Red/green-LED for switching state indication (dyn.) Yellow LED for dirt accumulation indication

Similar documents
TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

SERIES PR90H PROGRAMMABLE INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS REFERENCE PR90H - C C - C. External diameter 58 mm

PHOTOELECTRIC S300 PA MAXI SENSORS APPLICATIONS.

PRODUCTS FOR ELECTRIC VEHICLE CHARGING STATIONS

SERIE 59S. Rear clamp. Frontal clamp INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS SIN/COS

Electronic Pressure Switch EDS 3000

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution programmable

Actuator piston position Sensor Type SHE

Electronic Pressure Switches

Electronic Pressure Switches

Pressure Transmitters

MXR-S-300 Series with 24V DC Input and 50kV Output

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Model Pressure range ON/OFF output Linear output

SA1W: Water Detection Sensors

Steering column and sensor

Sensor for Production and Quality Control QMS 70 SAP-T. Hossbach Sensor Technologie

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2

General Purpose Incremental Encoder

Contents. Part no.: MLC500T Safety light curtain transmitter

OIS21C. Optical smart sensor for hydraulic cylinders. General Description. Features. Applications. Pin Functions. Ordering Information

Beck. The differential pressure transmitter for air with IP65

Air Flow Controller M1compact Type-Summary FKM 130

Inductive Proximity Sensor

Electronic Temperature Sensor ETS 300

Safety Door Handle System with SIDENT Safety Switch Ref. no , -11, -12

APPLICATIONS. Automatic assembling lines Palletizers and Depalletizers

Ring Style Sensors 98 Altech Corp. 35 Royal Road Flemington, NJ Phone (908) Fax (908)

Rotative measurement Incremental rotary encoder RI-10S10C-2B500-H1181

VHS... Screw Flow Meter

Inductive Proximity Sensor

User Guide. Panel Mount Digital Tachometer. Model Washington Street Melrose, MA Phone Toll Free

Rotary Sensor potentiometric Heavy-duty. Series IPX-7900

Adjustment range. Seal material. Pressure connection

Model Pressure range ON/OFF output Linear output

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

Emergency lighting units EM LED Light Engines

E2EZ-X2D1-N E2EZ-X2D2-N

optical sensors through-beam, retro-reflective, dif. reflection sensors 2300 visible red light robust metal housing

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

Pressure transmitter for industrial applications Type MBS 4510

CATALOGUE Opto-Electronics STRACK LIFT AUTOMATION ILGT

Contents. Part no.: MLC510R Safety light curtain receiver

EFFI-Line : High power LED linescan illumination system

Homogeneous Backlight

Datasheet. Oslon10 Cluster White. LED Solutions. ILR-ON10-xxxx-SC201-xx series. Product Overview. Applications. Technical Features:

Electronic pressure switch with two switching outputs

sensors SA1C-F High-speed Fiber Optic: SA1C-F

Pluggable interface relays RT, PT and MT range

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

PMS - PKS / PMW - PKW series

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Incremental encoders Insulated through hollow shaft ø inch pulses per revolution programmable (interpolated system)

General_technical_data Series

SP/SF Series Flow Switches

E2K-L. Liquid Level Sensor. Applications. Ordering Information

CTE7000 / CTU7000 Series Miniature pressure transmitters

More Precision. mainsensor Magneto-inductive displacement sensor

DTK. OEM Pelton Wheel Flow Sensor

Operating instructions Binary level sensor. LI214x /00 04/2016

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

SECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS

Pneumatic cylinders, piston-ø 8 25 mm Single acting DIN ISO 6432

Photoelectric Sensors 55 Series

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

HFX & HFXE T8 ELECTRONIC BALLAST & COMBINED ELECTRONIC BALLAST AND EMERGENCY INVERTER FOR EX-ENVIRONMENT

Vacuum pumps/generators Small

Compact cylinders series NYD Double acting with magnetic piston, ISO M5 to G1/8 Piston Ø 20 to 100 mm

Digital display Pressure range ON/OFF output Linear output Model

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Rotary actuators Rack-and-pinion gears series TRR. Brochure

Flow measurement FlexFlow PF20H Hygienic flow sensor

Sensors. RDS offers a wide range of sensors designed for low cost and harsh environments.

