RF Control of Pneumatic Actuators

Similar documents
Push buttons are of two types i) Momentary push button ii) Maintained contact or detent push button

Ch 4 Motor Control Devices

JIS symbols used in this catalog are old symbols following JISB0125-1: Refer to JISB0125-1: 2007 or JFPS2011: 2006 for new symbols.

Lesson 5: Directional Control Valves

Practical No: Aim: List out the tools required for Instrumentation Workshop and draw the diagram of any two tools

MECHATRONICS LAB MANUAL

Solenoid valve. Solenoid Coil

Input, Control and Processing elements

TWO HAND NON-TIE-DOWN CONTROLS SC SERIES

For a proper and safe Installation Read the entire manual before Installation

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:

Electrical Control System Components Basics of Magnetic Control :

Redundant Control System

three different ways, so it is important to be aware of how flow is to be specified

4 Redundant Control System

Syslog Technologies Innovative Thoughts

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Application Note : Comparative Motor Technologies

The pneumatic circuit and parts' list needed to perform this operation are shown by Figure C.1.

Modern Safety Systems and Advanced Fluid Power Solutions

Troubleshooting Bosch Proportional Valves

ATA Series (Patented)

Thank You for Attending Today s Webinar. Today s Featured Speaker

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

MEP-A Press safety valves

Sorting Line with Detection 24V

Design and Fabrication of Sequencing Circuit with Single Double Acting Cylinder

For system diagrams and component identification

FACTORY OF ELECTRIC APPARATUS EMA ELFA

Automation is the techniques and equipment used to achieve automatic operation or control.

DISCUSSION OF FUNDAMENTALS. A hydraulic system can be controlled either manually or automatically:

11.AWD Transfer System

BattleBots IQ Engineering Education System Every student and every teacher can be a design engineer

International Journal of Scientific & Engineering Research Volume 8, Issue 6, June ISSN PNEUMATIC GEAR CHANGER FOR FOUR WHEELERS

ADD-ON REMOTE STARTER TO AFTERMARKET SYSTEM

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani

In-Head Automatic Swing Door Operator DORMA. ED 200i

5 Port, 2 Position Double Solenoid Inline Valve (Series 524)

700 Type P & PK DC Relays Timer Units Latch Units Series A and B Construction. Renewal Parts

FUNCTIONAL SAFETY SOLUTIONS in Solenoid Valves

Lesson 4: Fluid Systems

Personal Restraint Hydraulic Lock "LE" for passenger restraint systems

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

Introduction. General Information. Systems Operation

Achieving Required Safety Levels Using a Pneumatic Safety Exhaust Valve

TECHNICAL CHARACTERISTICS

VALVE BODY. Shift Pressure Control Solenoid Valve. 1. Leaf spring 2. Contact spring 3. Conductor track 4. O-ring 5. O-ring 6.

Troubleshooting The Transmission Hydraulic System

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Full-featured operator with slim profile for moderate to high traffic applications LOW ENERGY OPERATOR CATALOG

Syslog Technologies Innovative Thoughts

HARDWIRE VS. WIRELESS FAILSAFE CONTROL SYSTEM. The answer is No.

2006 MINI Cooper S GENINFO Starting - Overview - MINI

Syslog Technologies Innovative Thoughts

Actuators and directional control valves

Terms. Direct Acting (DA) The action of a controller that increases its branch line pressure as the controlled variable increases

York J Model Compressors Unloading Characteristics Styles A-F Solenoid Valve

A SIMPLIFIED METHOD FOR ENERGIZING THE SOLENOID COIL BASED ON ELECTROMAGNETIC RELAYS

[You may download this article at: ]

Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition)

Multi-point closer/holder with motion sensor 7100SZ DOOR CLOSER CATALOG

Programmable Logic Controller. Mat Nor Mohamad

Selecting & Integrating Safety Exhaust Valves White Paper

Shaper Automation Using Electro-Pneumatic Devices And Plcs

Chapter 33 Fundamentals of Hydraulic and Air-Over-Hydraulic Braking Systems

Pneumatic Trainer Kit

BERMAD Irrigation. Solenoid Valves S - Series. Water Control Solutions

SECTION CONTROL VALVE ACTUATORS

USE AN ENGINEERED APPROACH TO TAILOR A PERFECT STANDARD GAS SPRING FOR YOUR DESIGN A GUIDE TO GAS SPRING DESIGN AND CUSTOMIZATION WH ITE PA P E R

FLUID POWER P&IDs. IDENTIFY the symbols used on engineering fluid power drawings for the following components:

PORTEO PORTEO. Weight Configurations Max door weight 100kg. Parameters Max door width 1100mm Max opening angle 110

2005 FIRST Pneumatic Manual

THROTTLE & RPM-ACTIVATED NITROUS CONTROL SYSTEM P/N 15970NOS

VEX ELECTROMAGNET. Make It Real CAD Engineering Challenge

Technical Principles of Valves

Actuated Valves PRICING

Introduction to Internet of Things Prof. Sudip Misra Department of Computer Science & Engineering Indian Institute of Technology, Kharagpur

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks:

Safety Exhaust Valve Integration Guide

1. Anti-lock Brake System (ABS)

Two Channel Remote Shutdown Device

SD3-60 AIRCRAFT MAINTENANCE MANUAL - DESCRIPTION & OPERATION

CENTAC Inlet and Bypass Valve Positioners

Torque Converter, Transmission Pump, Screen And Filter

pg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept

1. INTRODUCTION. Anti-lock Braking System

AIRCRAFT GENERAL KNOWLEDGE (1) AIRFRAME/SYSTEMS/POWERPLANT

The AW55-50SN transmission

MOTOR TERMINAL CONNECTIONS

The New Generation ISO Cylinders for a Dynamic Future

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

Continental Hydraulics Installation Manual CEM-AA-A

AP MOTRONIX PRIVATE LIMITED

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

ASSIGNMENT Chapter 4 AIRCRAFT ELECTRICAL SYSTEMS

Identify and Assemble the Pneumatic Components

Bringing Component Parts Together

CDI Revision Notes Term 1 ( ) Grade 12 Advanced Unit 2 Mechanical Systems

Cobra-S. Catalog Cobra-S

Transcription:

