ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Similar documents
Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Corrosion protection Explosion protection

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

ATEX LABELLING FOR MOTORS AND GEAR UNITS

Explosion protected hydraulic products. Product overview industrial and mobile hydraulics

Table of contents. Technical informations > ATEX Page Technical informations Page Mechanically operated valves Page 13-06

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Load disconnect switch Series 8146/5-V11

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Hazardous Location Solutions for the Process Control Industry. UL CSA FM ATEX IECEx NEPSI INMETRO TR CU

VALIADIS S.A. HELLENIC MOTORS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Switches in conformity with ATEX directive

Extremely sturdy and corrosion-resistant Solenoid valves VOFC/VOFD and solenoid coils VACC. Selection and ordering

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Motors and drives for applications in explosive atmospheres

Sensor boxes SRBE Key features and product range overview

General Specifications DRV DRV-Exm DRV-Exd

Terminal Boxes Series 8125

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

The filling level sensors are designed in accordance to the following standards

Switches in conformity with ATEX directive

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

For mounting on subbase or footprint in accordance with CNOMO recommendation E 06620N Part numbers (and voltages) Voltage max. power consumption U nom

Intrinsically Safe Miniature Solenoid Valves

Latest news on explosion protection

Wolflite XT Rechargeable LED Handlamp

Fluid Control Solenoid Valves for Process Market

Protecta III. Acclaim. Curie Elite. Lomond. Evolution II. Nevis. NexLED. Sterling II. 800 Series. Micronex/Maxinex. Nexxus II.

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Ex m Solenoid Operator Type 0519

Modern Explosion Protection

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

Control Buttons / Switches for Panel Mounting Series 8003

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification

Plug and Socket Devices SolConeX 16 A Series 8570

BROCHURE. Low voltage motors and drives for applications in explosive atmospheres

8150 Series Terminal Boxes

EX-D ENCLOSURES AND DISTRIBUTIONS

Solenoid coils VACF Type codes

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

Engineering GREAT Solutions

97105 Inline. Ordering information. Technical data. Accessories See page 5

/2-way piston valves

Magnetic Switches for WEKA Visual Level Indicators Australian Version

Terminal Boxes TNCN. Explosion protection Marking

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

Operating Instructions

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

2/2 Solenoid Cartridge Valve, Size 6

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

CONTENTS 1 TOLERANCES AND STANDARDS Mechanical and electrical tolerances Standards 5 2 HOW TO PICK THE RIGHT ELECTRIC MOTOR 6

Leading the way in hazardous areas Features EATON

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

HERION SERIES Indirect solenoid actuated soft seal

97100 NAMUR. Technical data

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

EEX Line Spring-applied single-disc brake for potentially explosion hazardous areas

High voltage flameproof induction motors The simplest solution for hazardous environments

M-0. M-0... series control, monitoring and signalling devices. Ex e

Smart Valve Positioner 700 Series with HART Communication Protocol

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Control and Terminal Box Type A21-**-*****

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

Smart Valve Positioner 700 Series with HART Communication Protocol

Terminal Boxes in Stainless Steel SLS**.T

High-efficiency three-phase induction motors ATEX GAS - Zones 1 & 2 ATEX DUST - Zones 21 & 22. Technical catalogue en

Terminal Boxes Series 8125

Flameproof Enclosures

/2-way piston valves

BFG range BFGC range BFN range

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W

COMBUSTION AND ENERGY

Ex-proof ISO cartridge valves multicertification ATEX, IECEx, EAC or North American certification CULUS directional control, ISO 7368

IECEx Certificate of Conformity

Measuring insert for process resistance thermometer

ExBin-P Pressure switches 5 Pa Pa

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

Material pressure (bar) (Cv (US) kv x 1,2 Seat


CCAI, CCAIF, CCAIF..H

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Operating Instructions for Viscosity Compensated Flow Meter / Monitor. Model: VKM

Ex e, ia Junction boxes TNCN. Features

SKINNER Intrinsically Safe Series Four-Way

Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications.

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Linear fluorescent luminaire LED V-CG-S

Small centrifugal fans made of plastic

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Transcription:

EX-PROTECTION

ADVANTAGES Valves for fluid technology for use in explosion hazard areas Explosion protection for gas, dust and mining Flameproof enclosures and intrinsic safety Solutions for all zones The valves comply with the requirements according to: according to Directive 94 / 9 / EC and standard EN 60079 Ex according to standard 60079 GOST Ex according to standard MEK 60079 Wide product range Solenoid operated spool valves Poppet valves Proportional spool valves Proportional pressure valves Proportional flow valves Air + combustible gas + ignition source = explosion Air + combustible dust + ignition source = explosion

APPLICATIONS It is the climatic conditions which call for the use of explosion protected components, often together with high demands with respect to corrosion protection. As standard for - C + 70 C Optional for - 60 C + 70 C High corrosion protection as standard Versions with very high corrosion protection right up to rust and acid-resistant on request The complete certifications can be found under: www.wandfluh.com / Downloads / Certifications Explosion-protection ATEx Ex GOST Ex Australia Inmetro NEPSI -60 C

VALVES EX D Equipment according to ignition protection type flameproof / encapsulated housing Explosion protection designation acc. to Zones I M2 Ex d I Ex d I Mb II 2G Ex d IIC T4 / T6 Ex d IIC T4 / T6 Gb II 2D Ex td A21 IP65 T80 C / T130 C Ex tb IIIC IP65 T80 C / T130 C Db mines mines zones 1 and 2 zones 1 and 2 zones 21 and 22 zones 21 and 22 Type Type designation Data sheet no. Size Solenoid Solenoid operated spool valve direct operated MKY45 BEXd4x4 AEXd4x4 WDYFA06 1.1-183 1.3-23 1.3-33 1.3-34 Square 45 mm NG4-Mini Characteristic hydraulic values Q max [l/min] 20 50 80 P max [bar] Solenoid operated spool valve pilot operated AEXdVP4x10 1.9-37 NG10 100 315 Proportional spool valve WDBFA06 1.10-88 Solenoid poppet valve cartridge direct operated SDYPM22 1.11-2064 40 Solenoid poppet valve cartridge pilot operated SVYPM22 SVYPM33 1.11-2084 1.11-2085 M33x2 80 150 Solenoid poppet valve direct operated BEXd2204 AEXd2206 1.11-3132 1.11-3143 NG4-Mini 15 40 Pressure relief cartridge direct operated BDBPM22 2.3-547 Pressure relief cartridge pilot operated BVBPM22 2.3-536 100 Pressure reducing cartridge direct operated MDBPM16 MGBPM16 2.3-602 2.3-608 M16x1,5 M16x1,5 6 6 40 100 Pressure reducing cartridge pilot operated MVBPM22 2.3-635 60 Throttle cartridge D.BPM22 2.6-535 2-way flow control cartridge QNBPM22 2.6-634 3-way flow control cartridge QDBPM22 2.6-648

VALVES EX IA Equipment according to ignition protection type intrinsic safety Explosion protection designation acc. to Zones I M1 Ex ia I Ex ia I Ma II 1G Ex ia IIC T5/T6 Ex ia IIC T5/T6 Ga mines mines zones 0, 1 and 2 zones 0, 1 and 2 Type Type code Data sheet no. Size Solenoid Solenoid operated spool valve direct operated MKZ45 AEXi4x6 WDZFA06-Z546 1.1-185 1.3-40 1.3-42 Quadrat 45 mm Characteristic hydraulic values Q max [l/min] 20 5 p max [bar] 300 CERTIFICATIONS EX D Protection type: flameproof enclosure Ex d 1.1-183 Surface Gas + Dust Mining X * X Ex X * X GOST Ex X * Optional for - 60 C + 70 C for spool and poppet valves As standard for spool and poppet valves Other functions on request Australia X X Inmetro X X NEPSI X CERTIFICATIONS EX IA Protection type: intrinsic safety Ex ia 1.1-185 Surface Mining X X Ex X X

Designation of electrical equipment I M1 Ex ia I Ex ia I Ma II 1G Ex ia IIC T5/T6 Ex ia IIC T5/T6 Ga I M2 Ex d I Ex d I Mb II 2G Ex d IIC T4/T6 Ex d IIC T4/T6 Gb II 2D Ex td A21 IP65 T80 C/T130 C Ex tb IIIC IP65 T80 C/T130 C Db Zones dangerous explosive atmosphere Gas Dust continuously, frequently or long-term occasionally not likely to occur and for short periods only / / NEC 505 Zone 0 Zone 1 Zone 2 NEC 500 (Class I) Division 1 Division 2 / / NEC 505 Zone 20 Zone 21 Zone 22 NEC 500 (Class II, III) Division 1 Division 2 Zone 0 (20) includes zones 1 and 2 (21 and 22) ZONE 2 ZONE 0 ZONE 0 ZONE 1 acc. to Equipment group Equipment category and Equipment protection level (EPL) Equipment category mines susceptible to firedamp acc. to EPL sufficient security I M1 Ma during rare malfunctions I M2 Mb gas explosion hazard areas until de-energizing of the equipment II 1G Ga Zone 0 during rare malfunctions II 2G Gb Zone 1 during expected malfunctions II 3G Gc Zone 2 in normal operation Dust explosion hazard areas II 1D Da Zone 20 during rare malfunctions II 2D Db Zone 21 during expected malfunctions II 3D Dc Zone 22 in normal operation Type of protection IP Type of protection acc. to / EN 60529

Types of protection for electrical equipment in gas explosion hazard areas Type of protection Symbol Zone Diagram Standard increased safety e 1 60079-7 EN 60079-7 () flameproof enclosure d 1 60079-1 EN 60079-1 () intrinsic safety ia 0 60079-11 EN 60079-11 () encapsulation m 1 60079-18 EN 60079-18 () Types of protection for electrical equipment in areas with combustible dust Type of protection Symbol Zone Diagram Standard protection by enclosures tb 21 old identification: td A21 = under procedure A for zone 21 (EN 61241-1) 60079-31 EN 60079-31 () ZONE 20 ZONE 21 ZONE 22 Groups / / NEC 505 NEC 500 Group I mines susceptible to firedamp Methane Group II gas explosion hazard areas Class I subdivisions typical gas subdivisions IIA Propane Propane Class I Group D IIB Ethylene Ethylene Class I Group C IIC Hydrogen Hydrogen Class I Group B Acetylene Acetylene Class I Group A Group III dust explosion hazard areas Class II/III subdivisions typical dust subdivisions IIIA combustible flyings fibres and fluff Class III IIIB non-conductive dust non-conductive dust Class II Group G IIIC conductive dust carbonaceous dust Class II Group F combustible metal dust Subdivisions IIC (IIIC) include subdivisions IIA and IIB (IIIA and IIIB) Class II Group E Temperature classification Maximum surface temperature Temperature classes for gases Maximum surface Temperature classes for gases / / NEC 500 / 505 temperature / / NEC 500 / 505 450 C T1 200 C T3 300 C T2 135 C T4 For dusts: indication of the maximum surface temperature in C 100 C T5 85 C T6

Wandfluh AG Hydraulik + Elektronik Helkenstrasse 13 Postfach CH-3714 Frutigen Telefon +41 33 672 72 72 Telefax +41 33 672 72 82 sales@wandfluh.com www.wandfluh.com wandfluh.com