2 Pine Trees, Chertsey ane, Staines-upon-Thames, TW18 3HR, UK Kiwa td t/a Kiwa Gastec Kiwa House Malvern View Business Park Stella Way Bishops Cleeve Cheltenham Gloucestershire G52 7DQ Contact: Mrs Thomas Tel: +44 (0)1242 677877 Fax: +44 (0)1242 676506 E-Mail: lesley.thomas@kiwa.co.uk Website: www.kiwa.co.uk aboratory locations: ocations covered by the organisation and their relevant activities ocation details Activity ocation code Address Kiwa House Malvern View Business Park Stella Way Bishops Cleeve Cheltenham Gloucestershire G52 7DQ ocal contact Mrs Thomas Tel: +44 (0)1242 677877 Fax: +44 (0)1242 676506 E-Mail: lesley.thomas@kiwa.co.uk Website: www.kiwa.co.uk See Detail Of Accreditation Table below. Site activities performed away from the locations listed above: ocation details Activity ocation code The customers site or premises must be suitable for the nature of the particular testing undertaken and will be the subject of contract review arrangements between the laboratory and the customer. ocal contact Mrs Thomas Tel: +44 (0)1242 677877 Fax: +44 (0)1242 676506 E-Mail: lesley.thomas@kiwa.co.uk Website: www.kiwa.co.uk See Detail Of Accreditation Table below. S Assessment Manager: GP Page 1 of 6
2 Pine Trees, Cher t s ey an e, Stai nes - u po n-tham es, TW 18 3HR, UK Kiwa td t/a Kiwa Gastec DETAI OF ACCREDITATION ocation Bituminous Coals Combustion Tests in: Inset Open Fire Fuel testing procedure No 19 Naturally Occurring Smokeless Solid Fuels Combustion Tests in: 1) Gravity-Feed Central Heating Boiler 1) Fuel testing procedure No 20 Fuel testing procedure No 20.1 2) Inset Roomheater 2) Fuel testing procedure No 15.1 Manufactured Solid Smokeless Fuels Combustion Tests in: 1) Gravity-Feed Central Heating Boiler 1) Fuel testing procedure No 20 Fuel testing procedure No 20.1 2) Inset Roomheater 2) Fuel testing procedure No 15.1 3) Inset Open Fires 3) Fuel testing procedure No 19 Fuel testing procedure No 19.1 All Types of Solid Fuels Gravimetric Measurement of Smoke Emission Fuel testing procedure No 18 Firelighters Ignition Test Fuel testing procedure No 21 Smoke Reducing Solid Fuel Burning Domestic Appliances Gravimetric and Optical Measurement of Smoke Emission PD 6434:1969 Solid Fuel Appliance testing procedure No 12.1 Residential Space Heating Appliances Fired by Wood Pellets BS EN 14785:2006 (excluding Clause A.4.9.3) Assessment Manager: GP Page 2 of 6
2 Pine Trees, Cher t s ey an e, Stai nes - u po n-tham es, TW 18 3HR, UK Kiwa td t/a Kiwa Gastec ocation Residential Independent Boilers Fired by Solid Fuel Nominal Heat Output up to 50 kw BS EN 12809:2001 +A1:2004 (inc corrigenda September 2003, June 2006 and August 2007) Residential Cookers Fired by Solid Fuel BS EN 12815:2001+A1:2004 (inc corrigendum April 2008) (excluding Clauses A.4.15 and A.4.18) Inset Appliances including Open Fires Fired by Solid Fuels BS EN 13229:2001 +A2:2004 (inc corrigenda September 2003, June 2006 and August 2007) (excluding Kachelöfen or Putzöfen appliances, and Clauses A.4.9.4, A.4.9.6 and A.4.10) Roomheaters Fired by Solid Fuel BS EN 13240:2001+A2:2004 (inc corrigenda September 2003, June 2006 and August 2007) (excluding Clauses A.4.9.3 and A.4.9.5) Slow Heat Release Appliances Fired by Solid Fuel BS EN 15250:2007 Heating Boilers for Solid Fuels, Manually and Automatically Stoked, Nominal Heat Output of up to a maximum of 300 kw BS EN 303-5:2012 (excluding Clauses 4.2.2, 4.2.3, 4.3.9.2, 4.3.9.3, 5.4 and 5.5) Residential Solid Fuel Burning Appliances Particulate, NOx and Hydrocarbon Emissions Tests DD CEN/TS 15883:2009 DIN Plus method Assessment Manager: GP Page 3 of 6
