KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions. Please read these instructions carefully

Similar documents
KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

KEYSTONE OPTISEAL F14/16-15/17 AND BREWSEAL BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Butterfly valves Figure 56 Installation & Maintenance Instructions

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

KEYSTONE SERIES GRF RESILIENT SEATED BUTTERFLY VALVES INSTALLATION AND OPERATION MANUAL

KEYSTONE SERIES GR RESILIENT SEATED BUTTERFLY VALVES GRW/GRL INSTALLATION AND OPERATION MANUAL

KEYSTONE. Check valves Figure 85/86 Installation & Maintenance Instructions. Figure 85. Figure 86.

Keystone Figure 85/86 Check valves Installation and Maintenance Instructions

KEYSTONE Figure 990/991 Butterfly valves Installation, operation and maintenance instructions

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

GT-200 GATE VALVES PN16, Screwed end

Installation Operation Maintenance

2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:

The valves should be stored on a pallet or skid in a clean, dry warehouse. If the valves must be stored outside, the following apply:

NYL Resilient Seated Butterfly Valves Operation and Maintenance Instructions

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

Installation & Operation Manual

ONYX VALVE CO MODEL CER with JORDAN ACTUATOR Installation & Maintenance

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

NEOTECHA NEOSEAL BUTTERFLY VALVE INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE

IOM Manual. IOM Manual. Series 76/77.

ONYX VALVE CO MODEL CER and CEP Installation & Maintenance

Recommended BFV Installation, Maintenance & Repair Procedures Ultraflo 300 & 400 Series Valves

Series 820 AWWA Butterfly Valves

KEYSTONE. Hygienic butterfly valves model F250 & F251 Installation & Maintenance Instructions. 1 Contents 1 Contents 1

COMMERCIAL. BV & BVM Series Installation Instructions 06/29/15

INSTALLATION, OPERATION AND MAINTENANCE FOR SERIES 500 K-FLO BUTTERFLY VALVES

Sub Section Title Page No.

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

These installation and maintenance instructions must be read in full and completely understood before the installation!

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

I-VIC300MS. Vic -300 MasterSeal Butterfly Valves WARNING SERIES 761

Scope. Applicability. Caution. I & M CV3000 Series. Storage. Installation & Maintenance Instructions for Marwin CV3000 Series Three Piece Ball Valves

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

KTM Hindle Series 300 Ultra-Seal two piece metal seated ball valves Installation and Maintenance Instructions

ONYX VALVE CO MODEL DAC-ADA Installation & Maintenance

PO Box 411 Berwick PA VALV

Installation, Operation, and Maintenance Manual

26 Series Stainless Steel 2-way Ball Valves

ONYX VALVE CO MODEL CHR & CHP Installation & Maintenance

DeZURIK 2 20" BOS BUTTERFLY VALVES

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

Keystone Figure V11 Butterfly Valve Installation, Operation and Maintenance Manual

ONYX VALVE CO MODEL DEC Installation & Maintenance

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance

I-VIC300MS. Series 761 Vic-300 MasterSeal Carbon Steel Butterfly Valve Series 461 Vic-300 MasterSeal Stainless Steel Butterfly Valve WARNING

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

KEYSTONE. The HiLok high performance butterfly valves offer efficient, bidirectional sealing across a wide spectrum of service conditions.

MUELLER ECCENTRIC PLUG VALVE

V-SEGMENT SERIES V-Port Segment Control Valves (VS/VV/VM) Installation & Maintenance Manual

Installation, Operation, and Maintenance Manual

K-LOK Installation, Operation, Maintenance and Troubleshooting

ONYX VALVE CO MODEL DBC Installation & Maintenance

CENTER LINE. INSTALLATION and MAINTENANCE INSTRUCTIONS RESILIENT SEAT BUTTERFLY VALVES MANUAL AND AUTOMATED

TITAN FLOW CONTROL, INC.

When installing the screwed end, socket weld & flanged end valves the following respective procedures shall be followed for better performance.

Manufacturer s Declaration as per EU-Directives Page 1 of 2

McCannalok HIGH PERFORMANCE BUTTERFLY VALVE OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Bray/McCannalok High Performance Butterfly Valve Operation and Maintenance Manual

YOUR GLOBAL FLOW CONTROL PARTNER. BRAY/MCCANNALOK EN High Performance Butterfly Valve Operation and Maintenance Manual

Double Offset High Performance Butterfly Valve

Model DFR 070/156/220 Rotary Actuator

IMO-200EN 09/2010. Trunnion mounted forged ball valves Model FF and GG. Installation, Maintenance and Operating Instructions IMO-200EN 09/2010

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual

MK Series - High Performance Butterfly Valves Operation and Maintenance Instructions

