Fixed Rack Mount Kit (24-32 )

Similar documents
Cabinet and Rack Installation

Cabinet and Rack Installation

Cabinet and Rack Installation

Cabinet and Rack Installation

6U Vertical Server Cabinet - 30 in. depth

Installing the ONS M6 Shelf

1000 Park Drive Lawrence, PA Fax

Raidtec Rack Mount Guide Version 2.1

Raidtec 20-Inch Rack Mount Guide Version 1.0

Rack Installation Guide (Steelhead Series 3000, 5000, and 6000, and Interceptor Systems)

Installation Instructions

Installation Instructions

2-Post Rack Mount Kit Installation Instructions

TC B

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

A-dec 570L Dental Light on a Non-DCS System INSTALLATION GUIDE

PDU Input Power Cord. Before installation. Specifications

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

Declaration of Conformity

Power Distribution Units

GT-Series GlobalFrame Gen 2 Cabinet System

5-Slot and 2-Slot Panels Installation Guide

1.866.TRY.GLCC WeRackYourWorld.com

RECUMBENT ASSEMBLY GUIDE

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Mounting an EX 8200 series Switch on a Rack or Cabinet Without Using a Mechanical Lift

Be Strong. Assembly Manual Commercial Series Bike U916. Model: U916. P/N: Rev D (03/28/07)

1 Match Shade to Window. Sivoia QEDTM Installation Instructions

TS , -850 Series TS , -850 Series TS-57031, TS

Installation. InfraStruXure PDU 80kW PD80F6FK1-M-14 PD80F6FK1-M PD80G6FK1-M PD80G6FK1-M-14

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

Cabinets 19" lab racks

Mid-Power Remote Unit (MRU) SISO Outdoor Enclosure Assembly Quick Installation Sheet

INLET DUCT FOR CISCO 9513 SWITCH Part Number: DIBBC2314S21W

NOVASTAR FRAME TOOLSET

PowerFlex 700H and 700S AC Drives Frame 9 Main Fan Capacitor Replacement Kit

Installing the Switch Chassis

S6 BATTERY REPLACEMENT

HP Adjustable Depth Fixed Rail Kit Installation

LT Charging Cart for Laptops

ChargePoint Gateway Installation Instructions

SYSTIMAX 360 FTP Evolve Panel Instructions

BLACK BOX. Fully assembled, ready-to-use wallmount cabinets. Elite Wallmount Cabinet User s Manual. Customer Support Information

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

AT120A-E; AT140A-E; AT150A,B,D-F; AT160B; AT175A-D,F Transformers

Fiber Splice Panel Rack Mount User Manual

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

Agilent N5470A Series Oscilloscope Rack Mount Kit

Industrial Rack Mount Kit for CompactRIO and CompactDAQ

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC

CR4 Discrete Valve and Manifold Valve Repair or Replacement Procedure

Power Distribution Units AP9560 & AP9561

HP Modular Cooling System 200/100 Options Installation Guide

VALVCON Universal ADC-Series Sealed Lead Acid Back-Up Battery Upgrade Kits. Installation, Maintenance and Operating Instructions

Cisco ASR 1002 Router Overview and Installation

Server Rack Cabinet - 31 in. Deep Enclosure - 12U

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

Installation Guide TB499 Conveyor/Dryer/Stacker Part #: M-3250 Revision Date:

Instructions for Use - Opt-X 1000i Enclosure

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack)

LSI SAS e HBA Temperature and Airflow

POWER STRIPS - INTERNATIONAL

Low-Profile Wallmount Cabinets

Introduction. Pressed Shaft Flowmeter. Flowmeter Service Kits. Disassembly. Idler Shaft Removal

VG54123L/P EARTH LEAKAGE CURRENT DETECTOR

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

1 Match Blind to Window. Sivoia QED Installation Instructions. In-Line Coupled Roller Blind Addendum 1.1

ECO-SERIES REAR BUMPER FORD F150 PART # FD-2962

Installing the Boom Mount ET 350 Monitor (Model ET 350R)

Cisco CRS Carrier Routing System 8-Slot Line Card Chassis Unpacking, Moving, and Securing

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

RF DIRECTIONAL THRULINE POWER SENSOR MODEL 5010

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-LP SERIES. TMI, LLC Managing Environments

Fully assembled, ready-to-use custom cabinets.

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

8300 Series Installation Guidelines

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

USpace Midi Cabinet & Midi Server Cabinet Range.

A-dec 371L or 571L Dental Light on an A-dec 361, 362, or 363 Support Center INSTALLATION GUIDE

SPACESAVER EC-300 A ELECTRICS

N-Series TeraFrame Gen 3 Network Cabinet

ITEM # , WALL LANTERN MODEL #40683, Portfolio is a registered trademark of LF, LLC. All Rights Reserved. Français p.

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES

100 Watt Power Amp 50 Watts x 50 Watts Single Rack Space

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

Sivoia QED R Installation Instructions Please Leave for Occupant

GS-IOB-230VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

Modular Enclosure Solutions RACK IQ - ENTERPRISE & HYPERSCALE DATA CENTER CABINETS

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide

Lighting Control Unit Installation Instructions

Note: If anything is damaged or missing, contact your customer representative immediately.

