M SERIES Multi-Jet Cold Water Meter

Similar documents
MULTI-JET WATER METERS

TURBINE METERS - WP Series

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

NIAGARA. Series WPX. Installation, Operation & Maintenance Manual. Models 210 and 222. Series WPX

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

MTX and WPX Turbine Flowmeters

MJ/MJH-Series. Pulse Meter Instructions ISO. Precision Flow Measurement. An ONICON Brand 9001:2008. if ie

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

TX101/201 Insertion Turbine Instructions

FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

500 Series DI. 500 Series DI. Materials and Specifications. Magnetic Drive Positive Displacement Disc Meters Sizes 1-1/2 and 2. Features.

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

Model MVR. Model MVR. Materials and Specifications. Magnetic Drive Vertical Turbine Meters Sizes 3/4", 1", 1-1/2", 2", 3", 4" and 6" Features

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters

400 Series IIS Magnetic Drive Positive Displacement Disc Meters Sizes 5/8-3/4-1

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

TX101/201 Insertion Turbine Instructions

SERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX

TX115/215 Hot-tap Insertion Turbine Instructions

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

S-Series. Low Flow Meter Instructions SPX SPT. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

TX 115/215 Hot-tap Insertion Turbine Instructions

FUEL FLOW SENSOR INSTALLATION GUIDE

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

MODEL 200 MULTI-JET FLOW METER

Appendix. Clearance. Skewed profiles. Application Schematics

EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX :2008 ISO CERTIFIED COMPANY

SERIES FLMG MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

MODEL 900 IMPELLER-TYPE FLOW METER

Model Horizon. Horizon. Horizontal Turbine Meters Sizes 1-1/2" through 10" NOTICE OF DISCONTINUATION, Effective October 2011

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

Positive displacement flowmeter for continuous flow measurement

Iron Gate Air Pump System Manual

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

DOR Insertion Paddle Wheel Flowmeter

HYDROMETERS OPERATION, INSTALLATION & MAINTENANCE GUIDE

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS

Table of Contents. Automatic Section A B V. Coil Piping Packages A B P P. Water Source Heat Pump Hose Kits A B H K

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

SES. Stainless Single-Jet Meter Instructions PROUDLY MADE IN THE USA

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

DPT TARGET TYPE FLOWMETERS

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

Flow Measurement & Control Solutions

Condensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter

MODEL 200 MULTI-JET FLOW METER

Series DDC DC Electronically Commutated Spherical Motor Centrifugal Pumps

A1 Commercial Grade Meters

TX100/200-SERIES INSERTION TURBINE INSTRUCTIONS TX101/201 TX115/215 ISO 9001:2008 CERTIFIED COMPANY

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

Instruction Manual RZ POSITIVE DISPLACEMENT FLOWMETERS 2AU

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

Instruction Manual. RZ Positive Displacement Flowmeters 2AU

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

Propeller Meters. Flow measurement solutions for water and wastewater

Technical Data. Series Oval Flowmeter. Model 9400

Operation and Maintenance Manual

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

Industrial Turbo Meters, Sizes 2" through 6"

DIGIFLO ELECTRONIC FLOWMETER

o-ring, testing port and a convenient integral strainer.

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

Positive Displacement Flowmeters GM020 series instruction manual

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

TX100/200-SERIES INSERTION TURBINE. T X / S E R I E S I N S E R T I O N T U R B I N E instru c tions TX101/201 TX115/215

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY

Regenerative Turbine Pumps

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Installation, Operation and Maintenance Manual

Temperature: TYPE A (1" 3") TYPE B (1/2" TYPE C (1/2" 4") TYPE D (3"

Constant Flow Valves. Specifications PVC: 1/2", 3/4", 1", 2", 3", 4" PVC PVC Flanged ANSI EPDM Stainless Steel 304 with ETFE Coating º F

Flow Measurement Solutions for Water & Waste Water INSTALLATION OPERATION & MAINTENANCE MANUAL

RUN ACCUM. TOTAL STOP BAT LOW HIGH

TYPE MP OSCILLATING PISTON FLOWMETER

sure o-ring, testing port and a convenient integral strainer. OMNI ELECTRONIC REGISTER

PDF-A Electromagnetic metering pumps. EHN series

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Series: CT. 4CT RPM - 60Hz. CT RPM - 60Hz. (See Indivdual curves for symbol number)

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Regenerative Turbine Pumps

PISTON STYLE GAUGE. Mid-West Instrument

A1 Commercial Grade Meters

INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION

Transcription:

M SERIES Multi-Jet Cold Water Meter /4 1 1-1/2" 2" Maximum Flow GPM 0 0 1 Minimum Flow GPM.2.7 1. 2.0 Maximum Operating Pressure 0 psi Maximum Operating Temperature F ( C) Also Available in Hot Water Applications Wide Variety of Pulse Rates M Series Meter 4",, 1 1 2", 2" MT Multi-Jet Totalizing Meter ME Multi-Jet Hall Effect Sensor Solid State Sensor for long life and highest reliability. This sensor requires a power source provided by metering pumps or electronic controls. MR Multi-Jet Reed Switch Uses Reed Switch to provide a dry contact closure to metering pumps and controls. Does not require external power source. C or H All HAYS M Series meters are available in (C) Cold water F ( C) and (H) Hot water 20 F (1 C). -9 SPECIAL FEATURES Low cost accuracy When accuracy is important but cost is a concern the HAYS M Series Flowmeter offers great value you can depend upon. With accuracy that is 1 1 2% of reading above transition flow. Low maintenance High quality components insures performance for many years. The impeller and register are contained in a cartridge which can be serviced without taking the meter from the line. Maintenance is easier with less down time. Wide flow range HAYS M Series Flowmeter offers flow rates from.2 GPM to 1 GPM. This wide range gives flexibility to tailor the M Series Flowmeter to the task. Gears lubricated for longevity Water lubricated gears and internals provide long life and dependable service. Sand and debris pass easily Measuring chamber designed for superior ability to pass sand and debris.

M SERIES Multi-Jet Cold Water Meter TYPICAL APPLICATIONS - Cooling Tower Treatment Metering Pump Pacing Boiler Water Treatment Water Conservation Proportional Feed Automatic Regeneration Remote Totalizing HOW TO ORDER Specify: model, size, temperature and pulse rate Model MT Multi-Jet Totalizing Only ME Multi-Jet Hall Effect Sensor MR Multi-Jet Reed Switch Sensor Temperature C Cold Water to F ( C) H Hot Water to 20 F (1 C) s per Pulse /4" s per Pulse Pulse Rates 1 1 /2" 2" s per Pulse s per Pulse 0.02 0.02 0. 1 0.077 0.029 0.029 1 0.077 0. 18 0.06 18 0.06 7 0.14 7 0.14 0.0 0.0 0. 0. 2 0.04 2 0.04 4 0.2 4 0.2 0.0 0.0. 0.. 0. 0. 0. 2.0 0. 2.0 0. 8 0.12 8 0.12 2 0.0 2 0.0 0. 0. 1 1 1 1 4 0.2 4 0.2 0.80 1.2 0.80 1.2. 0.. 0. 0.0 2 0.0 2 2.0 0. 2.0 0. 0. 2.0 0. 2.0 2 0.0 2 0.0 0. 0. 1 1 1 1 0.2 4 0.2 4 0.80 1.2 0.80 1.2 0. 0. 0.0 2 0.0 2 0. 0. 0. 2.0 0. 2.0 0.08 12.0 0.08 12.0 0. 0. 0.0 0.0 0.2 4 0.2 4 0.04 2 0.04 2 0. 0. 0.0 0.0 0. 0. 0.02 0.02 0.08 12.0 0.08 12.0 0.02 0 0.02 0 0.0 0.0 0.01 0 0.01 0 0.04 2 0.04 2 0.0 0.0 0.02 0.02 0.02 0 0.02 0 0.01 0 0.01 0 Example: 4" Multi-Jet with Hall-Effect Sensor in a cold water application with a pulse rate of pulses/gallon. Order: ME C 4"- P/G

M SERIES Multi-Jet Cold Water Meter SPECIFICATIONS Materials Body: Bronze Rotor and Gear Train: Thermoplastic Magnet: Ceramic Permanent Temperature: Cold Water F ( C) Hot Water 20 F (1 C) Maximum Operating Pressure: 0 psi Accuracy: ± 1 1 /2% of Reading Sensor: ME Solid State Hall Effect - 6-24 VDC. ma max. current sinking output MR Reed Switch Dry Contact Closure - 0 ma at 24 volts Cable Length: 12 feet (std.) 2,000 ft (max.) TECHNICAL DATA -11 Typical Registration Curve Percent Accuracy 1 0 99 Dimensions /4" 1-1/2" 2" A Meter -Straight Male Iron Pipe Threads 7 1 2" 1 4" 12 8" 8" /4" 1-1/2" 2" 2. 1 26 7. 9 2 12. 2 0 6 60 78 17. 70 91 Rate of Flow in s per Minute (GPM) 80 4 22. 4 90 117 2 0 0 1 B With Couplings (MNPT) 12 8" 16 1 8" 18 1 2" 16 7 8" Thread Size /4" 1-1/2" 2" A Meter - Straight Male Iron Pipe Threads 1 1 4" 2" 2 1 2" B With Couplings (MNPT) Pressure drop in P.S.I 0 /4" 1-1/2" 2" Typical Pressure Drop Curve 2. 1 26 7. 9 2 12. 2 0 6 60 78 17. 70 91 80 4 22. 4 90 117 2 0 0 1 4" 1 1 2" 2" Rate of Flow in s per Minute (GPM) Electrical Connections: ME Sensor Connection has three conductors MR Sensor Connection has two conductors Black Power (-) White Signal Non Polar Connections Red Power (+) 6-24 VDC

-12 NOTES

M SERIES Multi-Jet Hot Water Meter Dry Dial Register For Hot Water use to 20 F (1 C) For Horizontal Installation Operating Pressure 0 psi 4" 1 1 2" 2" Maximum Flow - GPM 22 2 88 12 Minimum Flow - GPM 2.8 7 8.6 MRH Series Sizes 4",, 1 1 2", 2" MTH Multi-Jet Totalizing Only Hot Water MRH Multi-Jet Reed Switch Sensor Hot Water Uses Reed Switch to provide a dry contact closure to metering pumps and controls. Does not require external power source. -1 SPECIAL FEATURES Low Cost Accuracy When accuracy is important but cost is a concern the HAYS M Series Flowmeter offers great value and accuracy you can depend upon. Low Maintenance High quality components insure performance for many years. Hermetically sealed register is exchangeable under pressure conditions. Maintenance is easier with less down time. Wide Flow Range HAYS M Series Flowmeter offers flow rates from.2 GPM to 1 GPM. This wide range gives flexibility to tailor the M Series Flowmeter to the task. Sand and Debris Pass Easily Measuring chamber designed for superior ability to pass sand and debris.

M SERIES Multi-Jet Hot Water Meter TYPICAL APPLICATIONS Boiler Water Treatment Proportional Feed Remote Totalizing HOW TO ORDER Specify: model, pulse rate and size -14 Pulse Rates /4",, 1 1 /2", & 2" s per Pulse 0 0.00 0 0.0 0 0.0 0.02 0.0 2 0.0 0.00 12.0 0.080 0.0 0.0 4 0.20 0. 2.0 0.0 2 0.00 1.2 0.800 1 1.000 0.0 2.000 0. 2.00 0..0 0.2 4.000 Model MTH Multi-Jet Totalizing Hot Water MRH Multi-Jet Reed Switch Hot Water Temperature H Hot Water to 20 F (1 C) Example: Hot Water Multi-Jet Meter 4" with a pulse rate of 2 gallons per pulse. Order: MRH 4" 2 G/P

M SERIES Multi-Jet Hot Water Meter SPECIFICATIONS Materials Body: Bronze Rotor and Gear Train: Thermoplastic, High Temperature Magnet: Ceramic Permanent Temperature: Hot Water 20 F (1 C) Maximum Operating Pressure: 0 psi Accuracy: ± 1 1 /2% of Reading Sensor: MRH Reed Switch Dry Contact Closure - 0 ma at 24 volts Cable Length: 6 feet (std.) 2,000 ft (max.). 24 awg unshield cable TECHNICAL DATA Typical Registration Curve - Percent Accuracy 1 0 99 Dimensions /4" 1-1/2" 2" A Meter -Straight Male Iron Pipe Threads 7 1 2" 1 4" 12 8" 8" /4" 1-1/2" 2" 2. 1 26 7. 9 2 12. 2 0 6 60 78 17. 70 91 Rate of Flow in s per Minute (GPM) 80 4 22. 4 90 117 2 0 0 1 B With Couplings (MNPT) 12 8" 16 1 8" 18 1 2" 16 7 8" Thread Size /4" 1-1/2" 2" A Meter - Straight Male Iron Pipe Threads 1 1 4" 2" 2 1 2" B With Couplings (MNPT) Pressure drop in P.S.I 0 /4" 1-1/2" 2" Typical Pressure Drop Curve 2. 1 26 7. 9 2 12. 2 0 6 60 78 17. 70 91 80 4 22. 4 90 117 2 0 0 1 4" 1 1 2" 2" Rate of Flow in s per Minute (GPM) Electrical Connections: HAYS Hot Water Pulse Meters are supplied with a six foot cable attached to the sensor specified. MR Sensor Connection has two conductors Meter Reed Switch Non Polar Connections

