Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one side permits mounting in three directions. Space-saving 45% less Capacity-saving 5% less Regulator unit ocking type (Manual) ocking type manual override Blanking plate assembly Ejector unit VQ (VV5Q5) Unprecedented high speed response and long service life (Metal seal, single, with indicator light/surge voltage suppressor) VQ VQ2 1 ms 1 ms 2 ms 2 million cycles Dispersion accuracy ±2 ms Thin compact design with large flow capacity Model VQ VQ2 Manifold pitch (mm) 1.7 1.5 16 Flow characteristics Metal seal Rubber seal Cylinder size C [dm 3 /(s bar)] C [dm 3 /(s bar)].44.72 2.6 Flow characteristics: 4/2 5/3 (A/B R1/R2).53 1. 3.2 Up to ø4 Up to ø5 Up to ø8 VQ DIN rail Dual flow fitting Elbow fitting assembly (Top entry connector) Elbow fitting assembly (Bottom entry connector) The photo does not show an actual use example. A variety of options Port plug Individual EXH spacer (VV5Q11) Individual SUP spacer VQ2 (VV5Q21) Innovative mounting methods The non-bias, one-clamp structure permits easy valve replacement. (Plug-in unit) A variety of common wiring methods are standardized. F P J (D-sub connector) Number of pins: 15, 25 (Flat ribbon cable connector) Number of pins: 1, 16, 2, 26 (Flat ribbon cable connector) Number of pins: 2 (PC Wiring System compliant) Built-in One-touch fittings for easy piping. Top entry Side entry Top entry Side entry Top entry Side entry (Flat ribbon cable (Terminal box) (ead wire) (Serial transmission (Multi-connector ) with terminal block) unit) Number of pins: 2 G T S M (VQ2 only) 2-4-113
Valve Specifications Sonic conductance C [dm 3 /(s bar)] 4/2 5/3 (A/B R1/R2) Double Single 3 position Closed center Single Type of actuation Voltage Electrical entry Manual override Double Closed center Exhaust center Pressure center 12 V1 V 2 V 24 V11 V 22 V DC AC AC 5/6 5/6 Hz Hz Plug-in Grommet plug connector M plug connector Push type, Tool required ocking type ocking type (Manual) Rubber seal VQ.72.72 Base Mounted Plug lead Plug-in P. 2-4-12 VQ2 P. 2-4-124 VQ P. 2-4-182 Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal VQ1 1 VQ2 VQ2 1 VQ 5 VQ 51 VQ1 1 1. 2.6 3.2.44.53.72.65 2. 2.2.32.44.72 (F/ only) P. 2-4-128 (F/ only) P. 2-4-128 P. 2-4-186 Metal seal VQ1 11 1..65 P. 2-4-184 P. 2-4-186 2-4-114
P. 2-4-215 P. 2-4-215 For S, please contact SMC. For S, please contact SMC. For S, G, please contact SMC. For S, G, please contact SMC. Except Except Except Standard P. 2-4-177 P. 2-4-172 P. 2-4-28 P. 2-4-21 P. 2-4-177 P. 2-4-166 Except External pilot D-sub connector 15P Flat ribbon cable 1P 16P 2P Negative common specifications One-touch fitting Inch size For special wiring spec. Blanking plate Individual SUP/EXH SUP/EXH passage spacer Name plate Back pressure check valve DIN rail mounting style Built-in silencer Silencer for EXH port Elbow fitting for cylinder port Two stations matching fittings for double flow rate Plug for cylinder port Regulator unit Ejector unit mounted Double check block Option Manifold Option 2-4-115 VQ
VQ/Base Mounted: Variations Manifold Variations F P J G D-sub connector Conforming to MI D-sub connector Flat ribbon cable connector (26, 2, 16, 1 pins) Conforming to MI flat ribbon cable connector Flat ribbon cable connector (2 pins) Conforming to MI flat ribbon cable connector PC Wiring System compatible Flat ribbon cable with power supply terminal block Conforming to MI flat ribbon cable connector Applicable to OMRON s serial transmission unit PC Wiring System compatible Plug-in VQ2 P. 2-4-13 P/J P. 2-4-134 P. 2-4-142 P. 2-4-13 P/J P. 2-4-134 P. 2-4-142 VQ Plug ead P. 2-4-188 P only P. 2-4-192 P. 2-4-188 P only P. 2-4-192 P. XXX 2-4-116
T Manifold Variations C S M Terminal block box (Terminal block) Terminal blocks are compactly arranged on one side. ead wire Direct electrical entry type Serial transmission unit Enables single-wire solenoid valve-pc operation Circular connector IP65 (Dusttight/ow jetproof type) VQ Terminal block box P. 2-4-146 P. 2-4-15 P. 2-4-154 Enclosure IP65 compliant Enclosure IP65 compliant Enclosure IP65 compliant P. 2-4-146 P. 2-4-15 P. 2-4-154 W type only P. 2-4-158 C Terminal block P. 2-4-196 P. 2-4-2 P. 2-4-24 C Terminal block P. 2-4-196 P. 2-4-2 P. 2-4-24 2-4-117
