Note: For use with hydraulic fluids other than those listed above, please consult Yuken representative in advance.

Similar documents
PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS

Hydraulic Fluids. Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance.

10 SERIES MODULAR VALVES

Modular Throttle Valve MST MT MTC MCT Solenoid Operated Throttle Valve Throttle Valve Throttle and Check Valve Counter Restrictors Valve

Series Proportional Electro-Hydraulic Controls

High Pressure, High Flow Rate Modular Valves

A Series Variable Displacement Piston Pumps

PRESSURE REDUCING AND RELIEVING VALVES

PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS

PRESSURE REDUCING AND RELIEVING VALVES

UNLOADING RELIEF VALVES

06 SERIES MODULAR VALVES. Pub. EC-1404

Modular Valves. Ratings

MODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31.

PROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.]

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

FLOW CONTROLS. Maximum Flow U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols. Page. Valve Type.

Proportional Electro-Hydraulic Directional and Flow Control Valves

SHUT-OFF TYPE SOLENOID OPERATED DIRECTIONAL VALVES DSPC/DSPG-01/03(1/8,

DIRECTIONAL CONTROLS

10 SERIES MODULAR VALVES. Pub. EC-1405

Poppet Type Directional Valves

E SERIES. Proportional Electro-Hydraulic Relief Valves. Specification. Model Number Designation. Attachment Mounting Bolts

A Series Variable Displacement Piston Pumps. A16 Type performance characteristics A16 Type Noise level characteristics.

EH SERIES PROPORTIONAL ELECTRO-HYDRAULIC CONTROL VALVES

" " Series Variable Displacement Piston Pumps

High Pressure, High Flow Rate Modular Valves

E SERIES. Proportional Electro-Hydraulic Relief Valves. Specification. Model Number Designation. Attachment Mounting Bolts

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

PROPORTIONAL ELECTRO-HYDRAULIC CONTOROLS

RELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled

Directional Controls

ARL1 Series Piston Pumps. ARL1 Series Piston Pumps. Geometric Displacement. Maximum cm 3 /rev

Series Variable Displacement Piston Pump

PISTON PUMPS. A3H Series High Pressure Variable Displacement Piston Pumps. Features. A3H Series Variable Displacement Piston Pumps.

Proportional Valve.

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Solenoid Pilot Operated Proportional Directional Control Valve

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Type C2 Seat Type Solenoid Pilot Valve

Cartridge Valves Technical Information Directional Valves DCV 03

Proportional Electro-Hydraulic Relieving and Reducing Valves

Proportional Electro-Hydraulic Pilot Relief Valves

Solenoid Pilot Operated Directional Control Valve

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Directional Controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Variable Displacement Piston Pumps

AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps

INSTALLATION AND SERVICE MANUAL SHUT-OFF VALVE

2.3 MEDIUM HEAVY DUTY SERIES

50T,150T,250F SERIES Fixed Displacement-Single, Double, Combination

MONOBLOCK DIRECTIONAL CONTROL VALVES

Proportional Electro-Hydraulic Flow Control (and Check) Valves

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60

AR Series Variable Displacement Piston Pumps. [Comparison of AR16 with A16 ] A16,32 Design 188. AR16,22 Design 130. Ratio of Mass (AR16/A16) 74%

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002

EMulti Purpose Control Valves

HYDRAULICS VINCKE INDUSTRIAL HYDRAULIC VALVES

2.4 HEAVY DUTY SERIES

Discharge rate* 2 L/min MPa (DE10-1) 37.8 MPa (DE10-7)

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012

Direct Operated Type Directional and Flow Control Valves

VANE PUMPS. Output Flow at 1200 r/min at No-Load U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols.

