Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

Similar documents
Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA

Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices

Application. Gas Chromatography June 1995

Comprehensive Gas Chromatography (GCxGC) Analysis of High-Ethanol Containing Motor Fuels

Agilent and ASTM. Update on Recent Activities. Page 1

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

C2, C3, C4 Monomer Analysis

Operation and Applications of Differential Flow Modulation

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

Simple Heart Cutting with Deans. Capillary Flow Technolgy. Simon Jones Applications Engineer

Agilent Distributor News

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns

GC Method Compliance and Large Valve Oven Application

REFINED RESTEK. Detailed Hydrocarbon Analysis. innovative petrochemical solutions. Featuring Rtx -DHA Columns

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials

Beverage Grade Carbon Dioxide

Technical Procedure for Gas Chromatography (GC-FID)

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

ASTM D 6730 Detailed Hydrocarbon Analysis

Agilent G2855A Deans Switching System

Using the PSD for Backflushing on the Agilent 8890 GC System

GC Inlets. An Overview. Simon Jones GC Applications Engineer

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method

Agilent Multimode Inlet for Gas Chromatography

Restek Corporation 110 Benner Circle, Bellefonte, Pa Barry L. Burger, Neil Johansen, Valerie Gamble, Donald Rhoades

2-D GC/MS and the Deans Switch: Theory and Applications. Fred Feyerherm, Agilent Technologies Inc. Houston, Tx

Analysis of Glycerin and Glycerides in Biodiesel (B100) Using ASTM D6584 and EN Application. Author. Abstract. Introduction

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Agilent 9000 Intuvo GC Applications. Matthew Giardina, Ph.D. James McCurry, Ph.D. Rebecca Veeneman, Ph. D.

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

Application Note. Abstract. Authors. Environmental Analysis

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons Gases

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

performance productivity reliability

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

Application Note. Author. Introduction. Energy and Fuels

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

炭化水素 - 直鎖炭化水素 炭化水素 - 炭化水素及びアルコール類

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

Antek Gas Chromatography Products: A Guided Tour Through Industry

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Productivity Improvements for Dual Column Applications: USP <467> and Blood Alcohol Analysis

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Forensic Blood Alcohol Determination with the Intuvo 9000 GC

Analysis of Petroleum Fractions by ASTM D2887

Going Green: The Analysis of BioFuels

Complete Fractionation of Extractable Petroleum Hydrocarbons Using Newly Developed EPH SPE Cartridges

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Live Crude Oil Volatility

DETERMINATION OF N-BUTANOL AND ISOBUTANOL IN GASOLINE USING GAS CHROMATOGRAPHY (GC-FID)

Installing a Purged Packed Inlet

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

High-Temperature Simulated Distillation System Based on the 6890N GC Application

CP-3800 GAS CHROMATOGRAPH

Agilent 6850 Series II Network GC System G2630A Performance Specifications

DANI Transformer Oil Gas Analyzer

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

S-PRO 3200 GC System for Sulfur Analysis

ASTM D for Denatured Fuel Ethanol Automating Calculations and Reports with Empower 2 Software

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

ASTM. Internal Standard M-GRA-IS-AS-5ML $ 20 / 1 x 5 ml M-GRA-IS-AS-5ML-PAK SAVE 20% $ 80 / 5 x 5 ml. 2-Hexanone (Neat) Selectivity Check Standard

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Live Crude Oil Volatility

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

Same Column and Gas Type Try Different/Faster Velocities. Same Column, Switch He to H2 Carrier Then Try Faster Velocities

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

DETECTORS Photo Ionization Detector - PID. Overview

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

Typical Gas Chromatographic System

Setting up SilFlow for BackFlush in your GC

I SO9001 I SO14001 CE

Method Development for Capillary GC Systems. Slide 1

New Specialized GC Columns for the Petroleum Industry -Integrated Particle Trap PLOTs -DB-Sulfur SCD

Meeting the Requirements of ASTM D ( IP548/06 ) with Agilent 1200 LC Systems

6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR

Agilent Multimode Inlet

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

MET-Biodiesel Capillary GC Columns

Oil & Gas Application Notebook

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Techniques for Improving the Reproducibility of GC Analysis

Transcription:

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels James D. McCurry Senior Scientist Agilent Technologies Wilmington, DE USA Page 1

