Test report No

Similar documents
Test report No

Test report No

Test report No

European B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd

Test report No

Test report no

Germany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7

Test report No

Classification report No K1

Test report no

Test Report No

Test report no

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

TEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

Catalogue Partition rooms flexibly. Protect personal privacy. Curtains. Screen Systems

FIRE TEST REPORT FH 5154

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

Sound-absorbing spacer Sorp10

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

Report Test Report

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

E/ECE/324/Rev.2/Add.106/Rev.6/Amend.5 E/ECE/TRANS/505/Rev.2/Add.106/Rev.6/Amend.5

Title: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN : Report No: A

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

FIRE TEST REPORT FH 5728

Title: WF Report No:

Determination Of Fire Effluents From Products On Railway Vehicles

E/ECE/324/Rev.2/Add.117/Amend.1 E/ECE/TRANS/505/Rev.2/Add.117/Amend.1

Evidence of performance Reduction of impact sound pressure level by floor coverings

FIRE TEST REPORT FH 5078

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:

Test Report /Al (Results with Batch 1) Vastern Timber Company Ltd. Wootton Bassett, Swindon

MITRAS MATERIALS GMBH

No carcinogenic nitrosamine generating raw materials are used.

Inspection Report. Coating name: IGP HWFclassic IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number:

EU Mutual Recognition Technical Requirements

InnoBYG small scale demonstration tests - Part 2

InnoBYG small scale demonstration tests - Part 1

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

System Test Report Fitness for Use and Durability

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen

Test report. About the effect of Lambda System Cleaning Products. No

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

Confirmation: / 22 March 2013

13 th December Title: The Fire Resistance Performance Of Doorsets When Fitted With Perko Powermatic R100 Jamb Mounted Concealed Door Closers

TEST REPORT MEDICAL VEHICLES AND THEIR EQUIPMENT TABLE FOR AMBULANCE STRETCHER

INVESTIGATION OF DENTAL LUBRICANTS

ASTM E 1354 Caloric Content Determination of "3M Polyurethane Adhesive Sealant 540"

FLASH POINT TESTER. Instruction Manual. 0. Health and Safety Advice. 1. Introduction

PRODUCT EVALUATION REPORT

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

FIROFLEX IP. Synthetic rubber for secure protection against the formation of condensation

No e This is a translation of Test Report Summary dated 23 April 2007.

Test Report Order No _A1 / Part Hessisch Oldendorf. Order: Test of the electrostatic properties of a resilient floor coverings coated

Product information. COLORTHERM Red 110 M. Description. Specification. Specification. Red pigment

Product information. COLORTHERM Yellow 30. Description. Specification. Specification. Yellow pigment

Product Information. Bayferrox 640. Description. Specification. Brown pigment

Product Information. Bayferrox 610. Description. Specification. Specification. Brown pigment

Report Number BTC 12024F

RENOSAFE FireProtect 46, 68 Fire resistant hydraulic fluid, based on new ester and additive technology, Type HFDU

} Rev.1/Add.52/Rev.2/Amend.2

Product Information. Description. Specification

Synthetic EP air compressor oils based on PAO, for turbo, screw, vane and piston compressors; High-performance synthetic, PAO-based hydraulic fluids

Trailer EBS E 98/91/EG dated ECE-R 105 including amendment 04 and Chapter ADR 2009

PRODUCT INFORMATION RENOLIN DTA. Lubricating and hydraulic oils. Description. Advantages. Application. Specifications

Black pigment - High Performance micronised. Synthetic iron oxide Fe 3 O 4 Pigment black 11 (77499)

TEST REPORT. No. 284a/14

PLANTOGEAR S. Environmentally acceptable lubricating oil and EP industrial gear oil based on synthetic saturated esters.

CERTIFICATE of Product Conformity (QAL1 )

20 HUBER+SUHNER RADOX SOLAR

PLANTOGEAR S. Environmentally acceptable lubricating oil and EP industrial gear oil based on synthetic saturated esters.

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces

Designed to prevent condensation and energy losses

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

GROUP WORKING WORKING PAPER. International FIRST MEETING. related tests SUMMARY. 1.1 independent. The DGP also may 1.2. The report, strategies. 1.

VAUTH ANALYSING. TESTING. CERTIFYING. aviation components

oééçêí=çå=cáåçáåöë= OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018

SOUTH AFRICAN NATIONAL STANDARD

Translation from the German original, not verified by the Deutsches Institut für Bautechnik. Zulassungsstelle für Bauprodukte und Bauarten

Synthetic iron oxide α - Fe 2 O 3 Pigment red 101 (77491)

FIRE REGULATION IN FURNITURE WORLD OVERVIEW

Certificate: _01 / 20 August 2013

Test report No.: VU

RECYCLABILITY EVALUATION PROTOCOL FOR PE FILMS

Deutsche Akkreditierungsstelle GmbH

VdS-Guidelines for water extinguishing systems. VdS en. Sprinkler Pumps. Requirements and test methods. VdS en : (03)

DEUTSCHE NORM DIN 8077

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

EC type-examination of SITEMA Safety Brakes by DGUV Test

Transcription:

Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2014-1940 for applying of a required Verwendbarkeitsnachweis Issued 23rd October 2014 Applicant Hewlett Packard 16399 W Bernardo Dr. 92127 1899 San Diego USA Date of order: 08th October 2014 Date of sampling Date of arrival: 25th August 2014 Date of test 03rd October.2014 Order official taking out of the sample from a representative of the Exova Warringtonfire, Frankfurt Testing of the flammability (building class B1) according to DIN 4102-1 (May 1998) Description / designation of the test object Productname: HP PVC-free Durable Wall Paper Description of the relevant test procedure DIN 4102 part 1 (Mai 1998) This test report did t replace the required Verwendbarkeitsnachweis. It is only used for issuing the Verwendbarkeitsnachweis. Registered Office: Exova GmbH, Industriepark Höchst, C369, Frankfurt, D-65926, Registered Company No. HRB 83049 Ust-Id Nr. DE259957713

Test report No. 2014-1940 issued 23rd October 2014 Page 2 of 9 1. Description of the test material Product Name: Material: Farbe: Intended end use of product: HP PVC-free Durable Wall Paper Coated wall paper with a scim backing white, red, black Wall covering 1.2 At the specimen preparation in the Exova Warringtonfire, Frankfurt determined values: Wall covering Colour : white red black Thickness: 0, 47 mm 0, 47 mm 0, 47 mm Square weight: 276 g/m² 286 g/m² 284 g/² Adhesive: Portion of used adhesive: Brillux B1 Sample 57g/m² Area of use: Wall covering coulred in white, red and black fixed on plasterboard panel demand DIN 18180, Thickness 12,5 mm (analogy DIN 4102-16 4.3.c). Testing after clima storage at 23 C and 50% rel. hum. L. moist

Test report No. 2014-1940 issued 23rd October 2014 Page 3 of 9 2. Test results 2.1. Brandschacht test according to DIN 4102-1: Sample A: Sample B: Sample C: Material tested in production direction (Colour: white) Material tested crosswise to the production direction (Colour: red) Material tested in production direction (Colour: black) Test results of the Brandschacht tests part 1 Liner measurements test sample A B C 1. test arrangement according to DIN 4102 part 15, table 1 2 2 2 2 flame height max. over lower sample edge time 1) cm 60 60 70 1:08 1:19 1:21 3 ascertainments on the front side Flaming/glowing time 1) 0:09 0:12 0:08 4 melting / burning through Not Not Not time 1) occured occured occured ascertainments on the back side 5 Flaming/glowing time 1) 6 discolouring time 1) 7 8 9 10 11 12 burning droplets begin 1) extent occasional dripping of material constant dripping of material separating from burning sample parts begin 1) occasional separating parts constant separating parts 13 duration of burning on the sieve tray (max.) influence on the burner flame by dripping of / separating material 14 time 1) earlier end of test 15 end of the fire scenario on the sample 1) 16 time of a possible resulted test stop 1) t occured t occured t occured ) time from start of test

Test report No. 2014-1940 issued 23rd October 2014 Page 4 of 9 Test results of the Brandschacht tests part 2 Zeilen Nr. 17 18 19 20 21 22 23 24 25 26 27 flaming after end of test duration number of sample front side of sample backside of sample flame length glowing after end of test duration number of sample place of occurrence lower sample part upper sample part front side of sample backside of sample cm min. s Measurements tests sample A B C D 0:00 0:00 0:00 0:00 0:00 0:00 0:00 0:00 28 29 30 smoke density < 400 % x min > 440 % x min diagram in annex. --/-- --/-- 50 --/-- 118 125 131 1 2 3 31 32 33 34 35 36 residual length single results average of the single results foto of the sample on page smoke temperature max. of the average results time 1) diagram in annex. cm cm C 45 / 42 40 / 40 46 / 44 43 / 42 41 43 48 5 5 5 48 / 48 48 / 48 15 32 44 5:17 2:25 4:55 1 2 3 1) time from start of test Remarks:

Test report No. 2014-1940 issued 23rd October 2014 Page 5 of 9 2.1.3 Appearance of the specimen after the test: Sample A Sample B Sample C

Test report No. 2014-1940 issued 23rd October 2014 Page 6 of 9 2.2.1 Normal flammabilty test according to DIN 4102-1: Test with edge ignition without deposit Flame application on: lower sample edge Edge ignition (Colour: white) Sample No. Time from start of test 1 2 3 4 5 Ignition point 3 2 Reaching the measuring mark within 20 seconds Selbstverlöschen der Flamme[s] 18 15 Self extinguishing of the flame [s] 25 20 Max. flame height [mm] 7 8 Time [s] 3 - After flame time [s] - - After glow time [s] - - Flames extinguished after [s] low smoke production Smoke development (visuell impression) Separating from burning material - - Time [s] - - Remarks: remarks (Colour: red) Proben-Nr. Sample-. 1 2 3 4 5 Time from start of test 3 3 3 3 3 Ignition point [s] Reaching the measuring mark within 20 seconds 15 16 16 15 15 Self extinguishing of the flame [s] 20 20 20 20 20 Max. flame height [mm] 8 8 8 8 8 Time [s] - 1 1 - - After flame time [s] - - - - - After glow time [s] - - - - - Flames extinguished after [s] low smoke production Smoke development (visuell impression) Separating from burning material - - - - - Time [s] - - - - - Remarks: remarks

Test report No. 2014-1940 issued 23rd October 2014 Page 7 of 9 2.2.1 Normal flammabilty test according to DIN 4102-1 Test with edge ignition without deposit Flame application on: lower sample edge Edge ignition (Colour: black) Sample No. 1 2 3 4 5 Time from start of test 3 3 Ignition point No No Reaching the measuring mark within 20 seconds 15 15 Selbstverlöschen der Flamme[s] 20 20 Self extinguishing of the flame [s] 7 8 Max. flame height [mm] - - Time [s] - - After flame time [s] - - After glow time [s] low smoke production Flames extinguished after [s] Smoke development (visuell impression) - - - - - Separating from burning material - - Time [s] - - Remarks: remarks

Test report No. 2014-1940 issued 23rd October 2014 Page 8 of 9 2.2.3 Appearance of the sample after the small burner test:

Test report No. 2014-1940 issued 23rd October 2014 Page 9 of 9 3. Assessment The material, described in chapter one fulfils the requirements of the building class B2 according to DIN 4102-1 (Mai 1998). The determined test results show that the material also fulfils the requirements according to DIN 4102-1 (Mai 1998). of the building class B1 4. Special comment The fire test result is only valid for the in chaper 1 described material in the tested colours, thickness and square weight, fixed on plasterboard panel only used with the adhesive of all mineral foundations with a gross density of 700±100 kg/m³ and more. According to the experiences of the test laboratory the test results also includes colors in between the tested ones. The material wasn't tested after an outside storage. In combination with other materials (for example coatings, deposits) the burning behaviour could be influenced unfavourable so that the classification above is t valid any longer. According to DIN 4102-1 the burning behaviour in combination with other materials has to be tested separately. This test report did t replace the required Verwendbarkeitsnachweis. It is only used for issuing the Verwendbarkeitsnachweis. Frankfurt, 23rd October.2014 H. Anders Dipl.-Ing. T. Zachäus Tester in charge Laboratory Supervisor This Test report is valid until 29.09.2019 The results of the tests relate only to the behaviour of the test sample which is designated on the top. Test reports are only allowed to be published or reproduced, t changed in form and ter without permission of the Exova Warringtonfire, Frankfurt. The abridged account of a test report is only allowed with the agreement of the von Exova Warringtonfire, Frankfurt.

Test report No. 2014-1940 issued 23rd October 2014 Page 10 of 9 This test report is a translation of the German version 2014-1940 (issued 23th October 2014). In case of doubt only the German version is valid. This test report contains 9 pages and 5 annex.

Annex 1 to the Test report Nr. 2014-1940 issued 23.10.2014 Sample No. A: Registered Office: Exova GmbH, Industriepark Höchst, C369, Frankfurt, D-65926, Registered Company No. HRB 83049 Ust-Id Nr. DE259957713

Annex 2 to the Test report Nr. 2014-1940 issued 23.10.2014 Sample No. B:

Annex 3 to the Test report Nr. 2014-1940 issued 23.10.2014 Sample No C:

Annex 4 to the Test report Nr. 2014-1940 issued 23.10.2014 Sample No.: D

Annex 5 to the Test report Nr. 2014-1940 issued 23.10.2014 Sample No E: