EX T... AT. Sensors with switching function. Identification II 2 G Ex db eb mb IIC PTZ 16 ATEX 0024

Similar documents
Temperature controller- and limiters

EX GHL ALAT Connection fitting

Ex m Solenoid Operator Type 0519

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Operating Instructions

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Technical Data. Dimensions

Solenoid coils VACF Type codes

Solenoid Operator 0516 / 1216

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

Instruction Manual. Ex-Time 40 / 50

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

Instruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH.

Sensor boxes SRBE Key features and product range overview

Solenoid Operator 0513 / 1213

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

Declaration of Conformity as per Directive 97/23/EC

Assembly. Trunk IN + - S U, I U, I. Spur 1

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Pan and Tilt Head CDD2416-T

ILED Dorado. User Manual

Operating Instructions

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Operating Instructions

SynergEX Panelboards. Installation & Maintenance Information IF Panelboards for Hazardous Locations SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

RVP-R- VAV controller. In explosion-proof version

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

ATEX HAZARDOUS-AREA RATED CONTAINER HEATERS AND CONTROLLER PRODUCT LAUNCH BOOK

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Solenoid Valves Type 3963

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Solenoid drive. Operating instructions

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

Floodlight Range Installation Guide

Zone 1 Linear Range - Installation Guide

Solenoid coil for control in potentially explosive areas Type BZ

Magnetic-inductive flow meter for hazardous areas

Operating Instructions

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

LED Driver Linear / area dimming

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Measuring insert for process resistance thermometer

Sentronic PLUS 614 Series

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

LED Driver Linear / area fixed output

Technical Data Sheet

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

IQL Helios Area-/Streetlight. User Manual

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Leading the way in hazardous areas Features EATON

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

SERVO MOTORS BRUSHLESS SERVO MOTORS ATEX ZONE 2-22 OPERATING INSTRUCTIONS 2016

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

GEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds

INSTRUCTION MANUAL (ATEX / IECEx)

LED Driver Compact fixed output

LED Driver Compact fixed output

ExBin-P Pressure switches 5 Pa Pa

Level Measuring Sensor for Diesel Fuel Tanks

Explosion-protected surface-mounting Thermostat ATH-Ex Series

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

ILED Aquarius Illuminated Windsock. User Manual

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Usage Instructions of Solar Control for 3Way-Ball Valve

VITLAB Dispenser. Standard Operating Procedure (SOP)

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Resistance thermometer Model TR10-E, for additional thermowell

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Design and application

JUMO dtrans p20 DELTA

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Important instructions

Control and Terminal Box Type A21-**-*****

Measuring insert for resistance thermometer Model TR10-A

Transcription:

ERICHR I C H O T T EX T... AT Sensors with switching function Identification II 2 G Ex db eb mb IIC T-T6 EU-type examination certificate Ambient temperature range Nominal current Temperature switch point Nominal voltage PTZ 6 ATEX 0024-45 C - +80 C 0 A +5 - +80 C 20 V Protection degree IP 66 Temperature fuse Temperature monitor TB...AT TR...AT TS...AT TW...AT Temperature sensor This temperature sensor without seperate power supply is available as temperature fuse, controller, monitor or as limiter. Destined for the installation in the Ex-area, the temperature acquisiton takes place via a Pt00- sensor in the die-cast aluminium sheet and is directly mounted on the object to be measured. Devices and protective systems for the intended use in explosion prone areas Guideline 204/4/EU. Erich Ott GmbH & Co. KG Partner für den Ex-Bereich D-6589 Wiesbaden Rüdigerstrasse 5 Telephone +49 (0) 6-76 9 Telefax +49 (0) 6-7 462 mail info@erich-ott.de web www.erich-ott.de