Application Summary There is a need to measure trace oxygenates in: Feedstocks Example: denatured fuel ethanol Intermediates Example: ethers and alcohols in light hydrocarbons (C 2 to C 5 ) Final Products at Distribution Example: ethers and alcohols in reformulated gasoline Gasoline Oil Fields Shipping Ctrs Crude Oil Refineries Gasoline Jet Fuel Diesel Fuel Oil Distribution Centers Fuel Oil Diesel Page 3

ASTM Methods for Trace Oxygenates Three recently developed methods ASTM D7059-09 Standard Test Method for Determination of Methanol in Crude Oils by Multidimensional GC Method scope: 15 mg/kg to 900 mg/kg ASTM D7423-09 Standard Test Method for Determination of Oxygenates in C2, C3, C4, and C5 Hydrocarbon Matrices by GC and FID Method scope: 0.5 mg/kg to 100 mg/kg Proposed Gasoline Method - Standard Test Method for Determination of Trace Oxygenates in Finished Gasoline by Multidimensional GC Method scope: 10 mg/kg to 1000 mg/kg in gasoline containing 1 15 wt% ethanol Page 4

Each ASTM Methods Uses the Same Approach for Oxygenate Analysis Problem is to separate and detect ppm level oxygenates from many hydrocarbons in the sample matrix Approach: Use oxygenate selective column combined with 2-D GC LowOX and GS-OxyPLOT has strong retention for oxygen containing compounds High boiling and polar hydrocarbons (aromatics) can still interfere Use 2-D GC to eliminate these interfering hydrocarbons All three ASTM methods two optional hardware configurations for 2-D GC Rotary valve based Fluidic Switch (Deans switch) Page 5

Typical GC Conditions For 2-D GC Analysis of Trace Oxygenates in Hydrocarbons Column 1: DB-1 (Valve) or HP-5 (Fluidic Switch) 30m x 0.53mm x 1um Column 2: Oxy-PLOT or LowOX 10m x 0.53mm Carrier gas: Helium Injection volume:1 ul Inlet: Split/splitless Temperature: 225 o C Split Ratio: 10:1 Oven Initial temp Initial hold Ramp rate: Final temp Detector: FID Temperature 50 o C 5 min 10 o C/min 240 o C 275 o C Note: GC analyzer conditions will vary depending on sample matrix type and type of Valve or Fluidic Switch configuration is being utilized. Page 6

Rotary Valve Configuration For ASTM Trace Oxygenate Analysis Methods Transfer of Oxygenates Valve Off Venting Hydrocarbons Valve On S/Sl Inlet Vent AUX EPC S/Sl Inlet Vent AUX EPC 1 1 Non-polar column 2 Off 3 4 Non-Polar Column 2 On 3 4 Oxygen Column Back FID Oxygen Column Back FID Page 7

ASTM D7059 Valve Configuration for Gas or Liquified Gas Sample Introduction Liquid Sample Gas Sample 1 ml 2 µl Restrictor DB-1 Column Oxygen Column Page 8

Separation of Oxygenates in Light Hydrocarbon Stream Using Valve Configuration Benzene Isooctane Critical ethers shows good separation and peak shape 8 2 5 6 n-octane 3 4 9 12 21,22,23 Back flush occurs here 7 10 11 13 14 15 17 18 19 20 1 16 24 25 Page 9

Compound I.D. 1. Dimethyl ether 2. Diethyl ether 3. Acetaldehyde 4. Ethyl t-butyl ether 5. Methyl t-butyl ether 6. Diisopropyl ether 7. Propionaldehyde 8. Tert-amyl methyl ether 9. Propyl ether 10. Isobutylaldhyde 11. Butylaldehyde 12. Methanol 13. Acetone 14. Isovaleraldehyde 15. Valeradehyde 16. MEK 17. Ethanol 18. n-propanol 19. Isopropyl Alcohol 20. Allyl Alcohol 21. Isobutyl Alcohol 22. t-butyl Alcohol 23. s-butyl Alcohol 24. n-butyl Alcohol 25. 2-Methyl-2-pentanol Page 10

