LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

Similar documents
MINISTICK TM UV Germicidal Ultraviolet Light

21", 33", 45", & 61" Installation & Operation Manual

BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

Installer s Manual. PCO/UV N-Duct Model

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

HARDWARE KIT INSTALLATION GLOVES

Safety, Installation and Service Manual Models 1952, 1953 & 1972

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

Installation & Maintenance of the Fresh-Aire UV Tubular Rack System for Commercial Air Handler Systems

INSTALLATION INSTRUCTIONS

UV-AIRE AIR PURIFYING SYSTEM

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

Air Curtain. Installation, Operating and Maintenance Instructions

CAUTION: Read manual carefully for proper procedures and operation.

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

Automatic Emergency Light

PUSH BUTTON KEY CABINET

EXPERIENCE THE NEW IAQ REFRESH YOUR AIR

COILCARE PM. Installation Instructions and Operating Manual. CoilCare Series BioZone Scientific International, Inc.

UV-AIRE AIR PURIFYING SYSTEM

Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System For PTAC & ETAC Units

DISC BRAKE CALIPER TOOL SET

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

WARNING Risk of property damage, injury, or death.

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

User Guide IGD Series

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

6 OFF ROAD LIGHT BAR

For Mini Split Units. Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

This document describes:

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Model 8144NC Fresh Air Ventilator

For technical questions and replacement parts, please call

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

Swing Arm Magnifying Lamp

Owner s Manual & Safety Instructions

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

Extension Hopper Installation & Operator s Instruction Manual for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

MCI. SynAIRgPURE. Owner s Manual

Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

Kitchen Tech Series Air Curtain

CTFRP Series Power Supplies

SUBMERSIBLE MINI-PUMP

BroadBand PowerShield. 20 AHr Battery. User Manual

Installation & Operators Manual

25 GALLON PORTABLE OIL LIFT

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference

Installation Power Management Unit Battery Cables and Battery Harness

Dispenser & Warmer RIC-1909 RIC-1909EXP

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

MaxLite LED Linear HighBay Fixtures

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

JD-2 TOLL FREE UG August /2011

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

ROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008

Model FM2642 Wall Mount. Full Motion Television Wall Mount

SYSTEM CONTROL KIT. Model: CK-41F. Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances.

CAMBELT TENSION GAUGE

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

SIDE-WIND, A-FRAME TRAILER JACK. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

II DISTRIBUTION & SUBSTATION TYPE C

gamma uv Aquarium Ultraviolet Sterilizers

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

FOLD N STORE. Table Tennis Table. Assembly Instructions Model DS, DS CONTACT INFO Hours.

LED LARGE WALL PACK (CUTOFF & STANDARD)

This document describes:

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

INSTALLATION INSTRUCTION & OWNER S MANUAL

Pump Installation and Service Manual HRS Hydromatic Retractable System

SUNTURA SOLAR TRACKER

DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L

Read this entire manual before operation begins.

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

INSTALLATION & OWNER'S MANUAL

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter

BEFORE YOU BEGIN LIST OF COMPONENTS. Isopropyl SWITCH SCOTCH-BRITE PAD ALCOHOL PREP PAD SWITCH HARNESS REVOLVER PCM COVER STICKER

Tiller Lock Assembly

Extension Boot System

Page Number. Contents: Product Features 2. Physical Data 2. Nomenclature. 3. Blower Performance 3. Electrical Data 4. Warranty.. 6

AQUA2000 From O3PURE

SPC-PANEL Simplex, Single Phase Pump Control Panel

Further information: Berriman Associates Model 850P.2 Owners Manual

IMPORTANT SAFETY INFORMATION

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

TD77-2 and ULB42-TD-2 TRAFFIC DIRECTOR CONTROL BOXES

INSTALL GUIDE Dodge/RAM 5.7L HEMI

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

SUNTURA HD SOLAR TRACKER

Transcription:

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light Installation & Operation Manual This manual covers the following models: LightStick #19300 LightStick Plus #19301 GENERAL This product emits germicidal ultraviolet (UV-C) light to help disinfect the cooling coil, drain pan, and internal surfaces of HVAC systems for improved indoor air quality. BEFORE INSTALLING Read all instructions carefully. Failure to do so could damage the equipment or cause harm to yourself or others. Acknowledge all warnings. Only qualified technicians should perform the installation. INCLUDED INSIDE BOX Power Module Germicidal UV lamp Power cord Remote lamp cord Mounting bracket (LightStick Only) Magnetic Mounting bracket (LightStick Plus Only) Filter shield (LightStick Plus Only) Self-drilling screws UV safety viewport UV safety label Installation & operation manual Installation hardware

