NIDEC COPAL ELECTRONICS CORP.

Similar documents
NIDEC COPAL ELECTRONICS CORP.

NIDEC COPAL ELECTRONICS CORP. 1 / 7. Model No. Issuing Date

TF037C MICRO BLOWERS FEATURES STANDARD SPECIFICATIONS

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information

Electromagnetic Buzzers

Electromagnetic Buzzers

Applications. Car audio. Robo

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

Tube: End-cap: Core: Solder: Lead-free glass Nickel plated brass Ceramic Sn-1.5Cu. Pb87.5-Sn10-Ag2.5* ma less than 1 A.

56 mm sq inch sq.

FrelTec GmbH. SMD Power Inductors

BLU Series. RoHS-Compliant. Brushless DC Motor and Driver Package. Features

Lead-free glass Nickel plated brass 62 ma 1.25 A Over 1.25 A 3 A Epoxy resin 62 ma less than 1 A. Tube: End-cap: Solder: Adhesive: Marking: 1 A 3 A

56 mm sq. (2.20 inch sq.)

MCF3 25CT Inrush-withstand

Lead-free glass Nickel plated brass Ceramic 100 ma 15 A. Tube: End-cap: Core: Solder: 200 A. Marking: 100 ma 8 A Over 8 A 20 A. Rated breaking current

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

DRL-1 Series Instruction Manual

MCF3 DC86V11CT Inrush-withstand

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

3M CP2 Press-Fit Headers and Sockets, 2 mm

DRB-1 Series Instruction Manual

MondoStep 7.8. High Performance Microstepping Driver. User s Manual. Version PROBOTIX All Rights Reserved

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

G3PE-Single-phase. Solid State Relays for Heaters

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

JINLONG MACHINERY & ELECTRONICS CO., LTD. PRODUCT SPECIFICATION

Low Differential Pressure Gage

RoHS-Compliant. Brushless DC Motor and Driver Package BX Series

TX³ RCCBs 2P up to 100 A

DX³ RCCBs - ID 4P up to 100 A

DC I/O Conversion Module FA1-TESV32XY FA1-TESV38COM User's Manual

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

RoHS-Compliant. Watertight, Dust-Resistant Motors FPW Series

HWS 15A-150A Series. Instruction Manual

JINLONG MACHINERY & ELECTRONICS CO., LTD. PRODUCT SPECIFICATION

Driver & Stepping motor package CSA Series. Operation Manual

C Series Mid Voltage Application

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

DX³ 4-pole RCBO 6000 A/10 ka

RX 3 M.C.B A up to 63 A

CGA Series Automotive Grade Capacitors

5-Phase Stepping Motor and Driver Package RK Series

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

RX 3 M.C.B A up to 63 A

Phase + Neutral, neutral on left side

2: A, B 3: A, B, Z 4: A, A _, B, B _ 6: A, A _, B, B _, Z, Z _

Operating Manual For Stepper Driver

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

CUSTOMER: PART NO: FD1212-A1051E2AL. DATE : January CUSTOMER APPROVAL. Taiwan. Mainland China(F1)

0.6A, 1.5A, 2.25A, 3A/Phase

TECHNICAL SPECIFICATION OF THERMAL PROTECTOR, ST-22

2 Phase Hybrid Stepping Motor Driver SD-2H044MA Series

TV-5, TV-8 rated 10mm flat power relays Silent type is available

High-power Solid State Relays G3PH

PRODUCT SPECIFICATION

Spec.No. CBF2525-VBVB-01E-1. Orion Model CBF2525-VBVB-01. Date Aug APPD CKD DWN. Kuroiwa Yamada Takei Takahashi ORION MACHINERY CO., LTD.

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

LS200 Series Instruction Manual

42 mm sq inch sq.

up to 63 A (1 module per pole)

Below, you can see the warning symbols used throughout the manual and their meaning.

