Key-Words : Eddy Current Testing, Garter Spring, Coolant Channels, Eddy Current Test Coil Design etc.

Similar documents
ESTABLISHMENT OF ULTRASONIC TESTING IN UNIQUE DESIGNED PARTIAL PENETRATION END PLUG OF HEADER IN BOILERS.

1: CANDU Reactor. B. Rouben McMaster University Nuclear Reactor Physics EP 4D03/6D Sept-Dec September 1

INSPECTION TECHNIQUE FOR BWR CORE SPRAY THERMAL SLEEVE WELD

A Practical Guide to Free Energy Devices

Primary Heat Transport (PHT) Motor Rotor Retaining Ring Failure

CONSIDERATIONS REGARDING THE HORIZONTAL FUEL CHANNELS IN THE CANDU 6 NUCLEAR REACTOR. PART 1 - PRESENTATION OF THE FUEL CHANNEL

Cooling Enhancement of Electric Motors

Defect Monitoring In Railway Wheel and Axle

Computer-Assisted Induction Aluminum

Module 09 Heavy Water Moderated and Cooled Reactors (CANDU)

ED-400 PORTABLE EDDY CURRENT UNIT

IMPACT OF SKIN EFFECT FOR THE DESIGN OF A SQUIRREL CAGE INDUCTION MOTOR ON ITS STARTING PERFORMANCES

Design, Development and Testing of a Large Capacity Annular Linear Induction Pump

Sub:EE6604/DESIGN OF ELECTRICAL MACHINES Unit V SYNCHRONOUS MACHINES. 2. What are the two type of poles used in salient pole machines?

En-Masse Coolant Channel Replacement in Indian PHWR

Input, Control and Processing elements

Electromagnetic Forming and Joining for Automotive Applications

INDUCTANCE FM CHAPTER 6

Stray Losses in Power Transformers

CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS

CONSIDERATIONS FOR THE DEVELOPMENT OF A DEVICE FOR THE DECOMMISSIONING OF THE FUEL CHANNELS IN THE CANDU NUCLEAR REACTOR

EXAMINATION OF NOZZLE INNER RADIUS AND PIPING FROM THE OUTER SURFACE

LECTURE 27 SERVO VALVES FREQUENTLY ASKED QUESTIONS

PROF. UNIV. EMERIT DR. ING.

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS

CIRCOGRAPH Sensor systems Rotating Head Ro 35 P Rotating Head Ro 35 L

ELECTROMAGNETIC INDUCTION. Faraday s Law Lenz s Law Generators Transformers Cell Phones

ITER Shield Blanket Design Activities At SWIP

Electromagnetic Field Analysis for Permanent Magnet Retarder by Finite Element Method

International Journal of Computer Engineering and Applications, Volume XII, Special Issue, March 18, ISSN

CHAPTER 8: ELECTROMAGNETISM

MEASURING INSTRUMENTS. Basic Electrical Engineering (REE-101) 1

Page 1. Design meeting 18/03/2008. By Mohamed KOUJILI

Transient analysis of a new outer-rotor permanent-magnet brushless DC drive using circuit-field-torque coupled timestepping finite-element method

INTRODUCTION Principle

POWER RAMPING AND CYCLING TESTING OF VVER FUEL RODS IN THE MIR REACTOR

Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

DISSECTIBLE TRANSFORMER - large

A STUDY OF A MULTI-STEP POLE TYPE ELECTRO-MAGNETIC ACTUATOR FOR CONTROLLING PROPORTIONAL HYDRAULIC VALVE

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR

Basic Instruments Introduction Classification of instruments Operating principles Essential features of measuring

CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS

TRAINSAFE SAFE INFRASTRUCTURE WORKSHOP DEMONSTRATION OF THE RESEARCH CLUSTER MECHANISM FOR INSPECTION TECHNOLOGIES

CHAPTER 13 MAGNETIC EFFECTS OF ELECTRIC CURRENT

Cooldown Measurements in a Standing Wave Thermoacoustic Refrigerator

Induction type Energy meter Construction

ELECTRO MAGNETIC INDUCTION

CHAPTER 7 CONCLUSION

PowerCORE 8.8mm Hybrid Super Conducting Wire CORETECH OVERVIEW

Inductive Power Supply (IPS ) for the Transrapid

FRM II Converter Facility

Extreme Environment For high pressure, low temperature, and high temperature applications

CFD ANALYSIS ON LOUVERED FIN

4. Sensors and Switches

Induction Coil Design and Theory. United Induction Heating Machine Limited.