Analysis of Oxygenates in Reformulated Gasoline Using Valve Configuration 500 mg/kg oxygenates in reformulated gasoline pa FID1 A, FID1A, Front Signal (E:\LFS_JAN2007\7890\OXYGENATES_OXYPLOT\OXYCAL3 2007-01-26 10-59-37\OXYCAL3000006.D) 90 80 70 1 2 3 4 12 wt% Ethanol 7 9 60 50 6 8 40 30 20 5 1,2-Dimethyoxy Ethane (ISTD) 12 14 16 18 20 22 24 26 min Ethers 1. EtBE 2. MtBE 3. DIPE 4. TAME Alcohols 5. methanol 6. i,n-propanols 7. i,s,t-butanols 8. n-butanol 9. tert-amyl alcohol Page 11

Analysis of Oxygenates in Reformulated Gasoline Using Valve Configuration 50 mg/kg oxygenates in reformulated gasoline pa FID1 A, FID1A, Front Signal (E:\LFS_JAN2007\7890\OXYGENATES_OXYPLOT\OXYCAL3 2007-01-26 10-59-37\OXYCAL3000007.D) 28 26 1 wt% Ethanol 24 22 20 1 23 4 5 6 7 8 9 1,2 -Dimethoxy Ethane (ISTD) 18 16 12 14 16 18 20 22 24 26 min Ethers 1. EtBE 2. MtBE 3. DIPE 4. TAME Alcohols 5. methanol 6. i,n-propanols 7. i,s,t-butanols 8. n-butanol 9. tert-amyl alcohol Page 12

Ethanol Concentration Shifts Retention Time of Early Peaks 12 wt% ethanol 1 wt% ethanol 12 14 16 18 20 22 24 min. ETBE 12.498 MTBE 12.660 DIPE 12.789 TAME 13.755 MeOH 15.463 12.753 13.852 12.601 12.886 15.687 12 12.5 13 13.5 14 14.5 15 15.5 min Page 13

Fluidic Switch Configuration For ASTM Trace Oxygenate Analysis Methods 1. A. The HP-5 and the Oxygen columns are linked by Capillary Flow Technology (CFT) B. The Inlet EPC delivers 2.7 ml/min to both columns C. The Aux EPC delivers 0.3 ml/min to the Capillary Flow Technology Plate. This increases the flow to the Oxygen column to 3.0 ml/min. 1. Sample injected Oven Temp: 50 C Aux HP-5 Column A Oxygen Column EPC S/S Inlet CFT Switch 2.7 ml/min 3.0 ml/min FID B C C 0.3 ml/min Page 14

Fluidic Switch Operation For ASTM Trace Oxygenate Analysis Methods 2. A. Oxygenates and low boiling point hydrocarbons elute into Oxygen Column Oxygenates are trapped at the front of the GS-OxyPLOT B. High boiling point compounds are retained in HP-5 C. Low boiling point hydrocarbons elute unretained through Oxygen to the FID Aux Oven Temp: 50 C for 5 minutes B A C EPC S/S Inlet CFT Switch 2.7 ml/min 3.0 ml/min FID 0.3 ml/min Page 15

Fluidic Switch Operation For ASTM Trace Oxygenate Analysis Methods 3. Inlet EPC flow reduced to 0.5 ml/min and AUX EPC flow increased to 8 ml/min 4. Gas flow through the Fluidic Switch back flushes the HP-5 to send high boiling compounds out the inlet split vent. 5. Oven temperature program begins and oxygenates are separated on the Oxygen Column to the FID. Split vent Oven Ramp: 10 o C/min to 240 o C Aux HP-5 Column OxygenColumn EPC S/S Inlet CFT Switch 5.0 ml/min 3.0 ml/min FID 8.0 ml/min Page 16

Oxygenate Analysis in Hydrocarbons Using Capillary Flow Technology Fluidic Switch HP-5 Column CFT Plate AUX EPC Line Oxygen Column Page 17

Analysis of Oxygenates in Reformuated Gasoline Using CFT Fluidic Switch Light Hydrocarbons Ethanol Ethers Methanol C3 to C5 Alcohols 5 10 15 20 25 min. ETBE DIPE MTBE TAME MeOH i,n-propanol t,s,i-butanol n-butanol t-pentanol 1,2-DME(IS) 12.5 13.5 14.5 15.5 min 22 23 24 25 26 27 min Page 18

