39CZ. Air-handling unit PRODUCT SELECTION DATA

Similar documents
ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

MODULAR AIR HANDLING UNITS GAH SERIES

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

AIR HANDLING UNIT. MODEL: PM0809 to PM CFM to CFM

climaciat airtech Air handling units Air handling for all applications Climaciat Airtech The technological choice Performing to new standards

Heat recovery units type GTDHR

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Handling Units. Geniox. Accessories

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

Fan coil units MAJOR 2 CV/CH

D M S 760 C01 A A 1 1

HIGH EFFICIENCY HEAT RECOVERY UNITS WITH ROTARY WHEEL RHE Series

BRIZA 22 HYBRID HEATING & COOLING

AHN 064 to 304 EHN/CHN 064 to 304

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

TYPICAL SPECIFICATION: Critical Process Roof Top Unit 7/14/15

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes

DOUBLE SKIN MODULAR AIR HANDLING UNIT. Round Edge (ADM-AHU)

Swimming Pool CSR2 Heat Recovery Equipment

Complete HVAC Capability

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

WCTA SERIES Air Handling Units. ( ,000 m 3 /h )

Silent centrifugal air heater hot water supply

EUMM. Air conditioning unit Catalogue

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

AMOUNT IN Rs After adding percentage above or at par or below In In words figures. ESTIMATED COST (IN Rupees) In figures. In words

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

McQuay MDM Air Handling Unit CMDM

PCXDMT1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.

Vortice. Air treatment

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

AIR-AIR ENERGY CONSERVATION MODULE

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

VAHU Vertical Air Handling Unit

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

Air distribution product

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

Airsock unit coolers THOR-A. Standard coolers in a revolutionary design

CENTRIFUGAL FAN COIL UNIT VCE

Des solutions dans les règles de l air. CBP Range COMBIBOX CONCEPT. Ventilation modules Thermic modules Air flow from 800 to m 3 /h

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

FS Fan-Coil Units Hi-Rise, Vertical

XeteX, Inc. All Rights Reserved.

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

Prepared By : Checked By : Approved By : Page 1 out of 6

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

Fan coil unit NBS 100/150

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: S38H1 W38H1 S43H1 W43H1 S49H1 W49H1 S61H1 W61H1. General Notes. Contents.

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Contents. Burner Components. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Contents. Burner Components. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

TECHNICAL MANUAL SOFFIO Ducted units

MegaBox Product-specific information

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. General Notes. Contents. Important MODEL: WH381 WH431 WH491

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

Climas y Proyectos Leyco, S.A. de C.V.

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

VIFB Coil Technical Guide

SECTION AXIAL HVAC FANS

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS. Models: W30H1 W36H1. Contents. General Notes. Important. Description

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation. Low Energy Consumption

ED.X Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS. COOLING CAPACITY FROM 6,7 TO 138 kw. ED.X 331 U Kc

Tons BTU/h S.E.E.R* E.E.R** HSPF

REPLACEMENT PARTS MANUAL

AC Commercial Fans Edition. ErP ready

CHP

CS3 Series 50/60Hz. Modular Central Station Air Handling Units Air Volume: 1000 to cfm (1700 to m 3/hr)

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: S38H1 W38H1 S43H1 W43H1 S49H1 W49H1 S61H1 W61H1 S38H1D S43H1D S49H1D S61H1D

Everest XV. ErP. High Efficiency HRV Fan Unit READY

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

Transcription:

PRODUCT SELECTION DATA AHU for all applications Designed to meet the EN 13053 and EN 1886 standards The effective solution for service sector, industry and healthcare applications Air-handling unit 39CZ N 16.04.011 Range :39CZ CARRIER participates in the ECP programme for LCP/HP Check ongoing validity of certificate: www.eurovent-certification.com www.certiflash.com Translation of the original document 20137, 03.2016