SPECIFICATIONS 3.35 5.3 1.75 3.16 4.75 LIGHTSTICK Dimensions: Power Module: 4.75 L x 3.16 W x 1.75 H Bracket: 3.5 L x 2.25 W x 3.5 H Electrical: 24V (Expanded range ballast: 20V-32V), 50/60Hz, 1.4A. 3000V surge protection. 3-ft power cord. 4-ft lamp cord Lamp Length: 15 Weight: 2lb Humidity: Water resistant lamp. Lamp Life: 9000-hour. Warranty: 5-year on power module. 1-year on lamp. LIGHTSTICK PLUS Dimensions: Power Module: 4.75 L x 3.16 W x 1.75 H Bracket: 3.5 L x 2.25 W x 3.5 H Electrical: 24V (Expanded range ballast: 20V-32V), 50/60Hz, 1.4A. 3000V surge protection. 3-ft power cord. 4-ft lamp cord Lamp Length: 15 Weight: 2lb Humidity: Water resistant lamp. Lamp Life: 18,000-hour. Warranty: 7-year on power module. 2-year on lamp. U.S. Patent Nos. 5,334,347, 5,817,276, 6,245,293, 6,267,924, 6,280,686, 6,313,470, 6,627,000, 6,539,727, 6,932,494, 6,550,257.

UV INSTALLATION NOTES This device is meant only to be installed in the duct portion of the HVAC system. If the UV device is installed on the inlet side (return air side) of a coil, make sure that the HVAC system is configured such that the blower is located between the return air filter and the in-let of the coil, such as would be found in a traditional up-flow, or horizontal furnace with the coil placed after the heat exchanger. If the UV device is installed near an air filter, check with filter manufacturer for UV-C resistance properties. Optional lamp shield accessory is available to protect air filter. Ask your local wholesaler. If the desired UV installation location is intended to irradiate an air filter, to neutralize the microbiological matter on the air filter surface, such as would be found in the return air drop of a basement application or in the return plenum of a horizontal system in an attic; take precautions as described in note above, and make sure the UV fixture is placed on the return side of the filter. DO NOT INSTALL THE UV FIXTURE ON EITHER SIDE OF THE FILTER IN HALL / CLOSET RETURN AIR APPLICATIONS. Fig. 1 HVAC system. UV Light Hazard. Can cause serious eye and skin damage. Do not look at UV-C light. Wear UV-C eye and skin protection.

W-COIL / ABOVE A-COIL INSTALLATION (Remote Lamp) Disconnect power to the air handler and open access panels. Magnetic Bracket Installation - Slit insulation on the back or side wall of air handler and attach magnetic bracket to the wall. Standard Bracket Installation - Install the lamp bracket at the desired location with two self-drilling screws (included). Secure the lamp to the lamp bracket with the provided knurled nuts. Connect remote mount lamp power cord. Fig. 2 Attach lamp to lamp bracked and install in desired location. A-COIL DELTA PLATE INSTALLATION (Remote Lamp) Drill a 7/8 hole into the delta plate and place gasket (included) around hole. Insert lamp directly into hole and secure the lamp to the delta plate with two self-drilling screws. (Screws and rubber washers Included.) Connect remote mount lamp power cord. Note: A-Coil delta plate installation does not use lamp bracket. Fig. 3. Insert lamp into delta plate hole and secure with screws and washers. Connect remote lamp power cord. NOTICE Clean lamp prior to installation. Use a cotton cloth to remove dirt and fingerprints. Failure to clean the lamp could shorten the lamp s lifespan. UV Light Hazard. Can cause serious eye and skin damage. Do not look at UV-C light. Wear UV-C eye and skin protection

A-COIL DELTA PLATE INSTALLATION (Direct Connect ) Drill a 7/8 hole in the outer sheet metal where the lamp will be centered on the return side of the coil. See diagram. Place gasket (included) around hole. Insert lamp into power module and secure with self-drilling screws. (Included.) Insert lamp/power module assembly directly into hole and secure with selfdrilling screws (Included.) Note: A-Coil delta plate installation does not use lamp bracket. Fig. 4 Insert lamp into power module and secure with screws. Fig. 4A Insert assembly into delta plate hole and secure with screws. NOTICE Clean lamp prior to installation. Use a cotton cloth to remove dirt and fingerprints. Failure to clean the lamp could shorten the lamp s lifespan. UV Light Hazard. Can cause serious eye and skin damage. Do not look at UV-C light. Wear UV-C eye and skin protection

INSTALL POWER MODULE (Remote Lamp) With the lamp cordage facing away from the mounting surface, use the long mounting screws and install the power module in a suitable location inside the control panel of the air handler using two self-drilling screws (included). NOTE: DO NOT OVERTIGHTEN SCREWS. Connect the power module to constant 24V power. Connect input 24V power cord. Align markers on power module with power cord connector. Fig. 5A Flip power module over and secure with long screws. Do not overtighten. INSTALL POWER MODULE (Direct Connect ) With the lamp directly connected to the power module, connect the power module to the mounting surface using the short, self drilling screws (included). Connect the power module to constant 24V power. Connect input 24V power cord. Align markers on power module with power cord connector. The device must be installed in compliance with all national and local electrical and mechanical codes. Failure to do so will void warranty. Electric Shock Hazard. Can cause injury or death. Disconnect all electrical power supplies before servicing. For Use with 24V Only.. Do not exceed voltage rating. Severe damage to device and/or fire could result. Verify proper voltage.