Excellent Quantitative Precision High Concentration QA/QC Check Sample Expected Avg Std Dev RSD (ppm)* (ppm)* (ppm)* ETBE 780 758 1.3 0.2% MTBE 795 816 1.5 0.2% DIPE 795 758 1.1 0.2% TAME 779 779 1.4 0.2% Methanol 802 759 1.6 0.2% Ethanol* 12.0% 11.3% 0.0 0.4% i,n-propanol 1619 1566 14.7 0.9% t,s,i-butanol 2399 2372 4.4 0.2% n-butanol 798 791 1.7 0.2% t-pentanol 801 766 0.6 0.1% *ethanol results are in wt% Low Concentration QA/QC Check Sample Expected Avg Std Dev RSD (ppm)* (ppm)* (ppm)* ETBE 49 48 0.7 1.4% MTBE 49 46 1.0 2.1% DIPE 49 93 0.7 0.8% TAME 48 48 0.3 0.6% Methanol 50 67 0.6 0.8% Ethanol* 1.0% 0.9% 0.0 2.2% i,n-propanol 101 95 1.3 1.4% t,s,i-butanol 150 152 2.4 1.6% n-butanol 50 47 0.8 1.6% t-pentanol 50 47 0.2 0.5% Each QA/QC sample prepared in reformulated gasoline Five consecutive runs of each sample Page 19

Feedstock and Ethanol Fuel Analysis ASTM D5501-09 ASTM D4806 - Denatured Fuel Ethanol for Blending with Gasoline Property Specification ASTM Test Method Minimum ethanol content 92.1 vol % D5501-09 Maximum methanol content 0.5 vol% D5501-09 ASTM D5798 Standard Specification for Fuel Ethanol (E75-E85) Property Specification ASTM Test Method Minimum ethanol content 70 79 vol % D5501 Maximum methanol content 0.5 vol% None 20

ASTM Method D5501-09 Agilent 7890A GC Instrument Conditions Method Scope 93 to 98 wt% ethanol 0.01 to 0.6 wt% methanol Column and Oven Temperature Column PDMS, 150 m x 0.25mm x 1.0 um Carrier gas Helium at 2.3 ml/min Initial Oven Temp 60 o C Initial Hold Time 15 min. Oven Ramp Rate 30 o C/min Final Temp 250 o C Final Hold Time 23 min. Split/Spltless Inlet Mode Split Mode Split ratio 200:1 Temp 300 o C Injection Size 0.5 ul Flame Ionization Detector Temp 300 o C 21

ASTM D5501-09 7890A GC Calibration 7 Levels of calibration Heptane range: 1.95 to 7.4 wt% Methanol range: 0.05 to 0.6 wt% Ethanol range: 92 to 98 wt% Use average RRF for sample quantification n-heptane methanol ethanol Relative response factor Relative response factor Relative response factor 1.00 2.97 2.06 22

ASTM Method D5501-09 Commercial Denatured Fuel Ethanol Sample pa 90 80 ethanol 13.58 min 70 60 50 40 30 20 methanol 11.54 min 10 10 15 20 25 30 35 40 Min. 23

D5501-09 Potential Methanol Interference pa 13.5 Peak integration not optimized 13 12.5 12 11.5 methanol C 4 hydrocarbons 11 pa 13.5 13 12.5 12 11.5 11 11.9 12 12.1 12.2 12.3 12.4 Peak integration optimized C 4 hydrocarbons methanol 11.9 12 12.1 12.2 12.3 12.4 min min 24

ASTM D5501-09 Agilent 7890A GC Analysis Precision Commercially available denatured fuel ethanol sample Run methanol ethanol 1 0.02 97.81 2 0.02 97.83 3 0.02 97.81 4 0.02 97.82 5 0.02 97.79 6 0.02 97.81 7 0.02 97.78 8 0.02 97.76 9 0.02 97.77 10 0.02 97.74 Avg 0.02 97.79 STDDEV 2.18e-4 0.03 RSD 1.16% 0.03% 25

Summary Agilent Special Products for ASTM oxygenate analysis methods ASTM D7423-09 Standard Test Method for Determination of Oxygenates in C2, C3, C4, and C5 Hydrocarbon Matrices by GC and FID Proposed Gasoline Method - Standard Test Method for Determination of Trace Oxygenates in Finished Gasoline by Multidimensional GC ASTM D5501 - Standard Test Method for Determination of Ethanol Content of Denatured Fuel Ethanol by Gas Chromatography Preconfigured solutions based on Agilent 7890A GC platform Factory configured and tested to meet ASTM performance specifications Page 26