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

50T,150T,250F SERIES Fixed Displacement-Single, Double, Combination 3

Proportional Electro-Hydraulic Flow Control (and Check) Valves

" " Series Variable Displacement Piston Pumps

DIRECTIONAL AND FLOW CONTROL VALVE WITH AMPLIFIER WITH DIGITAL SETTING UNIT (EHD3A SERIES) FEATURES APPLICATION EXAMPLES CAUTION

Pressure Relief Valves

Reducing Valve/Reducing Valve with Check Valve

Proportional Pressure Reducing Valve PDM08130

"AR" SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22-FR01

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Variable Displacement Open Loop Circuit Axial Piston Pumps. V Series

Axial piston pumps type PVPC with ISO mounting flange variable displacement, hydraulic control

Available manual, pneumatic, and hydraulic spool control kits.

Variable Displacement Open Loop Circuit Axial Piston Pumps AR Series

Pilot control unit with end position lock for the remote control of directional valves

03 SERIES. General Information Mounting Surface : ISO 4401-AC-05-4-A, CETOP-5, NFPA-DO2 Up to 25 MPa (3630 PSI), 70 L /min (18.5 U.S.

Q max (see specifications table)

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

D05 Directional Control Valves

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Sectional Directional Control Valve RS 220

BST / BSG-03 / 06 / 10 Threaded Connections / Sub-plate Mounting. Specifications / Model Number Designation. Max. Flow L/min (U.S.GPM) Double Sol.

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators

Directional Controls

SOLENOID VALVES NFPA D03 NFPA D05 D03 & D05 SERIES 35- SOLENOID VALVES. Features. Internal Structure NFPA SIZE: D03 & D05

Hand-operated Hydraulic Control Valve 4- way 2-position 4 Ports

Proportional Valves. Proportional solenoid valves for pressure and flow control

Directional Controls

Modular Unit 6MB HYDRANOR MODULAR UNIT 6MB GENERAL DESCRIPTION. 6MB-200-**-2C General Arrangement. Rev

"AR" SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22- FR01 3

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95

Transcription:

PRESSURE CONTROLS Fluid Types Any type of hydraulic fluids listed in the table below can be used Petroleum base oil Synthetic Fluids Water Containing Fluids Use equivalent to ISO VG32 or VG46. Use phosphate ester type fluid. When phosphate ester fluid is used, prefix F- to the model number because the special seals (fluororubber ) are required to be used. Use water-glycol fluid. Note: For use with hydraulic fluids other than those listed above, please consult Yuken representative in advance. Recommended Fluid Viscosity and Oil Temperature Use under conditions where the viscosity and temperature of the hydraulic fluid remain in the ranges indicated in the following table. Name Viscosity Temperature Remote Control Relief Valve Direct Type Relief Valve Cartridge Type Relief Valves Cartridge Type Remote Relief Valves Direct Type Relief Valves Pilot Operated Relief Valves Solenoid Controlled Relief Valves Pilot Operated Relief Valves H Type Pressure Control Valves HC Type Pressure Controls Valve Pressure Reducing Valve Pressure Reducing and Check Valve Unloading Relief Valves Pressure Switches Hydro-Electric Pressure Switches 15 to 400 cst -15 to +70 0 C * If the valve is provided with a vent restrictor (ex.:a-bsg-03), the viscosity range should be 15-200 cst. Control of Contamination Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise lead to breakdowns and shorten the life of the valve. Please maintain the degree of contamination within NAS 1638 - Grade 12. Use 25 µm or finer line filter. Mounting Bolt Tightening Torques Sl. No. Size Tightening Torque Kgf-cm 1 M5 90.0 2 M6 154.0 3 M8 365.0 4 M10 720.0 5 M12 1235.0 6 M16 3010.0

