.cn China, Beijing Tel +86 10 8526 2111-19/24/25 jofra-china.sales@ametek.com.cn Germany Tel +49 (0) 2159 9136 510 info.mct-de@ametek.de Denmark Tel +45 4816 8000 jofra@ametek.com www.jofra.com No part of this document may be reproduced or modified in any form or by any means, electronic or mechanical, without express written permission from Crystal Engineering Corporation. SS-MTC_Marine Issue 0515 2015 AMETEK Incorporated