RHM 03. Flexible Coriolis Mass Flowmeter for low flow measurements. Applications. Features. Advantages

Similar documents
RHM 04. Universal Coriolis Mass Flowmeter with particular Fast Response. Applications. Features. Advantages

RHM 08. One of the most popular Rheonik Mass Flowmeter serving thousands of worldwide applications. Applications. Advantages.

RHM 06. One of the Most Popular Rheonik Mass Flowmeter Serving Thousands of Worldwide Applications. Applications. Advantages.

RHM 015. Ultimate Low Flow Coriolis Mass Flowmeter. Applications. Features. Advantages

RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter

Ultimate Low Flow Coriolis Mass Flowmeter

RHM 60. Coriolis Mass Flowmeter for Medium Flow also Suited for High Pressure Applications. Applications. Advantages. Features

Coriolis Mass Flowmeter for low flow measurements

RHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version

RHM The world s largest Coriolis Mass Flowmeter for flow rates up to kg/min

RHM Coriolis Mass Flowmeter for high Flow Applications

RHM 03 a1 - (low stress in welds and increased wall thickness against abrasion) RHM bar APPLICATIONS. Batching Dosing. Injections Filling

RHM08. Versatile Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM04. Compact Coriolis Flow Sensor With Enhanced Performance. Features. Applications. Benefits

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

RHM015. Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications. Features. Applications. Benefits

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

Rheonik Coriolis Mass Flow Meters

Micro Motion Model D and DL Coriolis Flow and Density Meters

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Micro Motion F-Series Coriolis Flow and Density Meters

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Options guide. Electromagnetic flowmeters. M9xx

OPTIMASS 3000 Technical Datasheet

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

LIQUID CONTROLS A Unit of IDEX Corporation

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

OPTIMASS 2000 Technical Datasheet

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry

VersaFlow Coriolis 100 Mass Flow Sensor Specifications

SITRANS F M. Flow sensor MAG 1100 F 3/59

OPTIGAS 4010C Technical Datasheet

Micro Motion F-Series Coriolis Flow and Density Meters

Micro Motion ELITE Coriolis Flow and Density Meters

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

SITRANS F flowmeters SITRANS F C

OPTIGAS 4010C Technical Datasheet

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for Food & Beverage Processing

Flow Measurement SITRANS F M

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Coriolis Flow Solutions for a Global Marketplace

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Coriolis Mass Flow Measuring System promass 64

Flow Measurement SITRANS F C

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

Coriolis Flow Solutions for a Global Marketplace

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Flow Measurement SITRANS F C

Micro Motion 7827 Digital Viscosity Meter

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Micro Motion ELITE Mass Flow and Density Meters

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

ISTEC MAGNETIC METERS

SITRANS F C. Flow sensor MC2 4/193. Overview

Food & beverage. Oil & gas. Water & waste water

Level Measurement Point level measurement - RF Capacitance switches

Applications. T h e C o r i o l i s E x p e r t s

Magnetic-inductive flow meter for hazardous areas

Metal tube variable area flowmeter for gases, liquids and steam

OM004, OM006 & OM008 Oval Gear Meter

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

OPTIFLUX 6000 Technical Datasheet

Technical Data Sheet PS , Rev C May Micro Motion R-Series Coriolis Flow and Density Meters

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

VersaFlow Vortex 100 Vortex Flow Meter Specifications

LCMass Series Mass Flow Sensor

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Differential Pressure Gauges (701P Series)

TURCK DC Insertion Flow Monitors

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

OPTISWITCH 4000/5000. Vibration level switches for liquids

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Flow Measurement SITRANS F M

Pressure Transmitters

Micro Motion F-Series Flow and Density Meters

Flowmeters. The Satam flowmeter range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals.

