Classification report No K1

Similar documents
Test report no

Test report No

Test report No

Test report no

Test report No

Test Report No

Test report No

Test report No

European B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd

Test report No

Germany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7

Test report no

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

Oxygen Bomb Calorimeter

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

Catalogue Partition rooms flexibly. Protect personal privacy. Curtains. Screen Systems

FIRE TEST REPORT FH 5154

Report Test Report

PRODUCT INFORMATION RENOLIN DTA. Lubricating and hydraulic oils. Description. Advantages. Application. Specifications

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Translation from the German original, not verified by the Deutsches Institut für Bautechnik. Zulassungsstelle für Bauprodukte und Bauarten

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

Evidence of performance Reduction of impact sound pressure level by floor coverings

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Fully synthetic refrigeration oils based on special polyglycols (PAG) for R134a A/C systems. Advantages

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Flexible insulation to prevent condensation and energy losses

Test Report /Al (Results with Batch 1) Vastern Timber Company Ltd. Wootton Bassett, Swindon

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen

Designed to prevent condensation and energy losses

DEUTSCHE NORM DIN 8077

Evidence of Performance Airborne sound insulation of flat roofs

Determination Of Fire Effluents From Products On Railway Vehicles

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

TEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5

oééçêí=çå=cáåçáåöë= OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018

FIRE TEST REPORT FH 5728

FIRE TEST REPORT FH 5078

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

RENOLIN Xtreme Temp Plus

DÜRR NDT GmbH & CO. KG Höpfigheimer Straße Bietigheim-Bissingen

ISO :2015/DAM 1

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

Sound-absorbing spacer Sorp10

SIGMACOVER 805. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2013) DESCRIPTION

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Inspection Report. Coating name: IGP HWFclassic IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number:

BRILEX Venting Solutions

Certificate: / 22 March 2013

RENOSAFE FireProtect 46, 68 Fire resistant hydraulic fluid, based on new ester and additive technology, Type HFDU

MITRAS MATERIALS GMBH

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

DEUTSCHE NORM DIN Passverzahnungen mit Evolventenflanken und Bezugsdurchmesser Teil 2: Nennmaße und Prüfmaße

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

FORM 20 (See Rule 47)

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Fire tests with textile membranes on the market - results and method development of cone calorimeter and SBI test methods

Test report No.: VU

RENEP CGLP. High-performance slideway oils for machine tools, with excellent demulsification properties. Description. Advantages

VAUTH ANALYSING. TESTING. CERTIFYING. aviation components

FIRE ASSESSMENT REPORT FAR 4659

RENISO K. Special naphthenic refrigeration oils. Description. Advantages. Application. Specifications

Ein Unternehmen der SCHAUENBURG International Gruppe Fire sleeve - F 88 SC Technical data Product details

SIGMAZINC 68 SP / AMERCOAT 68 SP

13 th December Title: The Fire Resistance Performance Of Doorsets When Fitted With Perko Powermatic R100 Jamb Mounted Concealed Door Closers

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

Confirmation: / 22 March 2013

TYPE-CERTIFICATE DATA SHEET

TECHNICAL INFORMATION

5-Layer Hot & Cold Water Piping

PRODUCT EVALUATION REPORT

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

Vertex Floors Ltd. Room B & C, 15/f Hang Seng Causeway Bay Building, 28 Yee Wo Street, Causeway Bay. P.R. China. Berlin, den

PERFORMANCE CHARACTERISTICS ANTIQUE VINYL FLOORING

Synthetic EP air compressor oils based on PAO, for turbo, screw, vane and piston compressors; High-performance synthetic, PAO-based hydraulic fluids

CABLE CLAMPS FOR LOW AND HIGH VOLTAGE CABLES

EC type-examination of SITEMA Safety Brakes by DGUV Test

Title: WF Report No:

ENERGY. Solar Cables

Approval of SITEMA Safety Catchers for use as a mechanical restraint device in presses.

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

No carcinogenic nitrosamine generating raw materials are used.

Stationary piston compressors RECOM

PAB Atex-certified centrifugal pumps

Product Information. Bayferrox 610. Description. Specification. Specification. Brown pigment

Polymeric membrane for roof waterproofing. Uses Roof waterproofing membrane for exposed flat roofs: Loose laid and mechanically fastened

PUR-O-STOP FS-L. General Building Inspectorate Approval for curtain grouting CE-marking in accordance with EN

Guidelines for the application of EN to electrical and electronic insulating materials

KAIFLEX PRODUCT BROCHURE

ASTM E 1354 Caloric Content Determination of "3M Polyurethane Adhesive Sealant 540"

Transcription:

Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Classification report No. 2017-1319-K1 issued 03.04.2017 Applicant: SIMONA AG Teichweg 16 55606 Kirn Order: Classification of the burning behaviour according to DIN EN 13501-1 (2010-01) Date of order 30.11.2016 and 22.03.2017 Notification number of the test laboratory NB 1378 Designation of the classificated building product Simona Simopor Light Billiant This classification report lays down the classification of the building product above according to the procedures of DIN EN 13501-1. The classification report are only allowed to be published or reproduced, not changed in form and tenor without permission of the Exova Warringtonfire, Frankfurt The abridged account of a classification report is only allowed with the agreement of the Exova Warringtonfire, Frankfurt. This classification report is a translation of the German version 2017-1319-K1 (issued 03.04.2017). In case of doubt only the German version is valid. This classification report contains 5 pages. Registered Office: Exova GmbH, Industriepark Höchst, C369, Frankfurt, D-65926, Registered Company No. HRB 83049 Ust-Id Nr. DE259957713

