SPEEDROLLER SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL. Edition : May 2011

Similar documents
SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

High performance door Albany RR300. ASSA ABLOY Entrance Systems

High performance door Albany RR300. ASSA ABLOY Entrance Systems

Northern Sales & Distribution Centre

Door Automation. Kwikroll high speed doors. Vehicle flow solutions

High-performance door Albany RR500. ASSA ABLOY Entrance Systems

High Speed Doors Cost effective and energy efficient

HIGH SPEED DOORS roll-up folding

User manual Pipe notcher Type: AL 1-2E

WEEK DELIVERY. High-Speed Doors. For optimised material flow and improved efficiency. Made in Germany

RapidRoll 330. Data Sheet High Performance Door. Hand in hand speed, safety and appearance

High speed doors. Fast logistic solutions

Fast logistic solutions

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Automatic concealed bollards 275 H600 and 275 H800 with pit

Albany RapidRoll 3000 Series The high performance doors for external and internal applications for the manufacturing industry. Technical data sheet

NR LOGBOOK & USER MANUAL FOR MAINTENANCE AND USE OF THE. Compact Industrial Doors RED BOOK

ZB0050 / ZB0051 ZB0070 / ZB0071

TECHNICAL DATA HYDRAULIC UNIT

Sense7-series Non-contact coded safety switch

Assembly instructions PRORUNNER mk1 2

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Slide gate openers MOVEMENT BRINGS MORE

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

THE HYBRID RIGID HIGH SPEED ROLL UP DOORS

6L Oil-less Air Compressor 53103

INSTRUCTION MANUAL. Battery powered crimping tool SMART-LINE. Battery powered crimping tool SO-6M. Art /M. convincing solutions.

SWING GATE OPENERS 24V DC GEAR MOTOR

Delta Secure Spiroll 40 High Speed Security Door. Product Data Sheet 4 / 7

2006/42/EG, DIN EN ISO 12100, DIN EN

ISO sectional overhead doors. A product of ALPHA Deuren International BV

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

Assembly and Operating Instructions

ELEKTROMATEN ST Sliding-door-drive

NovoSpeed Solutions. Fast logistic solutions

Support T10552 T10595 T40386

DON T FORGET ABOUT YOUR OVERHEAD DOORS

Battary powered cutting tool. AS6-S32 Art convincing solutions. Video

Installation Manual Sectional door with rear springs (LF 70) Conform TÜV / CE EN

Tina 10A/B/C Adaptor unit

Operating instructions ErgoPack 600 E

High Performance Door Albany RP300. ASSA ABLOY Entrance Systems

Product datasheet High speed door Albany HS9010PFR. ASSA ABLOY Entrance Systems

Instructions for: FOLDING ENGINE CRANE PREMIER 2 TONNE. MODEL No: SPC2000

Operating instructions

High Speed doors Break through Self Repairing PAT AR & Rekord series

User Manual. Studio Rail. Size Version

Battery powered cutting tool. AS6ST-20 Art convincing solutions. Video

242 Overhead sectional doors

Machine protection doors. MS series

Operating Instructions for Roll-Up Door Operators / MDF

Max. stand-by power without accessories Use frequency 100% Max leaf width Motor Motor powered at 36V with encoder Max.

FMC-1/2 Tina Muting unit

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Automatic concealed bollards 275 H600 and 275 H800 Control station

maviroll A highly efficient roll-door solution for internal applications Beyond doors, a concept!

Safety and Technology for medium to large entrances. Traffic - Energy ENG. High-speed folding doors

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

CE Operating and Maintenance Manual

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

APOLLO Gate Operators, Inc.

