M670/M680BD MAGNALOCK SERIES Installation Instructions

SHEAR ALIGNING MAGNALOCK MODEL SAM2-24 INSTALLATION AND OPERATING INSTRUCTIONS

RECESSED MAGNALOCK MODEL M34R SERIES INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION DESCRIPTION

AccuPower AQU126B Installation Instructions

INSTALLATION AND OPERATING INSTRUCTIONS For Model M38 and M68 Magnalocks (Versions L, S and LS with D and T Options)

DynaLock 705 Emmett Street Bristol, CT Phone:(860) Fax:(860)

V2M1200/1290 Series Maglock Installation Instructions

AccuPower AQU128B Installation Instructions

FLEX MOUNT KIT INSTALLATION INSTRUCTIONS FMK-SW (Swing Gates) & FMK-SL (Sliding Gates)

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

HANDLING MECHANICAL INSTALLATION

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

E-941SA-300RQ. Manual. 300-lb Single-Door Electromagnetic Lock with Reversible Magnet

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

Accessories 286 SDC SECURITY DOOR CONTROLS

5600 Series Power Operator Installation and Instruction Manual

M400 Series Double Locks. Features

MODEL 600S 600 POUND SINGLE MAGNETIC LOCK SPECIFICATIONS

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

With LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA lb.

MODEL 3002xTJ32 ELECTROMAGNETIC LOCK INSTALLATION INSTRUCTIONS

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

2-row and All-row systems included.

SHEAR ALIGNING MAGNALOCK MODEL SAM INSTALLATION AND OPERATING INSTRUCTIONS

Installation Instructions

MODEL 1200S MAGNETIC LOCK

MODEL 1200S MAGNETIC LOCK

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

CV41. Vehicle Mounting Kit. Reference Guide

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Installation and Service Manual

ASSEMBLING THE 15 INCH FLUSH MOUNT TOUCH SCREEN DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN

Toyota Prius Interior Light Upgrade

Pre-Installation Instructions

lkm7001 key override module Installation Instructions Converting The LKM7000 to The LKM7003

* * M400 Series Double Locks. Double Electromagnetic Locks: M422, M452, M492. Installation Instructions. Mounting Bracket (2)

LGT-312L E-Z-Go TXT Light Bar Bumper Kit Installation Instructions

PD10-M-RIM INSTALLATION INSTRUCTIONS. The PD10-M-RIM is a storefront grade 1 exit device equipped with motor drive latch retraction.

INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S

Installation Instructions - D-Series Warming Cabinet Instruction Door for Hinge UseReversal (Glass and Stainless Steel Doors)

VLP-UL-M-KIT INSTALLATION INSTRUCTIONS

INSTALLATION 8310/8320

LGT-306L / LB Club Car Precedent LED Light Bar Bumper Kit Installation Instructions

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Scion xb Interior Light Upgrade Part Number: Accessory Code: YI1

Installation Instructions for ROFU Key Hole Mount Magnetic Locks

LEVELe ELEVATOR INTERIORS WITH LIGHTPLANE INSTALLATION INSTRUCTIONS. STANDARD LEVELe COMPONENTS CEILING COMPONENTS LIGHTPLANE COMPONENTS TOOLS NEEDED

2965 Magnetic Shear Lock Installation Instructions

I N S T A L L A T I O N G U I D E. Ram 1500 Crew Cab A Ram 2500/3500 Crew Cab A

TOYOTA im INTERIOR LIGHT KIT Preparation

Alliance Towel Dispensing System. Operation Manual

05 09 Mustang Squirter Nozzle Relocation Kit CDC #112050

TOYOTA RAV4/HV INTERIOR LIGHT KIT Preparation

Installation and Care Instructions

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Electronic Entry Device Installation Instructions

TOYOTA YARIS HATCHBACK INTERIOR LIGHT UPGRADE Preparation

INSTALLATION EML375. Pre-Installation Instructions. Electromagnetic Locks

U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M

1-3/4" MOUNTING INSTRUCTIONS: 1150 SERIES SURFACE MOUNTED 1500 LB. ELECTROMAGNETIC LOCK

PFadvantage Metalfor Araus 1360

PFadvantage MF 6850/6855; Ideal 9080/9090

05 09 Mustang Squirter Nozzle Relocation Kit CDC #112050

TOYOTA AVALON INTERIOR LIGHT UPGRADE Section TOYOTA II - Installation AVALON Procedures