39CZ ST - CL & HE Air flow: 1000 to 66000 m 3 /h Use The 39CZ range is designed for the service sector, industry and healthcare markets, to meet different requirements in terms of air mixing, filtration, heating, refrigeration, dehumidification, humidification, ventilation, recovery and sound attenuation. It is available as a horizontally-mounted version for installation indoors or outdoors with a roof and protection accessories. The range is available in a single or dual-flow version. Thanks to the broad spectrum of solutions on offer, and the product's excellent modularity, the specifications for this product will always comply with the EN 13053 and EN 1886 standards, whatever its configuration. Range The 39CZ range consists of 14 sizes to handle air flow rates from 1000 to 66,000 m 3 /h. The diagram below shows how to preselect the necessary size based on: - The flow speed in the active front section of the exchanger coils. - The air flow rate to be handled. External wall with RAL 7035 paint Compliance with the provisions of the EN 13053 standard Classification in accordance with European standard EN 1886 Casing resistance: class D1 Casing airtightness: class L1 Filter bypass leak: class F9 Thermal transmittance: class T2 Thermal bridge factor: class TB2 2

The diagrams show the standard compositions with the usage limit corresponding to the components. - Air heater (A). - air conditioner without droplet separator (B). - With drain screen separator (C). - With blade-type separator (D) 2812 A 2172 2812 2172 2172 1817 2172 39CZ 190 1512 39CZ 140 2172 1516 39CZ 150 946 1236 39CZ 200 1566 39CZ 250 1566 39CZ 300 1566 39CZ 375 1886 39CZ 400 1566 39CZ 450 1236 2226 39CZ 600 2226 B C D 39CZ 25 39CZ 50 39CZ 75 39CZ 100 1516 1185 875 875 865 593 946 865 Coil section air speed 3

Description Casing - Double-skin panels, with 50 mm long fibre mineral wool insulation, reinforced with bonded glass fibre canvas, - Assembled edge casing or stainless steel support feet, - Depending on the size, double-skin panels, galvanised, lacquered, smooth internal walls and devoid of protruding screws in accordance with EN 13053. Construction structure depending on AHU sizes. - Sizes 25 to 75: self-supporting panels with aluminium vertical uprights. - Sizes 100 to 150: panels screwed onto an aluminium structure sunk into the casing. - Sizes 200 to 600: panels screwed onto an aluminium double honeycomb structure offering high resistance to flexing. - Air handling units consist of multi-block components or, mono-block components if the composition and size allow. - All of our blocks can be disassembled on the installation site. At least one removable panel per function in accordance with EN 13053, access panel as standard on functions requiring maintenance. Lift-off panels on offset hinges, equipped with slow closing latches in composite material, polyamide handles, large section square porthole in accordance with EN 13053. OPTIONS AVAILABLE PER RANGE 39CZ ST 39CZ CL & HE Adjustable support feet + 35/+ 60 mm Support feet risers up to 400 mm Stainless steel ground insulation casing (h: 100) Epoxy or polyurethane paint on int. and ext. panels Int. and ext. panels in pre-painted RAL 9010 sheet metal standard Int. and ext. panels in 304 L stainless steel or Z3CN 18.10 Flat stainless steel base Inclined stainless steel base (per block) Reinforced insulation Roof for OUTDOOR model Screened canopies for OUTDOOR model Damper - Isolation damper - Safety damper (CH38) - Control damper All the dampers consist of airfoil blades, counter rotating with lateral seals and driven by toothed wheels or control rods. Steel frame and aluminium blades on 39CZ ST CL & HE Class 3 in accordance with EN1751. These dampers are installed on the inside or outside of the casing, depending on the solution chosen. Louvre control: manual, motorised or to be motorised. Servomotor kit kit Mechanism electric heaters < 25 C Toothed wheels standard standard Control rods Class 4 sealing in accordance with EN 1751 Polyurethane frame paint standard Polyurethane or epoxy paint on louvres and frames Frame and dampers in stainless steel sheet 4