FLOW CONTROLS Fluid Types Any type of hydraulic fluids listed in the table below can be used Petroleum base oil Synthetic Fluids Water Containing Fluids Use equivalent to ISO VG32 or VG46. Use phosphate ester type fluid. When phosphate ester fluid is used, prefix F- to the model number because the special seals (fluororubber ) are required to be used. Use water-glycol fluid. Note: For use with hydraulic fluids other than those listed above, please consult Yuken representatives in advance. Recommended Fluid Viscosity and Temperature Use hydraulic fluids which satisfy the recommended viscosity and oil temperature given below. Name Viscosity Temperature Flow control valves Flow control and check valves 20 to 200 cst Feed Control Valves Throttle and Check Valves -15 to +70 0 C Deceleration Valves 15 to 400 cst Deceleration and Check Valves Control of Contamination Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise lead to breakdowns and shorten the life of the valve. Please maintain the degree of contamination within NAS 1638- Grade 12. Use 25 µm or finer line filter. Mounting Bolt Tightening Torques Sl. No. Size Tightening Torque Kgf-cm 1 M5 90.0 2 M6 154.0 3 M8 365.0 4 M10 720.0 Flow Control Valves

DIRECTIONAL CONTROLS Solenoid Solenoid connector (DIN connector) The solenoid connector is in accordance with the international standard ISO 4400 (Fluid power systems and components Three pin electrical plug connectors Characteristics and requirements). Plug-in connector Electrical wires are of the plug-in type which allows mounting and removal of the valve without removing connections. Plug-in connector type with solenoid indicator light A solenoid indicator light is added to the above mentioned plug-in connector type. Operation of the solenoid easily identified. AC Solenoid 50-60 Hz common service solenoids do not require rewiring when the applied frequency is changed. DC Solenoid (K-Series Solenoid Operated Directional Valve) These valves differ from conventional DC Solenoid Operated Directional valves and have the following characteristics 1 The spark between the relay contacts has been eliminated and therefore the valve can be operated by miniature relays. 2 The surge voltage is approximately 10% of that normally experienced. 3 Time lag on de-energisation is reduced by approximately 50%. R Type Models with Current Rectifier and DC Solenoid Specially designed DC solenoid and receptacle (or connector) containing AC-DC rectifier and transient peak suppressor are provided. Connection to be made to AC Power source as with conventional AC solenoid. Remarkably high reliability and long life and other advantages including quite valve operation, no overheating of coil due to the spool sticking and protection against transient voltage peaks are assured. RQ Type Models with Current rectifier and quick Return Solenoid Valve characteristics are identical to all type except for the fast return time of the spool after de-energisation. Insulation class of Solenoid: Class-H Solenoid Operated/Solenoid Controlled Pilot Operated Directional Valve

Directional Valves DIRECTIONAL CONTROLS These valves are used for shifting oil flow direction of hydraulic circuit and for a control of actuator starting/stopping as well as the operating direction shifting of actuator. Directional valves are classified in the following five types depending on the operational method. Solenoid Operated Directional Valves, Solenoid Controlled Pilot operated Directional Valves, Pilot Operated Directional Valves, Manually Operated Directional Valves and Mechanically Operated Directional Valves. Spool Types Spool types are classified to the condition of flow at the neutral position. Spool Type 2 (Closed Centre All Ports) 3 (Open Centre All Ports) 4 (Open Centre A, B&T) 40 (Open Centre A, B&T Restricted Flow) 5 (Open Centre P, A&T) 6 (Open Centre P&T Closed Crossover) 60 (Open Centre P&T Open Crossover) 7 (Open Centre All Ports Restricted Flow) 8 (2-Way) 9 (Open Centre P, A&B) 10 (Open Centre B&T) 11 (Open Centre P&A) 12 (Open Centre A&T) Graphic Symbols Schematic Drawing (Centre Position) Functions and Application Hold pumps pressure and cylinder position at neutral. Care should be paid if used cylinder as a 2-position type because shock occurs when each port is blocked in Transit. Pump can be unloaded and actuator is floating at neutral. If a 2-position type is used, shock reduced as each port is released to tank in transit. Pump pressure is held and actuator is floated at neutral. 2-position type is used when system pressure is required to be held in transit. Shock during transit is less compared to spool type "2" In a variation of spool type "4", a restrictor is provided in A-T and B-T ports, making it faster at stopping the actuator. It can be used when a pump is loading at neutral and actuator is halted at one way flow. Pump is unloading and actuator position held at neutral. Suitable for series operation. It is a variation of spoool type "6". Shock is reduced as each port is released to tank on transit. Mainly used as a 2-position type. Shock is reduced on transit. Pump pressure and cylinder position is held at neutral in the same way as spool type "2". It is used as 2 way type. Regenerative circuit is provided at neutral. Prevent actuator from one direction drift by leakage of P port at neutral. Half actuator movement positively at B, T ports blocked P, A ports connected at neutral. Prevent actuator from one direction drift by leakage of P port at neutral. Directional Valves