Sensors with switching function EX T... AT TABLE OF CONTENT.0 General... 2. Basic equipment... 2.2 Range of application... 2. Temperature controller... 2.4 Temperature monitor... 2.5 Temperature fuse... 2.6 Temperature limiter... 2.7 Safety-related information... 2.8 Cables and leads... 2.9 Compensatory circuits and interference suppression measures... 2 2.0 General technical data... 2.0 Production number... back page. Type code... back page.2 Temperature classes... back page 4.0 Installation site... back page 5.0 Connection plan... back page 6.0 Protective measure... back page 7.0 Nameplate... back page Warning The installation, configuration and commissioning may only be carried out by accordingly trained persons. the on-site installation and safety regulations must be considered. Restriction We reserve the right for technical changes. Changes, aberrations and printing errors do not justify any claim for damage. For safety components and systems the relevant standards and regulations must be considered as well as the according operating and installation instructions. Installation notes For the deployment / operation the EN 60079-4 ff and the applicable deployment regulations as well as the generally recognized rules of technique and this operation manuell are standard. The sensors, temperature controllers, temperature fuses, and temperature limiters of the type series Ex T... AT are element of a heating system and audited in connection with the manufacturer s declaration combined with the other components. Only in compliance with this regulation and the relevant VDE guidelines the EC declaration of conformity is valid. In case of doubt the manufacturer should be consulted or the relevant expert for the system should be questionned. The devices may not be thrown or fall down. If a deformation is detected on the device, it must be sent back for examination. For operation of the devices in series connection, with phase angle control not only the effective current is decisive but the minimum resistance of the load must not fall short. The interconnection of individual licensed components to one heating corresponds to a new unit. For their proper installation generally the temperature behaviour etc. must additionally be re-assessed. Miscellaneous - Disassembly takes place in reverse order than the assembly. - On the basis of the low heavy metal content a defective device must be disposed of as hazardous waste. - The device is irreparable. - An operation is not permitted. - If no company standard is available for the installation on the part of the operator, please inform about the kind of application. - An application against our recommendations is not permitted. - In the event of non-compliance of the operating instruction the guarentee expires. Maintenance For the maintenance/ service/ examination the regulations of the EN 60079-4 are relevant. Service The equipment is maintenance-free. Read these operating instructions before you take the device into operation. Keep these operating instructions at a place accessible to all users at any time. Please support us to improve these operating instructios. We are grateful for your suggestions. Please contact us for technical queries! TELEPHONE: +49 (0)6 76 9 TELEFAX: +49 (0)6 7 462 E-Mail: info@erich-ott.de

ERICHR I C H OTTT T.0 GENERAL Characteristics easy installtion cost-effective sturdy design several temperature ranges available.5 TEMPERATURE FUSE The temperature fuses are irreparably damaged after the exceeding of the temperature. The construction of a heating apparatus should be designed in order that other monitoring systems in the heater always respond earlier, so that no unacceptly high temperature exists at the temperature fuse. Scope of application especially where the value of the temperature fuse usually is not to be expected und where the max. longer existing value 0 K lies below the nominal value of the temperature fuse..6 TEMPERATURE LIMITER In how far the built-in temperature fuse or rather the reset limiter can after the installation of the heating be also used as limiter for the complete heating, can only be decided by an expert on site.. BASIC EQUIPMENT The temperature acquisition acts directly on the switching element. The two-wire technique switches load of 20 V, 0A. Depending on the design temperature controller, temperature fuse or temperature limiter, all rated values are fixed..2 RANGE OF APPLICATION Wherever no high standards are set for the accuracy of the temperature acquisition of heatings and where the media to be measured have a mass that is much larger than that of the sensor, the temperature change should be below 0,2 K/min. The installation on a metal surface is recommended.. TEMPERATURE CONTROLLER The sensor as temperature controller (Ex TR...) is switched in row with the acive heater and has not separate voltage supply. Also suitable as monitor (see chapter.4). It is to be noted, that it is a high power contact. The switching hysteresis is about 9 K..4 TEMPERATURE MONITOR The temperature monitor (Ex TW) opens the contact at under temperature. It signals the blackout of a heating. Same case of application as temperature fuse, but with the following advantages: it can be resetted and the constant temperature load is about 2 K below nominal value. It has though a larger mass..7 SAFETY-RELATED INFORMATION The limiter can be resetted manually. The switching element of the limiter is integrated for millionfold in domestic appliances and office equipment. The additional mechanism for automatic return is modified so that a triggering caused by temperature rise can not be avoided. The limiter can only be switched on again, when the temperature has fallen below 40 C. The complete Atex approval documentation can also be inspected under www.erich-ott.de as PDF document..8 CABLES AND LEADS The supply line, if it is longer than 5m, should have an outer braiding for EMV suitable installation, that is connected with PE at the feeding point. The minimum cross-section is,5 mm². The voltage drop at 20 V is not to be determined according to the effective current, but as if the load resistor was connected directly to the net. At three-phase current moderate distribution the neutral conductor must be fully resilient..9 COMPENSATORY CIRCUITS AND INTERFERENCE SUPPRESSION MEASURES PE-conductors and N-conductors must be led seperately from the switch cabinet. If this connection is disconnected in the switch cabinet, it must be possible to check the insulation value with 0,5kV. According to the regulation the larger value applies. 2.0 GENERAL TECHNICAL DATA Nominal value 20 V or lower (but not below 2 V) Temperature setpoint see table (chapter.2) Nominal current 0 A Design Aluminium cabinet sealing technique Ambient temperature -45-80 C qualified according to table (chapter.2) Dimensions L x W x H (mm) 95 x 40 x 5 for limiter 74 x 7 x 28 for controller and fuse Electrical connection PTFE cable, x,5 mm²,,2 m lang, 5-6 mm Ignition protection category (Gas) II 2G Ex db eb mb IIC T-T6 according to design (see table, chapter.2) Protection class IP66 / DIN 40 050 Standard conformity The equipment meets the requirements of the EN 60079-0:202+A:20, EN 60079-:204, EN 60079-7:205, EN 60079-8:205 Wiring configuration brown - switching element blue - switching element yellow/green - cabinet EU-type examination certificate PTZ 6 ATEX 0024 Identification 044 II 2 G Ex db eb mb IIC T-T6 according to design (see table chapter.2) 2