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

Cable Plug acc. to DIN EN , Form A

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Type 2REX-A. Oil & Gas / Heavy Industry

Inductive Proximity Sensor

P1Z Series Guided Version

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

Rotative measurement Incremental rotary encoder Ri-10S10C-2B5000-H1181

ANEMOMETER Vaisala WAA252

SUPERPROX Ultrasonic Proximity Sensors

HYDRUS ULTRASONIC METER

Rotative measurement Incremental rotary encoder Ri-10S10C-2B1000-H1181

Linear Guides Series OSP-E

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE

E2EM-X4X1 2M * E2EM-X4X2 2M Shielded E2EM-X8X1 2M * E2EM-X8X2 2M. M30 15 mm E2EM-X15C1 2M E2EM-X15C2 2M. M18 16 mm E2EM-X16MX1 2M E2EM-X16MX2 2M

Series 7000 Torque Sensor for PTO-shafts

JUMO MIDAS S05 Pressure transmitter Type

DISTRIBUTORS. n o p q. hdm + multi-pole connection TECHNICAL DATA COMPONENTS

Inductive Proximity Sensor

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

ProMinent. Operating Instructions Turbine Meter turbodos

Pressure sensor for liquid and gaseous media QBE620-P...

Diaphragm Valve, Plastic

ISO/VDMA Series ISO 6431 and VDMA Cylinder Line

Transcription:

FLB Series FLB-F2-...-HS (High Speed) - High switching frequency (10kHz) - Integrated electronics - High sensitivity (adjustable via 5-step switch) - Pulse length adjustable via 5-step switch - Dynamic and static output - Analog output optional (0V... +10V) - Switching state indication by means of a red/green LED - Dirt acculumation indication by means of a yellow LED - Transmitter/receiver distance variabel by means of crosshead - Mechanical protection of optics, sturdy aluminum housing Design Product name: FLB-F2-(size)*-Q-HS FLB-F2-(size)*-Qinv-HS FLB-F2-(size)*-Q-ANA-HS Cold light reflector (protected by means of a baffle plate, not shown in the drawing) Housing made of aluminium, anodized in blue Q = Switching output: PNP bright-switching (PNP n.c.) NPN dark-switching (NPN n.o.) Transmitter side Qinv = Switching output: PNP dark-switching (PNP n.o.) NPN bright-switching (NPN n.c.) Receiver side ANA = Additional analog output (0V... +10V) 5-step switch for sensitivity setting Red/green-LED for switching state indication (dyn.) Yellow LED for dirt accumulation indication 5-step switch for setting of pulse length Picture shows FLB-F2-...-HS with 1 crosshead (please order crosshead separately) *Available sizes: (dimensions cf. page 3) A = 60 / 80 / 100 / 160 / 200 / 300 mm (A = width of cold light reflector) Product name crossheads: FLB-TRA-60 = max. 60 mm distance transmitter/receiver (total length of crosshead = 105 mm) (dimensions cf. page 3 and 8-11) FLB-TRA-80 = max. 80 mm distance transmitter/receiver (total length of crosshead = 125 mm) FLB-TRA-100 = max. 100 mm distance transmitter/receiver (total length of crosshead = 145 mm) FLB-TRA-155 = max. 155 mm distance transmitter/receiver (total length of crosshead = 205 mm) FLB-TRA-355 = max. 355 mm distance transmitter/receiver (total length of crosshead = 400 mm) FLB-TRA-555 = max. 555 mm distance transmitter/receiver (total length of crosshead = 600 mm) FLB-TRA-755 = max. 755 mm distance transmitter/receiver (total length of crosshead = 800 mm) (2011-03-29) FLB-F2-HS / Page 1 of 11