2 Pine Trees, Cher t s ey an e, Stai nes - u po n-tham es, TW 18 3HR, UK Kiwa td t/a Kiwa Gastec ocation Oil Fired Cookers With or Without Boilers with Heat Outputs up to 45 kw OFTEC Oil Fired Appliance Standard OFS-A101:2005, Edition 3 (excluding Clauses 2.21 and Appendix N) Oil Fired Heating Boilers with Atomising Burners with Outputs up to 70 kw OFTEC Oil Fired Appliance Standard OFS-A100:2004, Edition 4 (excluding Clauses 4.2 and 4.3 and Annexes A, C, D, E) Oil-fired Forced Convection Air Heaters - Stationary and Transportable for Space Heating Measurement (by losses method) BS EN 13842:2004 Clause 5.6 Heating Boilers with Forced Draught Burners BS EN 303-1:1999 (inc Amendment No.1) Heating Boilers with Forced Draught Atomizing Oil Burners BS EN 303-2:1999 (inc Amendment 1) Heating Boilers with Forced Draught Burners with Outputs up to 70 kw and a Maximum Operating Pressure of 3 bar BS EN 303-4:1999 Domestic Hot Water Heating Combination Boilers with Forced Draught Atomizing Oil Burners of Nominal Heat Input Not Exceeding 70 kw BS EN 303-6:2000 Heating Boilers with Atomizing Oil Burners BS EN 304:1992 (inc Amendments No.1 and No.2) Assessment Manager: GP Page 4 of 6
2 Pine Trees, Cher t s ey an e, Stai nes - u po n-tham es, TW 18 3HR, UK Kiwa td t/a Kiwa Gastec ocation Gas-fired Heating Boilers - Type B11 and B11BS Boilers Fitted with Atmospheric Burners of Nominal Heat Input Not Exceeding 70kW BS EN 297:1994 (inc Amendment Nos.1, 2, 3, 4, 5 & Corrigendum 1). Clauses 3.7 and 4.7 only Gas-fired Central Heating Boilers Assembly Comprising a Boiler Body and a Forced Draught Burner BS EN 303-3:1999 (inc Amendment No.1 and Corrigendum No.1), Clauses 5.4 and 6.4 only Gas-fired Central Heating Boilers Type C Boilers of Nominal Heat Input Not Exceeding 70 kw BS EN 483:1999+A4:2007 (inc Corrigendum June 2006). Clauses 6.7 and 7.6 only Gas Fired Storage Water Heaters for the Production of Domestic Hot Water BS EN 89:2000 (inc Amendments nos.1 and 2), Clause 8.1 only Independent Gas Fired Convection Heaters BS EN 613:2001 (inc Amendment No.1 and Corrigendum No.1) (B and C1 type appliances) Non-domestic Forced Convection Gas-fired Air Heaters For Space Heating Not Exceeding a Net Heat Input of 300 kw, Incorporating a Fan to Assist Transportation of Combustion Air or Combustion Products BS EN 1020:2009 Clause 6.2 Independent Gas Fired Flueless Space Heaters for Nominal Heat Input Not Exceeding 6 kw BS EN 14829:2007 Assessment Manager: GP Page 5 of 6
2 Pine Trees, Cher t s ey an e, Stai nes - u po n-tham es, TW 18 3HR, UK Kiwa td t/a Kiwa Gastec ocation Decorative Fuel Effect Gas Appliances BS EN 509:2000 (incorporating Amnds 1 & 2) Dedicated iquefied Petroleum Gas Appliances Barbecues for Outdoor Use Contact Grills Included BS EN 498:2012 Steam, hot water and high temperature heat transfer fluid boilers Thermal Tests BS 845-1:1987 thermal performance of biomass boilers using indirect (losses) method (incorporating Amendment 1) S *The above tests exclude in each case: Quality of Materials; Quality of Welding; Pressure Testing of Boiler; Testing of Screw Threads; Quality of Vitreous Enamel Finish; Measurement of Thickness of Enamelled Components; Dress Guard Testing. END Assessment Manager: GP Page 6 of 6