TELEDYNE HASTINGS INSTRUMENTS

Similar documents
TELEDYNE HASTINGS INSTRUMENTS

HASTINGS INSTRUMENTS. AVG and AVC MODULE

TELEDYNE HASTINGS INSTRUMENTS

USER MANUAL LVC-200TC DIGITAL THERMOCOUPLE VACUUM GAUGE

TELEDYNE HASTINGS INSTRUMENTS

Myers Vacuum 1155 Myers Lane Kittanning, PA Phone: Fax: Instruction Manual For Thermocouple Vacuum Gauge GTC-390

TELEDYNE HASTINGS INSTRUMENTS

Myers Vacuum RD # 2 Box 247A Kittanning, PA Phone: Fax: Instruction Manual For Thermistor Gauge GT-340A

FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

HYGRODYNAMICS DEW POINT MONITOR MODEL 8092P 8092P-230VAC TABLE OF CONTENTS DIAGRAMS

Instruction Manual For Thermistor Vacuum Gauge GT-430

TELEDYNE HASTINGS INSTRUMENTS

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

Vacuum Gauge Catalog

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Pirani Vacuum Gauges. Digital and Analog Vacuum Gauge Systems. Features and Benefits. HPS Products (800) (303)

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Harris IRT Enterprises Digital Resistance Tester Model XP

DC POWER SUPPLY ALIMENTATION C.C.

Installation Manual WAV Version WAV HBX Control Systems Inc. Page 1

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

BP1204 INSTALLATION/OWNER'S MANUAL

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

User Guide. Model Insulation Tester / Megohmmeter. Introduction

INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC MODEL #091-9B-220. INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

INSTALLATION/OWNERS MANUAL

Terranova Model 924A Thermocouple Vacuum Gauge Controller

Telescopic Transmission Jacks

StarEye. 350 ma version. No control electronics on board

INSTRUCTION MANUAL. TEC Controller/Thermocouple Thermometer

ODY-19-1 AIR PRESSURE GAUGE

CONTACTING CONDUCTIVITY GENERAL PURPOSE SENSORS Instruction Manual

Model 2053 Conductivity Meter Instruction Manual

Phase Sequence Tester

Rental Industry Safety Tester Safe Check 5s

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

RESISTIVITY MONITOR/CONTROLLERS

PENBERTHY FROST PROOF EXTENSION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

MMV Digital Length Measuring Gauge INSTRUCTION MANUAL

PRG 350 Series Stainless Steel Regulators

Model Series 66 Amplifying and Reducing Relays

CONTACT TACHOMETER User s ManUal CT6235B

Model 102B15. ICP Pressure Sensor. Installation and Operating Manual

Model: SR635i Pediatric Scale with Cart Operating and Service Manual Part No.: MAN635i_ Page 1 of 18. Model SR635i. Pediatric Scale with Cart

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

powerdriveinverters.com Owner s Guide Please Save for Future Reference 100 Watt DC to AC Power Inverter

HASTINGS INSTRUCTION MANUAL 201/203 SERIES FLOWMETERS/CONTROLLERS. page 1

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

OWNER'S MANUAL POWER BOOSTER. Rechargeable 12 Volt DC power supply. Item # Enclose copy of original sales receipt

SSI Technologies MediaSensor

LNW-5. Installation... 2 Lift Truck Conditions Indicator Installation Hose Installation

powerdriveinverters.com Owner s Guide Please Save for Future Reference 150 Watt DC to AC Power Inverter

3 980/980E Ionized Air Gun Instruction Manual

INSTALLATION DATA MANUAL MODEL 148/248/348

3M Ionized Air Gun 980/980E. User s Guide

Heavy Duty Engine Cranes

OPERATING INSTRUCTION

Installation and Operating Manual

Electric Actuator Installation, Operation & Maintenance Manual

User Guide AutoTrans Conveyor. Operation & Service

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

HIGH VOLTAGE PROVING UNIT

Model 809 Diaphragm Gauge Controller

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

CONTENT 1 PICTURE GENERAL... 3

HXE4B BATTERY POWERED CRIMP TOOL

INSTRUCTIONS Installation/Operation/Maintenance

Installation Manual for the SHURflo LCB - G Pump Controller

Model P772 Conductivity Meter. User Manual

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation

PSG5xx ATM to Medium Vacuum Gauge

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Installation and Operating Instructions