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS BLOWER. DIMENSIONS : 45X45X9 mm M O D E L : GB0545AFV1-8

Lead-free glass Nickel plated brass Ceramic Tin plated copper Sn-1.5Cu Pb87.5-Sn10.0-Ag2.5* SOC NSD9 D32V [rated current]

Safety Standards. Model Number:

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 40X40X10 mm M O D E L : KD1204PFS2-8

INTRODUCTION WARNING SIGNS AND THEIR MEANINGS

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

Namiki Precision Jewel Co.,Ltd. Applications

High-power Solid State Relays G3PH

MYPMA01218RCF-CAB Non-isolated type

US Series Single-Phase 110/115 VAC Single-Phase 220/230 VAC

KL-8070D. Fully Digital Stepping Driver. Table of Contents 1. Introduction, Features and Applications...1 Introduction...1 Features...

Model Number Structure

Pressure Sensor/PS-A (ADP5)

EZS. Motorized Linear Slides. Series. RoHS-Compliant

RHINO MOTION CONTROLS

Power Modules (Power Supplies with Ultra-low Standby Power Consumption) DC V

ZWS-BP Series. Instruction Manual. TDK-Lambda. ZWS-BP Series. Instruction Manual A C

Phase + Neutral, neutral on right side

MEMS Gauge Pressure Sensor

FrelTec GmbH. Multilayer Ceramic Chip Inductors SMD

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

DC-DC Converter Specification MPD6S022S

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

MPM0527SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

Read and understand this manual for safely usage.

User s Manual. For M542. High Performance Microstepping Driver. Version All Rights Reserved

Low Differential Pressure Gage

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

BPM2417SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

ZWD100PAF. Conformity to RoHS Directive

Brushless Motors. BMU Series. Connector Type NEW. Easy speed control, easier to use. New connector type with smart wiring.

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

PKG-341-MBC08-PS-CBL System Diagram and Specifications

<Designed to meet harmonic current regulations> Board type, ultra-small size, and low cost

Transcription:

1 / 8 Specifications Model No. TF037F-2000-F Issuing Date Aug.1, 2017 1.Scope This document applies to Blower TF037F-2000-F (hereinafter referred to as "PRODUCT"), a product of NIDEC COPAL ELECTRONICS CORP. (hereinafter referred to as "NCEL"). Reference driving circuit :NCEL's standard driving circuit 2.Specification (Note1) Unless otherwise specified, the environmental conditions are 23 ±5,normal humidity, and atmospheric pressure range 90 to 106kPa. (Note2) Measuring conditions : Driving circuit = NCEL's standard driving circuit, Supply voltage = DC24V, measurement equipment = NCEL's standard equipment (Note3) The below specifications specify the characteristics of the Blowers at the time of shipment. (Note4) Please contact us if you'd like to operate the PRODUCT outside of specifications. No. Items Specification Remarks 1 Rated Voltage DC 12 24 V 2 Direction of Rotation CCW (Counter-Clockwise) Looking down from the air inlet. 3 Kind of Gas Air Noncorrosive gas 4 Configuration Motor with Centrifugal Blade Without driving circuit 5 Type of Motor DC Brushless Motor 6 Number of Poles 8 Poles (4 pole pairs) 7 Drive System 3 Phase, Bipolar 8 Bearings Aero-Dynamic Bearings 9 Impeller Centrifugal Turbo Blade 10 Outline Drawing : 6404-00635-00 11 Mounting Direction Shaft vertical to ground, air inlet facing upwards Please refer to attached drawing. No vibration, shock, or gyration is to be applied during operation.

2 / 8 No. Items Specification Remarks 12 13 14 Max. Input Coil Current Rated Power Supply Current Rated Power Consumption 3.0 A rms max. Excluding inrush current. 0.67 A max. at 2.0kPa, 100L/min, DC 24V 16.1 W max. at 2.0kPa, 100L/min, DC 24V 15 Rated Air Flow 100 L/min at 2.0kPa 16 Minimum Air Flow 10 L/min 17 Rated Pressure 2.0 kpa at 100L/min 18 19 20 21 Maximum Pressure Rated Rotation Speed Min.Rotation Speed Max.Rotation Speed 4.5 kpa Absolute maximum pressure. 31,000 r/min (reference value) at 2.0kPa, 100L/min 10,000 r/min 45,000 r/min Pressure-air flow must be within the "area of use" specified in "5. Operating Range" on P.5. 22 Torque Constant 0.0020 0.0026 N m/a (reference value) 23 Acoustic Audible Noise 65.0 db(a )max. at 2.0kPa, 100L/min. Measured at 1m from air inlet. Include background noise 15dB(A). 24 Coil Resistance 0.36 0.66 ohm (reference value) at 20 (Between 2 phase) 25 Coil Inductance 17 23 μh (reference value) at 20, 10kHz (Between 2 phase) 26 Insulation Class Class E JIS C 4003 27 Insulation Resistance 1M ohm min. DC500V,between terminal pins and plate JIS C 4003 28 Dielectric Strength Leak current to be less than 1mA. AC600V for 1sec. between terminal pins and Plate. JIS C 4003 29 Weight 72 g (reference value) 30 Rotor Inertia 19 g cm 2 (reference value) 31 Max. Axial Loading 3N max. Maximum axial force applying to the intake (upper housing)

