ANDERSON, ECKSTEIN AND WESTRICK, INC.

Similar documents
City Hall 539 Phoenix Street South Haven, Michigan Telephone (269) Fax (269)

Review of Electric Utility Hurricane Preparedness and Restoration Actions ORLANDO UTILITIES COMMISSION RESPONSES TO STAFF'S SECOND DATA REQUEST

Guide. Services Document No: GD-1401 v1.0. Issue Date: Title: WIND ISLANDING. Previous Date: N/A. Author: Heather Andrew.

Pump Station 7 Improvements

MACOMB COUNTY DEPARTMENT OF ROADS TRAFFIC OPERATIONS CENTER

GCG ASSOCIATES, INC. PROFESSIONAL CIVIL ENGINEERS AND LAND SURVEYORS 84 Main Street Wilmington, Massachusetts 01887

DFO STATEMENT OF NEED REPORT

UNDERSTANDING ELECTRICAL EQUIPMENT AND CONDITIONS OF INCREASED RISK

of Fire Pump Assemblies

Appendix Technical Memorandum PS-1 on Pumping Stations Condition Assessment

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

INVESTIGATION REPORT PREPARED FOR: UNIVERSITY OF NORTHERN IOWA CEDAR FALLS, IA

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Building a 21 st Century Electric Grid. February 23, 2018

February 17, 2015 File:

Combustion Turbine Outages For 2008

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

CCHMP Comments on ConocoPhillips Incident Report For 10/22/10 Flaring Event

NORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS

University of Houston Master Construction Specifications Insert Project Name

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING

Storage and Dispensing Locations

Operating And Maintaining Underground Storage Tank Systems. Practical Help And Checklists. Printed on Recycled Paper

Operating And Maintaining Underground Storage Tank Systems. Practical Help And Checklists. Printed on Recycled Paper

Greater Ouachita Water Company. January 2016 Monthly Operations & Maintenance Report

ASTM D4169 Truck Profile Update Rationale Revision Date: September 22, 2016

D. Operation and Maintenance Data. In addition to items specified in Division 1 Section "Operation and Maintenance Data," include the following:

This letter summarizes our observations, anticipated traffic changes, and conclusions.

University of California, San Diego Cal (IT) 2 Technical Assignment #2. Brian Smith

SLUG CONTROL PLAN. Section A - Spills from Water-Using Process Areas

FLORIDA RURAL WATER ASSOCIATION 2970 Wellington Circle Tallahassee, FL Telephone: ~ Fax:

SPILL PREVENTION CONTROL AND COUNTERMEASURES PLAN (SPCCP) FOR FUELING AT STATION 63

100 MW Wind Generation Project

Substation inspection guidelines Mark B. Goff, P.E.

LESSONS LEARNED FORSMARK EVENT Presented To IEEEE

Interconnection Feasibility Study Report GIP-023-FEAS-R1. Generator Interconnection Request # MW Wind Generating Facility Inverness (L6549), NS

Rural Water Supply Operations Seminar & Drill

Internal Audit Report. Fuel Consumption Oversight and Coordination TxDOT Internal Audit Division

ARKANSAS DEPARTMENT OF ENVIRONMENTAL QUALITY STATE INDUSTRIAL PERMIT INSPECTION FORM. Permit No.: 4369-WR-1 Inspection Date: September 7,2006

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM

Section 5 - Operations and Maintenance Program

Analysis of Impact of Mass Implementation of DER. Richard Fowler Adam Toth, PE Jeff Mueller, PE

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

Program Guide: Medford Residential Recycling and Trash Program

Hydro Plant Risk Assessment Guide

City of Alpena Septage Receiving Facility Operating Plan

PETROLEUM PRODUCT STORAGE TANK REGULATION SAFETY AND BUILDINGS DIVISION BUREAU OF PETROLEUM INSPECTION AND FIRE PROTECTION

Anderson, Eckstein and Westrick, Inc.

Modify Section by adding subsection.02 per the following. Remainder of section is unchanged.

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Life cycle services for protection and control relays Full support from start to finish

Specifications of STICKTITE and PILOTPAK Nozzles

Alfred & Plantagenet Multi-Residential Cart Recycling Program CIF Project Number # Final Report October 1, 2016

Sub Regional RTEP Committee Mid-Atlantic

Specifications of STICKTITE and PILOTPAK Nozzles

Bypass Pumping Brian Lee Municipal Sales Rev Bypass Pumping

City of Grand Island Tuesday, October 10, 2017 Council Session

charging station installation in multi-family building

Leaks of fuel oil and pollution of waterway / Pollution of the site 22 August and 13 December, 2002 Brussels [Brabant] Belgium

Health and Safety Executive, Technology and Health Sciences Division, Magdalen House, Bootle.

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Electrical Existing Conditions and Building Load Summary Report

Columbus Collection and Treatment System Real Time Wet Weather Operational Implementation

Todd Carlson Program Coordinator Engineering MMSD PP I/I Summit 2.0 October 15,

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Sub Regional RTEP Committee Mid-Atlantic

A Cost Benefit Analysis of Faster Transmission System Protection Schemes and Ground Grid Design

TORONTO TRANSIT COMMISSION REPORT NO.

There was an excessive accumulation of grease in the 820 Pump Station.

THE CURVE FOR DOUBLE PROTECTION TRANSFORMER & SYSTEM PROTECTION WITH CHANCE SLOFAST FUSE LINKS

ELECTRICAL. 60 Minutes

CHARLES RIVER POLLUTION CONTROL DISTRICT. Requirements for Septage Receiving

B. HOLMQVIST Nuclear Fuel Division, ABB Atom AB, Vasteras, Sweden

Pipe & Re-Pipe A Perspective from Florida. R. Steven Miller Project Manager Downstream Data Corporation

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Water Treatment Plant Historical Timeline

E-15 Uninterruptible Power Systems (UPS)

IEEE Guide for the Design of Low Voltage AC and DC Auxiliary Systems for Substations

Downtown Lee s Summit Parking Study

UNITED STATES DEPARTMENT OF LABOR MINE SAFETY AND HEALTH ADMINISTRATION Metal and Nonmetal Mine Safety and Health REPORT OF INVESTIGATION

Generator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood

Joslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers

PHMSA Office of Pipeline Safety Dave Mulligan Western Region

Grounding Of Standby & Emergency Power Systems

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

SPP Notification to Construct

Late Starter. Tuesday, November 6, 2018

TRANSMISSION SYSTEMS

Guideline for Parallel Grid Exit Point Connection 28/10/2010

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

City of Peachtree City

Product Emission Recall Incorrect Catalytic Converter

The table below provides information on the five vacuum pump-out units evaluated in this study.

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

ARC-ALERT CIRCUIT INTERRUPTER TECHNOLOGY NEXT GENERATION OF CIRCUIT PROTECTION

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

Township of Lincoln (Clare County) P.O. Box 239 Lake George, Michigan phone: [989] website:

Transcription:

ANDERSON, ECKSTEIN AND WESTRICK, INC. 51301 Schoenherr Civil Engineers Road, Shelby Township, Michigan 48315 Surveyors Architects 586-726-1234 Mr. Matthew Tepper City of Grosse Pointe Farms 90 Kerby Road Grosse Pointe Farms, Michigan 48236-9984 Reference: Kerby Road Pump Station City of Grosse Pointe Farms^ AEW Project No. 0156-0009 Dear Mr. Tepper: The City of Grosse Pointe Farms (GPF) requested that Anderson, Eckstein and Westrick, Inc. (AEW) provide GPF's a cursory review of the pump station equipment and design. This review was to include the identification of any noticeable deficiencies and a conclusion as to the condition of the pump station. On Friday, September 23, 2011, James Rabine, P.E., William Edwards, P.E. and I visited the Kerby Road Pump Station. Mr. Dan Ch answer questions and provide us with a findings are as follows: Summary of Existing Pump Station uvin and you were present during our visit to tour of the pump station. A summary of our Based upon information obtained from r. Chauvin and our review of the construction plans, it is our understanding that the orig nal pump station was constructed in 1930 and included six pumps as follows: Pump Number 1 [ 2 3 4 5 6 Capacity (Gallons per minute) 2000 2000 5400 10,800 33,750 45,000 Fax 586-726-8780 Engineering Strong Communities www.aewinc.com

October 3, 2011 Page 2 In 1947/48, an addition was constructed on the west side of the building to facilitate two additional pumps as follows: Pump Number Capacity (Gallons per minute) 75,000 8 75,000 In 1994, upgrades were made to the control panel and bubbler system. Based upon our discussions with Mr. Chauvin and yourself, it is our understanding that this pump station handles all of the combined sewer flow in GPF west of Ridge Road along with the entire sanitary sewer flow from the city. Please note that this review did not include a review of the sewer systems that feed the pump station. Based upon the original construction plans, two combined sewer lines (one 6'-6" diameter and one 6'-0" diameter) discharge into the pump station. All of the pumps discharge into an outlet chamber located on the south side of the pump station which then, in turn, discharges into the Fox Creek through an 11'-6" x 16'-6" Arch pipe. The primary control is based on wet well elevation. The deeper the water in the wet well, the more pumps and larger capacity pumps are activated. It was raining during our visit and pumps 1 through 3 where running under normal operations. In an effort to run all pumps, Mr. Chauvin shut off all pumps and allowed the wet well to fill up enough to individually nun the remainder of the pumps (4 through 8). Due to low flow volumes, the pumps were only run for very short durations. All pumps seemed to run smoothly and no unusual vibrations were detected while the pumps were running. Some minor brush noise and arcing were noticed on the motor for pump 6 which can be corrected with minor adjustments. We also noticed a significant leak in the packing on pump 3 which should also be repaired. Existing Electrical System The pumping station is currently serviced from a Detroit Edison substation that provides two 4800V lines from two different transformers. This information was confirmed by Lee Southworth of DECO Primary Services. Both lines are active at all times and provide the normal power to the pumping station. In addition, a permanent generator, ownfed by NEXTEL, is connected to the pumping station that supplies emergency power to {the DPW Department, pumping station control systems and pumps 1, 2, and 3 in the eveht of a power interruption.

October 3, 2011 PageS During our visit, we simulated power loss, tripping the circuit breakers and verified each of the breakers and sequencing operated properly. Line 32T was interrupted and the station tie breaker closed, transferring the loads over to the second incoming line 191T and started the generator to power all control functions. This operated properly. The 32T line was restored and line 191T was interrupted, again the tie breaker closed transferring the loads to line 32T. The generator does not come on when line 191T is lost because the controls are powered from the line 32T side. The switchgear for the substation was installed in 1994 and is in good physical condition and was being tested while we were on-site. The breaker testing is scheduled for October 17 through 19, 2011. All of the pump motor starters are older than the switchgear and do not appear to have been tested recently. The starters for pumps 5, 6, 7, and 8 do not get much use, but should be maintained on a regular schedule. The pump motors are old but very well constructed, and should serve for many more years, if maintained. Section 47.2 of the Recommended Standards for Waste Water Facilities (10 State Standards) require that "Emergency pumping capability shall be accomplished by connection of the station to at least two independent utility substations, or by provision of portable or in-place internal combustion engine equipment which will generate electrical or mechanical energy, or by the provision of portable pumping equipment." These standards further state that "Such emergency standby systems shall have sufficient capacity to start up and maintain the total rated running capacity of the station." It is our understanding, based upon a phone conversation with Lee Southworth of DECO Primary Services, that the 2-4800v feeds to the pump station come from different transformers at the same substation. This does not meet the power redundancy requirements however it is our understanding that a permanent adjacent Nextel generator provides backup power for the dry weather pumps (pumps 1 thru 3), lights and control systems; a rental generator was recently installed to provide backup power for the 3 mid range pumps and the city is in the process of connecting a portable generator to provide backup power to the 2-75,000 gpm pumps. The DWSD billing meter is currently not functioning. It is our understanding that the Greater Detroit Regional Sanitary Sewer (GDRSS) Flow Metering Task Force has inspected the meter and has determined that the meter will need to be replaced.

Page 4 Summary of Recommendations During the inspection, a few recommendations were identified by the team. They include: 1. Develop and implement a permanent backup power source that meets the requirements of Section 47.2 of the Recommended Standards for Waste Water Facilities (10 State Standards). 2. Develop a Standard Operation Procedure (SOP) to manually run the mid range pumps as soon as the stable flow depth permits, turning off smaller pumps to balance the flow requirements in an attempt to draw down water levels in the incoming pipes. This will maximize available in line storage in the event that the storm surge has not yet been received. This SOP will reduce the potential for sanitary sewer overflows (SSOs) and basement flooding, while increasing the run time on the larger pumps and slightly reducing run times on the smaller pumps. 3. When any major control upgrades are made, integrate the above SOP into the automated system with logic to balance power consumption efficiency and in line storage capacity. 4. Pump 7 and 8 are currently served from one breaker in the switchgear. They should be separated with a breaker for each. There is a spare breaker in the adjacent cabinet that could be used for this purpose. This would also require an additional DC control package because the two pumps currently share one DC source for control. 5. When Pumps 7 and 8 were designed, it was decided to build an overflow weir to feed a second wet well sump. While that was likely less expensive than extending the wet well, it limits the available flow to these pumps. The potential to extend the wet well, or to connect the two sumps with large capacity pipe, should be investigated. 6. A wood ladder with some planks was noted in the wet well. It appears to be used as a catwalk to service the lights in the facility. This represents a MIOSHA violation and should be replaced with a permanent structural fiberglass or steel catwalk with proper railings to service the lights and any other equipment requiring access. 7. While the level of general maintenance is better than most facilities, the interior of the building could use wall cleaning and painting. 8. Roof repair should proceed as soon as possible to prevent a water leak above the open pump motors on the floor. 9. The pump motor starters did not appear to have been tested recently. Since the starters for pumps 5, 6, 7 and 8 do not get much use, they should be tested regularly to insure reliability.

Page 5 10.The brushes on the motor from pump 6 should be adjusted. 11.The bearings on pump 3 should be repacked to eliminate the leaking that is occurring. 12.The one line electrical drawing should be updated showing the NEXTEL generator and the current connections, transfer switch and sequence of operation. A copy should be posted in the switchgear room. 13. Follow up with DWSD to repair or replace their billing meter. If the Michigan Department of Environmental Quality becomes aware of its condition, they will also strongly encourage the repairs on an expedited basis. 14. Evaluate and possibly install secondary meters on all the pumps. These nonbilling meters can be correlated (calibrated) to the billing meter over time. That will allow monitoring of each pumps output during operation and detect loss of capacity through wear. Future rehabilitation needs can be anticipated and scheduled. Once calibrated the secondary meter data may be useful in billing DWSD disputes. While the facility is quite old, the equipment and facility appear to be well maintained and runs well. A review of the O&M records was not completed but could be if a more thorough investigation is required. The motors and electrical equipment were built to higher standards than today and the use of lower voltage on the primary pump units and starters assures their long life. The original facility and equipment were well designed for their intended permanent use. Sincerely, rpnen v./pangori; PE Executive Vice President O:\0156\0156-0009\Letters\AEW_GPFPumpStationReviewR1 (2).docx