50407 / DUAL INDEPENDENT FOOTWEAR AND WRIST STRAP TESTER

GF1900 SULFURYL FLUORIDE MONITOR

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

Operator Instructions for Tension Links

Superchips Model 2704 MAX MicroTuner GM Trucks with 6.6L Duramax Diesel Engines Vehicle Programming Instructions

KSZ 10B Current Probe Calibrator. Instruction Manual

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Hydraulic Transmission Jacks

Fluke 750P Series Pressure Modules

IONIZATION SOLUTIONS

HDE36B BATTERY POWERED CRIMP TOOL

Model B STRAIN GAGE LOAD CELL. Installation and Operating Manual

80PK-2A Type K Immersion Probe

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

Transcription:

TELEDYNE HASTINGS INSTRUMENTS INSTRUCTION MANUAL DIGITAL VT ISO 9001 C E R T I F I E D

Manual Print History The print history shown below lists the printing dates of all revisions and addenda created for this manual. The revision level letter increases alphabetically as the manual undergoes subsequent updates. Addenda, which are released between revisions, contain important change information that the user should incorporate immediately into the manual. Addenda are numbered sequentially. When a new revision is created, all addenda associated with the previous revision of the manual are incorporated into the new revision of the manual. Each new revision includes a revised copy of this print history page. Revision B (Document Number 162-062005)... June 2005 Revision C (Document Number 162-082005)... August 2005 Revision D (Document Number 162-112005... November 2005 Revision E (Document Number 162-092007)... September 2007 Revision F (Document Number 162-072009)... July 2009 Revision G (Document Number 162-082010)... August 2010 Revision H (Document Number 162-072012)... July2012 Visit www.teledyne-hi.com for WEEE disposal guidance. CAUTION: The instruments described in this manual are designed for INDOOR use only. CAUTION: The instruments described in this manual are designed for Class 2 installations in accordance with IPC standards Hastings Instruments reserves the right to change or modify the design of its equipment without any obligation to provide notification of change or intent to change. 162-072012 Digital VT Page 2 of 12

Table of Contents 1. GENERAL INFORMATION... 4 1.1 FEATURES... 4 1.2 SPECIFICATIONS... 4 1.3 SAFETY... 5 1.4 ACCESSORIES... 5 1.4.1 INSTALLATION ACCESSORIES... 5 1.4.2 DV-6S: NEW DV-6 TUBE FOR SEVERE ENVIRONMENTS... 5 1.4.3 CALIBRATION REFERENCE TUBES... 6 2. INSTALLATION... 7 2.1 DIGITAL VT, OUTLINE DIMENSIONS... 7 2.2 DIGITAL VT, FRONT PANEL... 7 2.3 DIGITAL VT, BACK PANEL... 8 2.4 MOUNTING LAYOUT... 8 3. VACUUM GAUGE OPERATION... 9 3.1 AC INPUT POWER... 9 3.2 QUICK START... 9 3.3 PRESSURE MEASUREMENT... 9 3.4 OPERATION AND PERFORMANCE... 9 3.5 TUBE SELECTION... 10 3.6 GAUGE TUBE OPERATING PRINCIPLE... 10 3.7 CALIBRATION PROCEDURE... 10 3.7.1 PREPARATION... 11 3.7.2 SET HIGH END... 11 3.7.3 SET LOW END W/VACUUM SYSTEM... 11 3.7.4 SET LOW END W/REFERENCE TUBE.... 11 4. WARRANTY AND REPAIR... 12 4.1 WARRANTY REPAIR POLICY... 12 4.2 NON-WARRANTY REPAIR POLICY... 12 162-072012 Digital VT Page 3 of 12