Sensors with switching function EX T... AT.0 PRODUCTION NUMBER xxxx / 0.0. TYPE CODE Ex T AT 2 Year Month Serial number 4.0 INSTALLATION SITE The sensors of the type series Ex T.. AT are destined for the use in installations, for example in instrument protective cabinets, on the pipeline etc. Top view 40 0 95 87 5 7 28 74 66 B Section R S Temperature fuse W Temperature monitor 5 28 2 Nominal temperature (see table) - Standard s with protective hose Tabelle Typ Nominal temperature value C Ex TR 0 0 50 70 80 00 Ex TW 5 0 40 Ex TB 94 00 2 75 Ex TS 0 20 temperature controlling medium 5.0 CONNECTION PLAN br δ bl temperature controlling medium Please observe the table (chapter.2). Example: with a nominal temperature of 2 C, without protective hose: Ex T B 2 AT 2.2 TEMPERATURE CLASSES The temperature classes consider, also in optimal use, the temperature rise after the switching off. 6.0 PROTECIVE MEASURE The protective measure for the heating circuits is grounding (equipotential bonding). Due to often long supply lines and corresponding capcitive leakage currents, which can significantly increase because of the humidity saturation of the insulation, residual current circuit breakers with 00 ma are advisable. Depending on brands, residual current circuit breakers respond differently. 7.0 NAMEPLATE Zone division Zone 2 Zone Temperature class T6 T5 T4 T T2 T Max. admissible ambient temperature 70 85 20 80 - - 2 4 PARTNER FÜR DEN EX-BEREICH RÜDIGERSTRASSE 5 D - 6589 WIESBADEN 044 II 2 G Ex TR.. AT Regler Nennspannung 20 V ~ Nennstrom 0 A Temperaturnennwert C Ex db eb mb IIC T PTZ 6 ATEX 0024 Fertigungs Nr. 5 6 7 8 9 - Type designation 5- Auditing body 2- Nominal current 6- Ex- identification - Ignition protection category 7- Nominal voltage 4- Production number 8- Temperature rating 9- EU-type examination certificate

www.erich-ott.de ERICHR I C H O T T Erich Ott GmbH & Co. KG Partner für den Ex-Bereich D- 6589 Wiesbaden Rüdigerstrasse 5 Telefon +49 (0) 6-76 9 Telefax +49 (0) 6-7 4 62 mail info@erich-ott.de web www.erich-ott.de Ex T AT-0-70404-e