Press Industry Solutions

Similar documents
Press Industry Solutions

Control Reliable Double Valves with Total Dynamic Monitoring & Complete Memory

BULLETIN. Manufacturers of Premium Pneumatic Controls since 1921

ROSS CONTROLS. Double Valves for Clutch/Brake Control

ROSS CONTROLS. Double Valves for Control Reliable Energy Isolation.

ROSS CONTROLS. Double Valves for Control Reliable Energy Isolation.

Control Reliable Monitored Valves

CONTROLS SAFETY EXHAUST (DUMP) CONTROL RELIABLE ENERGY ISOLATION DOUBLE VALVES M35, DM 1, DM 2 SERIES.

Spool & Sleeve Valves for ANSI Sub-Bases Series W70

CONTROLS ROSS SAFETY-RELATED PRODUCTS

ROSS CONTROLS. Double Valves for Clutch/Brake Control.

ROSS CONTROLS. Base Mounted Valves. and Serial Bus Communication

Product Information. Safety Exhaust ROSS CONTROLS

DM 2 Series D 3/2 Double Valves

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

Product Information. 80 Series ROSS CONTROLS

FRL/AirCare Air Controls & Accessories

Product Information. Safety Exhaust ROSS CONTROLS

DIGEST CATALOG 104. Manufacturers of Premium Pneumatic Controls since 1921

Product Information ROSS CONTROLS

CONTROLS ROSS SAFETY-RELATED PRODUCTS

Poppet Valves for Line Mounting and Valves for Vacuum Service

DM2 Series D 3/2 Double Valves

Pneumatic Machine Safeguarding Solutions

Product Information ROSS CONTROLS

Product Information. L-O-X 15 Series ROSS CONTROLS

BULLETIN 510. The Guiding Light to Pneumatic Machine Safeguarding. Complete Your System with ROSS CONTROLS Safety-Related Products.

ROSS CONTROLS.

Valves and Manifolds for ANSI Bases

Product Information ROSS CONTROLS

F20 & F21 QIX Particulate & Coalescing Filters

ISO & Valves

Product Information. Safety Exhaust. DM 2 Series C ROSS CONTROLS

ROSS CONTROLS. Explosion Proof Valves 27 & 21 Series, DM 2 Series C. ISO Valves W60 & W64 Series.

ROSS CONTROLS. CrossMirror 77 And CM Series. Double Valves for Cylinder Return to Home Position.

Compact Valves 16 Series

Product Information. RSe Series ROSS CONTROLS

Clutch/Brake Control Monitored Double Valves

ROSS CONTROLS.

Product Information. 16 Series ROSS CONTROLS

Solenoid pilot operated spring return inline valves with nonlocking overrides, 120V, 60 Hz, and cablegrip connector

CONTROLS MINIATURE VALVES W14 SERIES SOLENOID PILOT PACK VALVES SERIES.

Model Model 815

Flow Controls & Accessories

AIR LINE LUBRICATORS

High Pressure Coolant Valve

Product Information. 36 & RM Series ROSS CONTROLS

Booster Pump Control Valve

Safe Cylinder Control and Stop and Load Holding Valves ROSS CONTROLS

ROSS CONTROLS. Compact Valves 16 Series.

ROSS CONTROLS. ISO & Valves W66 Series.

503 Series Solenoid Pilot Actuated Valves

CONTROLS VALVES FOR AIR FLOW CONTROL

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

Product Information. Stainless Steel. L-O-X 15 Series ROSS CONTROLS

ROSS CONTROLS.

Your Global Source for Today s Most Popular Solenoid Valves

4 Port Solenoid Valve

Manufacturers of Premium Pneumatic Controls since 1921 ROSS CONTROLS ROSS CONTROLS ROSS CONTROLS

ValVes for air flow Control

Product Information. 11,12, 31, 36, Pendant Series ROSS CONTROLS

4 Port Solenoid Valve

Soft Start-up Valve. AV2000/3000/4000/5000 Series

ROSS CONTROLS.

Hazardous Locations ROSS CONTROLS

ROSS CONTROLS. Manual and Mechanical Valves

Housings and Miscellaneous Parts

VAL /4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves. Solenoid pilot operated spring return inline valves with nonlocking

Electronic Temperature Control & Bulb Well Assembly (AC)

ROSS CONTROLS. Manual and Mechanical Valves

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

Product Information. W66 Series ROSS CONTROLS

Product Information ROSS CONTROLS

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description

Flow Controls & Accessories

CONTROLS MANUAL AND MECHANICAL VALVES

Exclusively for air pressure system and air-hydro circuit control

Manual and Mechanical Valves

Modulating Water Valves and Bulb Wells

MIS SERIES. Mist Eliminator. Installed differential pressure gauge and optional zero air-loss drain valve. Air or Water Cooled Aftercooler

Center Center Exhaust Pressurized PS-32AS PS-32BS PS-32AD PS-32BD PS-520S PS-520D PS-53CD PS-53ED PS-53PD. Series PS. Function

P64F - Olympian Plus plug-in system Soft start/dump valves

5 Port Solenoid Valve

501 SERIES. 501 Series Directional Control Valve Platform. Featuring Higher Flow in a Compact Valve Package. Commissioning Capabilities

ROSS CONTROLS. 95 Series. Inline Directional Control Valves.