Classification report No. 2017-1319-K1 issued 03.04.2017 page 2 of 5 1. Description of the material 1.1 Details of the customer: Trade name: Sample material: Total thickness: Total surface weight: Colour: Test surface : Intended usage area: Simona Simopor Light Brilliant PVC foamed hard 2 mm and 10 mm 1,1 kg/m² and 5,5 kg/m² white Both sides equal Construction, advertising, trade fair construction 1.2 At the specimen preparation from the Exova Warringtonfire determined values: Panel material Sample no. Kind of material: Colour: Total thicknesss: [mm] Surface weight: [kg/m²] 1 Simona Simopor Light Brilliant white 1,98 1,09 2 Simona Simopor Light Brilliant white 9,88 4,31 3 Simona Simopor Light Brilliant white 9,88 4,31 4 Simona Simopor Light Brilliant white 9,88 4,31 Red protective film is deducted for the test. Material construction und fixing see pictures below: picture: edge of the large sample wing fixing of specimen

Classification report No. 2017-1319-K1 issued 03.04.2017 page 3 of 5 1.3 Production and pretreatment of the samples for the tests according to DIN EN 13823 The samples were provided for the tests in the necessary sample dimensions, by the applicant. The material was bolted for the test on a calcium silicate plate (12 mm thickness) and was tested without any distance to the plasterboard substrate in accordance with DIN EN 13823, Point 4.4.10 (calcium silicate, gross density 800 ± 150 kg/m³, thickness 12 ± 3 mm). All samples were tested in the same assembly. The samples were conditioned to constant mass for more then 48h according to DIN EN 13238 (June 2010). 1.4 Production and pretreatment of the samples for the tests according to DIN EN 11925-2 The samples were provided for the tests in the necessary sample dimensions, by the applicant. The samples were conditioned to constant mass for more then 48h according to DIN EN 13238 (June 2010).

Classification report No. 2017-1319-K1 issued 03.04.2017 page 4 of 5 2. Test reports and test results 2.1 Test reports Name of test laboratory Customer Report to form the basis Test procedure DIN EN 13823 (SBI) Exova Warringtonfire, Frankfurt SIMONA AG 2017-1319 EN ISO 11925-2 (30s ignition time surface and edge ignition) 2.2 Test results Test procedures Parameter / classes Test results average DIN EN 13823 (SBI) DIN EN ISO 30s 11925-2 15s (surface and edge) FIGRA 0,2MJ 120 [W/s] for class A2 FIGRA 0,2MJ 120 [W/s] for class B FIGRA 0,4MJ 250 [W/s] for class C FIGRA 0,4MJ 750 [W/s] for class D THR 600s [MJ] 7,5 MJ for class A2 THR 600s [MJ] 7,5 MJ for class B THR 600s [MJ] 15 MJ for class C THR 600s [MJ] no requirement for class D SMOGRA-index 30 [m²/s²] für s1 SMOGRA-index 180 [m²/s²] für s2 TSP 600s 50 [m²] for s1 TSP 600s 200 [m²] for s2 LFS < edge of the specimen for class A2 LFS < edge of the specimen for class B LFS < edge of the specimen for class C no burning dripping off/dropping within 600s for class d0 FS 150 mm within 60 s for class B, C u. D FS 150 mm within 20 s for class E 118,81 118,81 9,25 215,22 955,65 Explanations of table standing too above: Figra 02MJ: Heat release rate with consideration of the THR of threshold value of 0,2MJ [W/s] Figra 04MJ: Heat release rate with consideration of the THR of threshold value of 0,4MJ[W/s] THR 600s: Total set free warmth during 600s [MJ] SMOGRA: Smoke development rate TSP 600s: Total set free smoke quantity during 600s [m²] LFS: lateral propagation of flames

Classification report No. 2017-1319-K1 issued 03.04.2017 page 5 of 5 3 Classification and range of application 3.1 Reference The classification was carried out according to the chapter 11 of DIN EN 13501-1 3.2 Classification The tested material is incorporated regarding its behaviour in case of fire into the class C. Concerning the smoke development the tested material is incorporated into the class s3. Concerning the dripping off behaviour the tested material is incorporated into the class d0. The classification of the tested material reads thus: C s3, d0 3.3 Area of application The classification is only valid for the material described in chapter one, in the tested colour, range of thicknesses 2 up to 10 mm and surface weights on substrates from massive mineral surfaces of classes A1 and A2 (raw density 870±50 kg/m³) according to DIN EN 13501-1. 4 Reservation This classification report replaces not a possible required type admittance or type certification of the product. Frankfurt 03 th April 2017 P. Scheinkönig Dipl.-Ing. T. Zachäus Tester in charge Head of of the business