Strand Lighting Inc Darin Way, Cypress, CA 90630, USA Tel: Fax:

Similar documents
Strand Lighting Offices

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

MOONRING 1.5 MOONRING 3

MAXLITE RKT LED Retrofit Kit

When using electrical equipment, basic safety precautions should always be followed including the following:

RSA-MRZ Installation Instructions

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

RSA-MRZ Installation Instructions

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Installation Instructions Shaper 1800 aircraft cable installation

INSTALLATION AND OPERATING INSTRUCTIONS

GP Dimming Panels 230 Volt (CE)

SAVE THESE INSTRUCTIONS

NT-300 Series Single Circuit Track System & Accessories

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

PDI PowerWave 2 Bus System

GP Dimming Panels 230 Volt (CE)

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Installation and Operation Instructions 10/04/13

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

RECESSED TRACK (120V) SPECIFICATIONS

Measurements are expressed in millimeters.

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET

MODELS SafeSite LED Linear, Class I Div V, 2 & 4 Versions

SURFACE TRACK (120/250V) SPECIFICATIONS

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Operating Instructions

ALL700RM-230V INSTALLATION INSTRUCTIONS

- Wiring Brochure Zone Manager 335

- Wiring Brochure Zone Manager 336

Illuminator System Series CM

Installation Instructions Central Battery Units

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

Installation Instructions: Eco Linear High Bay

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Braking Unit for Frequency Inverter Serie 3CV V 18,5 bis 55kW

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

ALL W INSTALLATION INSTRUCTIONS

MODELS. 2 & 4 Low Profile Linears

Installation Instructions - Continua Suspended LED

INTEGRID TRACK (120V) SPECIFICATIONS

Portable Pack USER MANUAL

Direct Communication Module

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

Operating Instructions

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

COMPACT BUSWAY 40 & 60 AMP HOUSING

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

Sivoia QED R Installation Instructions Please Leave for Occupant

Operation/Installation Instructions

ALL PURPOSE CNC/HEAVY DUTY

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

IMPORTANT SAFEGUARDS

Australian Wiring Instructions:

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual

Pretest Module 24 Three-phase Service Entrance

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

LP Dimming Panels. GRAFIK Systems

Application Description

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

AP9002. HQ004 and HQ006 Electric Actuator

24 Volt Eco Flex LED Neon Part Numbers: LFN-2700K, LFN-5800K

Sivoia QED. SVQ-10-PNL-230 Power Panel 230 V~ 50/60 Hz, 4 Amps maximum total current. Figure 1: Mounting Diagram and Dimensions.

MODELS 2 & 4 Top Conduit Linears

PART B BRAND SPECIFIC MANUAL

UHC-202 Hardware Guide

SAVE THESE INSTRUCTIONS!!

Track Accessories. Single Circuit Track. L Connector T Connector X Connector. Mini Connector Floating Canopy End Feed Kit.

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

INSTALLATION GUIDE AND USER MANUAL

ELECTRO-MECH SCOREBOARD CO.

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

Sconce INSTALLATION INSTRUCTIONS P34024W

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

UL AND CODE COMPLIANCE

MD-402 MD-412 BROTHER INDUSTRIES, LTD. E. C. Motor NAGOYA, JAPAN. From the library of: Superior Sewing Machine & Supply LLC

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

Transcription:

Strand Lighting Inc. 6603 Darin Way, Cypress, CA 90630, USA Tel: +1-714-230-8200 Fax: +1-714-899-0042 Strand Lighting Europe Ltd. Unit 2, Royce Road, Fleming Way, Crawley, West Sussex. United Kingdom Tel: +44-1293-554-010 Fax: +44-1293-554-019 Strand Lighting Asia Room 6-10, 20/F Delta House 3 On Yiu Street, Shatin, N.T. Hong Kong Tel: +852-2757-3033 Fax: +852-2757-1767 www.strandlighting.com The material in this manual is for information purposes only and is subject to change without notice. Strand Lighting assumes no responsibility for any errors or omissions which may appear in this manual. For comments and suggestions regarding corrections and/or updates to this manual, please contact your nearest Strand Lighting office. El contenido de este manual es solamente para información y está sujeto a cambios sin previo aviso. Strand Lighting no asume responsabilidad por errores o omisiones que puedan aparecer. Cualquier comentario, sugerencia o corrección con respecto a este manual, favor de dirijirlo a la oficina de Strand Lighting más cercana. Der Inhalt dieses Handbuches ist nur für Informationszwecke gedacht, Aenderungen sind vorbehalten. Strand Lighting uebernimmt keine Verantwortung für Fehler oder Irrtuemer, die in diesem Handbuch auftreten. Für Bemerkungen und Verbesserungsvorschlaege oder Vorschlaege in Bezug auf Korrekturen und/oder Aktualisierungen in diesem Handbuch, moechten wir Sie bitten, Kontakt mit der naechsten Strand Lighting-Niederlassung aufzunehmen. Le matériel décrit dans ce manuel est pour information seulement et est sujet à changements sans préavis. La compagnie Strand Lighting n'assume aucune responsibilité sur toute erreur ou ommission inscrite dans ce manuel. Pour tous commentaires ou suggestions concernant des corrections et/ou les mises à jour de ce manuel, veuillez s'll vous plait contacter le bureau de Strand Lighting le plus proche. Information contained in this document may not be duplicated in full or in part by any person without prior written approval of Strand Lighting Inc. Its sole purpose is to provide the user with conceptual information on the equipment mentioned. The use of this document for all other purposes is specifically prohibited. Certain features of the equipment described in this document may form the subject of patents or patent applications. Document Number: 85-1567 Version as of: May 7, 2009 S21 Dimmer Strip Up & Running Guide 2009 Philips Group. All rights reserved.

S21 Dimmer Strip Up & Running Guide Important Safeguards When using electrical equipment, basic safety precautions should always be followed including the following: a. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. b. Do not use outdoors. c. Do not mount near gas or electric heaters. d. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. e. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. f. Do not use this equipment for other than intended use. g. Refer service to qualified personnel. SAVE THESE INSTRUCTIONS. WARNING: You must have access to a main circuit breaker or other power disconnect device before installing any wiring. Be sure that power is disconnected by removing fuses or turning the main circuit breaker off before installation. Installing the device with power on may expose you to dangerous voltage and damage the device. A qualified electrician must perform this installation. WARNING: Refer to National Electrical Code and local codes for cable specifications. Failure to use proper cable can result in damage to equipment or danger to persons. CAUTION: Wire openings MUST have fittings or lining to protect wires/cables from damage. Use 75 C copper wire only! Aluminum wire may not be used. 1

Up & Running Guide S21 Dimmer Strip TABLE OF CONTENTS Preface...3 About this Guide...3 What You Should Have...3 Physical Installation...4 Connecting Power...5 Connecting DMX512...6 Setting the DMX512 Address...7 Dimmer Strips and Accessories...8 Technical Information...9 Mounting Hardware...10 Cheesbro Style Clamp: 71343...10 Single Pipe Hanger: 71347...11 Double Pipe Hanger: 71348...12 Wall Mount Hanger: 71349...12 Ceiling Mount Hanger: 71350...13 "C" Style Clamp: 82019...13 2

S21 Dimmer Strip Up & Running Guide PREFACE About this Guide The document provides installation instructions for the following S21 products: 71400 6 x 1200w 450ms S21 Dimmer Strip with GP connectors 71401 6 x 1200w 450ms S21 Dimmer Strip with GTL connectors 71402 6 x 1200w 450ms S21 Dimmer Strip with GR connectors 71403 3 x 2400w 800ms S21 Dimmer Strip with GP connectors 71404 3 x 2400w 800ms S21 Dimmer Strip with GTL connectors 71405 3 x 2400w 800ms S21 Dimmer Strip with GR connectors Load Connector Types: GP Grounded Stage Pin GTL Twistlock GR Edison NEMA 5-20R Please read all instructions before installing or using this product. Retain this guide for future reference. IMPORTANT INFORMATION. PLEASE READ! This unit is intended for installation in accordance with the National Electric Code and local regulations. It is also intended for indoor applications only. Before any electrical work is performed, disconnect power at the circuit breaker or remove the fuse to avoid shock or damage to the control. It is recommended that a qualified electrician perform this installation. What You Should Have The following items and materials are required in order to successfully install and operate this equipment. S21 Dimmer Strip Operating Instructions & Installation Guide. 71400 Series Dimmer Strip. DMX512 data cable. If you are missing any of these items, contact your dealer, or the person who provided your system. 3