RF Control of Pneumatic Actuators In the world of Theater, it is becoming more and more common to see automated scenery set pieces which move under magic powers. One of the easiest ways to implement this theatrical magic is through the use of pneumatics. Pneumatic cylinders are devices which use air power to extend a pushrod or to rotate a lever. Pneumatics are especially easy to implement as they can be powered with a standard shop air compressor. In the industrial world, there are manufacturers which make radio control systems for pneumatic machinery. However, these systems are prohibitively expensive for theater practitioners. This document will outline the technologies and techniques required to create a shop-brew remote-controlled pneumatic actuation system. Valves Pneumatic cylinders are controlled by ducting compressed air to ports on the body of the cylinder. This routing of air is accomplished with high-pressure hose, fitting, and valves. It is the valves which control the motion of pneumatics. By opening a valve, air is routed to the input port on the cylinder. Valves can be manually or electrically actuated. Solenoid Valves The most common form of electrically actuated valve is the Solenoid valve. A solenoid is a combination of an electromagnet and a moveable piston. When electricity is applied to the electromagnetic coil, the movement of electrons creates a magnetic field which in turn moves the piston. In a solenoid valve, this movement is used to open the pathway through the valve. Solenoid valves range in price from $30 and up, depending on valve type and pressure rating. Solenoid Valve Types Solenoid valves come in six main varieties, useful for different applications: 2-way Normally Closed valves have a single inlet and a singe outlet. When electricity is applied, the valve is opened, and fluid is allowed to pass. The valve closes when electricity is removed.

2-way Normally Opened valves have a single inlet and a single outlet. When electricity is applied, the valve is closed, and the passage of fluid is blocked. Flow is resumed when electricity is removed. 3-Way Normally Closed valves have inlet, outlet, and exhaust ports. When electricity is applied, the fluid is allowed to pass from the inlet to the outlet. When electricity is removed, the inlet port is blocked and the outlet is connected to the exhaust port. 3-Way Normally Opened valves connect the inlet to the outlet when there is no electricity applied. When energized, the inlet is closed off and the outlet is connected to the exhaust. 3-Way Multi-Purpose valves act as A-B switchers for fluid control. The inlet can be connected to either of two outlets, allowing the valve to be used as either normally opened or normally closed, as well as as a selector to choose different paths of flow. 4-Way valves are used to operate a double-acting cylinder. A 4-way valve will extend a cylinder when energized, and retract it when de-energized. This reduces the number of pneumatic and electrical connections and ensures synchronicity of valve operation. Other Valve Considerations When choosing a solenoid valve, the following parameters must be taken into account: Pipe Size: The port size on the valve should be selected to accommodate the tubing and other connectors being used in a system. It also affects the flow rate of the valve. Flow Rate: The amount of fluid which can pass through a valve at a given pressure. This is useful when selecting valves to accommodate a certain volume of air cylinder. Operating Pressures: The Maximum pressure is the pressure at which the valve will no longer function, as the fluid pushes the solenoid opened or closed. Some valves particularly 4-way valves -- have a minimum operating pressure. A certain pressure differential must be maintained in order for the valve to remain opened. Electrical Ratings: Like any electrical equipment, solenoids operate at a given voltage and amperage. Valves are available in both AC and DC, with higherpressure valves usually having higher electrical demands.

RF Control of Solenoid Valves RF, or Radio Frequency remotes are common in applications where line-of-site transmission is not possible. The most common example of RF remote control is the garage door remote, which uses a weak radio signal to trigger the door motor. The same technology can be used to control solenoids and pneumatic systems. RF Relay boards are common finds in electronic kit catalogs and online retailers such as electronickits.com. These kits use a small remote to transmit a radio signal which is received by a decoder board. This board has several relays (electromechanical switches) which are closed, allowing the flow of electricity. These kit remote systems have a range of approximately 100, more than enough for most theatrical applications. RF Transmitter kits are available from 1 to 8 channels, and ranging in cost from $50.00 to $150.00 (respectively) for a remote transmitter and receiver/relay board. Multiple channels can be used to control different pneumatic elements. For example, a stage trap door may require one channel for actuation of locking pins, and another to prove the actual movement of the door. Different transmission frequencies are available in order to minimize interference from other transmitting equipment such as wireless microphones or noisy electrical connections. System Integration A complete RF controlled pneumatic system would consist of: Source of Compressed Air Pneumatic Cylinders Solenoid Valves and appropriate power supply RF Transmitter RF Receiver The compressed air is routed through hoses from the compressor to the valves, and from there to the cylinders. The valve will also have electrical connections in order to be actuated. Power from the power supply is run to the relay board, and then to the valve. Connected as such, the relay will be closed, and thus the valve actuated, when the proper remote signal is received. It is essential that the rated current of the solenoid valve not exceed the rated current of the relay board. If more amperage is needed, a more powerful relay can be connected to the relay board. The current flowing through the relay board energizes the larger relay, which completes the valve circuit.

Sources: www.valvestore.com -- huge selection of solenoid valves from various manufacturers, and lots of helpful information for selection. www.electronickits.com -- one of many suppliers of RF transmitter and receiver kits.

System Hook-up Diagram