Boxes Air intake boxes (AHU intake) Single air intake, mixing, economiser mixing. Air discharge box (AHU discharge) Directional, distribution. Assembly of combined louvres outside or inside the casing for the task defined by the section chosen. Manual control, motorised or to be motorised. OPTIONS AVAILABLE PER RANGE 39 CZ ST 39 CZ CL&HE Servomotor kit kit Mechanism electric heaters for fresh air at a temperature < 25 C Toothed wheels standard standard Control rods Class 4 sealing in accordance with EN 1751 Galvanised safety base with drain Stainless steel sheet safety base with drain Polyurethane or epoxy paint on louvres and frames Lighting not connected (if access provided) kit kit Lighting wired to switch (if access provided) Double glass porthole Lift-off panel (louvre control on opposite side) Hinged door (louvre control on opposite side) Filters - G2 & G4 efficiency, M5 to F9, H10 to H14 or activated carbon with international dimensions mounted on compressible tracks, on universal frame or large-media frames with pressure tappings on each filtration stage, EN 1886 Filter bypass leak classification (F9 classification). - Fitting system equipment for filter cells for all 3 ranges. - Filter cells with international dimensions 24 x 24 and 12 x 24. - Efficiency classification in accordance with EN 779 from G2 to F9. - Efficiency classification in accordance with EN 1822 from H10 to H14. 4 Standardised assembly systems Assembly 0: traditional tracks for full section G4 cells. Assembly 1: compressible tracks (horizontal extension), G2 and G4 efficiency, 65 to 90% gravimetric (GRAVI) efficiency with side door. Assembly 2: compressible tracks (horizontal and vertical extension), M5 to F9 efficiency, 40 to 98% opacimetric (OPA) efficiency with side door. Assembly 3: 3U universal frames or 3B large-media frames, M5 to H10 efficiency for universal frames, 40% OPA to 85% MPPS efficiency, H10 to H14 efficiency for large-media frames, 85 to 99.995% MPPS efficiency. Activated carbon: a model with activated carbon cells for urban pollution can also be installed in assembly 2 or 3 (universal frame); another for specific pollution must be installed in a large-media frame. ASSEMBLY 0 1 2 3U 3B F1 efficiency G2 F2 efficiency G4 F3 efficiency G4 HEP efficiency M6/F7 HPS efficiency M5/F8 FHPS efficiency G4 + F6/F8 HPR efficiency M5/F9 HPR efficiency H10 H10 to H14 HPR CARB urban pollution CARBOC specific pollution 5

Name of filters selected Application CARRIER Construction material Classification Efficiency Construction Frame Medium Prefilter F1 Galv. Galv. or stainless G2 Gravimetric 65% Flat filter steel F2 Synthetic G4 90% pleated filter F3 G4 90% short bag High efficiency filter HEP1 Fibreglass M6 Opacimetric 65% pleated filter HEP2 F7 85% HEP3 F8 95% M5 Fibreglass or M5 < 65% Short or long bag HPS1 synthetic M6 65% HPS2 F7 85% HPS3 F8 95% FHPS1 Synthetic G4+M6 90% Grav + 65% Opa FHPS2 G4+F7 90% Grav + 85% Opa FHPS3 G4+F8 90% Grav + 90% Opa HPR1 Polypropylene +ABS Fibreglass M6 65% Deep smooth dihedral HPR2 F7 85% HPR3 F8 95% HPR4 F9 98% Absolute filter HPR H10 E10 EPA 85% MPPS H10 ABS E10 85% MPPS H12 E12 99.5 % MPPS H13 H13 99.95% MPPS H14 H14 99.995% MPPS Activated HPR CARB Polypropylene Synthetic Urban pollution Deep dihedral carbon filter CARBOC Galv. Nonwoven + Specific pollution Dihedral carbon squares carbon Lift-off panel or hinged door Galvanised safety container Stainless steel safety container Pressure tappings per filter stage standard standard Liquid pressure gauge kit kit Contact pressure gauge kit kit Magnehelic pressure gauge kit or assembled kit or assembled Double glass porthole Lighting not connected kit kit Lighting wired to switch Door contact kit or assembled assembled Polyurethane or epoxy paint on tracks and frames Paint on frame: standard polyurethane Stainless steel tracks standard Stainless steel universal frame ( F fine filters) Stainless steel large-media frame (HEPA H filters) Pressurised door (assembly 3 downstream of the fan) standard standard Opening for DOP injection/hatch for DOP measurement 6

