RA / /3, 4/2 and 3/2-Way Directional Valves Model.WE 10.../.D, Series 3X with Wet Pin DC Solenoids. Functional description, section

Similar documents
4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

RA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min)

Pump Safety Block Model DBA... / DBAW, Series 1X

29 160/ Proportional Pressure Relief Valve Model DBE, (Series 5X) Ordering Code DBE 5X Y G24 1/ PSI (350 bar)

29 158/ Proportional Pressure Relief Valve Models DBE and ZDBE, Series 1X. Ordering code DBE 6 1X G24 1/ PSI (315 bar)

B8_58 (EDBZ-VEI) RE Edition: Replaces:

3/2 and 4/2 directional poppet valve with solenoid actuation

Proportional pressure reducing valve of 3-way design

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

Gear Pump Model G4, Series 2X

Proportional pressure reducing valve, in 3-way version

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

X 7 WK Electrically operated directional spool valve with a soft-shift function type WE6P NUAL NS6. up to 35 MPa up to 80 dm APPLICATION

Modular valves DO5 (NG 10) 315 bar

Directional Control Valves. General Description. Operation. Features

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ)

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Rexroth Hydraulics. Pressure reducing valve, pilot operated, type 3DR 3DR 10 P 6X Y 00 RE /10.97

Proportional pressure reducing valve of 3-way design Types 3DREP and 3DREPE

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 directional spool valve, direct operated with solenoid actuation

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Directional Control Valve Series D3W Soft Shift

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

3/2 and 4/2-way Directional Poppet Valves with Solenoid Operation Model M-SED 6, Series 1X. Size 6 (350 bar) H/A 4243/94

Proportional pressure reducing valve, 3-way variant, pilot operated

Bar 35 PSI 500. Pressure Drop L/M GPM. Flow

Proportional flow control valve with integrated pressure compensator Type KUDSR

Meter-in pressure compensator, direct operated

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

2/2 directional seat valve, direct operated with solenoid actuation

Directional Control Valve Series 4D01 (DENISON)

Direct Operated Proportional DC Valves

4/2 Directional valve elements with or without secondary relief valves, with or without LS connections, and with 2/2 solenoid cartridge valve

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

Pilot operated pressure relief valve

CMF2 Series Applicable cylinder bore size: Max. ø160

Directional Control Valve

RA / Radial Piston Motor Model MR, MRE Fixed Displacement. Table of Contents. Replaces: RA /10.95

Directional Controls

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 SK (high-performance)

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99

DIRECTIONAL CONTROL (LD) DIRECTIONAL AND FLOW CONTROL (LD) SOLENOID OPERATED DIRECTIONAL

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

3/2 and 4/2 directional seat valves with solenoid actuation

Directional Control Valves. Features. Application. Operation

4/3-4/2 Directional valve elements B8_0A with or without (EDB-A) secondary relief valves, with or without LS connections B8_0A (EDB-A)

Proportional flow control valve, with integrated pressure compensator

Directional spool valves, direct operated, with solenoid actuation. Type WE. Contents. Features. RE Edition: Replaces:

BST / BSG-03 / 06 / 10 Threaded Connections / Sub-plate Mounting. Specifications / Model Number Designation. Max. Flow L/min (U.S.GPM) Double Sol.

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance)

Open center control block in mono block design MO-16, 22, 32

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Directional spool valves, direct operated, with solenoid actuation. Type WE

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

2-way flow control valve

Directional Control Valve Series D1VW

Throttle check valve. Type Z2FS. Size 16 Component series 3X Maximum operating pressure 350 bar [5076 psi] Maximum flow 250 l/min [66 US gpm]

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents

Directional Control Valves. General Description. Operation. Features

Solenoid Pilot Operated Directional Control Valve

Fixed Displacement Motor AA2FM (A2FM)

Proportional pressure reducing valve, pilot operated

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

4/2, 4/3, and 5/2, 5/3 proportional directional valve, pilot operated, without electrical position feedback without/with integrated electronics (OBE)

Pressure reducing valve, pilot operated

2-way proportional throttle valve for block installation

Pipe burst safety valve Type MHRB

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve

Directional Controls

Directional Controls

Pilot-Operated Directional Control Valves Series D3 - D11

Single-circuit power brake valve LT 05

Directional Seat Valve Series D4S (Denison)

Proportional flow control valve. Type 2FRE. Features. Contents. RE Edition: Replaces: 02.07

Directional Control Valves, electrically operated Type WE 5 Huade América 1

2/2-way poppet valves with solenoid operation Type KSDER1

Directional Control Valves. General Description. Operation. Features

Industrial Hydraulics FAQs

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Directional Control Valves

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

VPN2-10/MR. Functional Description HU /2008. Pilot Operated Pressure Relief Valves. Replaces HU /2005

Proportional pressure reducing valve, pilot operated

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents. RE Edition: Replaces: 04.

Proportional pressure relief valve Type DBETRE

Differential Lock Valve

Transcription:

4/3, 4/2 and 3/2-Way Directional Valves Model.WE.../.D, Series 3X with Wet in DC Solenoids Size (D )... 3 SI... 2 GM (2 ar) (8 L/min) RA 23 37/6.98 Replaces: 2.96 Features: Direct solenoid operated directional spool valve, Mounts on standard ISO 44-, NFA 3..M R and ANSI 93.7 D interface Wet pin DC solenoids, Solenoids with central armature and removale coils, Coils may e easily replaced without engaging fluid, Individual electrical connections, see data sheet RA 8 2, Manual override standard. H/A 48/94 Model 4 WE E3X/ D G24N9Z4 Functional description, section A a Model 4WE E3X/DG24N9K4 A A 2 4 3 4 2 Directional valves, type WE are solenoid operated directional spool valves. hey control the start, stop and direction of a flow. Directional valves consist of housing (), removale solenoid(s) (2), control spool (3) and return spring(s) (4). De-energized, spool (3) is held centered, or an offset position y return springs (4). Spool (3) is shifted y wet pin solenoid(s) (2). In order to ensure correct function, the solenoid armature must e filled with oil. (Cycling the valve will typically permit the armatures to fill). De-energizing solenoid (2), spool (3) returns to the original position y return springs (4). Manual override () permits movement of control spool (3) without electrical power. Orifice insert (Model 4WE..3X/.../..) An orifice insert is required if, flows are higher than the permitted pulished power limits of the valve. he orifice is installed in port. he force of solenoid (2) acts upon control spool (3) and moves it from an original position to the desired position. Solenoid engagement permits flow from to A and to or to and A to. O-ring 2 x 2 /6

Symols a a a a a a = A = C = D a a a a a a =.A =. ) Example: Spool E with spool position a Ordering code 4 WE EA-3X/DG 24 N9 Z4 = E ) = L = G = M = = H = Q = Y = J = U Ordering code 2 3 4 6 7 9 2 9 22 23 WE 3X D * 3 service ports = 3 4 service ports = 4 Size (D ) = Spool type e.g. C, E, EA, E etc. For possile spool configurations, see aove Series 3 to 39 (3 to 39: externally interchangeale) = 3X Spring return = no code Wet pin solenoid with removale coil = D 24 V DC = G24 96/96 V DC solenoid, with integrated rectifier in plug connector, = W R for V or 22 V AC, independent of frequency = W 22 R (only possile with plug Z) (For further ordering data for other voltages, see page 3) with protected manual override = N9 Further details in clear text no code = NR seals; suitale for use with petroleum oil (HM, HL, HL) no code = without cartridge throttle 8 = throttle,.8 mm dia. = throttle,. mm dia. 2 = throttle,.2 mm dia. For use when flows exceed power limits of valve, installation in port Electrical connections to data sheet RA 8 2 Individual connection K4 ) = with protective cap, no connector Z4 = lug-in connector to DIN 43 6 Z = Large plug-in connector ZL = Large plug-in connector with lamp ) lug-in connectors (Z4, Z) have to e ordered seperately (see RA 8 ) 2/6

echnical data (For operation outside these parameters, please consult us!) General Installation position Optional Max. amient temperature F ( C) 22 () Weight Valve with solenoid ls (kg) 8.6 (3.9) Valve with 2 solenoids ls (kg) 9.7 (4.4) RA 23 37/6.98 Hydraulic Max. permissile ort A,, SI (ar) 3 (2) nominal pressure ort SI (ar) 3 (2) Max. flow GM (L/min) 2 (8) Hydraulic fluid etroleum oil (HM, HL, HL) Fluid temperature range F ( C) 22 to 76 ( 3 to 8) Viscosity range SUS (mm 2 /s) 3 to 23 (2.8 to ) Fluid cleanliness Maximum permissile degree of contamination of fluid to ISO 446 Class 8/. We therefore recommend a filter with a minimum retention rate of ß 7. Electrical Voltage type DC AC 2 ) Voltages ) V 2, 24, 96, 96, 22, 24 ower consumption W 3 Duty cycle continuous Operating time to ON ms 3 to ISO 643 OFF ms to 2 Operating frequency Cycles/hour Insulation Exceeds NEMA class Coil temperature F ( C) up to 32 () ) Other voltages on request 2 ) An AC voltage supply requires a rectifier, example WE 3X/DWRN9Z When making the electrical connection, the ground screw ( ) must e connected to earth ground. 3/6