Part Name/Description Part Number Quantity Instruction Kit Metalfor Flow Sensor

Plasma Display Electric Ceiling Lifts

Ram 1500 Crew Cab A Ram 2500/3500 Crew Cab A

Soap/Sanitizer Dispensers

Instructions for 2-row monitoring only

Automotive: Lightbars

Instructions for 2-row monitoring only

Down and Out Motor Mount Assembly & Installation Directions

LiteDOT Installation Document

VOLKSWAGEN AMAROK 3 PIECE HARD TONNEAU COVER INSTALLATION INSTRUCTIONS

Installation Instructions for Slide Mount Magnetic Locks

Soap/Sanitizer Dispensers

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK

Standard Plastic Template P/N: (3-0) P/N: (4-0)

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

I N S T A L L A T I O N G U I D E

POLY TIP-DOWN WINDSHIELD KIT

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE ELECTROMAGNETIC LOCK.

INSTALLATION MANUAL FOR PILOT WORKSTATION

Excel Series Value Engineered Access Hardware

SPEEDKEY KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 9. GEM e2, e4, e6, el XD

General Information. Notations and Conventions. Compatibility Check. Kit Description. Call-Outs. Part Lists Great Plains Manufacturing, Inc.

Auto-Lift Operating System

INSTALLATION INSTRUCTIONS

cel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches

INSTALLATION INSTRUCTIONS

Included in Hardware Kit. Rear Corners 2-Door. Jeep JK Trail Armor. Set Part #14009 Rev STEP 1 - PRIOR TO INSTALLATION

3-5 Hours Professional installation recommended

Cybex Arc Trainer Owner s & Service Manual. 7 - Service

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Transcription:

Securitron Magnalock Corp. www.securitron.com Tel 800.624.5625 techsupport@securitron.com M680BDCX MAGNALOCK SERIES Installation Instructions Table of Contents Specifications 2 Configuring Options 3 Installation Guide 6 Wiring Diagram 14 Error Codes 16 Scan this QR Code for a guided installation video. Alternatively Quick Clips are available in each section. Package Contents Strike Plate M680BDCX Sex Bolt Template Mounting Bracket Mounting Hardware Note: Endcaps provided for Model 680 only. Mounting Hardware (2) x Bracket Spacer (2) x 1/4-20 Blind Nut (1) x Blind Nut Installation Tool (2) x 1/4-20 x 1 Phillips Pan Head (2) x 1/4 x 1-1/4 Roll Pin (1) x 5/16-18 x 1-3/4 Flat Head Socket (3) x Neoprene Washer (4) x #12 x 1-1/2 Type A Phillips Pan Head (4) x #14 x 3 Type A Phillips Pan Head Copyright, 2012, all rights reserved Page 1 Rev. D, 07/12

Recommended Tools Masking Tape #0, #1 and #2 Phillips Screwdrivers Hammer Measuring Device 1/2 Open End or Crescent Wrench Pencil/Pen Center Punch Wire Strippers/Cutter Multimeter Fish Tape or Lead Wire 3/16 Hex (Allen) Wrench Drill bits: 3/16, 7/32 (wood frames only), 3/8, 1/2, 5/8 M680BDCX Specifications Mechanical Electrical Environmental (Recommended) Physical Size: Height: 2-1/2 [66mm] Depth: 2-1/2 [66mm] Length: 11-1/2 [292mm] Shipped Weight: Weight: 13 lbs Holding Force (Maximum) 1,100 Lbs. [500kg] Input Voltage 12/24 VDC Current Maglock 12VDC/550mA (±10%) 24VDC/300mA (±10%) Optional Camera 12VDC/200mA (±10%) 24VDC/80mA (±10%) Optional PIR 12VDC/25mA (±10%) 24VDC/10mA (±10%) Tamper Switch Rating Voltage 30VDC (Maximum) Current 1 Amp DPS Rating (M680 only) Voltage 30VDC (Maximum) Current 125mA BondSTAT Switch Rating Voltage 30VDC (Maximum) Current 1 Amp Request to Exit Switch Rating Voltage 30VDC (Maximum) Current 1 Amp Operating Temperature 32ºF to 110ºF [0ºC to 43ºC] Humidity 10% to 90% RH Camera Specifications Color Version: Horizontal Resolution: 520 TV Line Video output: 1Vp-p, 75Ω Min illumination: 1.5 LUX Black and White Version: Horizontal Resolution: 420 TV Line Video output: 1Vp-p, 75Ω Min illumination: 0.1 LUX Magnalock Preparation and Installation Pre-Installation Survey Before installing the Magnalock, the mounting location should be determined and assessed for the following: Physical strength of the frame should be strong enough to meet or exceed the holding force of the Magnalock. Frame and vicinity should offer protection for the wiring to prevent vandalism Door should be inspected for any obstacles that may interfere when mounting the strike plate The Magnalock M670/M680 comes with factory default mounting for use with an outswing door. Please contact Securitron for available brackets for other installation configurations. Page 2 Rev. D, 07/12