Cylinder Speed Chart VQ151 Port size: One-touch fitting for ø4 VQ111 Port size: One-touch fitting for ø6 VQ211 Port size: One-touch fitting for ø8 Average speed (mm/s) 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 CJ2 Pressure.5 MPa oad factor 5% Stroke 6 mm CM2 Pressure.5 MPa oad factor 5% Stroke 3 mm Bore size Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program. MB, CA1 Pressure.5 MPa oad factor 5% Stroke 5 mm ø6 ø1 ø16 ø2 ø25 ø32 ø4 ø4 ø5 ø63 ø8 ø1 Perpendicular, upward actuation Horizontal actuation VQ It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. oad factor: ((oad weight x 9.8)/Theoretical force) x 1% Conditions VQ151 VQ111 VQ211 Conditions Tube bore x ength Speed controller Silencer Tube bore x ength Speed controller Silencer Tube bore x ength Speed controller Silencer CJ2 CM2 MB, CA1 T425 x 1 m AS21F-4 AN13-X233 T64 x 1 m AS31F-6 AN13-X233 T86 x 1 m AS31F-8 AN2-KM8 2-4-119
Plug-in Unit Base Mounted How to Order Valves VQ 1 1 Y 5 1 Type of actuation 1 2 3 4 5 T 2 position single Metal Rubber 2 position double 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 4 position dual 3 port valve Note) (A) 4 2 A 5 3 N.C 1 N.C 4 position dual 3 port valve Note) (B) 4 2 B 5 3 N.O 1 N.O 4 position dual 3 port valve Note) (C) 4 2 C 5 3 N.C 1 N.O (Terminal box) Seal 1 Metal seal Rubber seal Function Symbol Specifications Nil Standard type H Y High pressure type ow wattage type Note) For power consumption of AC type, refer to page 2-4-129. Note) For external pilot and negative COM specifications, refer to Option on pages 2-4-178 to 2-4-179. Note) Rubber seal type only. (ead wire cable) Manual override Nil: Non-locking B: Push-locking push type slotted type (Tool required) C: ocking type ight/surge (Manual) voltage suppressor Nil Yes Note) E None Note) Inapplicable to the S. Coil voltage 1 1 VAC (5/6 Hz) DC AC Note) 2 2 VAC (5/6 Hz) (1. W) Note) 3 11 VAC (5/6 Hz) Note) 4 22 VAC (5/6 Hz) (1.5 W) 5 24 VDC 6 12 VDC (.5 W) Note) 2/22 VAC models are applicable to F and s. How to Order Manifold Assembly Example Single solenoid (24 VDC) VQ11-5 (4 sets) D-sub connector F (D-sub connector) S (Serial transmission unit) D side U side 1 2 3 Stations Double solenoid (24 VDC) VQ12-5 (4 sets) Blanking plate -1A-1 (1 set) Cylinder ports C6: With One-touch fitting for ø6 Manifold base (9 stations) VV5Q11-9C6FU2 VV5Q11-9C6FU2 1 set (F 9 station manifold base no.) VQ11-5 4 sets (Single solenoid part no.) VQ12-5 4 sets (Double solenoid part no.) VV1-1A-1 1 set (Blanking plate part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Specify the part numbers for valves and options together beneath the manifold base part number. Besides, when the arrangement will be complicated, specify them by means of the manifold specification sheet. The valve is equipped with an indicator light and surge voltage suppressor, and the voltage is 24 VDC. The dust proof SI unit is also available. Refer to page 2-4-154 for details. P. 2-4-154 VQ P. 2-4-146 Kit T O Terminal block box 2 to 24 stations (2) Kit 1 2 With cable (.6 m) With cable (1.5 m) With cable (3 m) P. 2-4-15 1 to 8 stations Kit S A Mitsubishi Electric Corp.: B MESECNET/MINI-S3 Data ink System C OMRON Corp.: SYSBUS Wire System D SHARP Corp.: Satellite I/O ink System E Matsushita Electric Works: MEWNET-F System F1 NKE Corp.: Uni-wire System (16 output points) G Rockwell Automation: Allen Bradley Remote I/O (RIO) System H NKE Corp.: Uni-wire H System J1 SUNX Corp.: S-INK System (16 output points) J2 SUNX Corp.: S-INK System (8 output points) K Fuji Electric Co.: T-INK Mini System Q DeviceNet, CompoBus/D (OMRON Corp.) R1 OMRON Corp.: CompoBus/S System (16 output points) R2 V Without SI unit With general type SI unit ( EX3) OMRON Corp.: CompoBus/S System (8 output points) Mitsubishi Electric Corp.: CC-INK System (2) Max.16 stations Max. 8 stations Max.16 stations Max. 8 stations Max. 16 stations 2-4-121
Base Mounted Manifold Option P. 2-4-28 Blanking plate assembly V-1A-1 SUP block plate V-16A Double check block -FPG- 2 stations matching fitting assembly V-52A-C8 Blanking plug 23 4 KQ2P- 6 8 To CY port Individual SUP spacer V-P-1-C6 EXH block base assembly F C3 V-19A- P C4 - C6 M5 Elbow fitting assembly V-F- C3 C4 C6 M5 Silencer (For EXH port) AN2-KM8/AN23-KM8 Blanking plate with connector V-1C - C6 (SUP port) One-touch fitting for ø6 Connector assembly Individual EXH spacer V-R-1-C6 C6 (EXH port) One-touch fitting for ø6 Back pressure check valve assembly [-B] DIN rail mounting bracket [-D] V-18A V-57A Regulator unit V-AR-1 For cylinder port fittings part no., refer to page 2-4- 175. For replacement parts, refer to page 2-4-227. With vacuum ejector unit [-J ] Name plate [-N] Built-in silencer, V- N NC -Station (1 to Max. stations) direct exhaust [-S] Exhaust port Port plug VVQ-58A 2-4-122