Test Stations and Pipe-to-Soil Potential Measurements

Similar documents
DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Environmental Cleanup and Brownfields

WYOMING STORAGE TANK PROGRAM GALVANIC (SACRIFICIAL ANODE) CATHODIC PROTECTION SYSTEM EVALUATION

Cathodic Protection for AST s. Why is Cathodic Protection Important?

Cathodic Protection Guidance? Who needs that? Aren t t NACE & STI enough? David Robinett Virginia Dept. of Environmental Quality

GUIDELINES FOR THE EVALUATION OF UNDERGROUND STORAGE TANK CATHODIC PROTECTION SYSTEMS

This article discusses a tank

GUIDELINES FOR THE EVALUATION OF UNDERGROUND STORAGE TANK CATHODIC PROTECTION SYSTEMS

FINAL REPORT CATHODIC PROTECTION EVALUATION. 42-Inch Water Transmission Pipeline Contract 1 Station 0+00 to South Texas Water Authority

Monitoring Cathodic Protection of Natural Gas Pipelines

Asset Protection Cathodic Protection Testing of Insulating Joints. Work Instruction No.:

An Introduction to Constructing and Maintaining Cathodic Protection Systems

PREVENTION OF STRAY CURRENT BY THE MAINTENANCE-OF-WAY

PIPELINE CORROSION CONTROL

The Gradient Control Mat (GCM)

B3-D MULTI-METER MANUAL (Catalog # 1106)

Cable-Tight Wire Management System

CELLS AND BATTERIES Understand the general features of cells and batteries Describe the relationship between cells and batteries. Describe the basic

BURGLAR ALARM KIT MODEL K-23. Assembly and Instruction Manual ELENCO

7. Protection System Testing

LAB 7. SERIES AND PARALLEL RESISTORS

National Fire Protection Association

Measuring Voltage and Current

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House

Standard Recommended Practice. Corrosion Control of Underground Storage Tank Systems by Cathodic Protection

Important Information

Corrosion Prevention and Maintenance

The Knowledge Bank at The Ohio State University. Ohio State Engineer. Electrolysis in Underground Structures

OPERATING MANUAL MODEL B3-D

TECHNICAL NOTE #4 Revised May 24, BOGART ENGINEERING Two Bar Road, Boulder Creek, CA (831)

Chapter 28. Direct Current Circuits

Exercise 2: Series-Opposing DC Sources

Model B3-A2 Manual. Catalog # 908

METHOD OF TEST FOR DETERMINATION OF CATHODIC DISBONDMENT OF EPOXY-COATED REINFORCING BARS

UNIT 6: BATTERIES, UPS AND CABLES

CP-1TT Remote System

BASIC ELECTRICAL MEASUREMENTS By David Navone

ELECTRICAL. CDTA Technical Training Center

A device that measures the current in a circuit. It is always connected in SERIES to the device through which it is measuring current.

Symptom Corrective Action. Wrong polarity of cell, block, row of battery. Interruption at connector. Interruption due to empty cell.

Designed with potential in mind

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Fact Sheet #4 Reducing the Risk of Groundwater Contamination by Improving Petroleum Product Storage

INSTRUCTION MANUAL DM5B Fax: (503)

HOW IS ELECTRICITY PRODUCED?

Feasibility of Applying Cathodic Protection to Underground Corrugated Steel Pipe

EXPERIMENT 13 QUALITATIVE STUDY OF INDUCED EMF

7. UST Piping Corrosion Protection. NCDENR Division of Waste Management Underground Storage Tank Section

CHASSIS TECH TIPS. Subject: VOLTAGE DROP TEST

V=I R P=V I P=I 2 R. E=P t V 2 R

Introduction to Electricity & Electrical Current

Electricity. Chapter 20

IT 0335 US ARMY INTELLIGENCE CENTER INTRODUCTION TO CELLS AND BATTERIES

IT 0335 US ARMY INTELLIGENCE CENTER INTRODUCTION TO CELLS AND BATTERIES

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

RICHLAND COLLEGE School of Engineering Business & Technology Rev. 0 W. Slonecker Rev. 1 (8/26/2012) J. Bradbury

WSB clean: Installation Manual

Rosemount 8750WB Magnetic Flowmeter System

CONTENTS. Foreword...iii. 1. Introduction...1


METEOROLOGICAL INSTRUMENTS

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ

METEOROLOGICAL INSTRUMENTS

OD DISSOLVED OXYGEN METER

DC Series Motors by Thomas E. Kissell Industrial Electronics, Second Edition, Prentice Hall PTR

Earthing UNIT. Learning Objectives. Introduction. To understand purpose of Earthing. To learn system of earthing.

AERL CoolPro CP User's Manual

SlimLine (TM) Reduced Diameter Reference Electrode

Electricity MR. BANKS 8 TH GRADE SCIENCE

An unwritten rule says that when a. Cures for a sick spot welding machine. Figure 1. To test the secondary of the welding machine,

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.

Unit 10 Measuring Instruments

Electrical Systems. Introduction

Owner s Manual. Contents GP-PWM-10-SQ

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

Electricity and Magnetism

Electrical Fundamentals Ed Abdo

Alternating Current (AC) Electricity

Hydro-Flow Model 3100

ENERGIZING WITH VOLTAIC BATTERIES

INSTALLATION & MAINTENANCE MANUAL HI LPD SERIES LOAD POINT ASSEMBLY Calle Fortunada San Diego, CA

Holiday Detector. Model EPT/AC-30 High Voltage Coating Test Instrument Brief Description

California Friendly Landscape Training

AD592/592-10K Non-Room Units with a Junction Box, Weatherproof (WP) or Weather Tight (EU) Enclosure

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation

XP800i POWER INVERTER OWNER S MANUAL

Duracell Battery Glossary

Grounding Systems. Equipment Grounding & Grounded Conductors

Air Washington Electronics Direct Current

SC10F Circuits Lab Name:

GLOSSARY: TECHNICAL BATTERY TERMS

Electromagnetic Induction (approx. 1.5 h) (11/9/15)

Goals. Introduction (4.1) R = V I

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Autoranging Industrial Multimeter

11.1 CURRENT ELECTRICITY. Electrochemical Cells (the energy source) pg Wet Cell. Dry Cell. Positive. Terminal. Negative.

Hot-Shot Operating Instructions

PIPELINE. catalogue. Pipeline construc on and maintenance Products & Solu ons

Electricity 1

QUASAR KIT No THYRISTOR - TRIAC TESTER

MultiCal. Operation Manual for MultiCal mmhga/psia Pressure Module

Transcription:

Test Stations and Pipe-to-Soil Potential Measurements Period #7 Practical Applications Course 2017 Mark James NACE CP II #5619, NACE CIP I #37041 1

Introduction Test Stations Wire Connection to Pipe Pipe-to-Soil (P/S) Potential Measurements Criteria of Cathodic Protection (CP) Page 2

Test Stations Above Grade Preferred but many for ease of locating and access Preventing damage to wires Condulet Type Lexan Plastic posts Terminal Blocks Occasionally damaged by traffic or hunters Page 3

Test Stations At Grade Similar to curb boxes Wires coiled some with terminal blocks Better for esthetics Easily lost or damaged Need accurate measurements Page 4

Color Coding Wires Color codes help identify what each wire is connected (Follow company standards) Improves future monitoring by adding quick identification of the wire to test Technicians aren t happy when the standard is not followed Page 5

Connecting Wires Thermit Welding Surface preparation Prepare the wire(s) Prepare the welder mold Make sure the mold is dry Making the connection Correctly identify the connection by following the color code Page 6

Safety While Thermite Welding Pipe surface must be clean and dry Welder Mold must be dry The atmosphere is gas free Wear the proper PPE Glasses Gloves Boots Page 7

Prevent Backfill Damage to Wires Backfill settles after construction Leave extra wire coiled in test station (about two feet) Careful not to damage the wires with shovels or equipment Page 8

Test Station Usage Standard Test Stations Galvanic Anode Test Stations Buried Isolation Joint Test Station Foreign Line Crossing Current Flow Test Station Buried Reference Electrodes Page 9

Standard Test Station Two Wires Inexpensive If one fails you have a second Future testing Page 10

Galvanic Anode Test Station Sacrificial Anode(s) attached through a test station Three wires usually attached to the pipe Two serve as test wires One used to connect anode at terminal block Shunt can be installed to measure current output Page 11

