RHM 60. Coriolis Mass Flowmeter for Medium Flow also Suited for High Pressure Applications. Applications. Advantages. Features

Similar documents
RHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version

RHM The world s largest Coriolis Mass Flowmeter for flow rates up to kg/min

RHM Coriolis Mass Flowmeter for high Flow Applications

RHM 03. Flexible Coriolis Mass Flowmeter for low flow measurements. Applications. Features. Advantages

RHM 04. Universal Coriolis Mass Flowmeter with particular Fast Response. Applications. Features. Advantages

RHM 08. One of the most popular Rheonik Mass Flowmeter serving thousands of worldwide applications. Applications. Advantages.

RHM 06. One of the Most Popular Rheonik Mass Flowmeter Serving Thousands of Worldwide Applications. Applications. Advantages.

RHM 015. Ultimate Low Flow Coriolis Mass Flowmeter. Applications. Features. Advantages

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter

RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response

Ultimate Low Flow Coriolis Mass Flowmeter

Coriolis Mass Flowmeter for low flow measurements

RHM 03 a1 - (low stress in welds and increased wall thickness against abrasion) RHM bar APPLICATIONS. Batching Dosing. Injections Filling

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

RHM015. Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications. Features. Applications. Benefits

RHM04. Compact Coriolis Flow Sensor With Enhanced Performance. Features. Applications. Benefits

RHM08. Versatile Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

Rheonik Coriolis Mass Flow Meters

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Micro Motion Model D and DL Coriolis Flow and Density Meters

LIQUID CONTROLS A Unit of IDEX Corporation

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Micro Motion F-Series Coriolis Flow and Density Meters

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

OPTIMASS 3000 Technical Datasheet

SITRANS F flowmeters SITRANS F C

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

VersaFlow Coriolis 100 Mass Flow Sensor Specifications

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.

Coriolis Flow Solutions for a Global Marketplace

Metal tube variable area flowmeter for gases, liquids and steam

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

SITRANS F M. Flow sensor MAG 1100 F 3/59

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry

Coriolis Mass Flow Measuring System promass 64

Coriolis Flow Solutions for a Global Marketplace

OPTIMASS 2000 Technical Datasheet

SITRANS F C. Flow sensor MC2 4/193. Overview

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry

OPTIGAS 4010C Technical Datasheet

Flow Measurement SITRANS F M

Micro Motion 7827 Digital Viscosity Meter

Food & beverage. Oil & gas. Water & waste water

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Micro Motion F-Series Coriolis Flow and Density Meters

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

TURCK DC Insertion Flow Monitors

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

OPTIGAS 4010C Technical Datasheet

Flowmeters. The Satam flowmeter range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals.

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Micro Motion ELITE Mass Flow and Density Meters

Options guide. Electromagnetic flowmeters. M9xx

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement Point level measurement - RF Capacitance switches

KDM ARMORED FLOW METER & SWITCH

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Micro Motion ELITE Coriolis Flow and Density Meters

Coriolis Flowmeters. Coriolis Flowmeters. KCM C-flow series Coriolis mass flowmeter

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Flow Measurement SITRANS F C

ISTEC MAGNETIC METERS

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for Food & Beverage Processing

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Pneum. Buoyancy Transmitter with Torque Tube for Liquid Level, Interface and Density

SITRANS F C MASSFLO Practical examples of ordering. MASS2100 & MASS6000 IP67 Compact mounted

7330 Pro-Stik II Magnetostrictive Level System

Magnetic-inductive flow meter for hazardous areas

Flow Measurement SITRANS F C

SITRANS F M flow sensors 711/A and 711/911E

Proximity Transmitters, and Seismic Vibration Transmitters

Flow Measurement SITRANS F C

Solenoid Valves Type 3963

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

Armstrong In-Line and Insertion Vortex Flow Meters

OM004, OM006 & OM008 Oval Gear Meter

Now available with MVD Technology! ELITE Mass Flow and Density Meters

Series Level-Trol Electronic Liquid Level Transmitters

Electro-Magnetic Flowmeters Sensors MagMaster MFE

OPTISWITCH 4000/5000. Vibration level switches for liquids

Thermowell for temperature sensors omnigrad M TW 13

LCMass Series Mass Flow Sensor

Series 3730 Electropneumatic Positioner Type

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Transcription:

RHM 60 Coriolis Mass Flowmeter for Medium Flow also Suited for High Pressure Applications The RHM 60 can measure flow rates up to 180 t/hr with the patented Omega shape meter technology, manufactured by Rheonik, the mass flowmeter experts. Applications Loading of boats, vessels, rail tank wagons High temperatures and other challenging applications Highly viscous media (low pressure drop and excellent performance at low flow conditions) Features As heavy duty version available (increased wall thickness of measuring pipes for additional safety - 200 bar) Flow Accuracy of 0.1 % Repeatability better than 0.05% Patented torsion swinger Customer adaptations possible for application optimized solutions Typical measuring ranges from 30 to 3000 kg/min EEx Approvals (i.e. ATEX, CSA,...) Custody Transfer Approvals (i.e. PTB, NMI,...) Advantages Medium flow rates in combination with high operating pressure Patented torsion swinger design assures most stable and drift free measurement Increased signal to noise ratio by torsion swinger Longest life time and increased safety (low stress in welds and increased wall thickness against abrasion) No moving parts, practically no maintenance g

General The RHM 60 has been designed for medium flow rates and tough application conditions. Due to the optional heavy duty measuring pipes (up to 250 bar), this meter becomes the first choice in many applications which have medium flow rates with high operating presssure. This unique design, which offers excellent performance and reliability, has created the most satisfied customers worlwide. Unlike other mass flowmeter manufacturers, Rheonik uses a patented torsion rod swinger with the Omega shape and support bars which results in high accuracy measurement, which is independent of pressure, even at very low flow velocities. The meter also has extremely good repeatability and high stability for critical applications.

RHM 60 Specifications Performance RHM 60 Max Flow 3000 kg/min (6610 lb/min) Standard Models Rates/turndown ratio in (kg/min) in (lb/min) error in % of reading nominal rate Q nax 2500 5512 0.20 0.2 * Q max (5:1) 600 1320 0.20 0.1 * Q max (10:1) 300 661 0.20 0.05 *Q max (20:1) 150 330 0.20 0.02 *Q max (50:1) 60 132 0.50 Typical P in bar (psi) Rates/turndown ratio in (kg/min) in (lb/min) 1 cp 100 cp 1000 cp 0.6 (8.3) 1.2 (18.3) 3.9 (56) ~ 0 (0.6) 0.1 (1.4) 0.9 (13) ~ 0 (0.1) ~ 0.1 (0.7) 0.5 (6) ~ 0 (0) ~ 0 (0.3) 0.2 (3) ~ 0 (0) ~ 0 (0.1 ) ~ 0.1 (1) Optimized Low Flow Models (*) /optimized to be operated between 0.0135 x Q max and 0.27 x Q max 0.27* Q max (1:1) 800 1763 0.1 2 0.027* Q max (10:1) 80 176 0.15 0.0135* Q max (20:1) 40 88 ~ 0.50 (**) (*) serial/single path version offers the same accuracy at half the flow (Q max = 1500 kg/min) (**) around 0.30-0.70 % accuracy depending on the installation conditions ~ 0.1 (1.0) ~ 0.2 (2.0) 1.2 (17) ~ 0 (0) ~ 0 (0.2) ~ 0.1 (2) ~ 0 (0) ~ 0 (0.1) ~ 0.1 (1) Gold Line Models/application fine tuned meters 1 * Q nom (1:1) 2500 5512 0.10 0.1 * Q nom (10:1) 500 1102 0.12 0.05 * Q nom (20:1) 250 551 0.15 0.6 (8.3) 1.2 (18.3) 3.9 (56) ~ 0 (0.4) ~ 0.1 (1.2) 0.8 (11) ~ 0 (0.1) ~ 0 (0.6) 0.4 (5) Repeatability Better ± 0.05% of rate Density Better than ± 0.0015 g/cc - Gold Line: Field adjustable to better ± 0.001 g/cc Temperature Better ± 1 C Standard Models Gold Line Models For serial (single pipe/path) sanitary design Qmax is 375 kg/min (50%). Data above to standard wall thickness. Error of reading (including zero drift) indications refer to reference conditions H2O, 18 C to 24 C (66 F to 76 F), 1 bar to 3 bar (15 psi to 45 psi). RHM sensor do not suffer from pressure effect due to torsional oscillation and semi circle (non-deforming) measurement section. Temperature changes of +/- 25 C around the operating point are negligible. Pressure drop refers to Newton liquids, with parallel measuring loops and block/manifold connection. Nominal flow refers to approx. 10 m/s (33 ft/sec) velocity in measuring loops for best performance. Calibration to customer range, with increased accuracy, possible.