1. General Information This manual contains technical and general information relating to the installation, operation, and calibration of Hastings Vacuum Gauges, and Gauge Tubes. For best performance, Hastings vacuum gauges should be operated with the appropriate Hastings gauge tube. Attempting to use a Hastings vacuum gauge with other manufacturer s tubes may result in damage to both the gauge and tube. 1.1 Features The Hastings Instrument s Digital VT, is a digital readout version of the successful VT-Series Hastings Gauge which has generated loyal customers for over 50 years. A reputation has been built on exceptional stability, accuracy, and reliability under the most demanding conditions. A precision A/D converter, with a microprocessor is used to measure the gauge tube s signal output; it converts the measurement to a pressure reading using the gauge tube s well defined output/pressure function, and then display the result. The Digital VT Vacuum Gauge Meter is available for two Hastings Instruments most popular gauge tube families: The DV-6 and DV-4. The DV-6 range is 0-1000 mtorr. The DV-4 range is 0-20 Torr. All VT- Series Vacuum Gauges feature long life and minimal maintenance. These instruments utilize Hastings rugged noble metal TC gauge tubes that are designed specifically for each range. Tubes are matched and interchangeable without calibration adjustments. They are compensated for temperature, rate of temperature change and are corrosion resistant. 1.2 Specifications DIGITAL VT VACUUM METER: INPUT POWER... 4.5-5.3 volts DC, 155 ma... W/ INCLUDED POWER CONVERTER 90-240 VAC, 47-63 HZ, 2 WATTS CABLES (Approx.)... 6-ft. power cable and 8-ft. sensor cable included WEIGHT (Approx.)... 1 lb OPERATING TEMPERATURE RANGE... 5 O C to 50 O C STANDARD METAL GAUGE TUBE (DV-6R, DV-4R): OVERPRESSURE... 50 psig max. MATERIAL OF CONSTRUCTION... Nickel-Plated steel, Stainless Steel,... Glass, Noble Metal, Thermocouples. CONNECTIONS... 1/8-in. NPT male thread TUBE LEAK TEST... 10-8 SCCS GLASS... Available for high temperature bakeable systems... 3/8 in. O. D. (10mm) smooth tabulation VCR & KF CONNECTIONS... VCR female connection. 9/16-18 UNF, female threads... w/0.75 hex, Cajon No. SS-4 VCR-3 and No. SS-4-VCR 1. 162-072012 Digital VT Page 4 of 12

CE Standard Compliance Test SAFETY EMC/EMI Family CONDUCTED/RADIATED ESD RF FAST TRANSIENTS SURGE CONDUCTED IMMUNITY VOLTAGE DIPS Standard EN61010 EN61326 EN55011 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-11 1.3 Safety The following symbols and terms may be found on THI products and/or in THI manuals and indicate important information. When found on the device, this symbol indicates that the operator should refer to the manual for important instructions on the proper use of this device. When found in a manual, this symbol indicates that the reader should understand the implications contained in the text before operating the device. The WARNING label indicates important information that should be heeded for safe and proper performance of the device. The label, CAUTION, is used to indicate that the damage to the power supply or equipment connected to it, could occur if directions are not followed. Warranty could be invalidated if the instructions in this manual are not followed. 1.4 Accessories 1.4.1 Installation Accessories Hastings Instruments offers a complete line of system attachments that permit easy maintenance for contaminated operations. Gauge tubes are offered with various system fittings to match almost any system requirement. Additionally, Hastings complete line of quick disconnect attachments allows customers to install these special fittings and easily replace sensors without vacuum sealant or Teflon tape. For particularly dirty systems, Hastings offers a particle dropout trap containing a series of nine separate baffles which prevent solid contaminants from having a direct path to the sensor s thermopile. 1.4.2 DV-6S: New DV-6 tube For Severe Environments Hastings Instruments has developed a new gauge tube (DV-6S) which is specifically designed for outdoor use on cryogenic tanks including railcar and tanker truck applications. In addition to the Digital VT, the gauge tube is compatible with the hand-held HPM-4/6 and the analog VT-6. The DV-6S is supplied with a protective cap. The o-ring-sealed cap protects the gauge tube pins from moisture thus significantly reducing corrosion. A metal lanyard prevents cap loss. The tube is provided with a standard 1/8 NPT fitting; however special fitting requests can often be met. 162-072012 Digital VT Page 5 of 12

1.4.3 Calibration Reference Tubes Hastings Instruments Reference Tubes employ the same Hastings metal thermopiles used in all Hastings Vacuum Gauge Tubes. The thermopile is sealed in a glass capsule that has been evacuated, baked, outgassed, and then aged to ensure long-term stability. The sealed capsule is then housed in a protective metal shell to provide a rugged, trouble-free assembly. Once assembled, the reference gauge tube is accurately calibrated to precisely simulate a gauge tube at a given operating pressure. It provides quick and easy instrument re-calibration by merely plugging the instrument and adjusting the zero potentiometer until the display reads the exact pressure noted on the reference tube. 162-072012 Digital VT Page 6 of 12

2. Installation 2.1 DIGITAL VT, OUTLINE DIMENSIONS 2.2 DIGITAL VT, FRONT PANEL HASTINGS VAC ATM Torr mtorr VT 162-072012 Digital VT Page 7 of 12

2.3 DIGITAL VT, BACK PANEL 2.4 MOUNTING LAYOUT 162-072012 Digital VT Page 8 of 12

3. Vacuum Gauge Operation All Hastings gauge tubes are shipped with a protective cap or cover at the evacuation port to reduce contamination and prevent damage to the internal thermopile elements. Once the protective cap or cover is removed, a tube can be installed in any convenient position in the vacuum system without adversely affecting calibration or performance. The recommended orientation is with the tube vertical and its stem down. This will aide in preventing condensable materials from remaining in the gauge tube. 3.1 AC Input Power The Digital VT Power Supply input is rated as consuming 0.25 Amps @ 120VAC. The Power/Gauge Tube Cable is assembled at the factory as shown in Fig. 4. It requires no further wiring to be performed. To operate the Digital VT, plug the Power/Gauge Tube Cable into the connector located in the rear of the Digital VT. Connect the plug of the power supply into a single phase 100-230 VAC. 50/60 Hz power source 3.2 Quick Start 1. Plug Digital VT power supply into a 100-230 Hz outlet source. 2. Connect a DV4 or DV6 gauge tube to the Octal Socket cable assembly that is attached to the rear of the Digital VT. 3. The CPU will do a self check/initialization. The digital display should count up and stop momentarily at FFF. (Note: If the digital display shows a "- - -", this means the instrument is out of range or gauge tube is unplugged.) 4. The Torr and mtorr LED s should also momentarily illuminate. 5. After the CPU is operating, and the self check/initialization is complete, the display will indicate the output of the DV4 or DV6 tube. 6. No other operator action is required. 7. For a more accurate reading from the DV4 or DV6 tubes, refer to Section 3.7 and perform a calibration of unit. 3.3 Pressure Measurement Connect the gauge tube cable s octal socket onto the octal base of a gauge tube installed in vacuum system. The gauge will display the system pressure on the Digital VT. To check the accuracy of the gauge, perform the required operations as specified in section 3.7. 3.4 Operation and Performance The Digital VT will function right out of the box. For maximum accuracy refer to section 3.7 and perform the calibration procedure. The simplest and quickest way of checking the operation and performance of a gauge and/or gauge tube, is to keep in hand a new or known-good gauge tube on hand for use as a Reference. To check operation, install both the Reference and suspect gauge tubes in a common vacuum system (locate the gauge tubes as close as possible to each other), then evacuate the system until a stable base pressure is obtained. Alternately connect the vacuum gauge to each gauge tube and record its pressure readings. If the gauge tube-under-test produces a higher pressure reading than the Reference gauge tube, this indicates a calibration shift and is usually the result of contamination (particulate, oil, or other chemical deposits). You can try to restore calibration of the contaminated gauge tube by cleaning it internally with an appropriate solvent such as high-purity isopropyl alcohol (flood the interior cavity of gauge tube gently with solvent and 162-072012 Digital VT Page 9 of 12

allow it to stand and soak for about 15 to 30-minutes). Drain the contaminated solvent and let gauge tube dry in ambient air until all of the cleaning solvent has evaporated. To prevent mechanical damage to the thermopile elements, do not use forced air to dry the gauge tube. Gauge tubes that remain out of calibration after cleaning should be replaced. 3.5 TUBE SELECTION The Digital VT can be setup to operate with a Hastings DV4 or DV6 vacuum gauge tube. There is a jumper located on the rear panel which will select the desired tube. Normally the Digital VT will arrive from the factory configured for the tube type specified by the customer order. However if the system pressure range changes, and a different tube type will now be used, the tube type can be changed by moving the jumper position. Position the jumper over the leftmost two pins for DV-4 tubes and over the rightmost two pins for DV-6 tubes. It is recommended that the tube calibration procedure in section 3.7 be performed after changing the tube type. Note: Complete removal of the jumper will be interpreted by the internal processor as the DV6 configuration DV4 DV6 Jumper Arrangement 3.6 Gauge Tube Operating Principle Operation of the Hastings gauge tube is based on a low voltage AC bridge that heats a noble metal thermopile. A change in pressure in the gauge tube changes the molecular collision rate and therefore the thermal conduction of the gas or gas mixture surrounding the thermopile. This results in a temperature shift in the AC heated thermocouples A and B (Fig. 6). The resultant temperature shift causes a change in the DC output from couples A and B inversely with pressure changes. The DC thermocouple C (when installed) is in series with the circuit load. Thermocouple C provides compensation for transient changes in ambient temperature. 3.7 Calibration Procedure NOTE: ONCE CALIBRATION IS COMPLETE THE CALIBRATION DATA IS PERMANENTLY STORED IN NONVOLATILE MEMORY. A LOSS OF POWER WILL NOT ERASE THE CALIBRATION DATA. TO ERASE THE CALIBRATION DATA, REFER TO STEP 2. 162-072012 Digital VT Page 10 of 12