Safe, fast HV circuit breaker testing with DualGround technology

Development of a low voltage Dielectric Electro-Active Polymer actuator

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

EMaSM. Principles Of Sensors & transducers

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

Design, Fabrication and Testing of helical tube in tube coil heat exachanger

High Performance Machine Design Considerations

To study the constructional features of ammeter, voltmeter, wattmeter and energymeter.

General Purpose Permanent Magnet Motor Drive without Speed and Position Sensor

ELECTROMAGNETIC INDUCTION. FARADAY'S LAW

Post Irradiation Examinations of High Performance Research Reactor Fuels

1. INTRODUCTION XA SLIGHTLY ENRICHED URANIUM FUEL FOR A PHWR

Comparison of Bruce A, Bruce Band Darlington

Electromagnetic Fuel Saver for EnhanchingThe Performance of The Diesel Engine

Electromechanical Gyroscope-Accelerometer (invention)

Visual Inspection of Reactor Vessel Head Penetration Nozzles

Design and dimensions calculation of Inductive Rheostat as a Control Element of Synchronization Systems

Detection and evaluation of rail defects with nondestructive

Fachpraktikum Elektrische Maschinen. Theory of Induction Machines

ULTRASONIC EXAMINATION

Chapter 31. Faraday s Law

Re evaluation of Maximum Fuel Temperature

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

Study on Flow Fields in Variable Area Nozzles for Radial Turbines

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL ELECTRICAL MACHINES

Application Note. Monitoring Bearing Temperature with ProPAC

A Practical Guide to Free Energy Devices

Instrumental technique presentation

Performance Monitoring of Zircaloy-4 Square Fuel Channels at Taps - 1&2 / NPCIL

VARIABLE SPEED DRIVES AND MOTORS

WEAPONX CIRCUIT COMPRESSION

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

LION. Application Note LA November, 2015 PRECISION. Using Eddy-Current Sensors For Thread Detection

ULTRASONIC TESTING OF RAILWAY AXLES WITH PHASED ARRAY TECHNIQUE EXPERIENCES DURING OPERATION

SVE135 Sealed High-Voltage Contactor Having High Overcurrent Withstand Capability

A Novel Technique for Energy & Cost Effective Drives for AC & DC Motors

Fuel cladding stress evaluation for the control rods pattern change at the Shimane Nuclear Power Station Unit No1 and No2

CURRENT ELECTRICITY - II

2006 MINI Cooper S GENINFO Starting - Overview - MINI

Design Study for Passive Shutdown System of the PGSFR

NOVATEUR PUBLICATIONS INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT] VOLUME 1, ISSUE 1 NOV-2014

Gauges, Sight Glasses and Vacuum Breakers

Part- A Objective Questions (10X1=10 Marks)

Transcription:

More Info at Open Access Database www.ndt.net/?id=15054 Development of Eddy Current Test Technique for Detection of Garter Springs in 540 and 700 MWe Pressurized Heavy Water Reactors Arbind Kumar AFD, BARC, Trombay, Mumbai 400 085 e-mail : arbindk@barc.gov.in Abstract Pressurized Heavy Water Reactor (PHWR) is a pressure tube type power reactor. Two types of PHWRs viz. 235 Mwe and 540 Mwe are operating in India. 700 MWe (4 nos.) PHWRs are under construction. There are 306 coolant channels in 235 Mwe PHWRs and 392 coolant channels in 540 and 700 MWe PHWRs. In Coolant Channels, the gap between pressure tube and concentric calandria tube is maintained using four tight fit garter springs rested on the outer surface of the pressure tube. Eddy Current Testing is used for detection of garter spring in coolant channels of 235 Mwe PHWRs. The garter spring consists of a helical coil of rectangular wire and a girdle wire inserted inside the helical coil. The girdle wire is welded in 235 Mwe PHWRs. During service, diameter of pressure tubes increases and it may lead to either creation of depression on the outer surface of the pressure tube or breakage of welded girdle wire. To overcome this difficulty, overlapped girdle wire was used in 540 Mwe PHWRs. The girdle wire is provided for easy detection of garter spring using eddy current testing. In welded condition, it supports during detection of garter spring by eddy current testing but in overlapped condition, its contribution towards garter spring detection is not so effective. During service, the detection of garter spring is more difficult in 540 Mwe PHWR as the girdle wire get oxidized which leads to non-contact between its overlapped ends. To overcome the difficulties faced due to welded or overlapped girdle wire of garter spring, it is proposed to use centrally corrugated and tip spot welded girdle wire in 700 MWe PHWRs. Eddy Current test coil was designed and eddy current test procedure was developed for detection of 540 Mwe PHWRs at Tarapur Atomic Power Station (TAPS-3&4). The test procedure was also standardized for detection of garter springs in 700 MWe PHWRS. The sensitive test coil was designed and the test parameters were standardized for detection of garter spring. The design of eddy current test coil, standardization of eddy current test parameters and eddy current test signal analysis will be discussed in this paper. Key-Words : Eddy Current Testing, Garter Spring, Coolant Channels, Eddy Current Test Coil Design etc. 1.0 Introduction There are three stages nuclear power program in India. Pressurized Heavy Water Reactor (PHWR) belongs to first stage. The schematic of pressurised heavy water reactor is shown in figure 1. Two types of PHWRs viz. 235 Mwe and 540 Mwe are operating in India. The construction of 700 MWe PHWR is in progress. There are 306 coolant channels in 235 Mwe PHWRs and 392 coolant channels in 540 MWe and 700 MWe PHWRs [1]. In Coolant Channels, the gap between pressure tube and concentric calandria tube is maintained using 4 numbers of tight fit garter springs rested on the outer surface of the pressure tube. The materials for pressure tube, calandria tube and garter spring are Zr-2.5%Nb, Zr-2 and Zr-2.5%Nb-0.5%Cu respectively. The pressure tube is having 103.4 mm internal diameter, 4.3 mm wall thickness and 6.3 meter length. The pressure tube is connected with the end fitting using Zero Clearance Rolled Joint.

Natural uranium oxide is used as fuel in PHWR. There are 19 elements fuel bundles and 37 elements fuel bundles in 235 Mwe and 540 Mwe PHWRS respectively. Heavy water (D 2 O) is used as coolant and moderator. High temperature (300C) and high pressure (1500 psi) heavy water coolant flows around the fuel elements present in the pressure tube. Heavy Water moderator, surrounded the calandia tube of coolant channels, is at low temperature (70C) inside the calandria vessel. Due to flow induced vibration, garter springs may shift from their design location. Due to irradiation creep, diameter of the pressure increases and the garter springs get strained. This strained condition may unhook the garter spring. It may leads to dislodge of welded joint on the girdle wire. The pressure tube sags easily in such condition. Under strained condition, if girdle wire does not dislodge at welded position, the garter spring will create local impression on the pressure tube outer surface. These conditions will be unfavourable for the integrity of the pressure tube. Eddy current testing is used for detection of garter spring in coolant channels of pressurized heavy water reactors [2]. In 235 Mwe PHWR, the girdle wire is welded whereas in 540 Mwe PHWR, the girdle wire is overlapped. The welded girdle wire helps in getting the eddy current test signal from garter spring. The overlapped girdle wire gets oxidized during service. Hence the signal observed from such garter spring is very weak. To overcome this problem, new differential bobbin probe was designed and eddy current test parameters were standardized for detection of garter spring at TAPS 3&4. During detection of garter spring, some unwanted eddy current test signal was observed during in-service inspection of TAPS 3&4. This signal was observed at regular interval which may be due the constriction in pressure tube at the end of the fuel bundle. This signal can be differentiated from the signal from the garter spring. For 700 MWe PHWR, the design of girdle wire in garter spring will be corrugated and welded. Two-third of the central portion of the girdle wire will be corrugated and one third near the both end of the girdle wire will be in plain and un-corrugated condition. At the tip of the girdle wire, two spot welds will be provided at 10 mm span. Eddy Current Test Coil was designed and fabricated and test parameters were standardised for detection of garter spring containing the corrugated and welded wire. The design of eddy current test coil, standardization of eddy current test parameters and analysis of EC signal will be discussed in this paper.

Garter Spring Fig. 1 : Schematic of Pressurised Heavy Water Reactor 2.0 Principle of Eddy Current Testing Eddy current testing is based on the principle of electromagnetic induction. When a coil carrying alternating current is passed through the tubes, the changing primary magnetic field associated with the alternating current flowing through the coil induces the eddy current in the tube. The eddy current flows parallel to the coil winding in the tube and opposite in direction to that of primary current in the coil. The secondary magnetic field associated with the eddy current opposes the primary magnetic field and the impedance of the coil differs to that of the empty coil impedance. This change in impedance is visualized on the CRT screen in terms of voltage. Tube conditions govern the flow path of eddy current and changes the amplitude as well as the phase of the signal. There are many variables that affect the eddy current flow path but generally the signal responses from the different variables are different. Selection of the test parameters is extremely important in eddy current testing. Eddy current density decreases exponentially from the surface to the inside of the tube. This limits the tube wall thickness which can be tested by eddy current testing. Standard depth of penetration, the distance from the surface at which eddy current density is 37% of surface current density, depends on the test frequency as well as test object variables such as electrical conductivity and permeability. Once the tube is supplied for testing, the tube properties such as electrical conductivity and permeability are fixed. Frequency is the only variable that can be varied to meet the desired depth of penetration as well as sensitivity. Depth of penetration decreases and sensitivity increases as the frequency increases. 3.0 Test Parameters Selection Three parameters such as frequency, phase and gain are to be selected for testing of the test object by eddy current testing. Frequency decides the depth of penetration of eddy current in the tube, the sensing volume of the material as well as the sensitivity of the flaw detection. Garter spring is rested outside the pressure tube. For detection of garter spring, 7 khz frequency was selected. At 7KHz frequency, the depth of penetration is more than the tube wall thickness. The magnetic field can emerge out of the pressure tube and interact with the garter spring. The separation of signals on the basis of phase was also better. Phase was selected to set the garter

spring signal in vertical direction. Gain was selected to get the appreciable signal from the garter spring. 4.0 Test Coil Design Eddy Current test coil is one of the important elements of eddy current test system. Test coil carries alternating current and induces eddy current in test tube with the help of changing magnetic field across it. Self-comparison type differential bobbin coil was designed, fabricated and used during detection of garter spring. Differential coils compare nearby zone around the coils and hence it is the most suitable coil for detection of garter spring. Garter springs are located at outside the pressure tube and they need to be detected by insertion of inspection coil through the pressure tube. On this basis, bobbin shape of the coil was selected. Single impedance coil of 7 Khz central frequency was used for generation and detection of eddy current signal. Number of turns and diameter of the copper wires, coil depth and coil length were selected to match the impedance of the equipment and coil Q-factor (ratio of inductive reactance to resistance) of 10. Coil was winded in groove a in one direction and in groove b in opposite direction. Gap between the coils was selected comparable to garter spring diameter. Depth and width of the groove and the gap between the grooves was selected to ensure accommodation of number of wires required to match the equipment impedance and to produce the required central frequency. The details of the differential bobbin coil are shown as below in Fig. 2. a b Fig. 2 : Differential Bobbin Coil 5.0 Eddy Current Test Signal Analysis Inspection Head containing differential bobbin coil for garter spring detection is calibrated in the mock-up coolant channel. Test frequency used during calibration is 7KHz. Gain was adjusted to get appreciable signal from garter spring. The garter spring signal is set in vertical direction. Eddy Current test signals observed from garter springs are recorded. The calibrated inspection head is inserted through the defueled pressure tube using remotely operated drive mechanism. Eddy current test signals are recorded during the retraction of inspection head inside the pressure tube. Garter springs were located at is design location. During inspection, some eddy current test signals are observed whose characteristics are not matching with the signal from garter spring. These signals are observed from the change in properties of the pressure tube at the end of fuel bundles. The signals observed from garter spring and the change in pressure tube properties are shown in figure 3.

ECT Signal from Garter Spring ECT Signal from Pressure Tube Fig. 3 : Eddy Current Test Signal (ECT) Signal observed from garter spring and change in material properties of pressure tube. 6.0 Experience during Detection of Garter Spring at TAPS 3&4 The garter spring in 540 MWe PHWRs contains overlapped girdle wire. The eddy current test signals observed from the garter spring calibration set-up and garter springs in coolant channel of TAPS 3&4 observed during in-service inspection are shown in Fig. 4a and 4b respectively. a b GS1 GS2 GS3 GS4 Fig. 4 Eddy Current Test Signal from (a) Garter Spring Calibration Set-up (b) 4 Nos. of Garter Springs in Coolant Channel of TAPS 3 7.0 EC Signal observed from Garter Springs for 700 Mwe To overcome the difficulty faced during garter springs in 540 Mwe PHWR Coolant channels, it is proposed that the girdle wire in garter spring of 700 Mwe PHWRs shall be corrugated and welded. The corrugated region will expand as the diameter of the pressure tube will increase due to irradiation creep. The tips of the girdle wire will be welded to ensure better detectability of these garter springs using eddy current testing. Eddy current testing was carried out in author s laboratory to detect both garter springs for 540 Mwe as well as 700 Mwe PHWRs. Differential bobbin coil with 7 Khz central frequency was designed and fabricated. ECT signals were recorded for both the garter springs. ECT signals recorded with garter springs (overlapped girdle wire without welding) for 540 Mwe PHWRs is shown in figure 5. It shows the EC Signals from garter spring, as shown in figure 5a, is of smaller amplitude as compared to ECT signals recorded with garter springs (corrugated girdle wire with welding) for 700 Mwe PHWRs as shown in figure 5b. It shows the EC Signals from garter springin 700 Mwe is of appreciably higher amplitude than that of EC Signals from GS Signal from 540 Mwe PHWRs.

5a 5b Fig. 5 : EC Signals from Garter Springs for (a) 540 Mwe and (b) 700 Mwe 8.0 Conclusions Coolant Channel is one of the most critical components of the pressurised heavy water reactors. Garter springs maintain the gap between pressure tube and calandria tube in coolant channels. Shifting of garter springs from design location limits the life of coolant channels. Detection of location of garter springs in coolant channel is an important activity during in-service inspection of coolant channels. Eddy current testing is utilised for detection of garter spring using differential bobbin coil. In 540 Mwe pressurised heavy water, the girdle wire in garter spring is overlapped. Eddy current test coil with sufficient sensitivity and eddy current test equipment with sufficient amplification facility were used during in-service inspection of coolant channels of TAPS 3&4 and all the four garter springs were detected in all the coolant channels required to be inspected during shutdown. EC signals from garter spring containing corrugated and welded girdle wire is having higher amplitude than that of garter spring containing overlapped without welded girdle wire. Hence detectability will be better for garter spring containing corrugated and welded girdle as compared to garter springs containing overlapped without welded girdle wire. References : 1. Design of Eddy Current Test Coils for In-Service Inspection of Pressurised Heavy Water Reactor Coolant Channels, Arbind Kumar et.al., Proc. Of ISNT Seminar NDE-2008 at Lonavala. 2. Development in Non-Destructive Evaluation of Fuel Channels Dolbey M. P. et. Al., Ontario Hydro Research Review, August 1993.