E10 ECOVimec electrical Lifting Platform Technical Data

5030 MSL SAFETY LIGHT GRILLE

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

METAL DETECTOR AND REJECTION SYSTEM FOR PIPELINE APPLICATIONS

Installation Instructions

Technical Documentation

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Parking space border or support. Drive axis 15 L

Peristaltic Cased Tube Pumps

HST-BL-2830MS & HST-BL-2830MS-USA

muck-truck It doesn t cost the earth to move it! OWNERS & OPERATIONS INSTRUCTION MANUAL

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

Model 1550 Single Swing Gate Model 1650 Dual Swing Gate

Rotary Limit Switches Driver FRS Series

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

H-1274 OR-T 200. Battery-hand tool for plastic strapping. Before using the tool, read the operating instructions carefully. 08/07

Electro-hydraulic crimping tools SD300-6M / SD400-6M. Art /M / /M. convincing solutions. Video /M Video /M

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

CAUTION CM-SE CM-S21 CM-S41

NEW Standard safety light grille SAFETY LIGHT GRILLE. as standard. High-Speed Doors. For optimised material flow and improved efficiency

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Copyright Qimarox B.V.

ABB Switzerland Ltd Phone Surge arresters Telefax:

Parking space border or support. Drive axis 15 L

Shock/Vibration Control Switches

Electrical operating instructions

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

USER'S GUIDE and Spare Parts Drawings GENERIC APPLICATIONS

Safety instructions. Always... Never... Fire hazard! Dear customer,

AEROSTAT HP-N-Ex Ionising Air Blower

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

Mechanical Operating Instructions

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Transcription:

SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL SPEEDROLLER Edition : May 2011

1 8 2 3 4 Main components 1 drive 2 wind roller with hood (optional) 3 door panel 4 aluminium hinge profile 5 window section 6 bottom beam 7 side guide with brush guide 8 control box 9 spiral cable 10 photocell 11 reflector 12 CE plug 12 5 7 9 11 10 6

Contents page Read this first! 2 Improper use 2 Warranty terms 2 Product description 3 Operation and use 4 Faults 5 Maintenance 6 EU Certificate of Conformity / installation company s certificate 7 Delivery checklist 8 Work performed 9-12 Annexes Exploded drawing / parts list Order specifications Electrical diagram(s) Installation guide SPEEDROLLER 1

Read this first! Read through the whole user manual before using the product. An electrically-driven door may only be used after it has been issued with a Certificate of Conformity. This manual describes the use of a door that has been installed and configured by an authorised dealer or a suitably qualified engineer. It is intended for the day-to-day user of the door and must be kept in the immediate vicinity of the door. Instruct users how to operate the door. Do not allow third parties (e.g. visitors) to operate the door. This product has been designed and manufactured in accordance with the ISO 9001 quality system. The manufacturer accepts no liability for damage and/or injury caused by failing to follow the instructions in this manual. Have the door repaired, maintained and removed by qualified engineers only. The type plate contains information you will need when you contact your dealer (it can be found on one of the side guides and on the control box). The product may only be modified or added to by the supplier. Improper use! Never place objects against the door panel, against the roller or in the guides. Never attach any components to the door panel which could increase its weight. Never use the door as a hoist. Never climb on the door panel. Never open and close the door using any other switches than those fitted for that purpose. Warranty conditions Metaalunie terms and conditions General terms and conditions of delivery and payment issued by Metaalunie (the Dutch organisation for small and medium-sized enterprises in the metal industry), referred to as METAALUNIE TERMS AND CONDITIONS, formerly SMECOMA TERMS AND CONDITI- ONS, filed with the Registry of the Court of Rotterdam on 1 January 2001. Issued by Metaalunie Postbus 2600 3430 GA Nieuwegein 2 Gebruikshandleiding / User manual / Gebrauchsanweisung

Product description The Novoferm Speedroller is an electrically driven fast action roller door for use in industrial and commercial buildings. It can be used for energy saving, draught exclusion and climate control. Specification, construction The Novoferm Speedroller is a door without balance springs, consisting of a door panel that is rolled up by an electrically driven roller above the opening. The door panel is made of horizontal sections composed of reinforced PVC sheet, linked together by means of aluminium reinforcement profiles. The door panel is fitted with a transparent PVC vision section at a height of between approx. 1200 and 2200 mm. The closing edge of the door panel consists of an aluminium beam with a rubber seal. U-shaped channels with brush draught seals guide the door panel at the sides. The side guides and the bearing plates form a unit on which the roller and the drive are mounted. Materials The side guides are made of set Sendzimir galvanised steel channels fitted with brush draught seals that can be removed for installation and maintenance. The horizontal roller is made of steel. The bottom beam is made of aluminium. The door panel is made of 1.2 mm thick, polyester-reinforced PVC. It is available in blue, orange, yellow or black and is fitted as standard with a vision section. Drive The drive unit consists of an electric motor/gearbox unit and a built-in anti-roll-off device. The roller is driven directly. Controls The control system incorporates a variety of functions such as: controllable open position duration (dead man mode) service and operating mode LED indicator for monitoring the various functions choice of permanently open or permanently closed. Operation The control box has two push buttons (open/close) as standard and an emergency stop switch. The power can be switched off completely by disconnecting the CE plug. Various actuators can be used: pull switch, key switch, push button, photocell, radar, induction loop detection or remote control with a transmitter and a receiver. Other types of actuator on request. Safety devices in the event of a power failure the door can be cranked open manually with the crank supplied. the bottom beam is fitted with a self-testing safety edge which stops the or immediately causes it to re-open if an obstacle is encountered during closure. This safety device is moisture-proof. the side guide channels are fitted as standard with a safety photocell and a reflector (250 mm from the floor). The door will not close if the beam is broken. the drive is fitted as standard with an anti-roll-off device. Fittings/Options/Accessories door panel 3 mm thick, transparent, blue or orange plastic rain hood over drive/roller or both side guide channels and hood painted in choice of RAL colour aluminium Break Away end units in bottom beam (crash resistant) other electrical supply specifications besides 3N~400V/50Hz/16A electrical components IP65 frequency inverter control: opening speed...approx. 1.5 m/s closing speed...approx. 0.75 m/s actuation using push buttons, pull switches, photocells, radar, induction loop or remote control half-height stop (for pedestrian access) interlock switching in combination with another door traffic light switching (red/green or red and green) SPEEDROLLER 3

Mounting structure requirements and connection the power supply must be present within 500 mm of the control box required installation space as indicated in the installation guide. Technical specifications Dimensions maximum width...4000 mm maximum height...5000 mm max. wind resistance...5 Beaufort space required, non-drive side (roller height)...160 mm space required, drive side...300 mm space required for installation, drive side...min. 550 mm space required, side guide channels...110 mm headroom...575 mm Technical specifications of electric motor mains voltage...3n~400v/50hz/16a degree of protection...ip54 power consumption...max. 2 kw Performance opening and closing speed...approx. 1 m/s Operating and using the door Push buttons [i] and [m] on the door of the control box Push button [i] has two different functions: timer function If push button [i] is pressed briefly (less than 1.5 seconds), the door opens and closes automatically after the set open position delay. Summer setting When push button [i] is pressed, the door remains open. The door can be closed by pressing push button [m]. Reset after safety edge protection actuated After safety edge protection is actuated, reset by pressing push button [m]. STOP button Use the STOP button to stop the door in any position. An external UP/STOP/DOWN push button box can be connected to the control box (optional). Operating the timer The door opens when the timer input is activated. A timer starts running as soon as the door is fully open. The door closes automatically at the end of the set time. The open position delay is set by means of a potentiometer on the PCB. The timer can be operated with the following controls: push buttons, pull switches, photocells, radar, radio receiver with remote control, induction loop detector. Setting the timer The time is set with potentiometer P2 (on the control board in the control box). Turn it clockwise to shorten the open position delay and anti-clockwise to increase it. 4 Gebruikshandleiding / User manual / Gebrauchsanweisung

