Fiber Optic Illuminator. Model 21AC Model 21DC

Similar documents
Operation Manual. Fiber Optic Illuminator FOI-150-UL FOI-150-REM-UL

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

CANARY AUDIO. Vacuum Tube Preamplifier CA-800 OWNER S MANUAL. Handcrafted in California MADE IN USA

CCTV Rack Mount Power Supplies

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

CCTV Rack Mount Power Supplies

CANARY AUDIO CA-400. Vacuum Tube MM/MC Phono Preamplifier OWNER S MANUAL. Handcrafted in California MADE IN USA

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

Rack Mount Power Supplies

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

FD Conveyor for FD 260 Tabber

HLS Watt Halogen Illuminator Service Manual

Model 1672, 1673 Triple Output Power Supply

Model G14SD Vapor Management System

Cooling Module. Instruction Manual

i3000s/i2000 Flex AC Current Probe

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

Switching DC Power Supply

User s Manual Power Supply IM E. 5th Edition

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to


SLA Battery Capacity Analyzer

DC POWER SUPPLY ALIMENTATION C.C.

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

DC CCTV Power Supplies Installation Guide

Model 1693, 1694 Switching DC Power Supply

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

1 AMP CURRENT SOURCE

WF-5110R True Sine Wave Inverter

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

OPERATION and MAINTENANCE INSTRUCTION MANUAL

MicroPod Sub User manual / Bedienungsanleitung / Manual del Usario

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

EPS/ELA-Series User Manual EPS/ELA 250W

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

DH-2000 Deuterium-Halogen Light Source Installation and Operation Manual

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Test Oven. Series 3600 and 3700

ALU-29CF Portable Light NSN:

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Hawk Enterprises of Elkhart THE BRUTE Owner s Manual

AP250 Automated Projector

DSP led gaming monitor USER MANUAL

Triple Output High Resolution Power Supply. User Manual

WF-5110R True Sine Wave Inverter

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

PY-11 Voltage & Continuity Tester

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Cordless Make Up Mirror WITH ILLUMINATED 1X AND 10X MAGNIFICATION PLUS NIGHT LIGHT

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Users Manual. Phase Rotation Indicator

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Model MC4 MEDIA CONTROL by OWI

- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.

P. D. Q. Automatic Burnout Furnaces. 115 and 230-volt Models OPERATOR S MANUAL

OCTA FLUORESCENT 7 SOCKET FIXTURE

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Xenon Fiberoptic Lightsource

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

Twelve Unit Rapid Charger

WF-5100 Series True Sine Wave Inverters

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

Swing Arm Magnifying Lamp

USERS MANUAL MCD REMOTE OPERATOR

Triple Output Power Supply

OWNERS MANUAL IMPORTANT: READ OWNERS MANUAL CAREFULLY MODEL # SQUARE CAT XT OSCILLATING FLOOR MACHINE

HyperFlex 12G.

For technical questions and replacement parts, please call

Model 809 Diaphragm Gauge Controller

Mania EF1 user manual

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

Measurements are expressed in millimeters.

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

S150,S300 Series Pure Sine Wave Inverter User s Manual

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

F L B Metal Halide Light Generator for Fiber Optic Lighting Systems

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

Transcription:

Operation Manual Fiber Optic Illuminator Model 21AC Model 21DC

Warning This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions to the literature accompanying the appliance. Important This equipment has been tested and found to comply with IEC 61010-1 and UL3101-1 as an Overvoltage Category II: (local level, small appliances, portable equipment, etc. with smaller transient overvoltages than Overvoltage Category III.) Pollution II. Caution You are cautioned that any change or modifications not expressly approved in this manual could void your authority to operate this equipment. Precautions On Power Sources Before operating the product, check that the operating voltage is identical to your local power supply. See specific descriptions for operating voltages. This unit is not disconnected from the AC power source as long as it is connected to the wall outlet, even if the unit itself has been turned off. To disconnect the AC power cord, grasp the plug itself; never pull the cord. One blade of the plug is wider than the other for the purpose of safety and will fit into the wall outlet only one way. If you are unable to fully insert the plug into the outlet, contact Techniquip. AC power cord must be replaced with IEC compatible cord. On Operation Before connecting to fiber optic components, be sure that all power connections are secure. On Cleaning Clean the cabinet, panel and controls with a soft cloth slightly moistened with a mild detergent solution. Do not use any type of abrasive pad, scouring powder or solvent such as alcohol or benzine.

If you have any questions or problems concerning your product, please consult Techniquip. For Customers in Canada CAUTION TO PREVENT ELECTRIC SHOCK, DO NOT USE THIS POLARIZED AC PLUG WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE. Owners Record The model and serial number are located on the bottom of the unit. Record the serial number in the space provided below. Refer to them whenever you call upon your Techniquip dealer regarding this product. Fiber Optic Illuminator Model 21AC Model Number Serial Number

Contents MODEL 21AC Getting Started 1 Unpacking 1 Hookup Overview 1 Description 1 Illuminator Descriptions (Front Panel) 1 Illuminator Descriptions (Rear Panel) 2 Lamp Replacement 3 Specifications 4 Model Codes 5 i ii

Getting Started Description Unpacking - MODEL 21AC Check that you received all items on the packing list. Hookup Overview The Model 21AC Illuminator allows you to connect and control a variety of fiber optic components. To learn the locations and names of important connections see Illuminator Descriptions beginning on this page below. Illuminator Descriptions (Rear Panel) 1. T-slot mounting for #1/4-20 or M6 hexhead fastener; both sides (#10-32 or M5 barnut optional) 2. IEC inlet with line filtering (power cable input) 3. Operating voltage label: Before You Get Started Turn off the power to the Model 21AC Illuminator before making any connections. Do not connect the AC power cord to the local power supply until the connections are completed to the Model 21AC Illuminator. Be sure to make connections firmly. Be sure that the Model 21AC operating voltage matches the local power supply. Illuminator Descriptions (Front Panel) 1. Variable intensity controller (0 to 100%). 2. On/Off rocker switch. 3. Front panel fasteners (2X) 4. Lamp module. 5. V-port with T-handle retainer Illuminator Descriptions (Rear Panel) 1 2

Lamp Replacement Specifications Lamp Replacement Instructions 1. To replace the lamp, shut off the power and remove the power cord from the AC outlet. To disconnect the AC power cord, grasp the plug itself; never pull the cord. 2. Located on the lamp access panel, manually loosen the front panel fasteners. 3. With front panel released, remove the lamp module from the unit. Use caution; fan blades are accessible while lamp module is removed. 4. Allow sufficient time for the unit to cool. CAUTION: Lamp and surfaces may be extremely hot! 5. Remove the lamp from the socket and place in a safe area. 6. Insert the replacement lamp into the socket; pressing firmly to ensure that pins are fully seated. 7. Close the access panel. 8. Secure the lamp access panel by manually tightening the front panel fasteners. Specifications Environmental Intended for indoor use only Operating temperature: -4 to 104 F (-20 to 40 C) Humidity range: 0 to 80%; non-condensing Pollution degree: 2 Electrical (all units) Operating frequency: 60 Hz (110 VAC) or 50 Hz (220VAC) Power consumption: 180 watts at full light intensity Power requirements: 110 VAC; 60 Hz 220 VAC; 50 Hz Lamp adjustment range: 0 to 100% Color temperature: 3200K at maximum intensity (assuming standard EKE lamp) Lamp life: 250 to 10,000 hours Physical Mass (approx.): Replacement Parts 4.5lbs. (2.04kgs) Lamp Replacement Lamp Type: 150W EKE, 3250K (#20094145)* 150W EKE-HC, 4200K (#20094142) 150W EJV, 3400K (20094143) * Standard lamp type provided with illuminator. Fuse Replacement Fuse Type: 3.15A 250V, 5x20mm (#02610014) On Safety Should any solid object or liquid fall into the assembly while access panel is open, have it checked by qualified personnel before operating. 3 4

Model Codes Model 21AC Matrix 21AC 1 K 1 00 X -XXX Modifications Material Type Lamp Type Lamp Module (nosepiece) Cord Set Input Voltage Model Fiber Optic Illuminator Model 21DC Model: 21AC Model 21AC Input Voltage: 1 110 VAC; 60 Hz 2 220 VAC; 50 Hz Cord Set: A Euro/Shuko H Israel C Australia I Italy D United Kingdom K North America E Denmark L Switzerland F France/Belgium R Russia G India X No Plug Lamp Module: 1 Ø1.0 (25.4mm) thru 2 Ø0.625 (15.88mm) V-port Lamp Type: 00 EKE, 3250K (standard) 01 EKE-HC, 4200K (high color temperature) 02 EJV, 3200K (high output) Material Type: X Standard material finish Modifications: To Be Determined (consult factory) 5

Contents Getting Started / Description MODEL 21DC Getting Started 8 Unpacking 8 Hookup Overview 8 Description 8 Illuminator Descriptions (Front Panel) 8 Illuminator Descriptions (Rear Panel) 9 Lamp Replacement 10 Specifications 12 Model Codes 13 Unpacking - MODEL 21DC Check that you received all items on the packing list. Hookup Overview The Model 21DC Illuminator allows you to connect and control a variety of fiber optic components. To learn the locations and names of important connections see Illuminator Descriptions beginning on this page below. Before You Get Started Turn off the power to the Model 21DC Illuminator before making any connections. Do not connect the AC power cord to the local power supply until the connections are completed to the Model 21DC Illuminator. Be sure to make connections firmly. Be sure that the Model 21DC operating voltage matches the local power supply. Illuminator Descriptions (Front Panel) 1. Variable intensity control knob (0 to 100%). 2. Power and lamp life indicators 3. Front panel fasteners (2X) 4. Lamp module. 5. V-port with T-handle retainer 7 8

Description Lamp Replacement Illuminator Descriptions (Rear Panel) 1. T-slot mounting for #1/4-20 or M6 hexhead fastener; both sides (#10-32 or M5 barnut optional) 2. IEC inlet with line filtering (power cable input) 3. Operating voltage label: Intensity Control Pin 4 activates remote operation when tied to common (pin 2 or 7). Note: Front panel control is disengaged during remote operation. Intensity level is controlled by Pin 3 by supplying a 0-5DC signal The internal voltage from Pin 1 may be used in conjunction with a remote potentiometer to vary intensity through Pin 3. Remote On/Off Unit power, including the lamp, is controlled by Pin 6. An external isolated signal (5VDC, 10mA) will shut off power to the lamp. Power is restored to the lamp by removing the 5VDC signal from Pin 6 (open). Lamp Error Signal 4. DB-9 connector for remote operation Pin 9 is the lamp error signal output. If Pin 9 is at 5V, the lamp is okay. If Pin 9 is at 0V, the halogen lamp will burn out in the near future, or it is burnt out, or there is no lamp in the lamp module. Pin 9 is at 5V when the Lamp Life indicator is unlit. Pin 9 is 0V when the Lamp Life LED indicator is lit. Illuminator Installation and Mechanical Dimensions 1 = Internal 1mA, 5VDC output 2 = Secondary common (same as 7) 3 = Lamp intensity control 4 = Ties to common to engage supply programming 5 = No connection 6 = External shut off/interlock (external 5VDC/10mA will shut off lamp) 7 = Secondary common (same as 2) 8 = Chassis ground 9 = Lamp error signal 9 10

Lamp Replacement Specifications Lamp Replacement Instructions 1. To replace the lamp, shut off the power and remove the power cord from the AC outlet. To disconnect the AC power cord, grasp the plug itself; never pull the cord. 2. Located on the lamp access panel, manually loosen the front panel fasteners. 3. With front panel released, remove the lamp module from the unit. Use caution; fan blades are accessible while lamp module is removed. 4. Allow sufficient time for the unit to cool. CAUTION: Lamp and surfaces may be extremely hot! 5. Remove the lamp from the socket and place in a safe area. 6. Insert the replacement lamp into the socket; pressing firmly to ensure that pins are fully seated. 7. Close the access panel. 8. Secure the lamp access panel by manually tightening the front panel fasteners. Specifications Environmental Intended for indoor use only Operating temperature: -4 to 104 F (-20 to 40 C) Humidity range: 0 to 80%; non-condensing Pollution degree: 2 Electrical Power consumption: 180W (Power factor corrected for CE) Power requirements: 90-254 VAC; 47-63 Hz Lamp adjustment range: 0 to 100% Color temperature: 3200K at maximum intensity (assuming standard EKE lamp) Lamp life: 250 to 10,000 hours Agency approvals UL 1950, CSA, CE, TUV & FCC (Pending) Physical Mass (approx.): Replacement Parts 4.5lbs. (2.04kgs) Lamp Replacement Lamp Type: 150W EKE, 3250K (#20094145)* 150W EKE-HC, 4200K (#20094142) 150W EJV, 3400K (20094143) * Standard lamp type provided with illuminator. Fuse Replacement Fuse Type: 3.15A 250V, 5x20mm (#02610014) On Safety Should any solid object or liquid fall into the assembly while access panel is open, have it checked by qualified personnel before operating. 11 12

Model Codes Model 21DC Matrix 21DC L K 1 0 0 -X Modifications Material Type Lamp Type Iris Module Lamp Module (nosepiece) Cord Set Input Voltage Model E:MAIL Chuck Mathewson blue@techniquip.com George Grauer gg@techniquip.com Dave Wensley dw@techniquip.com PHONE Toll Free 888-414-0789 International 1-925-251-9030 Fax 925-251-0704 Model: 21DCModel 21DC Note: All options are universal input (90-254VAC; 47-63Hz) and include 0-5V analog control capabilities. MAILING Street: 5653 Stoneridge Dr., Suite 101, Pleasanton CA 94588 Mailing: PO Box 3310, Danville, CA 94526 Options: U Standard DC regulated operation P DCU w/pc interface (RS232) S DCU w/optical loop feedback, no PC interface L DCU w/optical loop feedback and PC interface Cord Set: A Euro/Shuko K North America C Australia L Switzerland D United Kingdom Z North America H Israel X No Plug Lamp Module: 1 Ø1.0 (25.4mm) thru 2 Ø0.625 (15.88mm) V-port 3 Ø1.0 (25.4mm) V-port for use with/ir & color filter 4 Ø1.0 (25.4mm) V-port w/2 Hz shutter Warranty TechniQuip warrants this product to be free from defect in material and workmanship for a period of 12 months following original purchase. This warranty excludes any product which may have been misused, neglected, damaged, or altered including nonfactory authorized repairs. TechniQuip s obligations under this warranty are limited to the repair, replacement, or reimbursement of the product only, and in no event is TechniQuip liable for any consequential or special damages, or any cost related to transportation, installation, or any other cost related to a warranted product. Lamp Type: 0 EKE, 3250K (standard) 1 EKE-HC, 4200K (high color temperature) 2 EJV, 3200K (high output) Material Type: X Standard material finish Modifications: To Be Determined (consult factory) 13

Version A 04.15.06 5653 Stoneridge Drive #101 Pleasanton, CA 94566 Phone: 925-251-9030 Fax: 925-251-0704 1-888-414-0789 (toll-free)