ABB Automation & Power World: April 18-21, 2011 EPO How 38kV R-MAG Can Be Used in Wind Farm Applications. ABB Inc. April 20, 2011 Slide 1

Similar documents
ABB Automation & Power World: April 18-21, 2011 WPS System Planning. ABB Inc. April 21, 2011 Slide 1

ABB Automation & Power World: April 18-21, 2011 WPO MV outdoor products for smart grid demands. ABB Inc. April 19, 2011 Slide 1

ABB Automation & Power World: April 18-21, 2011 WRE Optimal transformer selection for renewable energy. ABB Inc. April 20, 2011 Slide 1

ABB Wind Power Solution

Implementing Fault Detection Isolation Restoration & Incipient Fault Detection in Distribution Systems

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Static var compensator (SVC) applications for improving transmission system performance

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Type SOQ Negative Sequence Time Overcurrent Relay

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

S C ELECTRIC EUROPE LTD. Excellence Through Innovation. Harnessing the Wind. November 2011 Descriptive Bulletin E

Air-insulated switchgear UniGear type ZS1

Advance 27 ANSI 27 kv switchgear

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Medium Voltage Outdoor Apparatus Portfolio 2009

Transformer Protection

Wessel Bakker Business Line Director ETD BMEA DNV KEMA The Netherlands

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

Advanced Protective Relay Training

Outdoor Padmount Switching Products

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Xiria the smart solution

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

Medium Voltage Metal-Enclosed Switches

Publication No.: PSG

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

ABB Wind Care Service Offering

SWITCHGEAR DIVISION PRODUCT PROFILES

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

EH2741 Communication and Control in Electric Power Systems Lecture 3. Lars Nordström Course map

Xiria the smart solution

Feasibility Study. Shaw Environmental, Inc. 12MW Landfill Gas Generation Interconnection. J.E.D. Solid Waste Management Facility. Holopaw Substation

Metal enclosed capacitor banks: ABBACUS family

Solid Dielectric, Single Phase Recloser

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

Eaton Corporation An Overview Eaton Corporation. All rights reserved.

Shunt reactors Proven history for future success

Industrial Substation Maintenance April $4,250 Abu Dhabi. UAE

Enabling the power of wind. Competence and expertise for wind power customers

Substation Maintenance Training

ABB POWER SYSTEMS CONSULTING

Aerial Operations. Name: Frank Ennist

Medium Voltage Metal-Enclosed Switches

B kv T&D GAS INSULATED SWITCHGEAR

EL PASO ELECTRIC COMPANY SHORT CIRCUIT ANALYSIS FOR XXX S PROPOSED GENERATION INTERCONNECTION

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Solid Dielectric, Single Phase Reclosers

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

IEEE-PES Chicago Chapter Presentation November 11, Smart Grid. Mike Born. Principal Engineer, Capacity Planning

Journal of American Science 2015;11(11) Integration of wind Power Plant on Electrical grid based on PSS/E

Pretest Module 29 High Voltage Unit 1

In any of the 5 star hotels. The exact venue will be informed once finalized.

Interruption Technology of Breakers for High-voltage Direct Current

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

Grid code Compliance and Renewable Energy Projects. Mick Barlow, Business Development Director, S&C Electric, United Kingdom

Substation Concepts for the Future

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

Cobra-S. Catalog Cobra-S

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Dynamic Reactive Power Control for Wind Power Plants

Study of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank

Customer presentation, PG Service, BU Motors and Generators ABB LEAP Stator Winding-Condition & Lifetime assessment

Medium voltage vacuum circuit breaker. E-VAC series

100 MW Wind Generation Project

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

Microgrid solutions Delivering resilient power anywhere at any time

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Independent Testing Laboratory for High Voltage Equipment

CUSTOMER / ACCOUNT INFORMATION Electric Utility Customer Information (As shown on utility bill)

Medium Voltage Drives. ABB Value Provider Program Partnership for growth and profit

David Park, EPMV ABB South Africa / Africa Channel Partner event, 2016 ABB Africa Channel Partner event Medium Voltage Apparatus

Totally Integrated Power. A reliable all-rounder. Gas-insulated medium-voltage switchgear 8DJH 36.

Product Group Brochure. PS Range Capacitor Vacuum Switches

ABB. Replacement Components

AFRA NOJAN Co. General Trading Catalogue POWER OIL, GAS & PETROCHEMICAL

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

PJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008

Utility Distribution Planning 101

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Burns & McDonnell ISU Senior Design Project 2010/2011

Power System Solutions (PSS)

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

Prüffeld der Schaltwerke

ABB Microgrids and Energy Storage. Nathan Adams, Director, Technology and Business Development

Transcription:

ABB Automation & Power World: April 18-21, 2011 EPO-148-1 How 38kV R-MAG Can Be Used in Wind Farm Applications April 20, 2011 Slide 1

WCS-120-1 R-MAG in Wind Farms Speaker name: Speaker title: Company name: Location: Cleber Angelo Product Manager ABB PPMV Lake Mary, FL April 20, 2011 Slide 2

Your safety is important to us Please be aware of these emergency procedures In the event of an emergency please dial ext. 55555 from any house phone. Do not dial 9-1-1. In the event of an alarm, please proceed carefully to the nearest exit. Emergency exits are clearly marked throughout the hotel and convention center. Use the stairwells to evacuate the building and do not attempt to use the elevators. Hotel associates will be located throughout the public space to assist in directing guests toward the closest exit. Any guest requiring assistance during an evacuation should dial 0 from any house phone and notify the operator of their location. Do not re-enter the building until advised by hotel personnel or an all clear announcement is made. April 20, 2011 Slide 3

Your safety is important to us Convention Center exits in case of an emergency Know your surroundings: Identify the meeting room your workshop is being held in Locate the nearest exit April 20, 2011 Slide 4

Wind installations What Happened in 2010? April 20, 2011 Slide 5

Wind target is 20% by 2030 April 20, 2011 Slide 6

Wind challenges April 20, 2011 Slide 7

The Wind Market - Size & Cost Structure Total US wind power market in 2009 is estimated to be $2.5 billion* Collector System & Interconnect 12.6% Legal and Financial 2.7% Development 1.8% Substation 5.4% 14.4% Turbine Erection and Foundations 63.1% Turbine & towers April 20, 2011 Slide 8

ABB in wind energy April 20, 2011 Slide 9

ABB products in the collector circuit and substation April 20, 2011 Slide 10

38kV R-MAG in Wind Farm Applications Wind Farm Typical One-Line April 20, 2011 Slide 11

38kV R-MAG in Wind Farm Applications Where can the R-MAG be utilized? Wind farm collector Capacitor switching Reactor switching April 20, 2011 Slide 12

38kV R-MAG in Wind Farm Applications Where can the R-MAG be utilized? Wind farm collector Critical element in power flow Low frequency of operation April 20, 2011 Slide 13

38kV R-MAG in Wind Farm Applications Where can the R-MAG be utilized? Capacitor bank switching Higher frequency of operation Varying load and generation results in swings in reactive power component Underground cables contribute to circuit capacitance Low current 36kV, 10MVAR 150A Transient voltages on switching April 20, 2011 Slide 14

38kV R-MAG in Wind Farm Applications Where can the R-MAG be utilized? Capacitor bank switching Vacuum interrupters using Copper/Chromium composite material to minimize current chopping and mitigate it s effects April 20, 2011 Slide 15

38kV R-MAG in Wind Farm Applications Where can the R-MAG be utilized? Reactor switching Higher frequency of operation Low current Transient voltages on switching Highly dependent on system parameters Analysis should be performed to determine reactance of circuit

38kV R-MAG in Wind Farm Applications Key Challenges Reliability Tight margins on wind farm economics Uptime is at a premium Maintenance Remote and harsh environments lead to costly maintenance and repair costs

Key Challenges Solution: ABB 38kV R-MAG Rated for 5 times the mechanical operations required by the standard, reducing maintenance and down time Reduced mechanical failure with only one moving part in the magnetic actuator Less maintenance lowers risk by reducing exposure to live parts and stored energy devices Service/Support ABB expanded customer service organization focuses on customer

38kV R-MAG in Wind Farm Applications Reliability Magnetic actuator Rated for 50,000 operations on 38kV breakers Rated for 100,000 on 15/27kV breakers ABB Inc April 20, 2011 Slide 19

38kV R-MAG in Wind Farm Applications Reliability Vacuum Interrupter Assembly ABB interrupters are rated for up to 30,000 mechanical or load operations ABB Inc April 20, 2011 Slide 20

38kV R-MAG in Wind Farm Applications Flexibility Actuator control board compatible with all forms of overcurrent, reclosing and control functions Control Voltages from 24V to 250V Built in trip & close coil features Built in breaker status indication Coil protection

38kV R-MAG in Wind Farm Applications Ease of maintenance No maintenance required for the magnetic actuator Plug-and-play capability of the actuator control board No disassembly as common with spring mechanism

38kV R-MAG in Wind Farm Applications Embedded pole design Proven technology used in switchgear breakers High field performance due to reduced contamination build up on vacuum interrupters Only one vacuum interrupter per pole.

Reminders Automation & Power World 2011 Please be sure to complete the workshop evaluation Professional Development Hours (PDHs) and Continuing Education Credits (CEUs): You will receive a link via e-mail to print certificates for all the workshops you have attended during Automation & Power World 2011. BE SURE YOU HAVE YOUR BADGE SCANNED for each workshop you attend. If you do not have your badge scanned you will not be able to obtain PDHs or CEUs. April 20, 2011 Slide 24

ABB Group April 20, 2011 Slide 25