DIRECTIONAL CONTROLS Mounting Surface Mounting surface dimensions conform to ISO 4401, Hydraulic fluid power-four-port directional control valves-mounting Surfaces. Name Model Numbers ISO Code of Mounting Surface Solenoid Operated Directional Valves Solenoid Controlled Pilot Operated Directional Valves -DSG-01 -DSG-03 -DSHG-06 -DSHG-10 ISO-4401-AB-03-4-A ISO-4401-AC-05-4-A ISO-4401-AE-08-4-A ISO-4401-AF-10-4-A Instructions Mounting (S-) DSG-01 (S-) DSG-03 (S-) DSHG- No spring detented models not energized continuously must be installed so that the spool axis L-L is horizontal. Otherwise there is no mounting restrictions. Energisation 1 No-Spring Type One of two solenoid should be energised continuously to avoid malfunction. 2 On double solenoid valves do not energise both at the same time as it will result in coils burning out. Valve Tank Port Avoid connecting the valve tank port to a line with possible surge pressure. Piping end of tank line should be submerged in oil. Pilot Drain Port for Solenoid Controlled Pilot Operated Valve Avoid connecting the valve pilot drain port to a line with possible surge pressure. Piping end of drain should be submerged in oil. Shockless Type In order to benefit from a shockless operation, it is necessary to fill the tank with operating oil. Only after the tank line has been filled with operating oil the valve should be used on a regular basis. Operating Force by Manual Actuator Take care as the operating force by the manual actuator increases in proportion to the tank line back pressure. (See the graph below.) Kgf 15 Operating Force 10 5 0 0 10 20 30 40 Tank Line Back Pressure Kgf/cm² Solenoid Operated/Solenoid Controlled Pilot Operated Directional Valve

DIRECTIONAL CONTROLS Type of Fluids Any type of hydraulic fluids listed in the table below can be used. Petroleum base oil Synthetic Fluids Water Containing Fluids Use equivalent to ISO VG32 or VG46. Use phosphate ester type fluid. When phosphate ester fluid is to be used, prefix F- to the model number because a special seal (fluororubber) will be used. Use water-glycol fluids or w/o emulsion type fluids. Note: 1 Not applicable with G-DSG series valves. 2 Water -glycol fluids cannot be used for CDSG-03 types. 3 For use with hydraulic fluids other than those listed above, please consult Yuken representatives in advance. Recommended Fluid Viscosity and Oil Temperature Use hydraulic fluids which satisfy the recommended viscosity and oil temperature given in the table below. Name Viscosity Temperature Solenoid Operated Directional Valves Solenoid Controlled Pilot Operated Directional Valves Pilot Operated Directional Valves Manually Operated Directional Valves Cam Operated Directional Valves In-Line Check Valves Right Angle Check Valves Pilot Controlled Check Valve Solenoid Operated Poppet Type Two-Way Valve Poppet Type Directional Valves Double Locking Check Valve 20 200 cst -15 to +70 o C G series Shockless Type Solenoid Operated Directional Valves (Shifting Time Adjustable) 15 200 cst -15 to +60 o C Control of Contamination Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise lead to breakdowns and shorten the life of the valve. Please maintain the degree of contamination within NAS 1638-Grade 12. Use 25 µm or finer line filter. Mounting Bolt Tightening Torques Sl. No. Size Tightening Torque Kgf-cm 1 M5 90.0 2 M6 154.0 3 M10 720.0 4 M12 1235.0 5 M16 3010.0 6 M20 5860.0 Directional Valves