Up & Running Guide S21 Dimmer Strip PHYSICAL INSTALLATION Figure 1: Cross-Section of S21 Dimmer Strip Enclosure 1 2 3 4 5 Track to capture 1/2" hex head bolt. Use to attach standard C clamps when the unit is to be hung below a pipe. Track to capture 5/16" carriage bolt. Use when the unit is to be mounted to a vertical member such as the bracket in a multi-pipe batten assembly. Unistrut compatible track. May be used for a variety of attachments. Fixtures may be bolted directly to it, pipes maybe hung from it using pipe hangers such as the Unistrut part number P1567. Brackets to mount the unit itself may also be attached here. Dimmer protection fin. Dimmer heat sinks. WARNING: In all cases where an S21 Dimmer Strip is hung above personnel, it must be equipped with safety cables or chains to prevent it from falling should the mounting means fail! Note: S21 Dimmer Strips are intended primarily for horizontal mounting. If they are mounted vertically their cooling capacity is somewhat diminished. Dimmers may run warmer than normal when mounted in other than a horizontal position. 4

S21 Dimmer Strip Up & Running Guide CONNECTING POWER WARNING: Product contains High Voltage within its enclosure! Remove power from unit before opening any panels. Make all field wiring connections to the terminals provided. Follow connection diagram on inside of field wiring compartment cover. Use 10/5 SO cable for portable applications. Use 20 amp rated conductors in conduit for hard-wired applications. Figure 2: Field Wiring Compartment of S21 Dimmer Strip 1 2 3 3/4" Knock-out for power wiring. Install cord grip or conduit here. Grounding Lug. Connect green Earth Ground conductor here. Phase Terminals. Connect three phase conductors here. Use following color code: Terminal Conductor Wire Connector A Phase A Black X B Phase B Red Y C Phase C Blue or Orange Z 4 5 Neutral Terminals. Connect white Neutral conductor here. Neutral Bus Jumpers. All three neutral terminals must be bused together for three phase operation. Standard 3-Phase Wiring Standard Single Phase Wiring hot hot hot Neu Neu Neu hot Neu hot Neu hot Neu A B C N1 N2 N3 phase N1 phase N2 phase N3 D1+2 D3+4 D5+6 D1+2 D3+4 D5+6 D1+2 D1+2 D3+4 D3+4 D5+6 D5+6 5

Up & Running Guide S21 Dimmer Strip CONNECTING DMX512 Make DMX512 connections via the 5-pin XLR connectors on the Head-End Processor panel. Use commercially manufactured DMX512 cables, or build your own using Belden type 9829 cable. Cable must be listed for RS-485 applications. Do not substitute other cable types. Figure 3: Head-End Processor for S21 Dimmer Strip 1 2 3 4 5 6 DMX512 Input Connector. Connect the DMX cable which is bringing data from your control console here. DMX512 Pass-Through Connector. Connect the DMX cable which is carrying data on to other dimmers here. Red LED Error indicators. DMX512 Termination Switch. Set to left hand position if unit is in the middle of the DMX cable run. Set to right hand position if unit is a t the end of the DMX cable run. Four-digit LED Display. Used for setting DMX512 address and other configuration options. Function Select Push Buttons. Used for setting DMX512 address and other configuration options (see next page). DMX512 Connector Pin-out: Pin Signal Name 1 Common (Shield) 2 Dimmer Drive - 3 Dimmer Drive + 4 Talkback - 5 Talkback + 6

S21 Dimmer Strip Up & Running Guide SETTING THE DMX512 ADDRESS Each S21 Dimmer Strip must have an unique DMX512 address. Addresses may be set in increments of three. The first valid address is 001. The second is 004. The third is 007, etc. Addresses must be set so that dimmer numbers do not overlap. If the unit at address 001 has six dimmers, then the next unit must be set to address 007. If the unit at address 007 has only three dimmers, then the next unit after it should be set to address 010. Unit addresses do not have to follow the order in which units are connected to the DMX cable. They simply need to be unique, and non-overlapping. The DMX512 address is set with the L, C, and R buttons and the display on the Head-End Processor. Step 1. Press the L button once. This places the display in the Display/Set Address mode (indicated by A in the left-most digit). The right three digits show the current address setting. Step 2. Press the C button to increase the address by three. Press the R button to decrease the address by three. Step 3. When the display shows the correct address, press the L button again. The address is now set. The display will blank after about one minute. The address is retained even when the power is off. The address may be changed at any time simply by following the above steps. 7

