Flowmeter for Gases. Type Type can be combined with... Type 8802-YG Process control valve. Type 5281 Solenoid valve

Similar documents
Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

2/2 way Angle-Seat Valve for medium up to C, DN15-50

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Flow VA 550 / 570. DVGW tested. Flow.

2/2-way Globe Valve for media up to +180 C, DN

2/2-way Globe Valve for media up to +180 C, DN

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

INSERTION flowmeter with paddle wheel, ELEMENT design

2/2 or 3/2 way direct acting rocker solenoid valve

INSERTION flow sensor for continuous flow measurement

Insertion magnetic inductive flowmeter

3/2-way Solenoid Valve for pneumatics

2/2-way Diaphragm Valve with stainless steel design, weld end or clamp connection, DN 8-25

Inline Paddle Wheel Flow Switch

2/2-way Angle-Seat Control Valve with stainless steel design for media up to +185ºC, DN15-65

Pneumatically operated zero dead volume T-Valve CLASSIC

Flow Controller, flow control system for gases

2/2-way-Globe Valve with stainless steel design for media up to +180ºC, DN 13-50

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Paddle-wheel flow controller for On/Off control

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

2/2-way Globe Control Valve with stainless steel design for media up to +185ºC, DN

Paddle-wheel flow controller with optical principle for On/Off control

Positive displacement flowmeter for continuous flow measurement

INSERTION Adaptor for analysis

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

2/2 or 3/2 way direct acting rocker solenoid valve

Cable Plug acc. to DIN EN , Form A

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems

Inductive conductivity meter

Flow-rate curves for diaphragm valves Type 2730 plastic, 2731 forged, 2731 cast, 2731 GP cold formed pipe valve body

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Modular pneumatic valve unit

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

2/2-way Diaphragm Valve, forged valve body, weld end and clamp connection, DN 8-100

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

AirLINE and AirLINE Quick electrical/pneumatic Automation System

Inductive conductivity meter

Tandem valve, welded valve configuration

Positive displacement flowmeter

Direct-acting 2/2- or 3/2-way pivoted armature valve

Pneumatically operated zero dead volume T-valve ELEMENT for decentralized automation

2/2-way Globe Control Valve, threaded port connection, DN 10-65

Differential-Pressure Flow Meter

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Ball Valves in cast 316 SS multi-port, bolted construction

INLINE sensor-fitting with paddle wheel for flow measurement

Paddle-wheel flow controller for On/Off control

2/2-way Angle-Seat Control Valve with stainless steel design for media up to +180ºC, DN 13-50

Remote Process Actuation Control System AirLINE - Siemens ET 200S

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Type Pressure Transmitter with display. Pressure Transmitter. Technical data. DN15-50 Body material. Stainless steel 316L Actuator material

2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid

mass flowmeter for compressed air

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

3/2-way Solenoid Valve, direct-acting, NC or NO

2/2- and 3/2-way solenoid valve for aggressive fluids

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Pneumatic control unit for decentralized automation of ELEMENT process valves

English. Instruction and operation manual S 430. Pitot tube flow sensor

Direct-acting 3/2 way plunger valve

TopControl Continuous

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

Direct-acting 2/2-way plunger valve

INLINE fitting with paddle-wheel for flow measurement

Positive displacement batch controller

Compressed Air-Supply Meter

Modular pneumatic valve unit

Pressure transmitter for industrial applications Type MBS 4510

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Design and applications

Pressure transmitters for industrial applications Type MBS 4510

2/2 and 3/2-way ball valve with pneumatic rotary actuator

2/2 or 3/2-way Miniature Rocker Solenoid Valve

2/2 or 3/2 way ball valve with pneumatic rotary actuator

STEEMCO Flowmeter for Steam

mass flowmeter for compressed air

ORIMAS Mass Flowmeter

STEEMCO-MAS Flowmeter for Steam

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

2/2-way Solenoid Valve with servo diaphragm

Servotronic Digital 615 Series

Magnetic Inductive Flow

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Digital ph transmitter

Diaphragm Valve, Plastic 2/2 way, motorized

Pressure Transmitter JUMO dtrans p30 Type

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Transcription:

Flowmeter for Gases Thermal mass flow measurement Pipe sizes up to 2" Integrated inlet and outlet pipes for flow conditioning -20mA signal output of process value Type can be combined with... Type 8802-YG Process control valve Type 281 Solenoid valve Type 287/Type 8611 Solenoid control valve with plugged PI controller This BigFLOW flowmeter series is made for measuring of especially large flow rates and uses the calorimetric measuring principle. A heated sensor element is cooled down by the gas flow. This cooling effect which depends on the flow velocity and the gas characteristics serve as flow indication, the kind of cooling directly depends on the flow velocity and the kind of gas. This kind of mass flow measurement is independent of pressure and temperature. The flowmeter can be used for monitoring air supplies, but also qualifies for measuring other gases like nitrogen, oxygen, carbon dioxide, natural gas, methane, argon and hydrogen. The display can be rotated by 180. The small console provides units m³/h, m³/min, l/min, l/s, kg/h, kg/min, kg/s or cfm. Further there is a totaliser integrated which counts the gas volume flowing through the pipe. It can be reset by the console. The flowmeter s pressure drop is negligibly low, the measurement works without any moving parts. In combination with a solenoid control valve or an air operated process control valve decentralized flow control loops up to DN0 are possible. Technical Data Full scale ranges (Q nom ) 1) Operating gases Max. operating pressure Calibration gas Up to 82 Nm³/h (air), special flow range on request Air, nitrogen, oxygen, natural gas, methane, hydrogen, argon, carbon dioxide Up to max. 16 bar (up to 0 bar on request) Air, zero point adjustment with operating gas; with hydrogen: calibration with operating gas Gas temperature -30 up to +80 C Ambient temperature -30 up to +80 C Accuracy +/- % o.r. (air), +/- % FS (other gases) Span 1:20 Body material Stainless steel 1.301 (on request 1.0) Electronics housing material Polycarbonate Sealing material NBR, Simrit (for oxygen) 1) at ref. conditions acc. to DIN 133 (0 C and 1013 mbara) Pipe connection R1/2, R3/, R1, R1 ¼, R1 ½, R2 (all connections as external thread) acc. to DIN EN 10226 (ISO 7-1) or flange connections acc. to DIN EN 1092-1 (stainless steel 1.0), other connections on request Electrical connection M12, see page 3 Power supply 2V DC Voltage tolerance ±1% Power consumption Max. 80 ma at 2 V DC Output signal 20 ma (actual value output) Max. load (current output) < 00 Protection class IP6 Dimensions [mm] See drawing on page Pulse output 1 pulse per m 3 (2V DC for 30 ms) Options -Oxygen conformity declaration -Cleaned, free of oil and fat www.buerkert.com p. 1/