p-q V Operating curves, measured at ν = 9 SUS (4 mm 2 /s) and t = 22 F ( C) Operating pressure in SI (ar) (7) (6) () (4) (3) (2) () 8 6 4 2 7 3 2 8 4 6 Symols Direction of flow A A A, C, Q 2 2 2 2 D, Y 3 3 3 3 E 4 4 2 2 G H J 2 2 6 6 M L 4 8 8 U 8 4 8 Mid pos. A A G 7 4 8 2 6 2 () (2) (3) (4) () (6) (7) (8) Flow in GM (L/min) erformance limits, measured at ν = 9 SUS (4 mm 2 /s) and t = 22 F ( C) ecause of silting, the shifting function of the valves is dependent upon filtration. o otain the maximum flow values shown, full filtration of 2 µm is recommended. he flow forces acting within the valve also influence performance. In 4-way valves, the data provided is for applications with 2 directions of flow (flow from to A and an equal, simultaneous return from to, see tale). If only one direction of flow is required, for example, when a 4- way valve has one port plugged, or unalanced flows from large rod cylinders, the permissile flow in critical cases can e consideraly lower. he A or spool (3-way) can e used as an approximation of the limited flow performance. erformance limits measured with solenoids at operating temperature, % undervoltage and without tank port pressure. (2) (2) (8) (6) 3 2 Curve Spool type Q, L, U 2 J 3 G 4 A, C, D, E, H, M, Y Operating pressure insi (ar) (4) (2) () (8) (6) 2 2 3 4 (4) (2) 4 8 2 6 2 () (2) (3) (4) () (6) (7) (8) Flow in GM (L/min) 4/6

Unit dimensions: dimensions in inches (millimeters) RA 23 37/6.98 3.8 (9) 2.26 (4).728 (8.) 2.7 (7) A A 8 3 9 2 8 ightening torque (typical) 2 in-ls + 7 in-ls (6 Nm + 2 Nm) 7.6 6. 4. 6. 4. 6.2 7 ().6 () A ø.433 (ø) 4.94 (4) N 4.2 (8) ø.29 (6.6).8 (3).7 (4) 2.72. 3.3 (69) (2.) (79.) 3.43. 2.72 (87) 6.6 (4) (69) (66.) 3-position valve 2 2-position valve with solenoid (A, C, D, EA...) 3 2-position valve with solenoid (, Y, E...) 4. Solenoid a 4.2 Solenoid Space required to remove solenoid 6. lug-in connector Z4 (may e rotated in 9 increments) 6.2 Large plug-in connector Z and ZL (may e rotated in 9 increments) 7 Space required to remove plug 6.6 (66.) 8.98 (228) 2 3 8 Manual override, N9 (manual operation only possile up to 72 SI ( ar) tank pressure), do not damage the manual override ore. Handkno part # RR 24943 may e used. 9 Nameplate R ring 3 mm x.6 mm x 2 mm (for valve with cartridge throttle: O ring 2 mm x 2 mm) Screw plug for valves with single solenoid 2 Additional port () may e used where valve is mounted on suitaly drilled manifold..4/4. in./ mm 32 (R max 4) Required surface finish of interface when mounting the valve without our suplate 3 orting pattern to ISO 44-, NFA 3..M R and ANSI 93.7 D Suplates G 66/ (3/8" N); G 66/2 (SAE-6; 9/6-8); G 67/ (/2" N); G 646/2 (SAE-; 7/8-4); G 34/ (3/4" N); G 34/2 (SAE-2; -/6-2) Valve mounting olts /4-2x2 in (M6 x 4) [tightening torque =.4 ft-ls (. Nm)], must e ordered separately. /6

Ordering code, availale spare parts and seals Individual connection 3 3 6 3 7 Spare parts Solenoid DC Voltage Item Description Voltage Order numer 7 Coil for individual connection 2 V RR 2388 24V RR 2389 6 Hand nut RR 297 O-Ring RR 8263 Seal kit Valve: lug connector Z Item Seal Material Order numer 3 NR seals RR 3282 FM seals RR 3283 6/6 Mannesmann Rexroth Corporation Rexroth Hydraulics Div., Industrial, 23 City Line Road, ethlehem, A 87-23 el. (6) 694-83 Fax: (6) 694-8467 Rexroth Hydraulics Div., Moile, 7 Old Mansfield Road, Wooster, OH 4469-394 el. (33) 263-34 Fax: (33) 263-3333 All rights reserved Suject to revision rinted in U.S.A.