Door open/door closed control When the door open/door closed input is activated with the door closed, the door opens. When the door open/door closed input is activated with the door open, the door closes. The door-open/door-closed feature can be operated with the following controls: push buttons, pull switches, radio receiver with remote control Emergency operation in case of a power failure Make sure you are standing on a sufficiently firm surface next to the drive. Take the drive crank and insert it into the drive from underneath. Release the motor brake (depress the handle at the top of the drive) and crank the door open or closed. Faults Faults in standard version Faults you can fix yourself: standard door version: The door panel has come out of the guides Disconnect the power plug Stop the door and rehang the curtain and bottom beam in the guide channel (lift on one side and rehang). Then open and close the door in a controlled manner (1) by about 0.5 m at a time. (1) To do this, press the Up or Down buttons and the Stop button alternately. The door is completely unresponsive Check that it is connected to the mains power Faults in the timer control box The door does not respond to connected controls Is the power on? (Yellow LED on the box is on) The door no longer closes Check the power supply and the safety photocell setting. The door will not close when the red LED on the box is on (see also 7.2). Faults you CANNOT fix yourself: Have the following information to hand before you contact your maintenance company: the serial number (s/n) located on the type plate (you will find this on one of the side guides or on the control box (if applicable). SPEEDROLLER 5

Maintenance Lubrication points General all rotation points are self-lubricating so they are maintenance-free. in extreme conditions (aggressive environment), we recommend lubricating all rotation points once every six months (or as necessary). Daily remove dirt and obstacles that may impede the door s operation. Weekly Check the drive for leaks Check the door for damage Check that the door is operating properly Monthly Check the operation of the motor brake (this must click audibly when the door is opened and closed) Annually The operation of the door and its structural condition must be checked once per year by a qualified engineer. A maintenance contract can be taken out for this purpose. Cleaning the door panel The door panel is made of PVC. Do not use any corrosive substances; only use water, neutral soap or a special door panel cleaner. NB! All other forms of maintenance must be carried out by a suitably qualified engineer. 6 Gebruikshandleiding / User manual / Gebrauchsanweisung

EU Declaration of Conformity to EN 13241-1 In accordance with EN 13241-1 Industrial, commercial and garage doors and gates - Product Standard Annex 2A Novoferm Nederland BV Industrieweg 9 4181 CA Waardenburg The Netherlands Hereby declares that the Novoferm SPEEDROLLER series fast action roller doors Satisfy all the relevant requirements of the EC Construction Products Directive (89/106/EEC) and, in combination with the factory-specified GFA drive, Satisfy all relevant requirements of: EC Construction Products Directive (89/106/EEC) EC Machinery Directive (98/37/EEC) Low Voltage Electrical Equipment Directive (73/23/EEC) EMC Directive (89/336/EEC) The following harmonised standard has been applied: EN 13241-1 Industrial, commercial and garage doors and gates - Product Standard Conformity has been verified by the following notified body: RWTÜV Systems GmbH Notified Body 0044 Langemarckstrasse 20 D 45141 Essen Waardenburg, January 2011 Signature: R. Schackmann Managing Director, Novoferm Nederland BV Installation company s declaration We declare that we have complied with the manufacturer s instructions. Company stamp Installation company : Street : Postcode/Place : Phone/fax : Delivery Place : Location : Date : Name of engineer : Signature of engineer : SPEEDROLLER 7

Delivery checklist Location of the door Operational on Checked by Installation/maintenance checklist Door panel Condition of door panel... Attachment to roller... Attachment to bottom beam... Welds in door panel... Section clamps... Condition of door panel hinges... Bottom beam Condition of bottom beam channel... Guides... Floor rubber... Break away *... Guide Draught seal... Column attachment... Attachment of roller caps... Drive Attachment of bearing consoles... Motor attachment... Leaks... Motor brake... End terminals (settings)... Control box Push buttons on box... Stop switch... General cabling... Controls Push button*... Pull switch*... Photocell + reflector *... Radar *... Induction loop *... Receiver *... Hand-held transmitter *... Key switch *... Explosion-safe* power conductor, intermediate hinge... Door panel earthling... Tensioning and balancing system * Attachment of tension belts... Return pulley for tension belt... Tension belts... Tension belt flange... Rain cover* Attachment... Seal tightness... Various Maintenance sticker... Type plate... Safety devices Safety edge protection... Safety photocell... * if applicable 8 Gebruikshandleiding / User manual / Gebrauchsanweisung

Work performed Date work performed by Work performed Date work performed by SPEEDROLLER 9

Work performed Date work performed by Work performed Date work performed by 10 Gebruikshandleiding / User manual / Gebrauchsanweisung

Work performed Date work performed by Work performed Date work performed by SPEEDROLLER 11