Coriolis Flowmeters. Coriolis Flowmeters. KCM C-flow series Coriolis mass flowmeter

KDM ARMORED FLOW METER & SWITCH

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

JUMO dtrans p20 DELTA

TORRIX Magnetostrictive level sensor

SITRANS F M flow sensors 711/A and 711/911E

Now available with MVD Technology! ELITE Mass Flow and Density Meters

Micro Motion T-Series Coriolis Flow and Density Meters

Transcription:

RHM 03 Flexible Coriolis Mass Flowmeter for low flow measurements The RHM 03 can measure flow rates up to 5 kg/min (11 lb/min) with temperatures in excess of 400 C and pressures to 868 bar. This model is a truly unique flexible solution, manufactured by Rheonik, the mass flowmeter experts. Applications Suitable for virtually any mass flow application, such as: General flow control Dosing Batching Injections Filling Features The outstanding features include: Suitable for pressure up to 868 bar Typical measuring ranges from 0.05 kg/min to 5 kg/min (11 lb/min) Minimal flows as low as 0.0375 kg/min Patented Torsion Swinger Optimised solutions Flow Accuracy of 0.10% Repeatability better than 0.05% Many different material and fittings available Extra compact design with minimal space requirement EEx Approvals (i.e. ATEX, CSA,...) Custody Transfer Approvals (i.e. PTB, NMI,...) Advantages No pressure effect no deterioration of accuracy due to pressure changes by the patented Omega Shape Patented torsion swinger design assures longest life time and increased safety (low stress in welds and increased wall thickness against abrasion) No moving parts practically no maintenance Removable connection block g

General The RHM 03 is an economical meter which has been in production over 15 years. This meter is available in a wide variety of models which makes it suitable for virtually all applications. As with all other Rheonik meters, this model is based on the patented Omega tube design with increased signal to noise ratio. This unique design, which offers excellent performance and reliability, has created the most satisfied customers worldwide. Unlike other mass flowmeter manufacturers, Rheonik uses a patented torsion rod swinger with the Omega shape and support bars which results in high accuracy measurement, which is independent of pressure, even at very low flow velocities. The meter has also extremely good repeatability and high stability for critical applications.

RHM 03 Specifications Performance RHM 03 Max Flow 5 kg/min (11 lb/min) Standard Models Rates/turndown ratio in (kg/min) in (lb/min) error in % of reading nominal rate Q nom 5.000 11.03 0.15 0.2 * Q max (5:1) 1.000 2.21 0.20 0.1 * Q max (10:1) 0.500 1.10 0.20 0.05 * Q max (20:1) 0.250 0.55 0.20 0.02 * Q max (50:1) 0.100 0.22 0.50 Typical P in bar (psi) 1 cp 100 cp 1.4 (20) 14.7 (213) 0.1 (1.5) 2.9 (42.1) ~ 0 (0.2) 1.5 (21.8) ~ 0 (0.1) 0.8 (11.6) ~ 0 (0) 0.3 (4.4) Optimized Low Flow Models (*) /optimized to be operated between 0.015 x Q max and 0.3 x Q max Rates/turndown ratio in (kg/min) in (lb/min) error in % of reading 0.3 * Q max (1:1) 1.500 3.30 0.15 0.02 * Q max (15:1) 0.100 0.22 0.20 0.015 * Q max (20:1) 0.075 0.17 ~ 0.50 (**) (*) serial/single path version offers the same accuracy at half the flow (Q max = 2.5 kg/min) (**) around 0.30-0.70 % accuracy depending on the installation conditions 0.2 (2.3) 4.4 (63.5) ~ 0 (0) 0.3 (4.4) ~ 0 (0) 0.2 (3.1) Gold Line Models/application fine tuned meters 1 * Q nom (1:1) 5.000 11.03 0.10 0.1 * Q nom (10:1) 0.500 0.55 0.10 0.05 * Q nom (20:1) 0.250 0.22 0.12 1.4 (20) 14.7 (213) ~ 0 (0.1) 0.8 (11.6) ~ 0 (0) 0.3 (4.4) Repeatability better ± 0.05 % of rate Temperature Better ± 1 C Standard Models Gold Line Models For serial (single pipe/path) sanitary design Qmax is 2.5 kg/min (50%). Data above refer to standard wall thickness. Error of reading (including zero drift) indications refer to reference conditions H2O, 18-24 C (66-76 F), 1-3 bar (15-45 psi). RHM sensor do not suffer from pressure effect due to torsional oscillation and semi circle (non-deforming) measurement section. Temperature changes of +/- 25 C around the operating point are negligible. Pressure drop refers to Newton liquids, with parallel measuring loops and block/manifold connection. Nominal flow refers to approx. 10 m/s (33 ft/sec) velocity in measuring loops for best performance. Calibration to customer range, with increased accuracy, possible.