M SERIES Multi-Jet Meter INSTALLATION CAUTION! M SERIES meters are intended for use with water and non-hazardous water based fluids only. Position. M Series meters should be installed in a horizontal position with register on top. The meter will operate in a vertical position, but will tend to indicate less than actual flow, and bearing life will be shortened. Couplings. Most M Series meters are installed with meter couplings, and should be ordered with the meter. The meter thread and pipe size are the same. However, the meter couplings are required to install the meter and will be one size larger than the meter thread or pipe size. For example, the thread on a /4" meter is IPS. Standard pipe couplings are sometimes threaded onto the meter, but this is not recommended, since the meter thread is for mechanical connection only, and sealing is done by the gasket in the meter coupling. (Note: when installing meter couplings, check to be sure that the gasket is in place between the coupling and the meter.) The advantage of meter couplings is that they act as unions for the easy removal of the meter from the line. Meter couplings provide standard male NPT threads the same nominal size as the meter for easy connection to the system. The "Dimensions" table gives overall lengths. -16 Inlet Disturbance. Multi-jet meters are less sensitive to turbulence than some other types of flowmeters, but five diameters of upstream straight pipe are recommended. All M Series meters have built-in inlet strainers. In installations with a high degree of suspended solids, an in-line strainer upstream of the meter is a worthwhile precaution. Air Bleed. When the meter is first installed, trapped air should be removed if present in the meter. To do this, loosen meter couplings slightly and rotate the meter to an inverted position. Allow water to flow through the meter, then rotate it back to an upright position and retighten. Electrical Connections. ME and MR meters are supplied standard with a twelve foot cable attached to the sensor. The MR cable has two conductors and the ME cable has three (see the "Electrical Connections" diagram for correct connections). ME meters are supplied standard with a connector which plugs directly into a specified metering pump or a HAYS control. For an additional charge, MR meters can also be ordered with connectors. Pulse Contact. Both ME and MR meter sensors respond to a magnet which is turning on the face of the meter under the lens. The sensors give one output "pulse" (on/off) each time a magnet pole passes. The magnets have one, two or four poles. The white dots on the magnet indicate the number of poles. The sensors are designed for electronic control loads. They should not be used to switch power loads such as motors or lights, and they should not be connected to 1 VAC (see "Specifications" for maximum load ratings). Inlet Strainer Cleaning. Do this yearly, or as required. Remove the meter and gently backflush it to loosen particulates trapped by the strainer.

M SERIES Multi-Jet Meter TROUBLESHOOTING GUIDE PROBLEM PROBABLE CAUSE TO CHECK TO REPAIR No pulse Meter not operational Foreign matter restricting Remove obstruction signal meter movement Incorrect wiring connec- ME Series meters (check Make proper connections polarity) black: -12VDC, tions white: input signal, red: +12 VDC MR Series meters (non polar connection) -12 VDC, input signal Non-functional sensor ME Series meters - check Contact HAYS for +12 VDC MR Series meters - check continuity -17 Meter runs Meter improperly installed. Be certain arrow on meter Install meter in proper in reverse Flow in wrong direction body is in direction of flow direction Inaccurate Not enough straight pipe Check distance of straight Re-install at proper metering between meter and flow upstream piping. Should distance disturbance be a minimum of pipe diameters Water visible This is normal (it is a wet dial meter) Air bubble Air trapped during Invert meter. Allow water installation to flow through meter. Rotate meter to original position. Resume opertion