Ordering Chart for Air Pipe connection Inner diameter of pipe Flow range Overall length Item no. R ½ 16.1 mm up to 80 Nm 3 /h 2) 300 mm 770 888 R ¾ 21.7 mm up to 1 Nm 3 /h 2) 7 mm 770 889 R 1 27.3 mm up to 26 Nm 3 /h 2) 7 mm 770 890 R 1¼ 36.0 mm up to 0 Nm 3 /h 2) 7 mm 770 91 R 1½ 1.8 mm up to 0 Nm 3 /h 2) 7 mm 770 891 R 2 3.1 mm up to 82 Nm 3 /h 2) 7 mm 770 892 2) Index N: Standard condition, flow rate referred to 0 C and 1.013 bar(a) Calibration for another flow range on request Flow Ranges ½ ¾ 1 1¼ 1½ 2 [m 3 /h] [m 3 /h] [m 3 /h] [m 3 /h] [m 3 /h] [m 3 /h] Ref. to DIN 19/ ISO 1217: 20 C and 1000mbar: Air 90 170 290 80 0 900 Ref. to DIN 133: 0 C and 1013mbar: Air 80 1 26 0 0 82 Argon Ar 10 26 0 70 8 100 Carbon dioxide CO 2 8 16 Nitrogen N 2 80 10 2 2 8 800 Oxygen O 2 8 160 27 20 8 Hydrogen H 2 20 0 70 120 13 22 Natural gas, methane NG 0 100 170 280 32 30 Item no. for a flowmeter calibrated on other gases like air and other flow ranges on request, see specification sheet on page. Ordering Chart for Accessories Article Item no. m cable, with -pin M12 plug at one end, for connector A 770 217 m cable, with -pin M12 plug at one end, for connector B (pulse) 770 796 10m cable, with -pin M12 plug at one end, for connector A 770 79 10m cable, with -pin M12 plug at one end, for connector B (pulse) 770 797 Communication software incl. accessories USB 772 122 Power supply with socket-outlet for appliances, 100-20V AC/ 2V DC 770 799 Power supply in housing for wall mounting, 100-20V AC/ 2V DC 770 798 Without ordering cables, the flowmeter comes with M12-connector for port A. p. 2/

Pin Assignment M12 connector Connector A 1 Conncetor B 2 3 Pin Connector A Connection cable A Connector B Connection cable B (connection port) (pulse port) 1 (SDI) brown * brown 2 VBnegative white * white supply voltage 0V 3 VB+ blue * blue positive supply voltage 12-30V DC I+ P Current signal -20mA - flow value Pulse * grey P Pulse grey * do not connect, just for internal use. Do not connect with an electrical potential and/or ground. M12-connector A M12-connector B -VB grey 3 blue I + - +VB white 2 p. 3/

Dimensions [mm] Threaded pipe connectors 62.0 7. 62.0 7. Welding neck flange (DINxxxx PN0) Welding neck flange (DINxxxx PN0) H H H1 R (ISO 7-1) A A R (ISO 7-1) Ø OD Ø ID L1 L Flange H1 n x øl øk ød L1 L Flange (EN 1092-1 PN0) Diameter Ø OD / ID L L1 H H1 Ø OD (mm) Ø K (mm) n x Ø L (mm) ½" 21.3 x 2.6 / 16.1 300 210 176. 16.7 9 6 x 1 ¾" 26.9 x 2.6 / 21.7 7 27 179.2 16.7 10 7 x 1 1" 33.7 x 3.2 / 27.3 7 27 182.6 16.7 11 8 x 1 1¼" 2. x 3.2 / 36.0 7 27 186.9 16.7 10 100 x 18 1½" 8.3 x 3.2 / 1.9 7 27 189.9 16.7 10 110 x 18 2" 60.3 x 3.6 / 3.1 7 27 19.9 16.7 16 12 x 18 To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 103/2_EU-en_0089237 p. /

Request for Quotation Please complete and send to your nearest Bürkert sales centre* Company Contact person Customer no. Department Note You can fill out the fields directly in the PDF file before printing out the form. Address Postcode/Town Phone/Fax E-mail Quantity required delivery date Operating Data Gas: Air Argon Nitrogen Methane Oxygen Hydrogen Carbon dioxide Natural gas Other gas: Max. flow rate: m 3 /h (Add-on price for special flow range) l/min Reference conditions: N: 0 C, 1013 mbar(a) S:20 C, 1000 mbar(a) Operating pressure: bar(g) Ambient temperature: C F Gas temperature: C F Pipe connection: ½ external ¾ external 1 external Flange: 1 ¼ external 1 ½ external 2 external Other: Optionen: Free of oil and fat, without O2 certificate Free of oil and fat, with O2 certificate High pressure up to 0 bar Comments / Sketch To find your nearest Bürkert facility, click on the orange box www.burkert.com p. /