UPS5000-E (25-75 kva) Series

PMV. P5 Pneumatic Positioner. Product Information

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

Condensation monitor

CM52 Network Protector with Arc Flash Reduction Module

CPS2000 Cabinet Power System

INSTALLATION MANUAL. Contour & Contour LX Pedicure Chairs. Contour. Contour LX Rev B 5/11/18

Railroad Ball Valves Series 5REB3

Transcription:

7 December 2010 Fixed Rack Mount Kit (24-32 ) Installation Procedure Supporting the Brocade VDX 6720-24 and VDX 6720-60 **

Copyright 2010 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, the B-wing symbol, BigIron, DCFM, DCX, Fabric OS, FastIron, IronView, NetIron, SAN Health, ServerIron, TurboIron and Wingspan are registered trademarks, and Brocade Assurance, Brocade NET Health, Brocade One, Extraordinary Networks, MyBrocade, and VCS are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of their respective owners. Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government. Brocade Communications Systems, Incorporated Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 130 Holger Way San Jose, CA 95134 Tel: 1-408-333-8000 Fax: 1-408-333-8101 E-mail: info@brocade.com European Headquarters Brocade Communications Switzerland Sàrl Centre Swissair Tour B - 4ème étage 29, Route de l'aéroport Case Postale 105 CH-1215 Genève 15 Switzerland Tel: +41 22 799 5640 Fax: +41 22 799 5641 E-mail: emea-info@brocade.com Asia-Pacific Headquarters Brocade Communications Systems China HK, Ltd. No. 1 Guanghua Road Chao Yang District Units 2718 and 2818 Beijing 100020, China Tel: +8610 6588 8888 Fax: +8610 6588 9999 E-mail: china-info@brocade.com Asia-Pacific Headquarters Brocade Communications Systems Co., Ltd. (Shenzhen WFOE) Citic Plaza No. 233 Tian He Road North Unit 1308 13th Floor Guangzhou, China Tel: +8620 3891 2000 Fax: +8620 3891 2111 E-mail: china-info@brocade.com Document History Title Publication number Summary of changes Date Fixed Rack Mount Kit (24"-32") Installation Procedure New document. December 2010 2 of 10 Fixed Rack Mount Kit (24"-32") Installation Procedure

Contents This document provides instructions to install a Brocade VDX 6720-24 (1U) or Brocade VDX 6720-60 (2U) switch in a 19-inch (48.3 cm) EIA cabinet using the Fixed Rack Mount Kit (24-32 ). The document is organized as follows: Introduction.................................................... 3 Installation requirements......................................... 3 Tool requirements and parts list................................... 4 Installation procedure........................................... 5 Introduction The supported switches are listed in Table 1. The switch can be installed so that the port side is either flush with the front rails or recessed from the front rails. A recessed position allows a more gradual bend in the fiber optic cables connected to the switch. TABLE 1 Supported switches Switch height Switch model 1U Brocade VDX 6720-24 2U Brocade VDX 6720-60 Installation requirements Allow 15 to 30 minutes to complete this procedure. Note the following requirements to ensure correct installation and operation: Provide space in a 19-inch (48.3 cm) EIA cabinet, as required for the switch type, with a minimum distance of 24 inch (60.96 cm) and a maximum distance of 32 inch (81.28 cm) between the front and back uprights. Verify that the additional weight of the switch does not exceed the cabinet s weight limits. Ensure that an electrical branch circuit with the following characteristics is available: - Required voltage and frequency as indicated in the hardware reference manual (200-230 VAC is always preferred). - Protection by a circuit breaker in accordance with local electrical codes. - Supply circuit, line fusing, and wire size that conform to the electrical rating on the switch nameplate. - Grounded outlet compatible with the power cord and installed by a licensed electrician. Ensure that all equipment installed in the cabinet is grounded through a reliable branch circuit connection. Do not rely on a secondary connection to a branch circuit, such as a power strip. Ensure that the cabinet is mechanically secured to ensure stability. Ensure that the air temperature at the fan inlet is less than 40 o C (104 o F) during switch operation. Ensure that the airflow available at the air vents meets the minimum requirements for the switch. Fixed Rack Mount Kit (24"-32") Installation Procedure 3 of 10

Tool requirements and parts list The following items are required to install a switch using the fixed rack mount kit: Clamps or other means of temporarily supporting the switch in the cabinet Phillips #2 torque screwdriver 1/4-inch slotted blade torque screwdriver ATTENTION Use the screws specified for use with the switch. Longer screws can damage the switch. Ensure that the items listed in Table 2 and illustrated in Figure 1 are included in the kit. TABLE 2 Parts list Description Quantity Brackets, front right and left 2 Brackets, short rear right and left 2 Brackets, long rear right and left 2 Screw, 8-32 x 5/16-in., panhead Phillips 12 Screw, 6-32 x 1/4-in., flathead Phillips 8 Screw, 10-32 x 5/8-in., panhead Phillips 8 Retainer nut, 10-32 8 4 of 10 Fixed Rack Mount Kit (24"-32") Installation Procedure