Heating coil For hot water - Construction with copper tubes and aluminium fins. - Primary fluid maximum T = 120 C. - Operating pressure for water: 8 bar as standard - Higher pressures on consultation. Depending on the type of coil and the diameters required, the manifolds and supply tubes are: - Copper or steel tubes with unions up to 3 diameter. - Steel tubes with smooth ends for larger diameters. - Removable sealing flanges between the casing and manifolds (up to 3 diameter prevent damage to the sealing system during connection operations). For refrigerant fluid - Construction with steel tubes and aluminium fins. - Supply tubes made from copper with smooth ends. For steam (on consultation) - Low pressure < 2 bar - copper tubes, aluminium fins. - High pressure 2 to 8 bar - cupronickel or stainless steel tubes depending on the size of the AHU, the pressure and the steam quality. - Supply manifolds and tubes made from steel or stainless steel with smooth ends. For superheated water - Construction with steel tubes and aluminium fins. - Primary fluid maximum T = 200 C. - Operating pressure for water: 30 bar max. - Supply manifolds and tubes made from steel with smooth ends. Hot water coil in stock Standard circuit coil Superheated water coil Steam coil Condensation coil Antifreeze probe slide Frost protection thermostat supplied in a kit Frost protection thermostat supplied mounted Pressure tappings, upstream and downstream Precoated fins/primary fluid max. T 110 C Coil with ALTENA treatment max. T 160 C Coil with HERESITE treatment max. T 180 C Copper fins Galvanised steel safety container Stainless steel safety container Epoxy paint on tracks standard Stainless steel tracks Stainless steel coil panels Screw flanges and counter-flanges kit kit Tubes with quick connections Electric heater - Shielded resistors in stainless steel scrolled finned pipes - Connected to copper strips. - Double insulation assembly. - Safety thermostat with automatic and manual reset as standard. - To commission the heater: refer to the manual supplied with each unit. - Take the necessary precautions to prevent abnormal heating when the fan is switched off (ensure post ventilation). Safety thermostat with automatic reset standard standard Three-phase or single-phase connection Painted tracks standard Stainless steel tracks Stainless steel heater panels 7

Cooling coil Inclined condensate drain pan in accordance with EN 13053, Chilled water - Construction with copper tubes and aluminium fins. - Operating pressure for water: 8 bar as standard - Higher pressures on consultation. - Inclined condensate drain pan with drain pipes to be connected to a siphon on site. - Droplet separator as standard if necessary, as an option on request. Depending on the type of coil and the diameters required, the manifolds and supply tubes are: - Copper or steel tubes with unions up to 3 diameter. - Steel tubes with smooth ends for larger diameters. - Removable sealing flanges between the casing and manifolds up to 3 diameter prevent damage to the sealing system during connection operations. Direct expansion evaporation - Construction with copper tubes and aluminium fins. - Inclined condensate drain pan with drain pipes to be connected to a siphon on site. - Droplet separator as standard if necessary, as an option on request. - Standard smooth copper refrigerant supply tubes (supplied capped) - Manifold on fluid intake as standard. - Removable panel for accessing the expansion valve and solenoid valve incorporated in the casing (the valve and solenoid valve may be supplied assembled if the coil is connected to a CARRIER condensation unit). Chilled water coil in stock Standard circuit chilled water coil Direct expansion evaporation coil Access panel on droplet separator as standard if compulsory Pressure tappings, upstream and downstream Precoated fins Coil with ALTENA treatment Coil with HERESITE treatment Copper fins Stainless tube exchanger, aluminium fins Stainless steel condensate drain pan standard Heat insulation of pan, elbows and manifolds Painted tracks standard Stainless steel tracks Hygiene pan standard on HE Stainless steel heater panels Fully galvanised droplet separator as standard if compulsory Droplet separator with galvanised frame, stainless steel medium 100% stainless steel droplet separator, frame and medium as standard if compulsory Droplet separator with polypropylene blades as standard if compulsory Screw flanges and counter-flanges kit kit Tubes with quick connections 8

Adiabatic humidifiers Spray - Efficiency 80 to 90% - Stainless steel module with inclined base, door for inspection, maintenance and replacement of the drain screens and droplet separator. - 2 or 3 spray rails (depending on efficiency). - Drain screens. - Water tank with its supply equipment. 400 V three-phase pump and recirculation accessories Double glass porthole standard Lighting not connected kit kit Lighting connected on switch Droplet separator with galvanised frame with stainless steel mesh standard Fully stainless steel droplet separator Water tank pan spray washer Hydraulic connection for UV treatment of recirculated water Steam humidifiers Without steam production The supply includes: - Stainless steel steam distributor - Permissible steam pressure range (0.2 to 3.5 bar) - Cast iron steam/water separator - Main steam valve - 24 V or 240 V on/off or progressive servomotor Galvanised steel safety container Stainless steel safety container Fully galvanised droplet separator Droplet separator with galvanised frame, stainless steel mesh Fully stainless steel droplet separator Double glass porthole Lighting not connected kit kit Lighting connected on switch Lift-off panel With steam production (standalone with electrodes) The supply includes: - Aluminium steam distributor. - Steamer with electrical cabinet and controller (IP 33). - Proportional or on/off control. - Humidity controller or control sensor. - Duct/cylinder connection. - Condensate return tubes and connections. - 230 V single-phase or 400 V - 415 V three-phase supply voltage. - Min and max supply water conductivity limits 125-1250 microsiemens /cm (8000-800 ohm). - Hardness of supply water 15-30 degrees (French). Galvanised safety container Stainless steel safety container Fully galvanised droplet separator Droplet separator with galvanised frame, stainless steel mesh Fully stainless steel droplet separator Double glass porthole Standard Lighting not connected kit kit Lighting connected on switch Standard Lift-off panel With steam production (standalone with heaters) on consultation 9

Fans - Forward-curved dual-inlet fan. - Backward-curved dual-inlet fan. - Plug fan. - EC plug fan. - Steel scroll and impeller. - Assembly on anti-vibration frame. - Connection via internal flexible sleeve. - Ball bearings mounted in fan inlets. - Belt and pulley transmission on the dual-inlet fans. - Standard motor: asynchronous three-phase, 230/400 V - 50 Hz up to 4 kw - 400 V - 50 Hz from 5.5 kw, IP 55 protection, class F with PTC. - Inspection hatch with bolts in compliance with the MECHANICAL SAFETY specification in the EN 1886 standard and the machinery directive. Fan with forward-curved blades and transmission Fan with backward-curved blades and transmission Plug fan standard EC plug fan Sparkproof fan Spring mounts standard standard Lift-off panel Hinged door standard standard Pressurised door (plug fan), hinged for sizes > 250 standard standard Pressure connections Holes with blanking covers Door contact kit or assembled kit or assembled Galvanised steel safety container Stainless steel safety container Double glass porthole Smoke detector (NF S61961) kit kit Lighting not connected kit kit Lighting connected on switch Paint on casing and bracket standard Stainless steel casing, bracket Inspection hatch and vent on scroll Epoxy painted scroll and impeller standard Screens on inlets Door protection Belt housing 2 motors fitted Heat recovery unit Plate - Standard construction or HEE plate heat recovery unit. - The heat exchanger has aluminium plates. This component can be used normally up to an air temperature of 150 C (if the plate heat recovery unit is an AHU component, the standard temperature limit is 80 C with a differential pressure of 1000 Pa and a leak flow rate between the 2 air streams (EHAUST/INTAKE) of less than 1%. - Condensate drain pan on exhaust air side, made from galvanised steel with condensate drain piping as standard. For stacked AHUs For adjacent AHUs G4 prefilter and M5 filter incorporated depending on size Bypass on fresh air Coated aluminium plates Epoxy paint on internal panels Pressure tapping on the 4 air handling orifices Stainless steel condensate drain pan Damper control, manual, motorised or ready to be motorised 10

Heat pipe (gravity type) - Constructed in the same way as a coil with several rows of finned tubes; the assembly is mounted in a casing with an intermediate partition separating the cooling and heating areas. - Standard construction: copper tubes, aluminium fins, galvanised steel casing. - Transfer fluid: refrigerant, operation from 25 to +50 C. - Assembly in either vertical, fixed horizontal or mobile horizontal position on shaft. For stacked or adjacent AHUs Bypass on fresh air or exhaust air Sensor, controller, servomotor for mobile model Precoated fins Fins with ALTENA treatment Fins with HERESITE treatment Stainless steel heater panels Stainless steel condensate drain pan Pressure tapping on the 4 air handling orifices Rotary - Corrugated aluminium exchange medium. - Adjustable midway and peripheral gasket to guarantee a minimum leak flow rate. - Lateral inspection panel. - Constant speed gear motor (230/400 V three-phase power supply). - Maintenance-free ball bearing. - For sensible power exchange as standard. Gear motor and variable frequency drive for variable speeds from 0 to 10 rpm 230 V single-phase Coated aluminium rotor Hygroscopic rotor for total power exchange Polyurethane or epoxy painted internal panels Stainless steel internal panels Pressure tapping on the 4 air handling orifices Sound attenuators - Baffles. - Mineral wool of different densities, the faces are covered with an anti-erosion shield. - Galvanised panels. Baffle length 500-900 - 1200-1500 Coating with fray-resistant fabric standard Painted mounting tracks standard Painted baffle panels standard Stainless steel baffle panels Accessories Standard flexible sleeves for the outside of the casing Insulated flexible sleeves for the outside of the casing Rain protection frame with bird screen Grille frame for protection of the air handling orifices on AHUs 11

Block and AHU dimensions Table of "L" block lengths available (all integrated elements), the total length of the AHUs is obtained by adding 25 mm to each end. Unit No. 25 to 50 75 100 to 450 400 & 600 block/ahu length «L» maximum length L2 200 L3 300 L4 400 L5 500 L6 600 L7 700 L8 800 L9 900 L10 1000 L11 1100 L12 1200 L13 1300 L14 1400 L15 1500 L16 1600 L17 1700 L18 1800 L19 1900 L20 2000 L21 2100 75 L22 2200 2200 2200 2200 400 & 600 L23 2300 2300 2300 25 to 50 L24 2400 2400 L25 2500 L26 2600 L27 2700 L28 2800 L29 2900 L30 3000 L31 3100 100 to 450 L32 3200 AHU dimensions L length of integrated elements Le1 length of integrated elements + 1 end panel Le 2 length of integrated elements + 2 end panels Unit No. 25 50 75 100 150 140 200 190 250 300 375 400 450 600 A 593 865 865 946 1236 946 1566 1236 1566 1566 1886 1566 2226 2226 A1 693 965 965 1046 1336 1046 1666 1336 1666 1668 1986 1666 2326 2326 B 875 875 1185 1516 1516 2172 1516 2172 1817 2172 2172 2812 2172 2812 12

Connection flanges Fan discharge Central intake Mixing intake Unit No. 25 50 75 100 150 140 200 190 250 300 375 400 450 600 C 299 415 464 514 574 514 724 574 814 914 1024 914 1144 1144 D 299 415 464 514 574 514 724 574 814 914 1024 914 1144 1144 E 610 610 910 1260 1260 1860 1260 1860 1560 1860 1860 2510 1860 2510 F 310 610 610 610 1010 610 1310 1010 1310 1310 1510 1310 1810 1810 G 160 310 310 310 410 310 610 410 610 610 760 610 910 910 13

Quality and Environment Management Systems Approval Order No.: 10137, 04.2016 - Supersedes order No.: New. Manufacturer reserves the right to change any product specifications without notice. Manufactured for Carrier in France. Printed in the European Union.