CONTROLS RESILIENT SEATED BUTTERFLY VALVES 20/21, 22/23, 30/31, 3A/3AH, 31H, 31U, 32/33, 35/36, 36H. The High Performance Company

PNEUMATIC SLIDING VALVE

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Power-Seal High Performance Butterfly Valve: Series P1 Installation & Maintenance Manual

IOM IR-110-X. Solenoid Control Valve

Butterfly Valve Type 57P

Installation, Operation, and Maintenance Manual

Keystone K-LOK Series 360/362 and 370/372 Installation, Operation, Maintenance and Troubleshooting

Keystone K-LOK Series 360/362 and 370/372 Installation, Operation, Maintenance and Troubleshooting

Operating & Maintenance Manual For Steam Conditioning Valve

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Diaphragm Valves Type 15

Butterfly Valve Type 58 (PDCPD)

Installation, Operation, and Maintenance Manual

Storage: The valves should be stored on a pallet or skid in a clean, dry location.

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

Easytork Vane Actuator IOM

METERING VALVE 2" STEM GUIDED

Bray/Mckannalok Butterfly Valve Series 40/41/42/43/44/45 Installation Manual Technical Bulletin No Date: May 2004/Page 1 of 6

Instructions for installation, operation and maintenance of: GATE VALVE

INSTALLATION & MAINTENANCE MANUAL

Installation, Operation and Maintenance Instructions Series 608 Ball Valve

LC149 SERIES BUTTERFLY VALVE INSTALLATION, OPERATION, & MAINTENANCE

Crispin Valves Operating Guide. Crispin

Transcription:

KEYSTONE Please read these instructions carefully This symbol indicates important messages and safety instructions. Hazard potentials: disregarding of instructions improper use of product insufficiently qualified personnel Valve application to be within the pressure/ temperature limits indicated in the P/T diagram. Essential points and functions of the valve should be inspected on a regular basis. When the valve is used in an end-of-line function, PED Cat-I applications are allowed only. For other categories, contact factory. 1 Storage & handling 1.1 Protection Keystone butterfly valves are delivered with protection in accordance with the Keystone Engineering Instructions, to protect the valve seats and disc from damage. Wrapping and/or covers should be left in place until immediately before fitting to the pipe. 1.2 Storage When valves are to be stored for some time (2 months or more) before being fitted, storage should be in the original delivery crates or cases. 1.2.1 Storage conditions The valves should be stored off the ground in a clean, dry indoor area. Protect the valve from temperature and humidity extremes, and exposure to excessive dust, moisture, vibration, deformations, sunlight and ozone. Recommendations 1. Temperature: storage temperature below 25 C, above 0 C preferable below 15 C. 2. Humidity: storage conditions should be such that condensation does not occur, store in a dry environment. Maximal 50% relative humidity. 3. Light: valve rubbers should be protected from light, in particular direct sunlight or strong artificial light with high ultra violet. 4. Ozone: storage rooms should not contain any equipment generating ozone. E.g. lamps, electric motors. Important Before valves are being installed or used the following actions are recommended. 1. Valves/parts have to be inspected and thoroughly cleaned if required. 2. Rubber parts need to be greased with silicone grease if not present anymore. 3. All surfaces in contact with seats have to be thoroughly cleaned and greased with silicone grease if stored for more than 5 months. 1.3 Handling 1.3.1 Packed valves Lifting and handling of the packed valves in crates should be carried out by appropriate lifting equipment. If a fork lift truck is used, appropriate fork hitches are required. The lifting and handling of packed valves in cases will be carried out in the lifting points. The transportation of all packed material should be carried out safely and according the local safety regulations. 1.3.2 Unpacked valves The lifting and the handling of these valves has to be carried out by using appropriate means and by respecting the carrying limits. The handling must, preferably, be carried out on pallets, protecting the machined surfaces and seat to avoid damage. When lifting the large dimension valves, the sling and the hooking of the load must be carried out by using the appropriate tools (brackets, hook, fasteners) and load balancing tools in order to prevent the valves from falling or moving during the lifting and handling. The valve may be lifted only by slings attached to the flange holes or valve body; never to the actuator or the valve opening. www.pentair.com/valves Pentair reserves the right to change the contents without notice EBPJV-0755-EN-1305

2 Installation WARNING! For safety reasons, it is important to take the following precautions before you start work on the valve: 1. Personnel making any adjustments to the valves should utilize suitable equipment. All required personal protection means should be worn. 2. The line must be depressurized before installing the valve. 3. Personnel trained in all aspects of manual and mechanical handling techniques must carry out handling of the valves. 4. Misuse of the valve is not allowed. For example: the valve, handles, actuators or other parts may not be used as climbing tools. 5. Ensure that valve pressure/temperature limitations marked on the identification tag are within the service conditions. The trim number on the valve s tagplate identifies the valve materials. See Product Manual for valve specific P/T diagram and trim number definition. 6. Ensure that valve materials are compatible with the pipeline fluid. 2.1 Valve inspection 1. Carefully remove the valve from the shipping package (box or pallet) avoiding any damage to the valve or, in case of automated valves, to the electric or pneumatic/hydraulic actuator or instrumentation. 2. Confirm that the materials of construction listed on the valve nameplate are appropriate for the service intended and are as specified. 3. It is not allowed to use third party spare parts. In case of third party spare parts, safe operation is not guaranteed. 2.2 Flange and pipe compatibility Check matching of flange drilling pattern of valve and pipe before assembly. Flanges have to meet the following requirements: - The face inside diameter should be: D min. : The valve Q-dimension + adequate disc clearance. D max. : The optimum inside diameter (ID) is equal to the inside diameter of flange standard EN 1092-1, table 8, type 11. For larger than D max inside diameters or other flange types please contact your local Pentair Sales organization, as larger inside diameters might result in reduced valve functionality. - If the flange (or pipe) is provided with a raised face, the diameter of this shall be at least 8 mm larger than the YY-dimension of the valve. The use of the flange-gaskets is not allowed since it might damage the valve. The Keystone seat-face design eliminates the need for the gaskets. Use flange bolting in agreement with appropriate standard. YY D max./min Q Do not use flange gaskets, these lead to valve damage! 2.3 Valve installation The valves are bi-directional and may be fitted in either direction relative to the flow. The valve will control flow equally in either direction. The recommended installation position is shaft horizontal and the lower disc edge opening down-stream. (Especially for slurry service and media with a tendency for sedimentation). For optimum valve control and smooth performance, it is recommended to have a 10 to 20 pipe diameters of straight run inlet piping and 3 to 5 pipe diameters straight outlet piping. A valve is no crow-bar. Do not use the valve to spread the flanges. Seat damage might be the result. Pentair reserves the right to change the contents without notice page 2

Notes - The valve can be installed in the pipeline either with or without the actuator mounted on top of the valve. Make sure that you can turn the disc cautious so you can feel a mismatch resulting from a disc touching the adjacent piping. - Do not use the valve as a support of the pipe line construction. - Adjacent piping must be positioned so that minimal piping stresses are transmitted to the valve flanges during or after installation. - Handling and lifting of the valves during installation MUST be performed following the same instructions described in previous paragraph 1.3 Handling. Important Mating flange faces should be in good condition and free of dirt and/or inclusions. Both pipe insides to be well cleaned. 2.3.1 Existing system (see sketch) 1. Check whether the flange distance meets the valve face-to-face dimensions. Spread with adequate tooling the flanges for easy insertion of the valve. 2. Insert some flange bolts in the pipe flanges, to help you bear the valve after insertion. 3. Close the valve so far, that the disc edge is at least 10 mm within the body. 4. Insert the valve between the flanges, center the valve body and insert all flange bolts. Tighten the flange-bolts hand tight. 5. Slowly open the valve completely. (The disc is in line with parallel flats or keyway in stem head. Keyway points towards disc edge). 6. Maintain the valve flange alignment while gradually removing the flange-spreaders and tighten the flange-bolts hand tight. 7. Slowly close and open the valve to check for adequate disc clearance. 8. Cross-tighten all bolting to the proper torque. Do not over tighten. 2.3.2 New system (see sketch) 1. With the disc in near-closed position center each mating flange with the valve body. Fix the body with some flange-bolts and tighten the bolts. 2. Use the flange-valve-flange assembly for fit-up and centering to the pipe. 3. Tack-weld the flanges to the pipe. 4. Remove the bolting and remove the valve from between the flanges. Important Do not finish-weld the flanges to the pipe with the valve bolted between the flanges as this will result in serious heat-damage to the seat. 5. Finish-weld the flanges to the pipe and allow the flanges to cool completely. 6. Install the valve now according to the procedure for installing in existing systems. 2.4 Valve verification Check the operation of the valve by operating it to full open and full close. To verify the valve operation, the disc position indicator on the actuator or the handle should rotate between the full open and full close indicators on the actuator or throttle plate. Generally the valve disc travels clockwise to close. Pentair reserves the right to change the contents without notice page 3

Existing system New system 1. Spread the flanges with the adequate tooling. Insert some flange bolts to bear the valve. 1. Center a flange-valve-flange assembly between the pipes. 2. Open the valve and remove the flange spreads 2. Tack weld the flanges to the pipes. 3. Close the valve clockwise, return to open position and cross-tighten all bolting. 3. Remove the valve and finish weld. Install the valve according to the procedure in the left column. 2.5 Sources of possible danger This section contains some examples of possible foreseen danger sources. 2.5.1 Mechanical When manual operators are used, available space should be checked in order to avoid hands being clamped. 2.5.2 Electrical If static charges can initiate explosions, the valve should be grounded. 2.5.3 Thermal If the valve is used in applications with a fluid temperature above 40 C the outside of the body might be hot. Sufficient measurements should be taken to avoid burning. A manual operated valve should be opened and closed with sufficient protection for the personnel operating the valve. For example: protecting gloves. 2.5.4 Operational Closing a valve too fast may result in waterhammer in the upstream part of the pipeline. Waterhammer results in excessive stresses in the valve and will cause severe damage. Waterhammer should be avoided in all circumstances. Due to differential pressure across the valve disc, butterfly valves have the tendency to be closed by the flow. Take care when unlatching the valve operating mechanism. 2.6 Trouble shooting guide Symptom Possible cause Resolution Valve would not rotate Actuator has failed Replace or repair Valve packed with debris Flush or clean valve to remove debris Valve leaking Valve not fully closed Close valve Debris trapped in valve Cycle and flush (with valve open) to remove debris Seat is damaged Replace seat Jerky operation Extreme dry application Put some silicon oil on seat or increase size of actuator Air supply actuator Increase air supply pressure and/or inadequate volume Pentair reserves the right to change the contents without notice page 4

3 Maintenance The Keystone butterfly valves Figure 9 are designed to require a minimum of maintenance. WARNING! Depressurize and, if necessary in case of dangerous fluids, drain the line and flush with appropriate cleaning fluid before starting any maintenance. Failure to do so may cause serious personal injury and/or equipment damage. Before disassembling the valve, ensure the valve has been decontaminated correctly from any harmful gasses or liquids and that it is within a safe temperature range for handling. Personnel making any adjustments to the valves should utilize suitable equipment. All required personal protection means should be worn. Only personnel trained in all aspects of manual and mechanical handling techniques must carry out handling of all valves. 3.1 Routine maintenance Routine maintenance or lubrication is not required other than periodic inspection to ensure satisfactory operation and sealing. 3.2 Removing the valve 1. Turn the disc to nearly closed position. (The disc is in line with the parallel flats or keyway in the stem. Keyway points towards disc edge). 2. Loosen all flange bolts and remove the bolts, which prevent removing of the valve. 3. Spread the flanges with adequate tooling, and remove the valve. 3.3 Valve disassembly (see sketch) 1. Turn the disc to almost open position. 2. Remove actuator. 3. Remove the body screws. 4. Remove the lower part of the body. This is more or less held by the seat dovetail. Use two screwdrivers in the body-splits to separate the body halves and pull the bottom-part off with a rotating motion. 5. Pull the disc stem and seat out of the body top part. 6. To remove the disc stem from the seat, deform the seat into a long oval sufficient to clear the end of the short stem, move the short stem-end out off the seat bore, and pull the long end from the seat stem hole, using a rotating motion. 7. The body top part contains a bushing and shaft-seal. Generally there is no need to remove these parts. 8. Some valve types are equipped with a bottom plug. If applicable remove circlip and pull the plug, containing an O-ring, out of the body bottom part. 9. Remove the O-ring from the plug. 3.4 Valve assembly (see sketch) 1. Clean all parts. Use silicone grease on the disc stem to facilitate the assembly. If the valve has to be provided with a TFE-lined-seat preheat this seat during half an hour in nearly boiling water before assembly. 2. If required assemble shaft-seal and bushing in body top neck. 3. Take the disc stem and insert the long stem-end into a hole of the seat, using a twisting motion. 4. Deform the seat into a long oval sufficient to clear the end of the short stem. With the disc stem simulating an open position, move the short stem-end into the elongated seat-bore and assemble the short stem-end into the other seat stem-hole by releasing the distorted seat. Do not put oil or grease between body and seat. 5. Push the long stem-end of the disc stem/seat unit into the body top part. Push the seat lip and groove in place. 6. Assemble the bottom part of the body. Take care of the positioning of the bottom part. The little rectangular cast on indicator near the body split should correspond to the indication on the bottom part. Install the body screws and tighten securely. Take care that the body parts are aligned securely. 7. Some valve types are equipped with a bottom plug. If applicable, place the O-ring onto the plug. Place the plug into the body and position it with a circlip. 8. Mount the actuation and test function. 3.5 Re-installing the valve See paragraph 2.3.1. Pentair reserves the right to change the contents without notice page 5

Top view Key-way sizes 250-600 mm Mounting holes Parallel flats sizes 25-200 mm Figure 9 Parts list 1. Bushing 2. Shaft seal 3. Top half body 4. Seat 5. Disc stem 6. Bottom half body 7. Body screws Pentair reserves the right to change the contents without notice page 6