Up & Running Guide S21 Dimmer Strip DIMMER STRIPS AND ACCESSORIES S21 Dimmer Strips, 120 Volt: 71400 6 x 1200w 450ms S21 Dimmer Strip with GP connectors 71401 6 x 1200w 450ms S21 Dimmer Strip with GTL connectors 71402 6 x 1200w 450ms S21 Dimmer Strip with GR connectors 71403 3 x 2400w 800ms S21 Dimmer Strip with GP connectors 71404 3 x 2400w 800ms S21 Dimmer Strip with GTL connectors 71405 3 x 2400w 800ms S21 Dimmer Strip with GR connectors Accessories: 71430 2 ft AWG #10/5 power input cable with L21-20P GTL plug 71431 4 ft AWG #10/5 power input cable with L21-20P GTL plug 71432 6 ft AWG #10/5 power input cable with L21-20P GTL plug 71433 8 ft AWG #10/5 power input cable with L21-20P GTL plug 71434 12 ft AWG #10/5 power input cable with L21-20P GTL plug 71435 4 ft AWG #10/5 power extension cable with L21-20P GTL plugs 71436 6 ft AWG #10/5 power extension cable with L21-20P GTL plugs 71437 8 ft AWG #10/5 power extension cable with L21-20P GTL plugs 71438 12 ft AWG #10/5 power extension cable with L21-20P GTL plugs 82019 Pipe C-Clamp 71343 Cheeseboro clamp 71344 Wall Mount Bracket 71345 Network coupler - 5 pin turn female to female turnaround 71346 DMX Terminator 8

S21 Dimmer Strip Up & Running Guide TECHNICAL INFORMATION Number of dimmers: 6-1.2kW or 3 2.4kW dimmers Max output voltage: 115./120 volts Minimum load: 1watt Maximum load per dimmer: 1.2kW or 2.4kW Insert loss: Max 2.5 volts Power feed: 3-phase 4 wire 120/208 volts 20 amps; Terminal block or optional cord kits available Frequency: 50/60Hz Ambient temperature: 0-40 degrees C Humidity: 5%-95% Non condensing Cooling: Convection Height: 5" Depth: 3.5" (1.2kW strip) 4.25" (2.4kW strip) Length: 87" (1.2kW strip) 56.5" (2.4kW strip) Weight: 32lbs (1.2kW strip) 23lbs (2.4kW strip) Load Connector Types: GP Grounded Stage Pin GTL Twistlock GR Edison NEMA 5-20R 9

Up & Running Guide S21 Dimmer Strip MOUNTING HARDWARE Cheesbro Style Clamp: 71343 The 71343 Cheesbro Style Mounting Clamp is used to mount an S21 Dimmer Strip above either a 1½" schedule 40 pipe or a 2" aluminum tube (truss). The Cheesbro Style Clamp allows Dimmer Strips to be quickly relocated. (Two Cheesbro Style Clamps are required for each Dimmer Strip.) 10

S21 Dimmer Strip Up & Running Guide Single Pipe Hanger: 71347 The 71347 Single Pipe Hanger is used to suspend a single 1½" schedule 40 pipe and an S21 Dimmer Strip from a rigging system or a ceiling. (Single Pipe Hangers must be spaced to accommodate both the suspension of the pipe and the S21 Dimmer Strip.) 11

Up & Running Guide S21 Dimmer Strip Double Pipe Hanger: 71348 The 71348 Double Pipe Hanger is used to suspend two 1½" schedule 40 pipes and an S21 Dimmer Strip to a rigging system or a ceiling. The S21 Dimmer Strip is supported mid-way between the two battens. (Double Pipe Hangers must be spaced to accommodate both the suspension of the pipes and the S21 Dimmer Strip.) Wall Mount Hanger: 71349 The 71349 Wall Mount Hanger is used to permanently mount an S21 Dimmer Strip to a wall. (Two Wall Mount Hangers are required for each strip.) 12

S21 Dimmer Strip Up & Running Guide Ceiling Mount Hanger: 71350 The 71350 Ceiling Mount Hanger is used to permanently mount an S21 Dimmer Strip beneath a ceiling. (Two Ceiling Mount Hangers are required for each strip.) "C" Style Clamp: 82019 The 82019 "C" Style Mounting Clamp is used to mount S21 Dimmer Strips or Boxes beneath a 1½" schedule 40 pipe or a 2" aluminum tube (truss). This clamp style leaves the bottom unistrut mounting channel free to attach fixtures to the dimmer strip. The "C" Style Clamp allows Dimmer Strips to be quickly relocated. (Two "C" Style Clamps are required to mount an S21 Dimmer Strip or Box.) 13

Part No. 85-1567