Buried Isolation Joint Two wires attached to each side of a buried isolation joint Follow color code Used to test the effectiveness of the isolation joint Page 12

Foreign Line Crossing Test leads are attached to another pipeline or facility on which you are not working Three wires attached to each pipeline Note: Do not attach wires to another company s facility without their approval and representative present Follow color code Page 13

Current Flow Test Station Used on transmission lines to measure direction and magnitude of current flow Also called IR Drop Test Stations Used to evaluate coating condition and CP effectiveness Page 14

Buried Reference Electrode Test Station Buried reference electrode attached through the test station Can be placed close to the pipe allowing for a more accurate reading Must be inspected periodically to validate calibration Page 15

Pipe-to-Soil Potential Measurements Volt Meters (multimeters) Lead Wires Reference Electrodes Placement of Electrode Electrolyte Contact Sign Convention Page 16

Pipe-To-Soil Measurements Used to determine the effectiveness of CP Locate stray current Check for shorts. Electrical isolation, electrical continuity Taken with CP ON Off Cycling Native State Page 17

Components to take a P/S Reading Volt Meter Lead Wires Reference Electrodes Electrolyte Pipeline or Structure Page 18

Voltmeters Available in various types Digital Numerical read-out Analog (D Arsonval movement) Moving needle Computerized Data Logger Computer chip stores the readings Can collect other data GPS Must be high input resistance (10 megohoms or more) See next slide for examples of voltmeters Page 19

Common Voltmeters used for CP Page 20

Lead Wires Connections Secure To the Structure Low Resistance Tight Connections Loose connections High Resistance Unstable or incorrect reading Contact point Clean Electrically continuous Page 21

Lab 9 Poor Test Lead Connection Connect test lead to the coated riser of the coated pipe and take P/S Reading Compare that reading to a good reading Page 22

Reference Electrodes (half cells) Two Common Types Copper Sulfate Silver-Silver Chloride Temperature sensitive Contaminant free Saturated solution Reference electrodes are also called half-cells: form one-half of an electrical cell pipeline being the other half of the cell Page 23

Copper Sulfate Reference Electrode Come in various sizes and types Most commonly used for pipeline work Temperature sensitive Do not leave in direct sunlight for long periods of time or subjected to high temperatures cover it from direct sunlight overheating will cause a voltage shift in the potential readings may cause it to leak or become unsaturated Page 24

Half Cells 2A Pencil 8A Flat Tip 6A Flat Tip 6B Pointed Tip 8B Pointed Tip 3A Flat Bottom W7 Waterproof connector DBA Direct burial Page 25

Silver-Silver Chloride Reference Electrodes Silver-silver chloride (AgAgCl) Used in salt water AgAgCl electrodes are used for testing submerged pipelines and other structures Page 26

Placement of Electrodes Important for accurate readings Directly over the pipeline The closer the better Good electrolyte contact Do not place the electrode over an anode get readings in between anodes whenever possible don t take readings directly at test stations that have an anode connected through them do not place the electrode near the anode when testing service lines that have anodes attached to them get the reading somewhat remote from the anode readings over an anode will yield an erroneous reading because of the voltage (IR) drop Close to the pipeline as possible without touching it Page 27

Lab 10 Placement of Reference Electrode Connect magnesium anode to coated pipe Take P/S reading with reference cell placed at opposite end of the coating holiday (coating flaw) Move reference cell by the coating holiday and take P/S Page 28

Good Electrolyte Contact Good contact between the half-cell and the electrolyte Wetting the electrolyte with water can help improve contact A wet sponge can also be used The Fat Boy electrode Issues with taking readings through concrete or asphalt surfaces Get the tip through the top layers of the soil for better contact. Good contact; potential readings will settle down Gravel or stones may have to scrape away a couple of inches to get to the soil underneath may need to install a tube through the stone to get to the soil Landscaping may have plastic for drainage or architectural effects with mulch or stone puncture the plastic and get the electrode down to the soil or use a tube to get through the plastic Page 29

Lab 11 Electrolyte Contact 1. Take the paper cup and fill it with water (simulates poor contact with electrolyte) 2. Place the paper cup in the tub 3. Take the P/S reading by placing the half-cell in the cup 4. Take P/S reading by placing half-cell in the tub Page 30

Sign Convention Voltmeter (-) Lug Voltmeter (+) Lug Sign Convention Pipeline Electrode 0.850 Electrode Pipeline -0.850 Page 31

Sign Convention (continued) Pipeline connected to the voltmeter (-) and your half-cell is connected to the voltmeter (+), the value would read +VDC Pipeline connected to the voltmeter (+) and your half cell is connected to the voltmeter (-) the value would be -0.850 VDC. Either case is correct Must track the polarity Page 32

Sign Convention (continued) P/S readings are considered negative relative to the reference electrode common cathodic protection criterion for a steel pipeline is - 0.850 VDC referenced to CS depending on your requirements, equipment and preference, your meter can read a -0.850 VDC or +0.850 Volts DC The reason why pipe-to-soil potentials are considered negative Measurements are made to the CSE Referring back to Table 1-1, note that there is a zero point when metal potentials are measured with reference to copper Some metals are more negative than copper and some more positive Page 33

Sign Convention (continued) With underground structures negative to earth when it is picking up current positive to earth when discharging current structure potential increases when CP is applied it is negative to earth; said to increase negatively common galvanic anode materials; the potential of the steel becomes more negative Most corrosion personnel connect digital voltmeters (+) to the pipeline and (-) to the CSE so that the meter shows a (-) reading Page 34

Criteria of Cathodic Protection There are several criteria Two most common Pipe-to-Soil Potential of at least -0.85 Volts With Respect to a Copper-Copper Sulfate Reference Electrode Measured with Cathodic Protection Applied Measured with Cathodic Protection Off 100mV (0.1) Volts Polarization Page 35

Effect of Voltage (IR) Drop Ohm s Law defines the relationship among the three electrical quantities, voltage (E), current (I) and Resistance (R). Ohm s Law states that voltage equals current times resistance, or E=IxR. Voltage is frequently referred to as simply IR. A voltage drop occurs whenever a current passes through a resistance The earth has resistance Place the reference cell close to the pipe The voltage at the location of the electrode will be more negative than that at the location of the pipe an erroneous reading, more negative than that the voltage at the pipeline cathodic protection criteria require that the IR drop be considered in the reading; taking steps to obtain the most accurate, IR drop free data Page 36

-0.85 V With Respect to a Copper- Copper Sulfate Reference Electrode Commonly used criterion Applicable to steel and cast/ductile iron Useful on coated pipelines because of the relatively small current required to protect them Bare pipelines may require excessive current to polarize them up to this potential There are two versions of this criterion. Page 37

Measured with Cathodic Protection Applied Applicable to pipelines that have galvanic anodes connected directly to them No way of disconnecting or interrupting the protective current Consider IR Drop Page 38

Measured with Cathodic Protection Off Pipe-to-soil potential measurements taken with the cathodic protection current momentarily interrupted, or turned off Usually easy to accomplish with impressed current systems Interrupters Also be done when galvanic systems are connected to the structure through a test station When the cathodic protection is off, there is no current flow in the earth and thus no IR drop (since voltage drop [E] = IxR [Ohm s Law], if I=0, E must = 0) These off readings are accurate measurements of the actual structure-to-soil potential Page 39

100mV (0.1) Volts Polarization Applicable to steel and cast/ductile iron as well as aluminum and copper Useful for steel structures that are poorly coated or bare and which would require an excessive amount of protective current to meet one of the -0.850V criteria frequently used for well casings The 100mV (0.1V) polarization refers to the difference between 1) the original, unprotected potential and the off potential after cathodic protection has been installed or: 2) the difference between the instant off potential and a potential reached after a period of depolarization Page 40

Lab 12 CP Applied Instant Off 1. Take P/S reading with magnesium anode attached to coated steel 2. Disconnect anode and note instant off reading 3. Polarization- Continue to observe the P/S reading as it decays 1. After 30 seconds 2. After one minute Did you achieve the 100 mv shift? Page 41

Summary Test Stations Wire Connection to Pipe Pipe-to-Soil (P/S) Potential Measurements Criteria of Cathodic Protection (CP) Page 42

Questions Page 43