Technical Data Insulation for the LNG, Petrochemical and Process Industries
B2 33 Nominal Density EN ISO 845 kg/m 3 33 Initial W/m. K 0.020 Aged (25 weeks @ 70 C) W/m. K 0.026 Lower Limit C -180 Cream Parallel kpa > 180 Perpendicular kpa > 90 Parallel kpa > 350 Perpendicular kpa > 250 Friability ASTM C 421 (10 min.) % 30 Horizontal Burning EN ISO 3582 125 mm Brandkennziffer 5.3
B2 40 Nominal Density EN ISO 845 kg/m 3 40 Initial W/m. K 0.020 Aged (25 weeks @ 70 C) W/m. K 0.026 Lower Limit C -180 Cream Parallel kpa > 250 Perpendicular kpa > 150 Parallel kpa > 450 Perpendicular kpa > 350 Friability ASTM C 421 (10 min.) % 30 Horizontal Burning EN ISO 3582 125 mm Brandkennziffer 5.3
B2 60 Nominal Density EN ISO 845 kg/m 3 60 Initial W/m. K 0.021 Aged (25 weeks @ 70 C) W/m. K 0.028 Lower Limit C -180 Cream Parallel kpa > 430 Perpendicular kpa > 230 Parallel kpa > 690 Perpendicular kpa > 530 Friability ASTM C 421 (10 min.) % 30 Horizontal Burning EN ISO 3582 125 mm Brandkennziffer 5.3
HD 120 Nominal Density EN ISO 845 kg/m 3 120 Initial W/m. K 0.029 Aged (25 weeks @ 70 C) W/m. K 0.037 Parallel kpa 1200 Perpendicular kpa 1000 Parallel kpa 1400 Perpendicular kpa 1300 Friability ASTM C 421 (10 min.) % 10 Horizontal Burning EN ISO 3582 20 mm
HD 160 Nominal Density EN ISO 845 kg/m 3 160 Initial W/m. K 0.034 Aged (25 weeks @ 70 C) W/m. K 0.039 Parallel kpa 1900 Perpendicular kpa 1650 Parallel kpa 1750 Perpendicular kpa 1550 Friability ASTM C 421 (10 min.) % 10 Horizontal Burning EN ISO 3582 20 mm
HD 224 Nominal Density EN ISO 845 kg/m 3 224 Initial W/m. K 0.040 Aged (25 weeks @ 70 C) W/m. K 0.047 Parallel kpa 2950 Perpendicular kpa 2750 Parallel kpa 3000 Perpendicular kpa 2800 Friability ASTM C 421 (10 min.) % 5 Horizontal Burning EN ISO 3582 20 mm
HD 320 Nominal Density EN ISO 845 kg/m 3 320 Initial W/m. K 0.050 Aged (25 weeks @ 70 C) W/m. K 0.054 Parallel kpa 5750 Perpendicular kpa 5000 Parallel kpa 4900 Perpendicular kpa 4700 Friability ASTM C 421 (10 min.) % 5 Horizontal Burning EN ISO 3582 20 mm
HT 40 Nominal Density EN ISO 845 kg/m 3 40 Initial W/m. K 0.021 Aged (25 weeks @ 70 C) W/m. K 0.030 Operating Temperature Limits Upper Limit C +200 Lower Limit C -180 Grey Parallel kpa 230 Perpendicular kpa 150 Parallel kpa 490 Perpendicular kpa 340 Friability ASTM C 421 (10 min.) % 40
M1-CR 33 Nominal Density EN ISO 845 kg/m 3 33 Initial W/m. K 0.021 Aged (25 weeks @ 70 C) W/m. K 0.028 Parallel kpa > 180 Perpendicular kpa > 90 Parallel kpa > 350 Perpendicular kpa > 190 Friability ASTM C 421 (10 min.) % 40 Fire Propagation BS 476-6 Index of performance (I) not exceeding 12 and sub-index (i 1 ) not exceeding 6 (a) Surface Spread of Flame BS 476-7 Class 1 (a) Horizontal Burning EN ISO 3582 25 mm Oxygen Index EN ISO 4589-2 30 % Surface Burning Characteristics ASTM E 84 Flame Spread Index: 35 Brandkennziffer 5.3 Epiradiateur NF P92-501 M1 Vertical Burning DIN 4102-1 B1 (b) (a) These test results combined enable a Class 0 classification to the Building Regulations in England & Wales, Northern Ireland and the Republic of Ireland, and a Low Risk classification to the Building Standards in Scotland. (b)basedontestresultsinaccordancewithen13501-1.conversioninaccordancewithpublicationofmpa-nrwmaterialpru fungsamtnordrhein-westfalen.