Magnalock Preparation 1. Using a Phillips screwdriver, remove the two (2) screws securing the cover as shown. Remove the cover to provide access to the circuit board on the back of the magnet. The screws should be saved to re-attach the cover later. 2. Component Locations Quick Clip 1: SW2 BDCX Configuration Page 3 Rev. D, 07/12

Component Label Component Name Selection Position JP1 Jumper 1: Tamper Switch Mode Select A 3-pin jumper that controls the output setting for Tamper Switch SW1 at Terminal Block J1. (NC) Normally Closed Circuit Closed when Cover Closed (default setting) (NO) Normally Open Circuit Open when Cover Closed JP2 Jumper 2: Request to Exit Mode Select A 3-pin jumper that controls the output setting for the Request to Exit (REX) signal in Terminal Block J8 Position 3 & 4. (NO) Normally Open Circuit Open, Circuit closes when REX active (default setting) (NC) Normally Closed Circuit Closed, Circuit opens when REX active JP3 Jumper 3: Door Position Mode Select A 3-pin jumper that controls the output setting for the Door Position Switch (DPS) in Terminal Block J8 Position 1 & 2. (NC) Normally Closed Circuit Closed when Door is Closed (default setting) (NO) Normally Open Circuit Open when Door is Closed JP4 Jumper 4: LED Enable A 2-pin jumper that enables the LED. LED ENABLED (default setting) LED DISABLED (jumper removed) JP5 Jumper 5: LED Color Select A 2-pin jumper that controls the color of the LED output. Output options are red or green. SECURE = RED LED (default setting) SECURE = GREEN LED (jumper removed) Page 4 Rev. D, 07/12

SW2 DIP Switch: PIR Enable and Delay Selection ENABLE PIR Switch 5 ON 5 second delay Switch 3 OFF (default) 10 second delay Switch 3 ON DIP Switch: DISABLE Delay Timer Switch 4 OFF (default) Auto Relock Timer Enable and Delay ENABLE Delay Timer Switch 4 ON Selection The Auto Relock Delay 5 second delay Switch1 OFF, Switch2 OFF Timer is disabled by default. The delay can 10 second delay Switch1 OFF, Switch2 ON be enabled by setting Switch 4 to ON, and then selecting a time 20 second delay Switch1 ON, Switch2 OFF delay with Switch 1 and Switch 2. 30 second delay Switch1 ON, Switch2 ON 3. J1 Terminal Block 1 Tamper Switch J5 Terminal Block 5 Input Power J6 Terminal Block 6 BondSTAT J8 Terminal Block 8 Door Position Switch BNC Cable BNC Connector for Camera Signal Document Configuration Settings A 2-wire terminal block providing a SPDT contact that changes state as determined by JP1 when the cover is sensed to be removed by SW1. A 3-wire terminal block providing connection to the power supply. Position 1 is a constant (+) for camera and PIR. Position 2 is (+) for the lock power, position 3 is (-). A 3-wire terminal block providing a SPDT 1-Form C contact that changes state when the BondSTAT bond is interrupted. A 6 wire terminal block providing: (1-2) SPST contact determined by Jumper 3 based on door position switch. (3-4) SPST contact state change is determined by Jumper 2 based on REX activation. (5-6) 2 position dry contact, closure disables PIR. The included BNC cable can be routed through either side of the maglock housing for connection to surveillance system The Board Settings are now complete. Copy your settings onto the adhesive-backed Circuit Board Settings label enclosed with the mounting hardware packet. M670/M680 Settings www.securitron.com Jumper 4 (JP4) LED Enable ENABLED DISABLED Jumper 5 (JP5) LED SECURE Color RED GREEN *Jumper 1 (JP1)Tamper Select Mode NC 1-2 NO 2-3 *Jumper 2 (JP2) Request to Exit Mode NO 1-2 NC 2-3 *Jumper 3 (JP3) Door Position Mode NC 1-2 NO 2-3 *(SW2) Auto Relock Delay ENABLED DISABLED *Delay (in seconds) 0 5 10 20 30 *available on select models 1-800-MAGLOCK Important! Complete the label and affix to the inside cover of your Magnalock This information will be needed if the lock needs to be serviced, replaced or inspected. Page 5 Rev. D, 07/12

Magnalock Installation 1. Remove three (3) screws securing lock to mounting bracket and slide the bracket from the top of the lock chassis. 2. Pinch and insert spacers flush into the dovetail slots of the lock-mounting bracket. 3. Mark Mounting Holes: Use masking tape to protect the door and frame surfaces during marking and drilling. Place the lock bracket on the secure side of the door against the frame stop toward the side of the door that does not have hinges. Close the door and adjust the bracket so that the spacers rest against the door. Mark the frame through the two (2) oblong bracket mounting holes. Note: Maintain 7/8 minimum clearance from the frame Quick Clip 2: Mounting the Bracket 4. Mark Wire Feed-Through Holes: Mark the frame for wire feed-through hole at the end closest to where you will access the wire run. These holes should be toward the rear edge of the mounting bracket and be adjacent to the end of the bracket as shown. Remove mounting bracket from frame when drilling holes. Use either location for Wire Feed-Through Holes Page 6 Rev. D, 07/12

5. Metal Door Frame - Drill Mounting Holes: Note: If installing on a wood door frame, go to Step 7. Drill two (2) 3/8 diameter holes at bracket-mounting hole marks. 3/8 diameter (METAL) 3/8 diameter (METAL) Note: Do not oversize the hole. Use a step bit or pilot hole first to ensure a snug fit for the blind nuts. 6. Blind Nut Installation: Use the tool provided to install blind nuts into each 3/8 diameter hole. Hold the collapsing nut with a 1/2 box end wrench. Maintain pressure on the mounting surface, while using a 3/16 hex wrench to tighten the cap screw and collapse the blind nut. Go to Step 8. Why Use Blind Nuts? Quick Clip 3: Blind nuts provide a highly secure and tamper resistant system for mounting and are the mounting hardware provided for this unit. Only use approved included hardware for mounting. Blind Nut Installation Page 7 Rev. D, 07/12

7. Wood Door Frame Drill Mounting Holes: Drill two (2) 3/16 diameter holes at bracket-mounting hole marks. Drill 1 ¼ deep. 3/16 diameter (WOOD) 3/16 diameter (WOOD) 8. Drill Wire Access Holes Drill wire access holes as needed on one (1) or both sides of the bracket location. 1/2 diameter is recommended for wire access. 5/8 diameter is recommend for camera wiring. 9. Install Bracket: Use a Phillips screwdriver to temporarily install the bracket with spacers against the closed door. Metal Frames: Use two (2) 1/4-20 X 1 Phillips Pan Head Screws and apply included thread lock to screw threads Wood Frames: Use two (2) #12 X 1-1/2 Type A, Phillips Pan Head Screws. Page 8 Rev. D, 07/12

Strike Installation 1. Close the door and place the template between the bracket spacers. Mark the strike plate hole locations. Bracket spacers can now be removed from the bracket. Quick Clip 4: Bracket Spacers Strike Installation 2. From INSIDE the door: Drill one (1) 3/8 diameter hole for the sex bolt through the door at the strike mounting center mark. Drill two (2) 3/8 diameter x 1 deep holes at each side mark for the strike alignment roll pins. Do not drill through the door. Quick Clip 5: Door Drilling 3. From OUTSIDE the door: For a Hollow Metal Door: Drill out the 3/8 diameter strike mounting hole to 1/2 diameter in the outer wall only. For a Solid Wood Door: Drill out 3/8 diameter strike mounting hole to 1/2 diameter; drill completely through. Page 9 Rev. D, 07/12

4. Install Roll Pins into Strike Plate: Remove the two (2) roll pins from the hardware packet. Insert a roll pin into each of the holes in back of strike. Gently tap into place using a hammer. 5. Secure Strike Plate to the Door Apply the included threadlock compound to the 5/16-18 X 1-3/4 flat head socket screw. Pass the 5/16-18 X 1-3/4 flat head socket screw through the strike plate, two (2) neoprene washers, door and into the sexbolt as illustrated. Use a 3/16 hex wrench to tighten the screw into the sex bolt. (While tightening, use a hammer to gently tap the head of the sex bolt until the head sits flush with the door). Do NOT over-tighten the assembly, the neoprene washers should not be compressed. Allow the strike to rock on the neoprene washers for proper function and optimum holding force. Quick Clip 6: Sex Bolt Mounting Strike Plate Strike (2) Neoprene Washers 5/16-18 X 1-3/4 Flat Head Socket Page 10 Rev. D, 07/12

Adjustments: 1. Assemble Lock to the Bracket and Adjust: Loosen the two screws securing the mounting bracket to the door frame so that the bracket can move. Slide the lock onto the mounting bracket and test fit against the strike plate with the door closed. Slide the lock so that the entire face makes contact with the strike plate. Mark back edge of mounting bracket at each end and remove the lock from the bracket. Quick Clip 7: Adjustment 2. Ensure that the mounting bracket aligns with the marks and tighten the mounting screws. Page 11 Rev. D, 07/12

3. Drill Frame for Anchor Screws: Using the mounting bracket as a template, drill the four remaining holes in the frame for the anchor screws. Metal Frames: Drill 3/16 diameter holes. Wood Frames: Drill 7/32 diameter holes. 4. Install Anchor Screws: Using a Phillips screwdriver, install the four (4) anchor screws. Metal Frames: Use #12 X 1-1/2 Type A, Phillips Pan Head Screws. Wood Frames: Use #14 X 3 Type A, Pan Head Screws. Page 12 Rev. D, 07/12

Final Installation: 1. Insert the top of the Magnalock chassis at the end of the mounting bracket. Slide the lock chassis to the center of the bracket. The edge of the lock chassis must be flush with the end of the mounting bracket when centered (see inset). Quick Clip 8: Final Installation 2. Using a Phillips screwdriver, install the three (3) 6-32 X 3/4 Phillips pan head screws to secure the lock chassis to the mounting bracket. Page 13 Rev. D, 07/12

Final Wiring 1. Pull wires/cables through the wire feed-through hole(s) that are drilled in the frame. A small screwdriver has been included to help make connections to the terminal blocks as required. The end user and installer are liable for Fire and Building code compliance. 2. The following diagram shows a basic wiring configuration for the Magnalock. M680BDCX 3. Motion Detector models: Enable the motion detector by locating DIP Switch SW2, and setting Switch 5 to ON. REX timer is set with Switch 3. OFF= 5 seconds, ON= 10 seconds Camera Models: Connect the camera to your security system using the included BNC cable. Page 14 Rev. D, 07/12

4. After installation and wiring have been completed, re-install the lock cover through the lock chassis using the two (2) phillips screws removed in the first step. Front View 5. Adjusting the field of the infrared motion detector. The infrared motion detector can be easily adjusted after installation to cover the desired approach area. Rotate the black reflector as shown to adjust from a narrow to a wide coverage area. MAGNALOCK MAINTENANCE Visual Inspection Check the rubber washers for elasticity and proper pivoting. Tighten as required. Check for build-up of debris on the Magnalock and strike armature. Check for rust on the Magnalock and strike plate armature. Clean as required. Page 15 Rev. D, 07/12

Cleaning Methods Apply rubbing alcohol onto a clean cloth and thoroughly wipe down the Magnalock and strike plate armature. Cleaning once a year is recommended. Clean every three to six months where rusting occurs. Use a plastic dishwashing scrub pad to aid in the removal of rust. DO NOT USE PETROLEUM BASED PRODUCTS FOR CLEANING DO NOT USE STEEL WOOL BASED SCRUB PAD OR SANDPAPER Troubleshooting Guide: POSSIBLE ISSUES No power or low power Reduced Holding Force TROUBLESHOOTING TIPS Confirm voltage and current at Magnalock to spec (see page 2) Check that the DC Power Source is Full Wave Rectified (Half wave Rectified or AC power is unacceptable) Check strike plate position and orientation Clean surfaces and check for obstructions LED Error Codes: Note LED Jumper J4 must be installed (LED ENABLED) for error codes to be visible CODE STATE SOLUTION SECURE selected color, on continuously NON-SECURE selected color, on continuously RED/GREEN flash continuous 3 Fast Flashes of SECURE color every 5 seconds Single Flash Amber every 5 seconds Double Flash Amber every 5 seconds Normal Operation with Door Closed Normal Operation with Door Open System working normally, SECURE selected color can be selected with Jumper JP5. See page 4. System working normally Processor Error Check all connections, if error persists replace unit Magnet Voltage has dropped below 85% Bond Error Left Side Bond Error Right Side Check voltage and current at Magnalock connections. Check DC Power Source is Full Wave Rectified. Check strike plate position and orientation. Clean surfaces and check for obstructions. Check strike plate position and orientation. Clean surfaces and check for obstructions. Off LED disabled Check that LED is enabled with a Jumper at JP4. Check voltage and current at J5 Problems with Installation? Call Securitron: 1-800-MAGLOCK For warranty information: visit www.securitron.com/en/site/securitron/about/magnacare-warranty/ Page 16 Rev. D, 07/12