NORTH NEW SOUTH WALES RANGE GREY BLOCKS. standard masonry units

Similar documents
NEW SOUTH WALES RANGE AUSTRALITE. concrete masonry blocks

Alphalite. Grey Concrete Blocks. South East Queensland. May 2014 Edition. masonry. style and function

Brick Specials. British Standard

Design Range 100 s and 200 s EXCLUSIVE FROM GARADOR. Specifically designed to provide a perfect match for our FrontGuard entrance doors

MESA Cornerstone Segmental Retaining Wall Unit and Tensar Geogrid Connection Strength Testing

PUR-O-STOP FS-L. General Building Inspectorate Approval for curtain grouting CE-marking in accordance with EN

porcelain tiles of distinction

Technical. Supplement. Stramit Purlin & Girt BRIDGING DETAILING GUIDE

SEVENTH EDITION HOT ROLLED AND STRUCTURAL STEEL PRODUCTS

COVER ACCENT OPAQUE SMOOTH / SUPER SMOOTH VELLUM / WARM WHITE FEATURES / BENEFITS END USES

Weldlok Drainage Products

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

INSTALLATION GUIDELINES

kerb and gully range fast delivery on ex-stock items to any postcode nationwide

ADTFM-im -issue INSTRUCTION MANUAL DIGITAL DIESEL METER ADTFM

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath

Cut to Size Plastics Pty Ltd

SERVICE SHEETS FLOOR GRINDER ART-CUB SINGLE PHASE WARNING

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Sectional Garage Doors Alutech Trend Series Price List

Int l Beauty Show/IECSC LVCC June 24-26, 2017 FIRM NAME: AMOUNT ENCLOSED $

PAVERS PRICE LIST (gst exclusive) - October 2017 (prices subject to change without notice)

The Pump Matic Range

Whitecroft Lighting Limited

Show: IJO Orlando Location: Marriott World Center Date: March 5-9, 2016 FIRM NAME: AMOUNT ENCLOSED $

Trelleborg en g INeereD SYSTeMS Marine Fenders

G.C. Supplies UK Limited

MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF

Quick-find Index. Lifting & Rigging

ADVANCED PRICE PRICE FOR ORDERS RECEIVED AFTER 02/15/19 $ $ $ $ $ $ $ $355.00

Geoscience Testing laboratory (Al Ain)

Installation Guide Rollerdor RD55 Econ Roller Garage Door

LED T8 Full Glass Tube

Metalcraft. Insulated Panel Systems PERSONAL ACCESS DOORS

SAS International +44 (0) tubeline. tubular linear ceiling

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

/2017 Samson ThermoTeck Speed Insulated Roller Shutter

Instruction Manual Ultima 4 Plate Brake Test System

ZIP LIGHT LED LUMINAIRE

Title Requirements for Electric Aerials Crossing ARTC Infrastructure. Reference Number PYS 02 - (RIC Standard: EP SP)

ALL-INCLUSIVE 2018 ALUMINIUM FRONT DOORS WITH BREAK-IN PROTECTION

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

06 November /13675-R. Mr. Julian Reusing President & CEO GoliathTech Inc. 175B, rue Peladeau Magog, QC J1X 5G9. Dear Mr.

HI-CUT - Steel. CUMISTAR - Stainless Steel ZIRCONIA. Depressed Centre Grinding Wheels - Type 27

RODIA Diamond Core Drilling RODIA Diamond Drill Bits

Rapid Lifting Anchor System. Connector Ring Clutch (t)

Contents SAE Compliant LED Lamps

Floatation Systems. Pipeline Hose Polyethylene. Rotational. Pontoon. Viscount Rotational Mouldings. Collar Slurry

New York Comic Con Show Jacob K. Javits Convention Center October 11-14, 2012

VR2-CC VR2-RS VR2-ES PRODUCT MANUAL

1¾" BEAMS & HEADERS. [1¾" THICKNESS] NER F b E Design Values LAMINATED VENEER LUMBER. Finnforest USA, Engineered Wood Division

Evaluation Report CCMC R Ram Jack Helical Foundation Systems and Devices

Septic Tank. Installation Guidelines

Cable-Tight Wire Management System

OFFICIAL DISPLAY CASE RENTAL ORDER FORM. New York Comic Con Jacob K. Javits Convention Center October 10-13, 2013

Installation, Care and Maintenance Instructions. Optiflush OP1 Battery and OP2 Mains Versions

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

Detroit Speed, Inc. Subframe Connectors Camaro/Firebird P/N:

OFFICIAL DISPLAY CASE RENTAL ORDER FORM. New York Comic Con Jacob K. Javits Convention Center October 9-12, 2014

NEU NEW NOUVEAU NUEVO NIEUW NY

No coatings are used in the production of the Durus.

Vertical Blinds. 3. Slat width must also be specified 127mm or 89mm. 4. Please state:

Contents. Tube in Tube. Tube on Tube. 4 Column. 3 Column. 2 Column. Traditional. Column. Technical Diagrams. Straight Chrome. Straight.

Standard BS Standard Concrete Kerb

TOC Waiver. ARTC website

The Sika Solution x 600 x 700H / 900H. Class D. Roadway Installation Guidelines p 9-11

TEC LINE PE/PVC PIPES

Tank Wall Installation Procedure

DOOR BOTTOM SMOKE SEALS

Quality around the clock! Series 13

markilux 970 The compact cassette awning with the straight design with extended size matrix: available up to 600 cm width and 350 cm projection

Nanometrics Solar Power System

Easy to Work With. Repair or replacement applications. Covers load tested to Australian Standards

Small Powered Vacuum Lifters. for horizontal transports. Easy Solutions For Heavy Loads. Small Powered Vacuum Lifters

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF. Info Flexible fine-wire copper conductor

Heating with a. Difference. Now Available. Keeping Australia Warm! LOW EMISSION HIGH EFFICIENCY SERIES 8 RANGE. Up to 72% As low as 1.

Electrical. Earthing & Bonding. Installation Techniques. Learning Notes MODULE 2.2 UNIT PHASE:2

Ridder Equipment. Our commitment to you... Tel Fax:

Corrugated Conduit - Medium Duty Grey PVC

PALM ISLAND CHARGES: FINANCIAL YEAR (Appendix 1a.) Effective from 1 July 2014

Instruction Manual September milltronics A SERIES

Main Toll Free Range Road 73, Parkland County, Alberta T0E 0S0

Aqua-safe. Waterproof Plug & Socket Connectors Simply better designed

Aluminium sliding gate

NexT Range Large sheet steel enclosures

Midwest Roadside Safety Facility

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

This is a guide only.

3.1 Overview of ATCO Electric s URD System Design

Patios Porches Pools Walkways

SAMPLING SAMPLING Model: Product Data Sheet Pico Vibe. 9mm Vibration Motor - 25mm Type

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

Louvre systems. Series WLD Weather louvre doors. Incorporating. Fully active louvre panel integrated into a door

DECORATIVE PANEL.

FORZA HORIZONTAL FORZA HORIZONTAL

CERTIFICATE OF APPROVAL No CF 557 JOTUN PAINTS (EUROPE) LIMITED

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

From a modest beginning in 1976 producing small. quantities of gravity conveyor rollers, Arnott Handling

HAND CRIMP TOOL SPECIFICATION SHEET Order No (Replaces HTR1719C)

Transcription:

NORTH NEW SOUTH WALES RANGE 10-2016 GREY BLOCKS standard masonry units

GREY BLOCK range GREY BLOCKS standard masonry units All blocks 15MPa and 2-hour fire rating (insulation), unless otherwise noted. All available in Standard Grey. Block Range 100mm series ( - 15 MPa) 2 hour insulation on Standard Grey blocks unless otherwise specified. 10-01 Full 390 L x 90 W x 190 H mm 180 8.7 kg 15 120 10-02 Three quarter 290 L x 90 W x 190 H mm 240 8.2 kg 15 120 10-03 Half 190 L x 90 W x 190 H mm 360 4.8 kg 15 120 10-04 Quarter 90 L x 90 W x 190 H mm 720 2.8 kg 15 120 10-25 Corner return 390 L x 190 W x 190 H mm 120 12.3 kg 15 120 10-71 Half high 390 L x 90 W x 90 H mm 360 4.8 kg 15 120 10-83 Half high solid 390 L x 90 W x 90 H mm 288 6.0 kg 15 120 10-31 Solid 390 L x 90 W x 190 H mm 144 12.2 kg 10 120 / 3 /

AUSTRAL MASONRY Block Range 150mm series ( - 15 MPa) 2 hour insulation on Standard Grey blocks unless otherwise specified. 15-01 Full 390 L x 140 W x 190 H mm 144 11.23kg 15 120 15-03 Half 190 L x 140 W x 190 H mm 240 5.7 kg 15 120 15-12 Lintel or bond beam 390 L x 140 W x 190 H mm 120 16.8 kg 15 120 15-25 Corner return 390 L x 190 W x 190 H mm 105 16.1 kg 15 120 15-83 Half height solid 390 L x 140 W x 90 H mm 192 9.2 kg 15 120 15-42 Recessed web 390 L x 140 W x 190 H mm 144 10.8 kg 15 120 15-48 H block 390 L x 140 W x 190 H mm 144 10.8 kg 15 120 15-71 Half height 390 L x 140 W x 90 H mm 288 5.7 kg 15 120 15-83 Half height solid 390 L x 140 W x 90 H mm 192 9.2 kg 15 120 15-709* 4 hour insulation 390 L x 140 W x 190 H mm 144 18.6 kg 10 240 * Note: Made to order / 4 /

GREY BLOCK range Block Range 200mm series ( - 15 MPa) 2 hour insulation on Standard Grey blocks unless otherwise specified. 20-01 Full 390 L x 190 W x 190 H mm 126 13.3 kg 15 120 20-02 Three quarter 290 L x 190 W x 190 H mm 144 11.8 kg 15 120 20-03 Half 190 L x 190 W x 190 H mm 180 7.52 kg 15 120 20-12 Lintel 390 L x 190 W x 190 H mm 90 18.2 kg 15 120 20-71 Half high 390 L x 190 W x 90 H mm 180 7.3 kg 15 120 50-31 Capping 390 L x 190 W x 40 H mm 288 5.2 kg N/A N/A 20-05* 4 hour insulation 390 L x 190 W x 190 H mm 108 16.4 kg 10 240 * Note: Made to order / 5 /

AUSTRAL MASONRY Retaining Wall Range 200mm series ( - 15 MPa) 20-42 Recessed web 390 L x 190 W x 190 H mm 126 12.5 kg 15 120 20-91 Stretcher 390 L x 190 W x 190 H mm 126 11.0 kg 15 120 20-48 H block 390 L x 190 W x 190 H mm 126 11.2 kg 15 120 20-92 Corner & end 390 L x 190 W x 190 H mm 126 11.8 kg 15 120 20-61 Clean out 390 L x 190 W x 190 H mm 108 10.8 15 120 Block Range 300mm series ( - 15 MPa) 30-01 H block 390 L x 290 W x 190 H mm 84 19.4 kg 15 120 30-48 H block 390 L x 290 W x 190 H mm 84 15.4 kg 15 120 20-02 Half block 290 L x 190 W x 190 H mm 144 11.8 kg 15 120 30-92 End 390 L x 290 W x 190 H mm 84 17.5 kg 15 120 30.45 Clean out 390 L x 290 W x 190 H mm 72 14.9 15 120 / 6 /

GREY BLOCK range Concrete commons per square Durability Common 230 L x 110 W x 76 H mm 500 48.5 3.5 kg 12 180 EXP Retaining wall details Core fill quantities Block Type 15-42 15-48 20-01 20-42 20-91 20-48 30-48 No. blocks filled per m 3 of concrete grout 170 150 110 125 100 100 70 20.42 and 20.48 clean out course and starter bar spacing 30.48 clean out course and starter bar spacing 100 Starter bar spacing to engineers details (usually 400mm) 20.61 100 Starter bar spacing to engineers details (usually 400mm) 20.61 10-04 may be added for extra support to next course 10-04 10-03 required to make up wall width Core spaces at ends and corners for 20.91 systems 200 mm clean out course for 20.91 100mm 300mm* Core holes are spaced at 200mm centres 15.22 10.03 10.02 30.93 20.61 2 2 15.03 Corner details *20-91 system only. Corner 15.22 10.02 Steel bars 10.34 may be added for extra stability 200mm Clean-out Course for 20.91 15.25 15.25 10.25 10.02 10.25 10.0310.02 10.03 10.04 15.22 15.03 10.02 10.02 20.92 30.48 / 7 /

STYLE AND FUNCTION www.australmasonry.com.au 1300 masonry (1300 627 667) DESIGN CENTRES Coffs Harbour 27 Lawson Crescent Coffs Harbour NSW 2450 Tel: (02) 6652 3457 Fax: (02) 6651 4362 E: orderscoffs@australmasonry.com.au a member of a member of proud proud supporters Austral Masonry is part of the Brickworks Group 1. Stock colours. Colours other than stock colours are made to order. Contact your nearest Austral Masonry office for your area s stock colours. A surcharge applies to orders less than the set minimum quantity. 2. Colour and texture variation. The supply of raw materials can vary over time. In addition, variation can occur between product types and production batches. 3. We reserve the right to change the details in this publication without notice. 4. For a full set of Terms & Conditions of Sale please contact your nearest Austral Masonry sales office. 5. Important Notice. Please consult with your local council for design regulations prior to the construction of your wall. Councils in general require those walls over 0.5m in height and/or where there is loading such as a car or house near the wall be designed and certified by a suitably qualified engineer. 6. Max wall heights disclaimer. The gravity wall heights are maximum heights calculated in accordance with CMAA RW03 Appendix D guidelines and a qualified engineer should confirm the suitability of the product for each application. As such, due consideration must be given to but not limited to: Cohesion. Dry backfill, no ingress of any water into the soil behind the retaining wall. All retaining walls are designed for zero surcharge unless noted otherwise. These walls are intended for structure Classification A walls only as defined in AS4678 Earth Retaining Structures as being where failure would result in minimal damage and/or loss of access. The product images shown in this brochure give a general indication of product colour for your preliminary selection. Austral Masonry recommends all customers see actual product samples at a selection centre prior to making final selections.