Technical Data Model Max. transmitter/ receiver distance Min. detectable object FLB-F2-...-HS 800 mm typ. 0.6 mm Optical filter Cold-light reflector Light type Infrared Voltage supply +12VDC... +32VDC, protected against polarity reversal, overload protected Pulsating light operation approx. 5 khz Ambient light up to 5000 Lux Type of protection IP67 Current consumption 200 ma E MC test acc. to IEC - 801... Connector type Operating temperature range Transmitter side: 5-pin connector, Binder Series 712, receiver side: 8-pin connector, Binder Series 712 Connection to PLC: 7-pin connector, Binder Series 680-20 C... +60 C Storage temperature range -20 C... +85 C Housing Aluminum, anodized in blue Max. switching current 200 ma, short-circuit-proof Switching Output digital Analog frequency output typ. 10 khz Q: PNP bright-switching (PNP normally closed), NPN dark-switching (NPN normally open) Qinv: PNP dark-switching (PNP normally open), NPN bright-switching (NPN normally closed) with option -ANA: 0V... +10V Sensitivity setting in 5 steps by means of step switch P ulse lengthening in 5 steps by means of step switch (20 ms... 300 ms) Dirt accumulation display By means of yellow LED and digital DIRT ACCUMULATION output S witching state display By means of bi-color LED: RED (object passes light curtain) / GREEN (light curtain free, or no change) Intensitiy setting in 5 steps by means of step switch (2011-03-29) FLB-F2-HS / Page 2 of 11

Dimensions FLB-F2-(size)-...-HS: Size A (mm): 60 80 100 160 200 300 FLB-TRA-(width): Width B (mm): A B C D E F G 60 80 100 155 355 555 755 60 80 100 160 200 300 B (FLB-TRA-B) 27.5 A + 14 B + 20 A + 59 B + 47.5 (2011-03-29) FLB-F2-HS / Page 3 of 11

Connector Assignment Connector assignment for FLB-F2-...-HS: 5-pole connector (transmitter side) Pin No.: Assignment: 1 GND (0V) 2 +Ub (+12VDC... +32VDC) 3 F0 4 /F0 5 Window 3 2 1 5-pole connector, 4 5 8-pole angle female connector, 5-pole angle female connector, 8-pole connector (receiver side) Pin No.: Assignment: 1 GND (0V) 2 +Ub (+12VDC... +32VDC) 3 Output DYN 4 Output STAT 5 with "Q": Output DIRT ACCUMULATION with "Qinv": Output INV DYN with "ANA": ANALOG (0V...+10V) 6 F0 7 /F0 8 Window 5-pole connector, 2 1 8-pole conn., (l=0.5m) 3 7 (l=0.3m) 4 6 Connecting cable: cab-flb-y (l=0.3m/ 0.5m) 4 5 8 8-pole connector, Connecting cable to PLC: cab-flb7/680-f2 (l=2m) 2 3 5 1 7 6 7-pole connector type 680 Connecting cable cab-flb7/680-f2: Pin No.: Assignment: Color: 1 Output DYN white 2 Output STAT black 3 with "Q": Output DIRT ACCUMULATION grey with "Qinv": Output INV DYN with "ANA": ANALOG (0V...10V) 4 n.c. yellow 5 GND (0V) blue 6 +Ub (+12VDC... +32VDC) brown 7 n.c. green 7-pole connector type 680 (connecting cable cab-flb-y): Pin No.: Assignment: 1 Output DYN 2 Output STAT 3 with "Q": Output DIRT ACCUMULATION with "Qinv": Output INV DYN with "ANA": ANALOG (0V...10V) 4 n.c. 5 GND (0V) 6 +Ub (+12VDC... +32VDC) 7 n.c. (2011-03-29) FLB-F2-HS / Page 4 of 11

Setting Sensitivity setting (step-switch E ): Sensitivity can be adjusted by means of a step-switch. The term sensitivity defines the minimum detectable part size. The sensitivity can be adjusted in 5 steps. Adjustment of pulse lengthening (step-switch Z ): The pulse length of the dynamic output can be adjusted by means of a step-switch. 5 pulse lengths are available. (FLB-FR1, FLB-FK1) (FLB-FR1, FLB-FK1) FLB-F2-...-HS FLB-F2-...-HS Step Part size (dyn.) Part size (stat.) Step Pulse length 1 >= 0.5 mm >= 2 mm 1 300 ms E Z 2 >= 0.7 mm >= 3 mm 2 200 ms E Z 3 >= 1.3 mm >= 5 mm 3 100 ms E Z E 4 >= 1.7 mm >= 7 mm Z 4 50 ms E 5 >= 2.5 mm >= 10 mm Z 5 20 ms Dirt accumulation display (yellow LED): In addition to a digital dirt accumulation output the user is informed about the dirt accumulation status by means of a yellow LED. If this yellow LED lights up, the transmitter or receiver side should be checked for dirtying. Switching state display (red/green LED): The switching state is indicated by a red/green LED. In case that a measuring object is detected, the LED changes from GREEN to RED. The two-color-led is coupled to the dynamic output, i.e. after pulse end the LED returns to its starting state = GREEN. (FLB-FR1, FLB-FK1) (FLB-FR1, FLB-FK1) FLB-F2-...-HS FLB-F2-...-HS (2011-03-29) FLB-F2-HS / Page 5 of 11

Setting Adjustment of intensity (step-switch I): With the FLB-F2-...HS type the intensity (IR light output) is adjusted to the respective transmitter/receiver distance by means of a 5-step switch. Step Transmitter/receiver distance 1 <= 15 mm I 2 <= 40 mm I FLB-F2 I 3 <= 80 mm 4 <= 150 mm I I 5 > 150 mm (2011-03-29) FLB-F2-HS / Page 6 of 11

Connecting Cable Connecting cable cab-flb-y-... Available lengths: (l=0,5m) cab-flb-y-0,3m/0,5m (l=0,3m/0,5m) cab-flb-y-0,5m (l=0,5m/0,5m) cab-flb-y-1m (l=1m/1m) cab-flb-y-2m (l=2m/2m) cab-flb-y-3m (l=3m/3m) Connection to 5-pole connector (FLB-F2 transmitter side) (l=0,3m) Connection to 8-pole connector (FLB-F2 receiver side) e.g.: cab-flb-y-0,3m/0,5m Connection to cab-flb7/680-f2-... (to PLC) Senkung DIN 74-Km4 (2011-03-29) FLB-F2-HS / Page 7 of 11

Crossheads Available crossheads: FLB-TRA-60 FLB-TRA-80 FLB-TRA-100 FLB-TRA-155 FLB-TRA-355 FLB-TRA-555 FLB-TRA-755 Distance FLB-F2 transmitter/receiver = max. 60 mm (total length crosshead = 105 mm) Distance FLB-F2 transmitter/receiver = max. 80 mm (total length crosshead = 125 mm) Distance FLB-F2 transmitter/receiver = max. 100 mm (total length crosshead = 145 mm) Distance FLB-F2 transmitter/receiver = max. 155 mm (total length crosshead = 205 mm) Distance FLB-F2 transmitter/receiver = max. 355 mm (total length crosshead = 400 mm) Distance FLB-F2 transmitter/receiver = max. 555 mm (total length crosshead = 600 mm) Distance FLB-F2 transmitter/receiver = max. 755 mm (total length crosshead = 800 mm) FLB-TRA-60 FLB-TRA-80 FLB-TRA-100 (2011-03-29) FLB-F2-HS / Page 8 of 11

Crossheads FLB-TRA-155 FLB-TRA-355 FLB-TRA-155 FLB-TRA-355 FLB-TRA-355 FLB-TRA-155 (2011-03-29) FLB-F2-HS / Page 9 of 11

Crossheads FLB-TRA-555 (2011-03-29) FLB-F2-HS / Page 10 of 11

Crossheads FLB-TRA-755 (2011-03-29) FLB-F2-HS / Page 11 of 11