24V INSTALLATION NOTES Installing the 24V UV fixture may require an upgrade to the 24V transformer in the furnace, or air handler, depending upon the capacity of the OE specified by the manufacturer of the AHU / furnace. 1. Verify the available volt amps prior to connecting the UV fixture to the 24V circuit. Energize all 24V components so they reach their maximum amp load (Straight cool system - activate cooling. Heat pump - activate heating mode.) 2. After obtaining the available volt amps, determine if the existing transformer can accommodate a 1.4 amp load: 3. After installing the UV fixture, energize all 24V components at their full amp draw, including the UV fixture, and ensure that all systems are operational and that fuses remain intact. 4. RECOMMEND CONNECTING TO A DEDICATED 40VA CLASS 2 TRANSFORMER IF EXISTING TRANSFORMER CANNOT ACCOMMODATE AMP LOAD RECOMMENDED ABOVE. CONNECT LAMP Connect lamp connector to power module connector. Connectors are keyed for proper alignment. Be sure to fully seat the connectors for proper electrical connection and water resistance. NOTICE Fully Seat Lamp Connector. Failure to properly seat lamp connector could result in improper lamp operation and/or compromise water resistance.

INSTALL UV SAFETY VIEWPORT Adhere the provided UV safety label to the outside of the duct near the installation location and drill a 5/8 hole as indicated on the label. Press the UV safety viewport into hole. Close all access panels and reconnect power to the air handler. Verify that a blue glow can be seen through the UV safety viewport. NOTICE Replace Lamp Per Recommended Maintenace Schedule. UV-C lamps expend their germicidal effectiveness over time. Replace the lamp even if the lamp appears to be operating normally.

WARRANTY Dust Free LP. warrants this Bio-Fighter UV-C Light to be free from defects in materials and workmanship under normal use and service, for a period of five (5) years or seven (7) years from the date of purchase. This warranty does not cover UV-C lamp(s), which carry a one (1) year warranty or (2) year warranty from the date of installation. This warranty does not cover cosmetic damage, damage due to acts of God, damage as a result of handling or shipment, negligence, misuse, connection to improper voltage, improper maintenance, or abuse. This warranty is void if defect(s) result from failure to have this unit installed by a qualified, properly licensed, heating and air conditioning contractor in compliance with all local building and construction codes. Dust Free LP s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any covered component of the Bio-Fighter UV-C Light which is found to be defective within the parameters defined herein. Dust Free LP reserves the right to replace or repair the defective part or component. DUST FREE LP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. (Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.) THE WARRANTIES SET FORTH HEREIN ARE EXCLUSIVE AND DUST FREE LP EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES, WHETHER WRITTEN OR ORAL, IMPLIED OR STATUTORY, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY, WORKMANSHIP, OR FITNESS FOR A PARTICULAR USE. If the limited warranty is void due to failure to use a qualified contractor all disclaimers of implied warranties shall be effective upon installation. How to make a warranty claim or have questions answered: Should you have a warranty claim or questions about the warranty policy, contact the distributor or dealer from which you purchased the product. Proof of original purchase and proof of identity that the original purchasing party is filing the claim is required in order to initiate a warranty claim. Defective parts must be returned no later than thirty (30) days after the failure to the installing contractor together with the model number, serial number, and date of installation. All service and removal must be performed by a licensed HVAC contractor. You must pay shipping charges and all other costs of warranty service. Warranty is only valid the United States and Canada. THIS WARRANTY SHALL NOT OBLIGATE THE MANUFACTURER FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY THE INSTALLING CONTRACTOR AS CONTRASTED TO DEFECTS IN THE GERMICIDAL LIGHT ITSELF. NOTE: Do not return any products or parts to the factory without a factory issued Return Authorization number issued by the Dust Free LP customer service department. In the event you have any questions concerning the use and care of this product or this warranty which have not been answered to your satisfaction by the distributor or dealer, please call or write the factory. Dust Free PO Box 519, 1112 Industrial Park Drive Royse City, TX 75189 1-972-635-9564 www.dustfree.com