3 / 8 No. Items Specification Remarks 32 33 34 35 36 Operating Temperature Range Operating Humidity Range Storage Temperature Range Storage Humidity Range Resistance to Vibration 0 to 50 10 to 95%RH No condensation -20 to 60 10 to 95%RH No condensation The Blower shall satisfy Specification No.12 28 after the following test. Kind of Sweep Vibration Frequency Range 10 22Hz @ amplitude 1mm @ acceleration 22 50Hz 19.6m/s 2 (2G) Non-operating Sweep To-and-fro, approx. 5min. X, Y, Z directions, 60min. Test Time each The Blower shall satisfy Specification No.12 28 after the following test. Acceleration 294m/s 2 (30G) 37 Resistance to Shock Pulse Width 6ms Non-operating Shock Wave Semi-sinusoidal wave Number of Shock X, Y, Z, directions, once per each direction

4 / 8 3.Interface SM12B-PASS Air Inlet Pin No. Symbol 1 Vcc 2 H2-3 H2+ 1 12 4 H3-5 H3+ 6 H1- Manufacturer J.S.T. Mfg. Co. Ltd. 7 H1+ Part No. 8 GND GND Signal Hall Element Power Supply (+12V) Hall Element 2 Output Hall Element 3 Output Hall Element 1 Output Mating Connector Manufacturer J.S.T. Mfg. Co., Ltd. (insulation displacement 12PAF-6S connector) (retainer:pafs-12v-s) 9 TH 10 V 11 W 12 U Thermistor Output Motor Coil (V) Motor Coil (W) Motor Coil (U) Part No. PAP-12V-S (crimp type) (contact:sphd-001t-p0.5) (Note4) Either IDC or crimp type can be used as a mating connector. (Note5) Parts used for thermistor output; Manufacturer : TDK Corp. Part No. : NTCG164BH103JT (Note6) Parts used for hall element output; Manufacturer : Asahi Kasei EMD Corp. Part No. : HW-105A 4.Timing Chart H1+ H L H1- H L H2+ H L H2- H L H3+ H L H3- H L U V W + - + - + - 0 60 120 180 240 0 15 30 45 60 300 360 75 90 [deg] Electrical degree [deg] Mechanical degree

0 5 / 8 5.Operating Range The following graph is provided for reference only. Values are not guaranteed. Conditions: Ambient temperature 23±5, normal humidity, atmospheric pressure (100±2kPa). Make sure the thermistor temperature does not exceed 80 during blower operation. (Thermistor resistance value R (80 deg C) =1.177kΩ) Operating Range at DC24V (1atm) 5.0 40,000r/min 4.0 35,000r/min Pressure [kpa] 3.0 2.0 1.0 30,000r/min 25,000r/min Area of use 0.0 0 20 40 60 80 100 120 140 160 Air Flow [L/min] Operating Range at DC12V (1atm) 5.0 4.0 35,000r/min Pressure [kpa] 3.0 2.0 1.0 30,000r/min 25,000r/min Area of use 0.0 0 20 40 60 80 100 120 140 160 Air Flow [L/min]