E SERIES Care in Application Control Valve Installation Requirements Mounting Be sure that faces up. In addition, if the valve is positioned vertically, the minimum adjustment pressure is 2 Kgf/cm 2 or higher. [Bad Example] O M Do not Insert the Shut -off Valve in the Drain line If the drain line is closed with the shut-off valve, then the solenoid inner pressure rise unduly to incur machine malfunction or breakage. Do not insert a shutoff Valve Ensure that the drain piping is separated from the other drains and positioned below the reservoir oil level The drain piping must be such that no air intake occurs. Furthermore to minimize the effect of back pressure, the drain line is not connected to the other drains. Drain piping Operating Precautions Electrical Do not insert or take out PC boards from the inside with the power amplifier turned on. Do not connect or disconnect the control valve solenoid connector with the power amplifier turned on. Oil Reservoir Control Valve Before test run or adjustment, be sure to bleed the control valve of air. Conduct air bleeding periodically. Before using the power amplifier for test run or adjustment purposes, be sure to manually operate the control valve with its manual adjustment screw to check that the hydraulic circuit is normal. E Series Proportional Electro-Hydraulic Control Valve

E SERIES Air Bleeding To ensure stable control, conduct air bleeding thoroughly and fill the solenoid cover with oil. Air bleeding can be done by slowly loosening one of the air vents at the end of the solenoid. Choose one of the three air vents which is expected to work most effectively. Manual Adjusting Screw When initial adjustments are to be made or when no current is supplied to the valve due to electric failure or other problem, turn the manual adjusting screw to temporarily set the valve pressure/flow rate. Under normal conditions, however, this screw must be kept in its original position (see the figure below). 3 Places Solenoid Solenoid Case Manual Pressure Adj. Screw M4 Screw Manual Flow Adj. Pin Tank and Drain Piping The tank-line back pressure and drain back pressure directly affect the minimum adjustment pressure. Therefore, do not connect the tank or drain pipes to other lines, but connect them directly to the reservoir maintaining the back pressure as low as possible. Be sure that the tank and drain pipes ends as immersed in fluid. Hysteresis and Repeatability Value Indication The hysteresis and repeatability values indicated in the specifications for each control valve are determined under following conditions: Hysteresis Value: Obtained when Yuken s applicable power amplifier is used. Repeatability Value: Obtained when Yuken s applicable power amplifier is used under the same conditions. E Series Proportional Electro-Hydraulic Control Valve

E SERIES Hydraulic Fluids 1. Fluid Types Any type of hydraulic fluid, listed in the table below can be used. Petroleum based oil Synthetic fluids Water containing fluids Use fluids equivalent to ISO VG32 or VG46 Use phosphate ester or polyol ester fluid. When phosphate ester is to be used, Prefix - F - to the model number because a special seal (Flurorubber) will be used. Use water glycol fluid. 2. Recommended Fluid Viscosity and Temperature Use under conditions where the viscosity and temperature of the hydraulic fluid remain in the ranges indicated in the following table. Remote Control Relief Valves Direct Type Relief Valves Pilot operated Relief Valves Name Viscosity Temperature Solenoid Controlled Relief Valves HC Type Pressure Control Valves Pressure Reducing and Check Valve Unloading Relief Valve Pressure Switches 3. Control of Contamination 15-400 cst -15+70 0 C Due caution must be paid to maintain control over contamination of the hydraulic fluids which may otherwise, lead to breakdown and shorten the life of the valve. Please maintain the degree of contamination within NAS 1638-Grade 11. Use 20 µm or finer filter. Mounting Bolt Tightening Torques Sl. No. Size Tightening Torque Kgf-cm 1 M5 90.0 2 M8 365.0 3 M10 720.0 4 M12 1235.0 5 M16 3010.0 E Series Proportional Electro-Hydraulic Control Valve