3 2 3 1 2 1 4 (12x) 5 (8x) 6 (8x) 7 (8x) (8-32 x 5/16 in.) (6-32 x 1/4 in.) (10-32 x 5/8 in.) (10-32) 1 Front brackets, right and left 5 Screw, 6-32 x 1/4-in., flathead Phillips 2 Short rear brackets, right and left 6 Screw, 10-32 x 5/8-in., panhead Phillips 3 Long rear brackets, right and left 7 Retainer nut, 10-32 4 Screw, 8-32 x 5/16-in., panhead Phillips FIGURE 1 Items in the Fixed Rack Mount Kit (24-32 ) Installation procedure ATTENTION The switch must be turned off and disconnected from the fabric during the installation procedure. NOTE Although this document describes how to install both single height (1U) and double height (2U) switches, single illustrations may show either switch type as examples. Complete these tasks to mount the switch: Attaching front brackets Installing the switch in the cabinet Fixed Rack Mount Kit (24"-32") Installation Procedure 5 of 10

! LNK SPD Attaching rear brackets to front brackets Attaching rear brackets to cabinet uprights Attaching front brackets Complete the following steps to attach the front brackets to the switch. 1. Position the right front bracket with the flat side against the right side of the switch (Figure 2). 2. Insert two 8-32 x 5/16-in. screws into the front pair of vertically aligned holes in the bracket and then into the pair of holes on the side of the switch. 3. Insert three more 8-32 x 5/16-in. screws through the holes in the bracket and into the corresponding holes in the switch as shown. 4. Tighten all the 8-32 x 5/16-in. screws to a torque of 15 in-lbs. (17 cm-kgs). 5. Repeat step 1 through step 4 to attach the left front bracket to the left side of the switch. SilkWorm 4100 RIGHT IOIOI #2-0002402-02 REV. B FOXCONN 01/03/2005 1 4 1 Bracket, front right 4 Screw, 8-32 x 5/16-in., panhead Phillips FIGURE 2 Positioning the front bracket Installing the switch in the cabinet Complete the following steps to install the switch in the cabinet. 1. Position the switch in the cabinet, providing temporary support under the switch until the rail kit is secured to the cabinet. 2. Attach the right front bracket to the right front rack upright using two 10-32 x 5/8-in. screws and two retainer nuts as shown in Figure 3. 6 of 10 Fixed Rack Mount Kit (24"-32") Installation Procedure

! LNK 3. Attach the left front bracket to the left front rack upright using two 10-32 x 5/8-in. screws and two retainer nuts as shown in Figure 3. 4. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lbs. (29 cm-kgs). LEFT scale: 1/8" = 1" RIGHT SilkWorm 4100 IOIOI SPD #2-0002402-02 REV. B FOXCONN 01/03/2005 1 7 6 1 Bracket, front right 7 Retainer nut, 10-32 6 Screw, 10-32 x 5/8-in., panhead Phillips FIGURE 3 Positioning the switch in the cabinet Attaching rear brackets to front brackets Complete the following steps to attach the rear brackets to the front brackets. 1. Select the short rear brackets or the long rear brackets depending on the depth of your cabinet. 2. Position the right rear bracket inside the right front bracket. 3. Attach the brackets using four 6-32 x 1/4-in. screws as shown in Figure 4. Figure 5 shows the long brackets attached to the front brackets. 4. Adjust the brackets to cabinet depth and tighten the 6-32 x 1/4-in. screws to a torque of 9 in-lbs. (10 cm-kgs). 5. Repeat step 1 through step 4 to attach the left rear bracket to the left front bracket. Fixed Rack Mount Kit (24"-32") Installation Procedure 7 of 10

5 RIGHT 2 #2-0002402-02 REV. B FOXCONN 01/03/2005 1 1 Bracket, front right 5 Screw, 6-32 x 1/4-in., panhead Phillips 2 Bracket, short rear right FIGURE 4 Switch with the short rear brackets FIGURE 5 Switch with the long rear brackets (attachment similar to short rear brackets) 8 of 10 Fixed Rack Mount Kit (24"-32") Installation Procedure

Attaching rear brackets to cabinet uprights Complete the following steps to attach the rear brackets to the cabinet uprights. 1. Attach the right rear bracket to the right rear cabinet upright using two 10-32 x 5/8-in. screws and two retainer nuts as shown in Figure 6. 2. Attach the left rear bracket to the left rear cabinet upright using two 10-32 x 5/8-in. screws and two retainer nuts. 3. Tighten the 10-32 x 5/8-in. screws to a torque of 25 in-lbs. (29 cm-kgs). 6 RIGHT 2 7 #2-0002402-02 REV. B FOXCONN 01/03/2005 1 1 Bracket, front right 6 Screw, 10-32 x 5/8-in., panhead Phillips 2 Bracket, short rear right 7 Retainer nut, 10-32 FIGURE 6 Attaching the rear bracket to the cabinet upright Fixed Rack Mount Kit (24"-32") Installation Procedure 9 of 10

10 of 10 Fixed Rack Mount Kit (24"-32") Installation Procedure