General Dimensions RHM 60 Type II (sealless welded parallel measuring loops w/o seallings [PF0]) A1 = 910 mm (35.83 in) A2 = 950 mm (37.40 in) B1 = 150 mm (5.91 in) B2 = 230 mm (9.06 in) H1 = 1253 mm (49.33 in) H2 = 1443 mm (56.81 in) E = 300 mm (11.81 in) W = 150 mm (5.91 in) Weight approx. 200 kg (440 lb) Shipping Box approx. 180 cm x 120 cm x 75 cm (71 in x 48 in x 30 in) Type III (sealless welded serial measuring loops w/o seallings [SF0]) Process Connection Face to face length L (*) Order Code Standard Optional Special 4 in CL 150 acc. ANSI B16.5 725 mm (28.54 in) F1 4 in CL 300 acc. ANSI B16.5 725 mm (28.54 in) F2 4 in CL 600 acc. ANSI B16.5 725 mm (28.54 in) F3 DN100/PN40 acc. DIN 2527 - C 725 mm (28.54 in) C1 DN100/PN100 acc. DIN 2527 - E 725 mm (28.54 in) C2 4 in CL 900 acc. ANSI B16.5 900 mm (35.43 in) A9 4 in CL 1500 acc. ANSI B16.5 900 mm (35.43 in) XX DN100/PN160 acc. DIN 2527 - E 900 mm (35.43 in) D3 DN100/PN250 acc. DIN 2527 - E 900 mm (35.43 in) XX Different sized flanges please consult factory XX (*) Customization possible on request. The finish type of our ANSI flanges is RF/SF (AARH 125-250 (μinch) - Ra 3, 2 up to 6, 3 (μm)). Others available on request. Above table only shows our general process fittings. For further customization with regard to special fittings and face to face length please contact your local agent. A1 = 910 mm (35.83 in) A2 = 950 mm (37.40 in) B1 = 150 mm (5.91 in) B2 = 230 mm (9.06 in) H1 = 1250 mm (49.21 in) H2 = 1385 mm (54.53 in) E = 300 mm (11.81 in) W = 150 mm (5.91 in) V = 96 mm (3.78 in) Weight approx. 200 kg (440 lb) Shipping Box approx. 180 cm x 120 cm x 75 cm (71 in x 48 in x 30 in) Process Connection Face to face length L (*) Order Code Sanitary 2 in Tri Clamp 500 mm (19.68 in) S1 Fittings (**) DN50/Sanitary acc. DIN 11851 400 mm (15.74 in) S2 3 in CL 150 acc. ANSI B16.5 400 mm (15.75 in) A1 3 in CL 300 acc. ANSI B16.5 400 mm (15.75 in) A2 Optional DN80/PN40 acc. DIN 2527 - C 400 mm (15.75 in) D1 Different sized flanges please consult factory XX (*) Customization possible on request. (**) The finish type of our ANSI flanges is RF/SF (AARH 125-250 (μinch) - Ra 3, 2 up to 6, 3 (μm)). Others available on request. Above table only shows our general process fittings. For further customization with regard to special fittings and face to face length please contact your local agent.

