VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

Similar documents
VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

INSTALLATION INSTRUCTIONS

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

Use and Care Guide.

INSTALLATION INSTRUCTIONS

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

BroadBand PowerShield. 20 AHr Battery. User Manual

Wireless Key Tracker. Locate Lost Keys instantly

SAVE THESE INSTRUCTIONS

LED Recessed Troffer Retrofit Kit

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

Installation and Operating Manual

ROPE LIGHT ITEM # MODEL #UCL48L. Français p. 8. Español p. 15 ATTACH YOUR RECEIPT HERE. Purchase Date

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

WIRELESS SMART CHARGING PAD OPERATING INSTRUCTIONS PLEASE READ BEFORE OPERATING THIS EQUIPMENT

FLO Home TM G5 Model. Installation guide

Cruising Charger Series OWNER S MANUAL

RJH-4/6046. Wireless 3.5 Channel Mega Helicopter. (Instruction Manual)

CLASSIC II Portable Braking System

Select II Portable Braking System

MQ4C-24/6485 WIRELESS INDOOR/OUTDOOR QUAD-COPTER

Please read and understand all precautions prior to use.

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

LED FLUSHMOUNT CEILING FIXTURES

Innovative Circuit Technology Ltd.

Model WS-6020U Solar Station QUICK SETUP GUIDE

WF-5110R True Sine Wave Inverter

Instruction Manual. SmarTire LF Initiator Tool. PN: Revision 1.2. Copyright 2006 SmarTire Systems Inc.

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

Operator Manual For use with WFCO ULTRA III Power Center WF-9900 Series (model number located on the door assembly label)

/09 Rev 1. Lionel Little Lines The Polar Express Set Owner s Manual

User Guide. Model No.: GDI-GFD7200

BATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL

AeraMax Pro AM IV. Please read these instructions before use. Do not discard: keep for future reference.

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

Intelligent Charging System Series

OWNER S MANUAL Please read and understand all precautions prior to use.

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

Owner's Manual. For latest instructions please go to

User Guide. Digital Shipping Scale S150

TC26-B Vehicle Sensor

Operator s Manual UNIVERSAL MULTI-UNIT CHARGER STANDARD & RAPID WARNING. ericssonz

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

Operator Manual For use with WFCO ULTRA III Distribution Center WF-8900 Series (model number located on the door assembly label)

CAUTION: Read manual carefully for proper procedures and operation.

6. Electrical. 7. Settings. 8. Quick

Cable/Gate Lock INSTALLATION MANUAL

USE AND CARE GUIDE 7000 LUMEN TWIN HEAD LED WORKLIGHT WITH TRIPOD

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

02/15/01. Powerware User s Guide VA.

T500 Series. Applications. Features. Applicable Literature. Non-Digital, On/Off Thermostat General Instructions

V-D2425 and V-D2440 Digital Clock

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Operator s Manual UNIVERSAL DESK CHARGER STANDARD & RAPID WARNING. ericssonz

4 WAY WIRELESS REMOTE CONTROL SYSTEM. User Manual

Use and Care Guide. Part # SC SV-OS-BZ SC SV-OS-W Model #

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Owner's Manual. For latest instructions please go to

P OWER CUBE PLEASE READ BEFORE OPERATING THIS EQUIPMENT. Powerful Universal Portable Charger T M

Owner s Manual. OutCast 1.2. The Ultimate Outdoor Speaker System

Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

Trigger. Battery Cap. Radar Icon. Power Button

USER GUIDE. c--' c-' Remote. for #SED-10R

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

LIPSTICK CHARGER POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS

AM-134, AM-140, AM-234, AM-240, AM-334, AM-340, AM-368

DC REGULATED POWER SUPPLY

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

ADI-125/750 ADI-125/1500 ADI-125/2500

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Bounce & Spin ZebraTM

HERCULES ITEM NO UNBREAKABLE HELICOPTER AGES CHANNEL GYRO RC HELICOPTER FEATURES

WF-5100 Series True Sine Wave Inverters

Owner's Manual. For latest instructions please go to

/09 REV. Lionel Pennsylvania Flyer G Gauge Owner's Manual. Adult assembly required

WF-5110R True Sine Wave Inverter

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

User s Manual Lineage LI3000 UPS K

2800 OPERATING INSTRUCTIONS

Owners Manual for TPMS plus GPS

User s Manual Legend SB825 UPS K

WARNINGS, CAUTIONS AND NOTES

BatteryChargers. Quick Start Guide AA RECHARGER POWERCHARGER

OPERATING INSTRUCTIONS

SolarWrap. Quick Start Guide. Model # PP1040/PP1025

Cab Control Operators Manual

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

Installer Guide smart connect

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

MIL-24/2600Q MIL-24/3200DQ

USE AND CARE GUIDE 2500 LUMEN LED PORTABLE WORKLIGHT

Owner's Manual. mycharge name and logo are registered trademarks of RFA Brands RFA Brands. All Rights Reserved. Patent Pending.

