Test report No

Similar documents
European B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd

Test report No

Test report No

Germany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7

Test report No

Test report No

Test report no

Test report No

Test report no

Test report no

Classification report No K1

Test Report No

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

TEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

Catalogue Partition rooms flexibly. Protect personal privacy. Curtains. Screen Systems

FIRE TEST REPORT FH 5154

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

Report Test Report

MITRAS MATERIALS GMBH

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

Sound-absorbing spacer Sorp10

E/ECE/324/Rev.2/Add.117/Amend.1 E/ECE/TRANS/505/Rev.2/Add.117/Amend.1

Determination Of Fire Effluents From Products On Railway Vehicles

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

EU Mutual Recognition Technical Requirements

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

FIRE REGULATION IN FURNITURE WORLD OVERVIEW

Title: The Fire Resistance Performance of Modified Doorsets. WF Assessment Report No: Prepared for:

National Standard of People s Republic of China

E/ECE/324/Rev.2/Add.106/Rev.6/Amend.5 E/ECE/TRANS/505/Rev.2/Add.106/Rev.6/Amend.5

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces

Title: WF Report No:

The Furniture Retail Quality Group Best Practice Guide

DNVGL-CP-0110 Edition March 2016

FIRE TEST REPORT FH 5728

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Title: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN : Report No: A

Crastin PBT Thermoplastic polyester resins

APIB Test Specification No. 00b General Part B SWISS HAIL IMPACT PROTECTION REGISTER (HSR) / 00b-18en Version 1.02

Ignition Temperatures of R1234yf

13 th December Title: The Fire Resistance Performance Of Doorsets When Fitted With Perko Powermatic R100 Jamb Mounted Concealed Door Closers

DEUTSCHE NORM DIN 8077

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

} Rev.1/Add.52/Rev.2/Amend.2

VAUTH ANALYSING. TESTING. CERTIFYING. aviation components

Test Report Order No _A1 / Part Hessisch Oldendorf. Order: Test of the electrostatic properties of a resilient floor coverings coated

Certifikat och provningsprotokoll för art. 4512, 4513, 4514 och 4515

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Approval of SITEMA Safety Catchers for use as a mechanical restraint device in presses.

Grade A. Evo EV-19 EV-5 EV-4 EV-2 EV-18 EV-14 EV-10 EV-22 EV-20 EV-21 EV-1 EV-23 EV-24 EV-25. Discover more at inscapesolutions.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

20 HUBER+SUHNER RADOX SOLAR

FIRE TEST REPORT FH 5078

NFPA 1951 Standard on Protective Ensembles for Technical Rescue Incidents

Full extension concealed slide with soft closing and self-closing

ETHANOL 1100 FIREPLACE OWNER S MANUAL

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

InnoBYG small scale demonstration tests - Part 1

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg

RECYCLABILITY EVALUATION PROTOCOL FOR PE FILMS

INTERNATIONAL STANDARD

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

Godkjennelsesdokumenter for art. 4509, 4511

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

FLASH POINT TESTER. Instruction Manual. 0. Health and Safety Advice. 1. Introduction

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen

EC type-examination of SITEMA Safety Brakes by DGUV Test

MIRTA-KONTROL d.o.o. LABORATORY DEPARTMENT

PRODUCT EVALUATION REPORT

Test Report /Al (Results with Batch 1) Vastern Timber Company Ltd. Wootton Bassett, Swindon

Excursion 2015 nach Heilbronn

Report Number BTC 12024F

EEA AGREEMENT - ANNEX XIII p. 99 APPENDIX 2 { 1 }

Test Report No

Product Information. Bayferrox 640. Description. Specification. Brown pigment

TEST REPORT. No. 284a/14

Product Information. Bayferrox 610. Description. Specification. Specification. Brown pigment

DEUTSCHE NORM DIN EN 10080

Black pigment - High Performance micronised. Synthetic iron oxide Fe 3 O 4 Pigment black 11 (77499)

LEGAL REQUIREMENTS FOR TRANSPORT AND DISPOSAL OF HAZARDOUS WASTE IN THE ERA OF WASTE CLASSIFICATION

Empty enclosures IEC 62208

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY EU TYPE-APPROVAL CERTIFICATE

BS EN ISO :2006

NFPA 285 TEST REPORT. Report No.: H Test Date: June 1, Rendered to: ARCONIC ARCHITECTURAL PRODUCTS Eastman, Georgia

GROUP WORKING WORKING PAPER. International FIRST MEETING. related tests SUMMARY. 1.1 independent. The DGP also may 1.2. The report, strategies. 1.

Transcription:

Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2015-1661 for applying of a required Verwendbarkeitsnachweis issued 24.07.2015 Applicant: Camira Fabrics Ltd. The Watermill, Wheatley Park, Mirfield West Yorkshire, WF14 8HE Date of order: 24.06.2015 Date of sampling: official sampling of the specimen by a representative of Exova Warringtonfire, Frankfurt Date of arrival: 26.06.2015 Date of test: 21.07.2015 und 22.07.2015 Order Testing of the flammability (building class B1) according to DIN 4102-1 (May 1998) Description / designation of the test object Fabric name: Urban Description of the relevant test procedure DIN 4102 part 1 (Mai 1998) This test report did t replace the required Verwendbarkeitsnachweis. It is only used for issuing the Verwendbarkeitsnachweis.

Test report No. 2015-1661 issued 24.07.2015 page 2 of 8 1. Description of the test material 1.1 Details of the customer: Fabric name: Colour: Composition: Weight: Width: Urban Curb 100% Recycled Polyester 340GSM 140 cm Intended end use of product: Contract Seating 1.2 At the specimen preparation by Exova Warringtonfire, Frankfurt determined values: Fabric sample Colour: Thickness: Square weight: grey 1,02 mm 351 g/m² Testing after storing 14- days under climatic conditions (23 C / 50 % rel. humidity).

Test report No. 2015-1661 issued 24.07.2015 page 3 of 8 2. Test results 2.1.1 Brandschachtprüfung according to DIN 4102-1 Sample A: Sample B: Material tested in production direction Material tested crosswise to the production direction cm Test results of the Brandschacht tests part 1 line Measurements test sample. A B C D 1. test arrangement according to DIN 4102 part 15, table 1 1 1 2 flame height max. over lower sample edge 1 1 time 1) 30 30 3 ascertainments on the front side Flaming/glowing time 1) 9:54 9:56 4 melting / burning through time 1) 0:04 0:04 5 ascertainments on the back side t t Flaming/glowing time 1) 6 discolouring time 1) 7 8 9 10 11 12 burning droplets begin 1) extent occasional dropping of material constant dropping of material separating from burning sample parts begin 1) occasional separating parts constant separating parts 13 duration of burning on the sieve tray (max.) influence on the burner flame by dropping of / separating material 14 time 1) earlier end of test 15 end of the fire scenario on the sample 1) 16 time of a possible resulted test stop 1) t t t t 1) time from start of test

Test report No. 2015-1661 issued 24.07.2015 page 4 of 8 Test results of the Brandschacht tests part 2 line. 17 18 19 20 21 22 23 24 25 26 27 flaming after end of test duration number of sample front side of sample backside of sample flame length glowing after end of test duration number of sample place of occurrence lower sample part upper sample part front side of sample backside of sample cm min. s Measurements test sample A B C D t t 28 29 30 smoke density < 400 % x min > 440 % x min diagram in annex. 10 10 1 1 31 32 33 34 35 36 residual length single results average of the single results photo of the sample on page smoke temperature max. of the average results time 1) diagram in annex. cm cm C 70 / 64 66 / 69 70 / 65 66 / 70 68 67 5 5 125 123 9:43 8:42 1 2 1) time from start of test Remarks: Because of the residual length of > 45 cm, the quantity of tests could be reduced, according to DIN 4102-16.

Test report No. 2015-1661 issued 24.07.2015 page 5 of 8 2.1.2 Appearance of the specimen after the test: Sample A Sample B

Test report No. 2015-1661 issued 24.07.2015 page 6 of 8 2.2.1 Normal flammability test according to DIN 4102-1 Test with edge ignition without deposit Flame application on: lower sample edge Edge ignition Length direction Sample-. Time from start of test 1 2 3 4 5 Ignition point [s] 1 1 1 1 1 Reaching the measuring mark within 20 seconds Self-extinguishing of the flame [s] 5 5 6 6 5 Max. flame height [mm] 50 50 60 60 50 Time [s] 4 4 5 5 4 End of afterflaming [s] - - - - - End of afterglowing [s] - - - - - Flames extinguished after [s] - - - - - Smoke development (visuell impression) low smoke production Separating from burning material Time [s] - - - - - Remarks: ne Cross direction Sample-. Time from start of test 1 2 3 4 5 Ignition point [s] 1 1 1 1 1 Reaching the measuring mark within 20 seconds Self-extinguishing of the flame [s] 6 5 6 6 5 Max. flame height [mm] 50 40 50 50 40 Time [s] 5 4 5 5 4 End of afterflaming [s] - - - - - End of afterglowing [s] - - - - - Flames extinguished after [s] - - - - - Smoke development (visuell impression) low smoke production Separating from burning material Time [s] - - - - - Remarks: ne

Test report No. 2015-1661 issued 24.07.2015 page 7 of 8 2.2.2 Appearance of the sample after the small burner test:

Test report No. 2015-1661 issued 24.07.2015 page 8 of 8 Assessment The material, described in chapter one fulfils the requirements of the building class B2 according to DIN 4102-1 (Mai 1998). The determined test results show that the material also fulfils the requirements according to DIN 4102-1 (Mai 1998). of the building class B1 Special comment The fire test result is only valid for the in chapter one described material in the tested colour and square weight. The test was carried out in free hanging configuration. The distance to other plane material must be more or equal then 40 mm. The material wasn't tested after an outside storage. In combination with other materials (for example coatings, deposits) the burning behaviour could be influenced unfavourable so that the classification above is t valid any longer. According to DIN 4102-1 the burning behaviour in combination with other materials has to be tested separately. This test report did t replace the required Verwendbarkeitsnachweis. It is only used for issuing the Verwendbarkeitsnachweis. Frankfurt, the 24.07.2015 H. Anders Dipl.-Ing. T. Zachäus Tester in Charge Laboratory supervisor This Test report is valid until 21.07.2020 The results of the tests relate only to the behaviour of the test specimen which is designated on the top. Test reports are only allowed to be published or reproduced, t changed in form and ter without permission of the Exova Warringtonfire, Frankfurt. The abridged account of a test report is only allowed with the agreement of the Exova Warringtonfire, Frankfurt. This test report is a translation of the German version 2015-1661 (issued 24.07.2015). In case of doubt only the German version is valid This test report contains 8 pages and 2 annexes..

Annex 1 to the Test report No. 2015-1661 issued 24.07.2015 Sample A:

Annex 2 to the Test report No. 2015-1661 issued 24.07.2015 Sample B: