HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

Similar documents
HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

MEDIUM VOLTAGE FUSES FOR CAPACITORS NORTH AMERICAN STYLE

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

Limitor -G General Purpose Fuses

FUSES. Safety through quality

HHBO-B. High Voltage Fuses to British Standards. Fuses for protection of oil insulated transformer mains

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Medium Voltage current limiting Fuse links

Medium Voltage current limiting Fuse links

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

High voltage current limiting Fuse links type CEF

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

General information on current-limiting fuse-links. The main characteristics of the CNC fuse-links. Construction. Operating.

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

High-voltage high-breaking capacity VV fuse-links

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

High voltage high-breaking capacity VV fuse-links

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

Protistor size 70 gr 690VAC (IEC)

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

High-voltage high-breaking capacity VV fuse-links

Ultra Rapid Fuses. For Semiconductor Protection

Ultra-Rapid Fuse Links for the Protection of Semiconductor Rectifiers

INDUSTRIAL CYLINDRICAL FUSE LINKS

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

Low voltage NH knife-blade fuse-links

CYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

RAPIDPLUS. high speed fuse links for semiconductors

Voltage and Auxiliary Transformer Fuse Links

Section ( VI ) TECHNICAL SPECIFICATIONS AND SCHEDULES

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

LOW VOLTAGE FUSES EUROPEAN NH KNIFE-BLADE FUSE SYSTEM

RAPIDPLUS. high speed fuse links for semiconductors

High-Voltage Fuse Links according to IEC

Medium voltage products. Fuses

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES

MEDIUM VOLTAGE DIN Fuse-Links

PowerIT Indoor Voltage Transformer Fuses, WBP. Outdoor Voltage Transformer Fuses, BRT. Catalogue 1YMB en. Industrial IT.

Mica Element Support. Compacted Quartz Sand. Length B

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Thermal system protection of switchgear through high voltage fuse links with integrated temperature limiter under consideration of IEC 420:1990

CYLINDRICAL FUSES CYLINDRICAL FUSES

High-Voltage Fuse-Links

X-Limiter full-range current-limiting fuse

NEOZED D0 fuse-links gg 400/440VAC

Medium voltage products. Fuses

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits

HD4. Gas insulated MV circuit-breakers kv A ka

Bussmann 7.2 kv Medium voltage fuse links

Standardized fuse characteristics

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

Low-Peak 600V Class RK1

Current Limiting Fuses, CEF Motor Circuits Fuses, CMF. Catalogue 1YMB en. Industrial IT. enabled

Medium voltage fuses Medium voltage fuses

MEDIUM VOLTAGE DIN Fuse-Links

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

SX Full-Range Current-Limiting Fuse. Power & High Voltage Elastimold & Hi-Tech Fuse Products

Semiconductor Fuses European Fuses

onlinecomponents.com

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

3.6. Current Limiting Fuses. Contents. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

HIGH VOLTAGE CURRENT LIMITING FUSE-LINKS CAPABLE OF BREAKING ALL CURRENTS THAT CAUSE MELTING OF THE FUSE-ELEMENT. D. van der Scheer H.F.J.

Air-insulated switchgear UniGear type ZS1

I B D Q I B D Q O I B D Q O

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Protistor size 31 ar 690VAC (IEC) / 700VAC (UL)

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

URDC-PV. Features and Benefits FUSES. URPV Fuses for PV Semiconductor Protection. gpv. Class: Voltage ratings: 600V DC to 1500V DC.

HIGH VOLTAGE FUSE-LINKS HIGH VOLTAGE FUSE-LINKS WITH THERMAL STRIKER HIGH VOLTAGE FUSES POWER NEEDS CONTROL

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

EUROPEAN HIGH VOLTAGE FUSES

HV-Fuse-links SSK type SSK 10/02

FX Full-Range Current-Limiting Fuse

Fuses are the most effective and economic ways of protection against short circuits in m.v. installations.

Extensible Unit - VCE2a

Rapier AX Air Break Switch Disconnector. engineering brilliant solutions

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)

OPTIONAL. Active Arc Eliminator - Safest in the world

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

DRIWISA HIGH VOLTAGE CURRENT-LIMITING FUSES HIGH INTERRUPTING CAPACITY INDOOR AND OUTDOOR USE

شركة كهرباء محافظة القدس المساهمة المحدودة

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

Product Catalog Medium Voltage Fuses. Circuit Protection

fuse-links & fuse holders PHOTOVOLTAIC

NH Solid Blades 690 VAC sizes 000 to 3

Low Voltage Fuses. Safety in Focus. ZVEI.ppt / / 1

Transcription:

HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgears Introduction Medium voltage fuse-links according to British Standard are back-up fuse-links for the protection of substations up to 24 kv. The fuse-links of this section comply with the following national and international standards: - IEC 60282-1 - BS 2692-1 - ESI 12-8 Design and construction of these fuse-links follow the well-proven concept of all SIBA high voltage fuse-links. For pressure resistant encapsulation, high grade ceramic is used. Contact material consists of silver plated high conductivity copper. The pure silver melting elements have appropriate notches to ensure small time-current curve tolerances and low let-through currents. The arc quenching quartz sand is subject to particular survey criteria regarding its composition, grain size and humidity content. Medium-Voltage fuses for installation in oil insulated switchgear according to British Standard Fuse-links for oil insulated switchgear These fuse-links comply with the requirements for tightness under oil as well as special mechanical properties for use in oil filled switchgears. The fuse-links are fitted with a striker and are very useful in Fuse/Switch-combinations, which comply with the requirements of IEC 62271 part 105. For installations of fuse-links in oil filled transformers please refer to section HHO of this catalogue. HHB 1

HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgear Selection Guide Type Rated Length Class Part No. Selector Technical Voltage Guide Data [Old BS-Code] [AC kv] [mm] [Page] [Page] FO 1 7.2 254 Back-up / Oiltight 30 132 36 HHB 3 HHB 8 FO 2 7.2 359 Back-up / Oiltight 30 234 36 HHB 3 HHB 8 FO 1 12 254 Back-up / Oiltight 30 144 36 HHB 4 HHB 9 FO 2 12 359 Back-up / Oiltight 30 237 36 HHB 5 HHB 9 FO 1 15.5 254 Back-up / Oiltight 30 293 36 HHB 6 HHB 10 FO 2 15.5 359 Back-up / Oiltight 30 294 36 HHB 6 HHB 10 FO 2 24 359 Back-up / Oiltight 30 156 36 HHB 7 HHB 11 HHB 2

HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgear Type FO 1 Rated Voltage Class Standard L= 254 mm AC 7.2 kv Back-up / Oiltight BS 2692-1 IEC 60282-1 ESI 12-8 Rated Part No. D= Diameter Rated Breaking Weight Pack Technical Current Current Data [A] [inch] [mm] [ka] [kg/1] [Page] 6.3 30 132 36.6.3 2.5 63.5 40 1.8 1 HHB 8 10 30 132 36.10 2.5 63.5 40 1.8 1 HHB 8 16 30 132 36.16 2.5 63.5 40 1.8 1 HHB 8 20 30 132 36.20 2.5 63.5 40 1.8 1 HHB 8 25 30 132 36.25 2.5 63.5 40 1.8 1 HHB 8 31.5 30 132 36.31.5 2.5 63.5 40 1.8 1 HHB 8 40 30 132 36.40 2.5 63.5 40 1.8 1 HHB 8 50 30 132 36.50 2.5 63.5 40 1.8 1 HHB 8 63 30 132 36.63 2.5 63.5 40 1.8 1 HHB 8 80 30 132 36.80 2.5 63.5 40 1.8 1 HHB 8 100 30 132 36.100 2.5 63.5 40 1.8 1 HHB 8 112 30 132 36.112 2.5 63.5 40 1.8 1 HHB 8 Type FO 2 Rated Voltage Class Standard L= 359 mm AC 7.2 kv Back-up / Oiltight BS 2692-1 IEC 60282-1 ESI 12-8 Rated Part No. D= Diameter Rated Breaking Weight Pack Technical Current Current Data [A] [inch] [mm] [ka] [kg/1] [Page] 125 A 30 234 36.125 2.5 63.5 40 2.5 1 HHB 8 F 1.57 (40 mm) N 0.50 (13 mm) O 0.30 (8 mm) HHB 3

HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgear Type FO 1 Rated Voltage Class Standard L= 254 mm AC 12 kv Back-up / Oiltight BS 2692 IEC 60282-1 ESI 12-8 Rated Part No. D= Diameter Rated Breaking Weight Pack Technical Current Current Data [A] [inch] [mm] [ka] [kg/1] [Page] 6.3 30 144 36.6.3 2.5 63.5 40 1.8 1 HHB 9 10 30 144 36.10 2.5 63.5 40 1.8 1 HHB 9 16 30 144 36.16 2.5 63.5 40 1.8 1 HHB 9 20 30 144 36.20 2.5 63.5 40 1.8 1 HHB 9 25 30 144 36.25 2.5 63.5 40 1.8 1 HHB 9 31.5 30 144 36.31.5 2.5 63.5 40 1.8 1 HHB 9 40 30 144 36.40 2.5 63.5 40 1.8 1 HHB 9 50 30 144 36.50 2.5 63.5 40 1.8 1 HHB 9 63 30 144 36.63 2.5 63.5 40 1.8 1 HHB 9 80 30 144 36.80 2.5 63.5 40 1.8 1 HHB 9 F 1.57 (40 mm) N 0.50 (13 mm) O 0.30 (8 mm) HHB 4

HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgear Type FO 2 Rated Voltage Class Standard L= 359 mm AC 12 kv Back-up / Oiltight BS 2692 IEC 60282-1 ESI 12-8 Rated Part No. D= Diameter Rated Breaking Weight Pack Technical Current Current Data [A] [inch] [mm] [ka] [kg/1] [Page] 6.3 30 237 36.6.3 2.5 63.5 40 2.5 1 HHB 9 10 30 237 36.10 2.5 63.5 40 2.5 1 HHB 9 16 30 237 36.16 2.5 63.5 40 2.5 1 HHB 9 20 30 237 36.20 2.5 63.5 40 2.5 1 HHB 9 25 30 237 36.25 2.5 63.5 40 2.5 1 HHB 9 31.5 30 237 36.31.5 2.5 63.5 40 2.5 1 HHB 9 40 30 237 36.40 2.5 63.5 40 2.5 1 HHB 9 50 30 237 36.50 2.5 63.5 40 2.5 1 HHB 9 63 30 237 36.63 2.5 63.5 40 2.5 1 HHB 9 80 30 237 36.80 2.5 63.5 40 2.5 1 HHB 9 100 30 237 36.100 2.5 63.5 40 2.5 1 HHB 9 125 30 237 36.125 2.5 63.5 40 2.5 1 HHB 9 F 1.57 (40 mm) N 0.50 (13 mm) O 0.30 (8 mm) HHB 5

HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgear Type FO 1 Rated Voltage Class Standard L= 254 mm AC 15.5 kv Back-up / Oiltight BS 2692 IEC 60282-1 ESI 12-8 Rated Part No. D= Diameter Rated Breaking Weight Pack Technical Current Current Data [A] [inch] [mm] [ka] [kg/1] [Page] 6.3 30 293 36.6.3 2.5 63.5 40 1.8 1 HHB 10 10 30 293 36.10 2.5 63.5 40 1.8 1 HHB 10 16 30 293 36.16 2.5 63.5 40 1.8 1 HHB 10 20 30 293 36.20 2.5 63.5 40 1.8 1 HHB 10 25 30 293 36.25 2.5 63.5 40 1.8 1 HHB 10 31.5 30 293 36.31.5 2.5 63.5 40 1.8 1 HHB 10 40 30 293 36.40 2.5 63.5 40 1.8 1 HHB 10 50 30 293 36.50 2.5 63.5 40 1.8 1 HHB 10 63 30 293 36.63 2.5 63.5 40 1.8 1 HHB 10 Type FO 2 Rated Voltage Class Standard L= 359 mm AC 15.5 kv Back-up / Oiltight BS 2692 IEC 60282-1 ESI 12-8 Rated Part No. D= Diameter Rated Breaking Weight Pack Technical Current Current Data [A] [inch] [mm] [ka] [kg/1] [Page] 6.3 30 294 36.6.3 2.5 63.5 40 2.5 1 HHB 10 10 30 294 36.10 2.5 63.5 40 2.5 1 HHB 10 16 30 294 36.16 2.5 63.5 40 2.5 1 HHB 10 20 30 294 36.20 2.5 63.5 40 2.5 1 HHB 10 25 30 294 36.25 2.5 63.5 40 2.5 1 HHB 10 31.5 30 294 36.31.5 2.5 63.5 40 2.5 1 HHB 10 40 30 294 36.40 2.5 63.5 40 2.5 1 HHB 10 50 30 294 36.50 2.5 63.5 40 2.5 1 HHB 10 63 30 294 36.63 2.5 63.5 40 2.5 1 HHB 10 80 30 294 36.80 2.5 63.5 40 2.5 1 HHB 10 90 30 294 36.90 2.5 63.5 40 2.5 1 HHB 10 F 1.57 (40 mm) N 0.50 (13 mm) O 0.30 (8 mm) HHB 6

HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgear Type FO 2 Rated Voltage Class Standard L= 359 mm AC 24 kv Back-up / Oiltight BS 2692 IEC 60282-1 ESI 12-8 Rated Part No. D= Diameter Rated Breaking Weight Pack Technical Current Current Data [A] [inch] [mm] [ka] [kg/1] [Page] 6.3 30 156 36.6.3 2.5 63.5 40 2.5 1 HHB 11 10 30 156 36.10 2.5 63.5 40 2.5 1 HHB 11 16 30 156 36.16 2.5 63.5 40 2.5 1 HHB 11 20 30 156 36.20 2.5 63.5 40 2.5 1 HHB 11 25 30 156 36.25 2.5 63.5 40 2.5 1 HHB 11 31.5 30 156 36.31.5 2.5 63.5 40 2.5 1 HHB 11 40 30 156 36.40 2.5 63.5 40 2.5 1 HHB 11 50 30 156 36.50 2.5 63.5 40 2.5 1 HHB 11 F 1.57 (40 mm) N 0.50 (13 mm) O 0.30 (8 mm) HHB 7

HHB Electrical Characteristics Length Rated Voltage L= 254 mm AC 7.2 kv Use under Oil / Oiltight Rated Part No. Rated Breaking Pre-arcing Total I 2 t-value Current Current I 2 t-value @ 3 kv @ 7.2 kv [A] [ka] [A 2 s] [A 2 s] [A 2 s] 6.3 30 132 36.6.3 40 14 80 140 10 30 132 36.10 40 50 270 450 16 30 132 36.16 40 190 1 070 1 800 20 30 132 36.20 40 290 1 680 2 900 25 30 132 36.25 40 600 3 670 6 100 31.5 30 132 36.31.5 40 1 000 6 000 10 000 40 30 132 36.40 40 2 300 13 400 22 300 50 30 132 36.50 40 2 800 21 600 36 000 63 30 132 36.63 40 6 500 38 200 65 500 80 30 132 36.80 40 9 900 56 500 100 000 90 30 132 36.90 40 15 500 91 400 157 000 100 30 132 36.100 40 22 200 127 200 218 500 112 30 132 36.112 40 28 300 166 700 278 000 Length Rated voltage L= 359 mm AC 7.2 kv Use under Oil / Oiltight Rated Part No. Rated Breaking Pre-arcing Total I 2 t-value Current Current I 2 t-value @ 3 kv @ 7.2 kv [A] [ka] [A 2 s] [A 2 s] [A 2 s] 125 30 234 36.125 40 37 100 218 500 364 200 Time-current characteristics and cut-off current diagram please refer to pages HHB 12 and HHB 13 HHB 8

Electrical Characteristics HHB Length Rated Voltage L= 254 mm AC 12 kv Use under Oil / Oiltight Rated Part No. Rated Breaking Pre-arcing Total I 2 t-value Current Current I 2 t-value @ 6 kv @ 12 kv [A] [ka] [A 2 s] [A 2 s] [A 2 s] 6.3 30 144 36.6.3 40 14 80 140 10 30 144 36.10 40 50 270 450 16 30 144 36.16 40 190 1 070 1 800 20 30 144 36.20 40 290 1 680 2 900 25 30 144 36.25 40 600 3 670 6 100 31.5 30 144 36.31.5 40 1 000 6 000 10 000 40 30 144 36.40 40 2 300 13 400 22 300 50 30 144 36.50 40 2 800 21 600 36 000 63 30 144 36.63 40 6 500 38 200 65 500 80 30 144 36.80 40 9 900 56 500 100 000 Length Rated Voltage L= 359 mm AC 12 kv Use under Oil / Oiltight Rated Part No. Rated Breaking Pre-arcing Total I 2 t-value Current Current I 2 t-value @ 6 kv @ 12 kv [A] [ka] [A 2 s] [A 2 s] [A 2 s] 6.3 30 237 36.6.3 40 14 80 140 10 30 237 36.10 40 50 270 450 16 30 237 36.16. 40 190 1 070 1 800 20 30 237 36.20 40 290 1 680 2 900 25 30 237 36.25 40 600 3 670 6 100 31.5 30 237 36.31.5 40 1 000 6 000 10 000 40 30 237 36.40 40 2 300 13 400 22 300 50 30 237 36.50 40 2 800 21 600 36 000 63 30 237 36.63 40 6 500 38 200 65 500 80 30 237 36.80 40 9 900 56 500 100 000 100 30 237 36.100 40 22 200 127 200 218 500 125 30 237 36.125 40 37 100 218 500 364 200 Time-current characteristics and cut-off current diagram please refer to pages HHB 12 and HHB 13 HHB 9

HHB Electrical Characteristics Length Rated Voltage L= 254 mm AC 15.5 kv Use under Oil / Oiltight Rated Part No. Rated Breaking Pre-arcing Total I 2 t-value Current Current I 2 t-value @ 10 kv @ 15.5 kv [A] [ka] [A 2 s] [A 2 s] [A 2 s] 6.3 30 293 36.6.3 40 14 80 140 10 30 293 36.10 40 50 270 450 16 30 293 36.16 40 190 1 070 1 800 20 30 293 36.20 40 290 1 680 2 900 25 30 293 36.25 40 600 3 670 6 100 31.5 30 293 36.31.5 40 1 000 6 000 10 000 40 30 293 36.40 40 2 300 13 400 22 300 50 30 293 36.50 40 2 800 21 600 36 000 63 30 293 36.63 40 6 500 38 200 65 500 Length Rated Voltage L= 359 mm AC 15.5 kv Use under Oil / Oiltight Rated Part No. Rated Breaking Pre-arcing Total I 2 t-value Current Current I 2 t-value @ 10 kv @ 15.5 kv [A] [ka] [A 2 s] [A 2 s] [A 2 s] 6.3 30 294 36.6.3 40 14 80 140 10 30 294 36.10 40 50 270 450 16 30 294 36.16 40 190 1 070 1 800 20 30 294 36.20 40 290 1 680 2 900 25 30 294 36.25 40 600 3 670 6 100 31.5 30 294 36.31.5 40 1 000 6 000 10 000 40 30 294 36.40 40 2 300 13 400 22 300 50 30 294 36.50 40 2 800 21 600 36 000 63 30 294 36.63 40 6 500 38 200 65 500 80 30 294 36.80 40 9 900 56 500 100 000 Time-current characteristics and cut-off current diagram please refer to pages HHB 12 and HHB 13 HHB 10

Electrical Characteristics HHB Length Rated Voltage L= 359 mm AC 24 kv Use under Oil / Oiltight Rated Part No. Rated Breaking Pre-arcing Total I 2 t-value Current Current I 2 t-value @ 10 kv @ 24 kv [A] [ka] [A 2 s] [A 2 s] [A 2 s] 6.3 30 156 36.6.3 40 14 80 140 10 30 156 36.10 40 50 270 450 16 30 156 36.16 40 190 1 070 1 800 20 30 156 36.20 40 290 1 680 2 900 25 30 156 36.25 40 600 3 670 6 100 31.5 30 156 36.31.5 40 1 000 6 000 10 000 40 30 156 36.40 40 2 300 13 400 22 300 50 30 156 36.50 40 2 800 21 600 36 000 Time-current characteristics and cut-off current diagram please refer to pages HHB 12 and HHB 13 HHB 11

HHB Electrical Characteristics Time-Current Characteristics Use under Oil t(s) Virtual Pre-arcing time RMS Prospective Current I(A) Applicable for all fuse-links shown on pages HHB 3 - HHB 7 HHB 12

Electrical Characteristics HHB Cut-Off Current Diagram Use under Oil îc (ka) Cut-off Current Peak Prospective Short Circuit Current I(kA) Applicable for all fuse-links shown on pages HHB 3 - HHB 7 HHB 13

HHB Notes HHB 14