General Specifications RHM 60 Approvals ATEX (CESI 02 ATEX 053 X): Ex II 1 G, EEx ia IIC T6-T1 CSA (220705) Class I, Div 1 and 2, Groups A, B, C and D;Type 3 Custody Transfer Approvals (PTB 1.32-97027224 and NMI TC 3382) PED according to directive 97/23/EC available 3A Sanitary Approvals Electrical Connection Junction box/aluminium coated (standard) IP 65 (Nema 4X) (Junction box in SS optional) Cable entry M25 x 1.5 (M20 x 1.5, ½ in and ¾ in NPT optional) Max cable length between RHM and RHE: 100 m (330 ft) 200 m (660 ft) only with factory approval Housing Stainless Steel: 1.4301/SS 304 - other optional - Protection class: IP 65 (NEMA 4X) - higher on request - Material of Wetted Parts 1.4571/SS 316Ti (standard) 1.4539/SS 904L on request Hastelloy C22 on request Other material on request Pressure Rating Pressured part of the meter consists of the measuring loops and the connection part. The weaker of both parts decides the maximum allowed operating pressure. Below is the max. operating pressure of the measuring loops(*). (*) These values are only valid for SS 316Ti & SS 904L materials. Statements for others materials on request. Standard version: 100 bar @ 120 C (1450 psi @ 248 F) 90 bar @ 210 C (1305 psi @ 410 F) 80 bar @ 350 C (1160 psi @ 662 F) wall thickness is generally 2.9 mm (0.11 in) Optional high pressure version: 200 bar @ 120 C (2900 psi @ 248 F) wall thickness is generally 5.5 mm (0.21 in) Other pressure version - on request - Material of Wetted Parts NT Models from -20 C to 120 C (-4 F to 248 F) ET Models from -45 C to 120 C (-49 F to 248 F) ET1 Models from -200 C to 50 C (-328 F to 122 F) ET2 Models from -45 C to 210 C (-49 F to 410 C) HT Models from 0 C to 350 C (32 F to +662 F)

Order Code RHM 60 Order Code Structure The order code of the Rheonik Sensors consists of 6 sections (see previous pages / below). Restrictions of combinations may apply. For specials, please comment your needs in plain text / sketches. Temperature Rating T1 NT Models (Normal Temperature Models) from -20 C to 120 C (-4 F to 248 F) TA ET Models (Extended Temperature Models) from -45 C to 120 C (-49 F to 248 F) T2 ET2 Models (Extended Temperature Models) from -45 C to 210 C (-49 F to 410 F) T3 ET1 Models (Extended Temperature Models) from -200 C to 50 C (-328 F to 122 F) T4 HT Models (High Temperature Models) from 0 C to 350 C (32 F to 662 F) Pressure Rating P1 Standard pressure version (100 bar @ 120 C/1450 psi @ 248 F) - page 5 P2 High pressure version (200 bar 120 C / 2900 psi @ 248 F) - page 5 PX Other pressure version (on request) - page 4 Construction Type PM0 Parallel Measuring Loops with removable Block/Manifold and PTFE Seals - page 3 PF0 Parallel Measuring Loops Seal Less Welded Version - page 3 SF0 Serial Measuring Loops Seal Less Welded Version/Single Path - page 5 XXX Other construction type on request Material of Wetted Parts M1 1.4571/SS 316Ti M2 1.4539/SS 904L M3 Hastelloy C22 Process Connection XX Code available on pages 3, and 4. Hazardous Area Approvals NN Without Ex Approvals AT ATEX Approvals (CESI 02 ATEX 053 X) - Ex II 1 G, EEx ia IIC T6-T1 CS CSA Approvals (220705) - Class 1, Div 1/Group A, B, C, and D; Type 3 - - - - - Order Code Example M#60 T1 P1 PM0 M1 D1 AT T1: NT (Normal Temperature Models) from -20 C to +120 C (-49 F to 248 F) P1: P1 : Standard pressure version (140 bar @ 120 C/2030 psi @ 248 F) PFO: Parallel Measuring Loops Seal Less Welded Version M1: 1.4571 / SS 316 Ti A1: 4 CL 150 acc. ANSI B 16.5 AT: ATEX Approvals (CESI 02 ATEX 053 X) M #60 - - - - - -

www.gesensinginspection.com 920-000-1 2008 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.