M1-CR 35 Nominal Density EN ISO 845 kg/m 3 35 Initial W/m. K 0.021 Aged (25 weeks @ 70 C) W/m. K 0.028 Parallel kpa > 200 Perpendicular kpa > 110 Parallel kpa > 370 Perpendicular kpa > 230 Friability ASTM C 421 (10 min.) % 40 Fire Propagation BS 476-6 Index of performance (I) not exceeding 12 and sub-index (i 1 ) not exceeding 6* Surface Spread of Flame BS 476-7 Class 1* Horizontal Burning EN ISO 3582 25 mm Oxygen Index EN ISO 4589-2 30 % Surface Burning Characteristics ASTM E 84 Flame Spread Index: 30 Brandkennziffer 5.3 Epiradiateur NF P92-501 M1 * These test results combined enable a Class 0 classification to the Building Regulations in England & Wales, Northern Ireland and the Republic of Ireland, and a Low Risk classification to the Building Standards in Scotland.
M1-CR 40 Nominal Density EN ISO 845 kg/m 3 40 Initial W/m. K 0.021 Aged (25 weeks @ 70 C) W/m. K 0.028 Parallel kpa > 220 Perpendicular kpa > 140 Parallel kpa > 410 Perpendicular kpa > 200 Friability ASTM C 421 (10 min.) % 35 Fire Propagation BS 476-6 Index of performance (I) not exceeding 12 and sub-index (i 1 ) not exceeding 6 (a) Surface Spread of Flame BS 476-7 Class 1 (a) Horizontal Burning EN ISO 3582 25 mm Oxygen Index EN ISO 4589-2 30 % Surface Burning Characteristics ASTM E 84 Flame Spread Index: 25 Brandkennziffer 5.3 Epiradiateur NF P92-501 M1 Vertical Burning DIN 4102-1 B1 (b) (a) These test results combined enable a Class 0 classification to the Building Regulations in England & Wales, Northern Ireland and the Republic of Ireland, and a Low Risk classification to the Building Standards in Scotland. (b)basedontestresultsinaccordancewithen13501-1.conversioninaccordancewithpublicationofmpa-nrwmaterialpru fungsamtnordrhein-westfalen.
M1-CR 42 Nominal Density EN ISO 845 kg/m 3 42 Initial W/m. K 0.019 Aged (25 weeks @ 70 C) W/m. K 0.028 Parallel kpa 260 Perpendicular kpa 160 Parallel kpa 430 Perpendicular kpa 330 Friability ASTM C 421 (10 min.) % 30 Fire Propagation BS 476-6 Index of performance (I) not exceeding 12 and sub-index (i 1 ) not exceeding 6* Surface Spread of Flame BS 476-7 Class 1* Horizontal Burning EN ISO 3582 10 mm Oxygen Index EN ISO 4589-2 30 % Surface Burning Characteristics ASTM E 84 Flame Spread Index: 25 Epiradiateur NF P92-501 M1 * These test results combined enable a Class 0 classification to the Building Regulations in England & Wales, Northern Ireland and the Republic of Ireland, and a Low Risk classification to the Building Standards in Scotland.
M1-CR 45 Nominal Density EN ISO 845 kg/m 3 45 Initial W/m. K 0.020 Aged (25 weeks @ 70 C) W/m. K 0.028 Parallel kpa 300 Perpendicular kpa 190 Parallel kpa 490 Perpendicular kpa 380 Friability ASTM C 421 (10 min.) % 30 Fire Propagation BS 476-6 Index of performance (I) not exceeding 12 and sub-index (i 1 ) not exceeding 6* Surface Spread of Flame BS 476-7 Class 1* Horizontal Burning EN ISO 3582 10 mm Oxygen Index EN ISO 4589-2 30 % Surface Burning Characteristics ASTM E 84 Flame Spread Index: 25 Epiradiateur NF P92-501 M1 * These test results combined enable a Class 0 classification to the Building Regulations in England & Wales, Northern Ireland and the Republic of Ireland, and a Low Risk classification to the Building Standards in Scotland.
M1-CR 50 Nominal Density EN ISO 845 kg/m 3 50 Initial W/m. K 0.021 Aged (25 weeks @ 70 C) W/m. K 0.028 Parallel kpa > 310 Perpendicular kpa > 200 Parallel kpa > 510 Perpendicular kpa > 350 Friability ASTM C 421 (10 min.) % 35 Fire Propagation BS 476-6 Index of performance (I) not exceeding 12 and sub-index (i 1 ) not exceeding 6* Surface Spread of Flame BS 476-7 Class 1* Horizontal Burning EN ISO 3582 25 mm Oxygen Index EN ISO 4589-2 30 % Surface Burning Characteristics ASTM E 84 Flame Spread Index: 25 Brandkennziffer 5.3 Epiradiateur NF P92-501 M1 * These test results combined enable a Class 0 classification to the Building Regulations in England & Wales, Northern Ireland and the Republic of Ireland, and a Low Risk classification to the Building Standards in Scotland.