General Outline Dimensions RHM 03 Type I (w/removable manifold block - serial [SM0]/parallel [PM0]/PTFE seals) Thread Type: Flange Type: Weight approx. 2.5 kg (5.5 lb) Weight approx. 3.5 kg (7.7 lb) A1=130 mm (5.12 in) B1=25 mm (0.98 in) H1=172 mm (6.77 in) A2=145 mm (5.71 in) B2=40 mm (1.57 in) H2=188 mm (7.40 in) H2=196.5 mm (7.74 in) for brazed block version W = 0 mm for standard temperature models -45/-20 C to 120 C (-49/-4 F to 248 F) = 100 mm (3.96 ) for extended (ET1, ET2) and high temperature models(*) Process Connection Face to Face Length (L) (**) Order Code Thread Standard Thread Optional G ¼ in female 50 mm (1.97 in) G1 NPT ¼ in female 50 mm (1.97 in) N1 Autoclave/Butech thread 70 mm (2.76 in) P1 M20 x 1.5 70 mm (2.76 in) XX Flange Standard Flange Optional Special ½ in CL 150 acc. ANSI B16.5 220 mm (8.67 in) A1 ½ in CL 300 acc. ANSI B16.5 220 mm (8.67 in) A2 ½ in CL 600 acc. ANSI B16.5 220 mm (8.67 in) A3 DN15/PN40 acc. DIN 2635 - C 220 mm (8.67 in) D1 DN15/PN100 acc. DIN 2637 - E 220 mm (8.67 in) D2 ½ in CL 900/1500 acc. ANSI B16.5 300 mm (11.82 in) A6 DN15/PN160 acc. DIN 2638 - E 220 mm (8.67 in) D3 ½ in JIS flanges standard - 220 mm (8.67 in) XX Swagelok standard - 190 mm (7.48 in) XX VCR standard - 190 mm (7.48 in) XX Novaswiss standard - 190 mm (7.48 in) XX (*) Type II or Type III preferred - see next pages. (**) Customization possible on request. Our standard seals are PTFE - Manifold block on request available without seals but with brazed connection block. The finish type of our ANSI flanges is RF/SF (AARH 125-250 (μ in) - Ra 3,2 up to 6,3 (μm)). Others available on request. Above table only shows our general process fittings. For further customization with regard to face to face length and special fittings please contact your local agent.

General Outline Dimensions RHM 03 Type II (sealless welded, parallel measuring loops w/o seals [PF_]) Flange Type: Special Fittings: Weight approx. 3.5 kg (7.7 lb) Weight approx. 3.5 kg (7.7 lb) A1=130 mm (5.12 in) B1=25 mm (0.98 in) H1=172 mm (6.77 in) A2=145 mm (5.71 in) B2=40 mm (1.57 in) H2=205 mm (8.07 in) W = 0 mm for standard temperature models -45/-20 C to 120 C (-49/-4 F to 248 F) and W = 100 mm (3.96 ) for extended (ET1, ET2) and high temperature models Process Connection Face to Face Length (L) (**) Order Code ½ in CL 150 acc. ANSI B16.5 220 mm (8.67 in) A1 ½ in CL 300 acc. ANSI B16.5 220 mm (8.67 in) A2 Standard Optional Special ½ in CL 600 acc. ANSI B16.5 220 mm (8.67 in) A3 DN15/PN40 acc. DIN 2527 - C 220 mm (8.67 in) D1 DN15/PN100 acc. DIN 2527 - E 220 mm (8.67 in) D2 ½ in CL 900/1500 acc. ANSI 300 mm (11.82 in) A6 B16.5 ½ in/cl 2500 acc. ANSI B16.5 300 mm (11.82 in) A8 DN15/PN160 acc. DIN 2527 - E 220 mm (8.67 in) D3 G ¼ in female standard - 220 mm (8.67 in) G1 NPT ¼ in female standard - 220 mm (8.67 in) N1 Swagelok ¼ in tube inlet standard - 300 mm (11.82 in) W1 (SS-400-1-4W) ½ in JIS flanges standard - 220 mm (8.67 in) XX Free pipe ends 12.00 x 1.50 mm standard - 190 mm (7.48 in) XX Grayloc or equivalent hubb standard - 190 mm (7.48 in) XX (*) Customization possible on request. The finish type of our ANSI flanges is RF/SF (AARH 125-250 (μinch) - Ra 3,2 up to 6,3 (μm)). Others available on request. Above table only shows our general process fittings. For further customization with regard to special fittings and face to face length please contact your local agent.

General Outline Dimensions RHM 03 Type III (sealless welded, serial measuring loops - single path w/o seals [SF_]) Sanitary Fittings: Flange/Other Fittings: Weight approx. 3 kg (6.6 lb) Weight approx. 3.5 kg (7.7 lb) A1=130 mm (5.12 in) B1=25 mm (0.98 in) H1=172 mm (6.77 in) A2=145 mm (5.71 in) B2=40 mm (1.57 in) H2=184 mm (7.25 in) for sanitary fittings H2=205 mm (8.07 in) for flange type W = 0 mm for standard temperature models -45/-20 C to 120 C (-49/-4 F to 248 F) and W = 100 mm (3.96 ) for extended (ET1, ET2) and high temperature models Process Connection Face to Face Length (L) (*) Order Code Sanitary Fittings (**) ½ in Tri Clamp acc. DIN 32676 220 mm (8.67 in) S1 DN10/Sanitary acc. DIN 11851 220 mm (8.67 in) S2 ½ in CL 150 acc. ANSI B16.5 220 mm (8.67 in) A1 ½ in CL 300 acc. ANSI B16.5 220 mm (8.67 in) A2 Flange Other Fittings DN15/PN40 acc. DIN 2527 - C 220 mm (8.67 in) D1 G ¼ in female 220 mm (8.67 in) G1 NPT ¼ in female 220 mm (8.67 in) N1 Swagelok ¼ in tube inlet (SS- 400-1-4W) standard - 300 mm (11.82 in) W1 Free pipe ends 12.00 x 1.50 mm standard - 220 mm (8.67 in) XX (*) Customization possible on request. (**) Fitting material is 1.4435/SS 316L (Tri Clamp acc. DIN 32676) and 1.4301/SS 304 (Sanitary connection acc. DIN 11851). The finish type of our ANSI flanges is RF/SF (AARH 125-250 (μinch) - Ra 3,2 up to 6,3 (μm)). Others available on request. Above table only shows our general process fittings. For further customization with regard to special fittings and face to face length please contact your local agent.