3.7.1 Preparation 1. Plug the Digital VT power supply into an outlet providing 100-230 VAC, 50/60 Hz. 2. CLEAR out any previously entered calibration data. a. Using a pointed object, such as a ballpoint pen, press and hold the ATM push button located on the front panel until CLR appears on the digital display. The ATM button must be held in the pressed position approximately 5 seconds before data is cleared and CLR is displayed. 5. Once CLR is displayed any previously entered data has been deleted. 6. Plug in DV-4 or DV-6 gage tube. Leave tube at atmospheric pressure. NOTE: TUBE MUST BE AT ATMOSPHERE TO PROPERLY SET THE HIGH END. 3.7.2 Set High End A. Press ATM push button until Set appears. The high-end setting is now set. NOTE: The LOW END can be adjusted by either bringing the system to a known vacuum or by using a HASTINGS REFERENCE TUBE. 3.7.3 Set Low End W/Vacuum System A. Set system to known vacuum. B. Turn the VAC pot on front panel until the known vacuum is displayed on digital display. (For DV-4 and/or DV-6 IF KNOWN VACUUM IS BELOW 1 mtorr SET DISPLAY TO ZERO). C. The low end is now adjusted. 3.7.4 Set Low End W/Reference Tube. A. Connect HASTINGS reference tube. B. Turn the VAC pot until the value printed on HASTINGS reference tube is displayed on digital Display. C. THE LOW END is now adjusted. NOTE: If re-calibration is required you must first repeat step 2. IF SEVERAL TUBES ARE TO BE READ AND RE-CALIBRATION FOR EACH TUBE IS NOT DESIRED, YOU MAY CLEAR THE CALIBRATION DATA (STEP 2) AND ONLY ADJUST THE LOW END SETTING ONCE. HOWEVER A LOSS OF ACCURACY WILL BE NOTICED ON THE HIGH END. Note: The following table specifies the HASTINGS reference tube to be used in the calibration of a gauge based upon the type of gauge tube being used. Ref. Tube DB-16D DB-20 Gauge Tube DV-4 DV-6 162-072012 Digital VT Page 11 of 12

4. Warranty and Repair 4.1 Warranty Repair Policy Hastings Instruments warrants this product for a period of one year from the date of shipment to be free from defects in material and workmanship. This warranty does not apply to defects or failures resulting from unauthorized modification, misuse or mishandling of the product. This warranty does not apply to batteries or other expendable parts, nor to damage caused by leaking batteries or any similar occurrence. This warranty does not apply to any instrument which has had a tamper seal removed or broken. This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty as to fitness for a particular use. Hastings Instruments shall not be liable for any indirect or consequential damages. Hastings Instruments, will, at its option, repair, replace or refund the selling price of the product if Hastings Instruments determines, in good faith, that it is defective in materials or workmanship during the warranty period. Defective instruments should be returned to Hastings Instruments, shipment prepaid, together with a written statement of the problem and a Return Material Authorization (RMA) number. Please consult the factory for your RMA number before returning any product for repair. Collect freight will not be accepted. 4.2 Non-Warranty Repair Policy Any product returned for a non-warranty repair must be accompanied by a purchase order, RMA form and a written description of the problem with the instrument. If the repair cost is higher, you will be contacted for authorization before we proceed with any repairs. If you then choose not to have the product repaired, a minimum will be charged to cover the processing and inspection. Please consult the factory for your RMA number before returning any product repair. TELEDYNE HASTINGS INSTRUMENTS 804 NEWCOMBE AVENUE HAMPTON, VIRGINIA 23669 U.S.A. ATTENTION: REPAIR DEPARTMENT TELEPHONE (757) 723-6531 1-800-950-2468 FAX (757) 723-3925 E MAIL mailto:hastings_instruments@teledyne.com INTERNET ADDRESS http://www.teledyne-hi.com/ Repair Forms may be obtained from the Information Request section of the Hastings Instruments web site. 162-072012 Digital VT Page 12 of 12