DC to AC Power Inverters

DC to AC Power Inverters

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES

OWNERS MANUAL JANUARY 2007 ISO

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Transcription:

Issue 6 VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY INTRODUCTION These instructions provide the specifications, installation and maintenance information for the VP-6124 and VP-6124-E, 24Volt Power Supplies. SPECIFICATIONS The VP-6124 and VP-6124-E are fully regulated 24VDC, 6 Amp switching power supplies. The primary is protected by a 4 Amp slo-blow fuse and the 2 Amp outputs by auto resetting fuses. The outputs are floating with respect to ground. The regulator will maintain 24 Volts +/-2% over the rated range of input voltages and output loads. A greater than 6 Amp load on power up will cause the power supply to current limit. Short circuit protection is provided. Over voltage is provided to limit the output voltage to approximately 28 Volts should a failure occur within the power supply. Outputs may be paralleled but not series connected. Applications The VP-6124/VP-6124-E are designed to be used with: All Valcom page control units Valcom one-way amplified speaker assemblies Any application where 24VDC filtered talk battery is required Design Features VP-6124: 115VAC, 60Hz input VP-6124-E: 230VAC, 50Hz input (preset at the factory for the specific unit) Hold Up Time: 350ms Power Line Ride Through (3) LPS outputs (24VDC at 2 Amps each) Short Circuit Protection UL listed for USA and Canada: CE mark FCC Class B LED operational indicator Remote battery charge test EMI filtering Auto recovery overload protection AC Standby and UPS indication Optional UPS remote battery control for providing uninterrupted power (VP-6124-UPS) available 3 second power-up delay to drive large capacitive loads up to 40KµF Nominal Specifications General Weight: Dimensions: Input - VP-6124 Frequency: Full Load Line Current: Input - VP-6124-E Frequency: Full Load Line Current: 5.0 lbs. (2.27 Kg) 10.30"H x 5.92"W x 2.50"D (26.16cm H x 15.04cm W x 6.35cm D) 115VAC 60Hz 3 Amps 180 Watts 230VAC 50Hz 1.5 Amps 180 Watts 1 947273

Output 144 Watts 24 Volts Current: 6 Amps (3-2 Amp outputs) Fusing: 3-2 Amps, auto-reset polyswitch fuses Ripple and Noise: 1% P-P maximum Environmental Operating Temperature: Storage Temperature: Cooling: Humidity: Shock: Precautionary Notes: 0 to +40 o C -40 o to +85 o C Free Air Convection 10 to 90% (non-condensing) 10G CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. FCC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. INSTALLATION The VP-6124 and VP-6124-E are designed for wall mounting only. The unit should be mounted within seven feet of an AC receptacle. Screw mounting plate to wall and position power supply on mounting plate via the mounting slots. See page 4 for mounting instructions. Connections Connections to Valcom page control units are shown in Figure 1. When using the VP-6124 or VP-6124-E with Valcom page equipment, a strap may be added from the local ground terminal to either of the "+" outputs. When installing Valcom one-way amplified horns, connect the white and black wires of the horn to the power supply "-" and "+" terminals respectively. When installing Valcom one-way speakers, connect the "-24VDC" and "GND" terminals of the speaker to the "-" and "+" terminals respectively. Plug power supply into wall outlet. Power supply activates after a 3 seconds delay. Use CAT-5 wire. NOTE: Each 24VDC screw terminal is fused by a 2 Amp polyswitch automatic type fuse. Therefore, when connecting equipment to this power supply, the load should be distributed between the (3) 2 Amp output terminals and each load should not exceed 2 Amps. 2

TECHNICAL ASSISTANCE When trouble is reported, verify the unit is properly connected and there are no broken connections leading to this unit. Assistance in troubleshooting is available from the factory. When calling, you should have a VOM and a test set and calling from the job site. Call (540) 563-2000 for Technical Support or call (540) 767-1555 for Valcom 24-hour Faxback System or visit our website at http://www.valcom.com. Valcom equipment is not field repairable. Valcom, Inc. maintains service facilities in Roanoke, VA. Should repairs be necessary, attach a tag to the unit clearly stating company name, address, phone number, contact person and the nature of the problem. Send the unit to: Valcom, Inc. Repair and Return Dept. 5614 Hollins Road Roanoke, VA 24019-5056 VALCOM LIMITED WARRANTY Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service for a period of one year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or refund of any such defective device within the warranty period, provided that: 1. inspection by Valcom, Inc. indicates the validity of the claim; 2. the defect is not the result of damage, misuse or negligence after the original shipment; 3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus parts and labor will be applied to units defaced or physically damaged); 4. freight charges for the return of products to Valcom are prepaid; 5. all units out of warranty are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to additional charges for parts and labor). This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation or use of the product. This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point. Headquarters: In Canada Valcom, Inc. CMX Corporation 5614 Hollins Road 35 Van Kirk Drive #11 and 12 Roanoke, VA 24019-5056 Brampton, Ontario L7A 1A5 Phone: (540) 563-2000 Phone: (905) 456-1072 FAX: (540) 362-9800 FAX: (905) 456-2269 TROUBLESHOOTING CHART 1. No output. PROBLEMS 2. LED pulses in reset mode. SOLUTIONS a. Verify AC present at receptacle. b. Remove DC load and check for 24VDC using a VOM. a. Locate and correct short circuit in output wiring. b. Verify total equipment power consumption does not exceed 6 Amps. 3

Typical Page Control Unit A Ground A Battery B Ground B Battery Figure 1 Local GND Strap To other page units or amplified speaker assemblies - + - + - + 24V Outputs VP-6124/ VP-6124-E Power Supply Use Steps 1 through 3 and Figures 2 and 3 to mount the power supply on a wall or other surface capable of supporting the weight of the supply (approximately 5 pounds). Carefully unpack the power supply and inspect for shipping damage. Select a location for installation of the power supply in a clean, dry, vibration-free area with moderate temperature within six feet of an approved AC outlet. 1. Using the mounting bracket (see Figure 2) as a template, mark the two slotted holes on the surface of the wall. 2. Using mounting hardware capable of supporting approximately 5 pounds, mount the bracket to the wall ensuring that the mounting holes are oriented as shown in Figure 2. Top Slotted Holes Bottom Figure 2. Bracket 4

3. Using Figure 3 as a guide, mount the power supply onto the mounting bracket. Power Supply Bracket Figure 3. the Power Supply 5