M1-CR 80 Nominal Density EN ISO 845 kg/m 3 80 Initial W/m. K 0.025 Aged (25 weeks @ 70 C) W/m. K 0.033 Parallel kpa > 700 Perpendicular kpa > 520 Parallel kpa > 850 Perpendicular kpa > 700 Friability ASTM C 421 (10 min.) % 20 Fire Propagation BS 476-6 Index of performance (I) not exceeding 12 and sub-index (i 1 ) not exceeding 6* Surface Spread of Flame BS 476-7 Class 1* Horizontal Burning EN ISO 3582 25 mm Oxygen Index EN ISO 4589-2 30 % Epiradiateur NF P92-501 M1 * These test results combined enable a Class 0 classification to the Building Regulations in England & Wales, Northern Ireland and the Republic of Ireland, and a Low Risk classification to the Building Standards in Scotland.
TB 120 Nominal Density EN ISO 845 kg/m 3 120 Initial W/m. K 0.029 Aged (25 weeks @ 70 C) W/m. K 0.037 ASTM D 1621 at +23 C kpa > 1200 ASTM D 1621 at -165 C kpa > 2800 Compressive Modulus ASTM D 1621 at +23 C MPa > 35 ASTM D 1621 at -165 C MPa > 85 Compressive Creep EN 1606 at +23 C over 1000 hrs % 0.5 EN 1606 at +23 C over 2000 hrs % 0.6 Permissible Load (PLD) EN 14620-4 (20 years) kpa 350 ASTM D 1623 at +23 C kpa > 1300 ASTM D 1623 at -165 C kpa > 1800 Tensile Modulus ASTM D 1623 at +23 C MPa > 55 ASTM D 1623 at -165 C MPa > 125 Friability ASTM C 421 (10 min.) % 10 Linear Expansion Coefficient ASTM D 696 K -1 45-55 x 10-6 Horizontal Burning Characteristics EN ISO 3582 Horizontal Burning Characteristics BS 4735 20 mm 10 mm 0 cm/min
TB 160 Nominal Density EN ISO 845 kg/m 3 160 Initial W/m. K 0.034 Aged (25 weeks @ 70 C) W/m. K 0.039 ASTM D 1621 at +23 C kpa > 1900 ASTM D 1621 at -165 C kpa > 5000 Compressive Modulus ASTM D 1621 at +23 C MPa > 65 ASTM D 1621 at -165 C MPa > 140 Compressive Creep EN 1606 at +23 C over 1000 hrs % 0.20 EN 1606 at +23 C over 2000 hrs % 0.25 Permissible Load (PLD) EN 14620-4 (20 years) kpa 800 ASTM D 1623 at +23 C kpa > 1550 ASTM D 1623 at -165 C kpa > 2500 Tensile Modulus ASTM D 1623 at +23 C MPa > 55 ASTM D 1623 at -165 C MPa > 135 Friability ASTM C 421 (10 min.) % 10 Linear Expansion Coefficient ASTM D 696 K -1 45-55 x 10-6 Horizontal Burning Characteristics EN ISO 3582 Horizontal Burning Characteristics BS 4735 20 mm 10 mm 0 cm/min
UK, Ireland & Gibraltar Kingspan Industrial Insulation Ltd Pembridge, Leominster, Herefordshire, HR6 9LA, United Kingdom General Enquiries Tel: +44 (0) 1544 388 601 Technical Advice Tel: 0808 168 7363 or +44 (0) 1457 890534 Australasia, Oceania and SE Asia as far west and north as, and including, Myanmar, China, Mongolia, Japan Kingspan Insulation Pty Ltd 266 Beringarra Ave, Malaga, WA 6090, Australia Tel: 1300 247 235 (for calls within Australia only) Tel: +61 8 6240 6200 (for calls outside of Australia) The rest of Europe (excluding Turkey, Malta & Cyprus) and Russia Kingspan Insulation N.V. Visbeekstraat 24 B - 2300 Turnhout, Belgium Tel: +32 14 44 25 25 Canada, USA, Bermuda, the Cayman Islands, Puerto Rico & St Pierre and Miquelon Kingspan Insulation LLC 2100 Riveredge Parkway, Suite 175, Atlanta, Georgia, 30328, USA Tel: 1 800 227 7339 (for calls within USA only) Tel: +1 (678) 589 7300 (for calls outside of USA) All other countries PAL Middle East PIR LLC P.O. Box 113826, Dubai Investment Park 2, Dubai, U.A.E. Tel: +971 4 889 1000 www.kingspaninsulation.com TM Kingspan, Tarec and the Lion Device are Trademarks of the Kingspan Group plc. Kingspan reserves the right to amend product specifications without prior notice. All information, technical details and fixing instructions etc. included in this literature are given in good faith and apply to uses described. Recommendations for use should be verified as to the suitability and compliance with actual requirements, specifications and any applicable laws and regulations. For other applications or conditions of use, Kingspan offers a free Technical Advisory Service the advice of which should be sought for uses of Kingspan products that are not specifically described herein. Please check that your copy of the literature is current by contacting the Marketing Department. Published May 2015