General Specifications RHM 03 Approvals ATEX (CESI 02 ATEX 053 X): Ex II 1 G, EEx ia IIC T6-T1 CSA (220705) Class I, Div 1 and 2, Groups A, B, C and D; Type 3 Custody Transfer Approvals (PTB 1.32-97027224 and NMI TC 3382) PED according to directive 97/23/EC available 3A Sanitary Approvals Electrical Connection Junction box/aluminium coated (standard) IP 65 (Nema 4X) (Junction box in SS optional) Cable entry M25 x 1.5 (M20 x 1.5, ½ in and ¾ in NPT optional) Max cable length between RHM and RHE: 100 m (330 ft) 200 m (660 ft) only with factory approval Housing Stainless Steel: 1.4301/SS 304 - others on request - Protection class: IP 65 (Nema 4X) - higher on request - Material of Wetted Parts 1.4539/SS 904L (measuring loops) 1.4571/SS 316Ti (process connection) Hastelloy C22 on request Tantalum on request Other material on request Pressure Rating Pressured part of the meter consists of the measuring loops and the connection part. The weaker of both parts decides the maximum allowed operating pressure. Below is the max. operating pressure of the measuring loops(*). (*) These values are only valid for SS 316Ti & SS 904L materials. Statements for others materials on request. Standard Version: 300 bar @ 120 C (4350 psi @ 248 F) 250 bar @ 210 C (3625 psi @ 410 F) 200 bar @ 350 C (2900 psi @ 662 F) wall thickness is generally 0.4 mm (0.016 ) Optional low Pressure loss Version: 200 bar @ 120 C (2900 psi @ 248 F) wall thickness is generally 0.3 mm (0.012 in) Optional extremely low Pressure loss Version: 150 bar @ 120 C (2175 psi @ 248 F) wall thickness is generally 0.2 mm (0.008 in) Extremely high pressure (up to 800 bar) - on request - Teperature Rating NT Models from -20 C to 120 C (-4 F to 248 F) ET Models from -45 C to 120 C (-49 F to 248 F) ET1 Models from -200 C to 50 C (-328 F to 122 F) ET2 Models from -45 C to 210 C (-49 F to 410 F) HT Models from 0 C to 350 C (32 F to 662 F)

Order Code RHM 03 Order Code Structure The order code of the Rheonik Sensors consists of 6 sections (see previous pages/below). Restrictions of combinations may apply. For specials, please comment your needs in plain text/sketches. RHM 03 Temperature Rating T1 NT Models (Normal Temperature Models) from -20 C to 120 C (-4 F to 248 F) TA ET Models (Extended Temperature Models) from -45 C to 120 C (-49 F to 248 F) T2 ET2 Models (Extended Temperature Models) from -45 C to 210 C (-49 F to 410 F) T3 ET1 Models (Extended Temperature Models) from -200 C to 50 C (-328 F to 122 F) T4 HT Models (High Temperature Models) from 0 C to 350 C (32 F to 662 F) Pressure Rating P1 Extremely low pressure loss version (150 bar @ 120 C/2175 psi @ 248 F) - page 6 - PA Low pressure loss version (200 bar @ 120 C/2900 psi @ 248 F) - page 6 - P2 Standard pressure version (300 bar 120 C/4350 psi @ 248 F) - page 6 - PX Extremely high pressure version (on request) - page 6 - Construction Type PM0 Parallel Measuring Loops with removable Block/Manifold and PTFE Seals - page 3 - SM0 Serial Measuring Loops with removable Block/Manifold and PTFE Seals - page 3 - PF_ Parallel Measuring Loops Seal Less Welded Version - page 4 - SF_ Serial Measuring Loops Seal Less Welded Version/Single Path - page 5 - XXX Other construction type on request Material of Wetted Parts M0 1.4539/SS 904L (measuring loops) 1.4571/SS 316Ti (connection part) M3 Hastelloy C22 M4 Tantalum MX Other material on request Process Connection XX Code available on pages 3, 4 and 5. Hazardous Area Approvals NN Without Ex Approvals AT ATEX Approvals (CESI 02 ATEX 053 X) - Ex II 1 G, EEx ia IIC T6-T1 CS CSA Approvals (220705) - Class 1, Div 1/Group A, B, C, and D; Type 3 RHM 03 - - - - - Order Code Example M#03 T1 P2 PM0 M0 G1 AT T1: NT (Normal Temperature Models) from -20 C to 120 C (-49 F to 248 F) P2: Standard pressure version (300 bar @ 120 C/4350 psi @ 248 F) PM0: Parallel Measuring Loops with removable Block/Manifold and PTFE Seals M0: 1.4539/SS 904L (measuring loops) 1.4571/SS 316Ti (connection part) G1: Female Thread G ¼ in AT: ATEX Approvals (CESI 02 ATEX 053 X) M #03 - - - - - - g www.gesensinginspection.com 920-000-01 2008 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.