6 / 8 6.Manufacturing Code TF037F-2000-F 6 3 1 A - XXX X NIDEC COPAL ELECTRONICS CORP. Control no. : alphabet (A-Z) Date of manufacture : refer to Chart 1 Month of manufacture : refer to Chart 2 Year of manufacture : last digit of the year (A.D.) Chart 1 Date 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Code 1 2 3 4 5 6 7 8 9 A B C D E F G H J K L Date 21 22 23 24 25 26 27 28 29 30 31 Code M N P Q R T U V W X Y Chart 2 Month 1 2 3 4 5 6 7 8 9 10 11 12 Code 1 2 3 4 5 6 7 8 9 O N D 7.Warranty 7-1.Warranty Period Warranty period of the PRODUCT is 1 year from delivery. 7-2.Warranty Scope (1) In case a defect is found in the PRODUCT during the above warranty period and NCEL is responsible for the defect, NCEL will either repair or replace the defected PRODUCT free of charge. However, in the following cases, the PRODUCT will not be covered by warranty. Defects caused by inappropriate conditions, environments, handlings, and use which are not specified in this specification. Defects caused by your equipments and/or software. Defects caused by modifications and/or repairs which were not done by NCEL. Defects which could have been avoided if the PRODUCT was used accordingly to this specification. Defects which were unpredictable with the scientific or technical level of NCEL at the time of shipment. Defects caused by external factors such as natural hazards (fire, earthquakes, floods) or electrical surges.

7 / 8 (2) 7-3.Product Application 8.Notes (1) All values are measured with NCEL's standard equipments unless otherwise specified. (2) The PRODUCT is compliant with RoHS directives which went into effect July, 2011. Designated hazardous substances are lead, mercury, cadmium, hexavalent chrome, brominated flame retardants (PBB, PBDE) and its compounds. (3) (4) NCEL will be responsible for the PRODUCT only in which the coverage will be limited to Clause 7-2. (1). NCEL shall not be liable for customer's equipment damages, opportunity losses, or lost earnings caused by defects of the PRODUCTS. The user shall indemnify NCEL and hold NCEL harmless from any liability or damage whatsoever arising out of any action not in accordance with this specification. The PRODUCT is designed and manufactured for general-purposes. Please do not use in applications such as nuclear power, aviations, railroads, or medical equipment where great effect to human lives or wealth are expected. However,if NCEL agree with the customer the usage of the PRODUCT in such applications, NCEL will warrant the PRODUCT in the same scope described in "7. Warranty" in this specification. The PRODUCT is compliant with Directive 2006/122/EC of the European Parliament (Council Directive 76/769/EEC(30th amendment)) which restricts the use of PFOS. Contents of this document may be changed without notice. The production of the PRODUCT may be discontinued without notice. Please confirm with your local contact before ordering. (5) Please check if the PRODUCT operates normally at every start-up and during operation. (6) Please provide safety measures to prevent damages in case of product failures. (7) (8) Performance cannot be guaranteed in case the PRODUCT is used beyond the specification or the PRODUCT is modified. Depending on the conditions or the environment, functions or performances of the PRODUCT may not be satisfied when the PRODUCT is used with other equipments. (9) Please do not use the PRODUCT in applications to protect the body. (10) Please protect the PRODUCT from condensation. (11) Please use the correct supply voltage to operate the PRODUCT. (12) Do not disassemble or modify the PRODUCT. (13) Turn off the power immediately and stop using the PRODUCT in the following cases. In case water or foreign substances get into the PRODUCT. In case the PRODUCT is dropped or the housing is broken. In case unusual odor, abnormal noise, or smoke are generated from the PRODUCT.

8 / 8 (14) Do not use or store in the following conditions; Humid, dusty, or poorly-ventilated area. Areas where the temperature is expected to rise (direct sunlight, etc.). Areas with corrosive gas or flammable gas in the surrounding air. Areas where vibration, shock, or rocking motion is applied directly to the PRODUCT. Areas where the PRODUCTS may be splashed with water, oil, or chemicals. Areas where static electricity can easily be built up. (15) Make sure the wiring is done properly. (16) Turn off the power of the PRODUCT and any equipment attached to the PRODUCT when putting on or taking off the cables. (17) (18) (19) Install the PRODUCT using cushioning materials such as vibration dampeners. Please contact us if you have any questions regarding installation. Do not block the air inlet and outlet (3 places). Please contact us if you have any questions regarding the air inlet and outlet. Vibration or audible noise level may change over time due to contamination of the blade. Please provide dust-proof constructions around the PRODUCT. (20) Please advise us in case the driving circuit will be designed at the customer's side. (21) Please connect and don't use air inlet of this product (2 places) in series.