Air Valve AIR-PILOTED VALVES

Directional Control Valves ROSS CONTROLS

PROCESS & AUTOMATED VALVES

Heat Exchanger Accessories

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S

3 Port 3 Position Valve

CONTROL VALVES W910 Series

5 Port Solenoid Valve

5 Port Solenoid Valve

Flow Controls & Accessories

QBV SERIES Butterfly Valves

hydraulic power clamps

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

Transcription:

Press Industry Solutions Lösungen für die Pressenindustrie プレス インダストリー ソリューション ncko m e lek/kku Soluções para Prensas 锻压工业解决方案 ULLETIN 450 Manufacturers of Premium Pneumatic ontrols since 1921

Pneumatic Press pplications DUMP LOW DOWN FILL MN - UTO OUNTERLNE DIE USHION TO ROLLING OLSTER UTO 1 UX. OUTLET DIE LMPING UTO 2 MEHNIL DEVIES IR PREP. & LOKOUT FLYWHEEL RKE MIN IR DISTRIUTION LUTH/RKE DOULE VLVE TO LUTH & RKE 2 2009, ROSS ONTROLS. ll Rights Reserved.

Table of ontents Main ir Entry Zentrale Lufteinspeisung メインエアーエントリー eq[; gok izos k Entrada Principal de r 主进气口 ir Distribution Luftverteilung エアーディストリビューション gok forj.k Distribuição de r 气流分配 utomatic Systems utomatische Systeme 自動化システム Lopkfyr iz.kkfy;kw Sistemas utomáticos 自动系统 utomation Valves utomatisierungsventile オートメーションバルブ Lopkfyr okyo Válvulas para utomação 自动化阀门 lutch/rake Kupplung/remse クラッチ / ブレーキ Iaktk@ xfrjks/kd Embreagem/Freio 离合器 / 制动器 ccessories Zubehör アクセサリー Lkgk;d midj.k cessórios 辅助配件 autions/warranty High apacity Filters (pg. 4) High apacity Regulators (pg. 5) L-O-X Valves (pg. 6-7) Standard Size 12-3/4 Port (pg. 8) Standard Size 20-1 Ports (pg. 9) Economy Size 8 & 12-1/2 to 3/4 Ports (pg. 10-12) ounterbalance (pg. 13-14) Die ushion (pg. 15) Die lamping (pg. 15) Flywheel rake Mechanical Devices (pg. 16) Part Ejection DM 2 Double Valves (pg. 17-19) SERPR Double Valves (pg. 20-21) rossflow Double Valves (pg. 22) 5/2 rossmirror Double Valves (pg. 23) heck Valves, Silencers (pg. 24) all Valves, Gauges, Pressure Switches, Transducers, etc. (pg. 25-26) (pg. 27) www.rosscontrols.com 3

Ports: 3/4 & 1 Flow to 275 scfm High-apacity Filters Filter フィルター Nyfu;kW Filtros 过滤器 Ports: 11/4, 11/2, & 2 Flow to 1000 scfm FETURES: Inline mounting. High-strength polycarbonate plastic filter bowl with steel shatterguard; optional metal bowl with clear nylon sight glass. Internal automatic drain; optional manual drain or external automatic drain. NPTF port threads; optional SE or SPP threads. ISO Filter Symbols Manual Drain utomatic Drain Port* ir Flow owl utomatic Manual Size scfm (l/s) Material Drain Drain Depth lb (kg) 3/4 250 (120) Plastic 50215008 50115008 4.5 (114) 8.0 (203) 0.8 (21) 4.2 (106) 2.44 (1.11) 3/4 250 (120) Metal 50225005 50125006 4.5 (114) 8.3 (210) 0.8 (21) 4.2 (106) 3.25 (1.48) 1 275 (130) Plastic 50216008 50116008 4.5 (114) 8.0 (203) 0.8 (21) 4.2 (106) 2.44 (1.11) 1 275 (130) Metal 50226005 50126006 4.5 (114) 8.3 (210) 0.8 (21) 4.2 (106) 3.25 (1.48) 11/4 700 (330) Metal 5X007025 5X007054 8.0 (203) 13.3 (337) 1.8 (45) 7.3 (186) 14.3 (6.59) 11/2 770 (363) Metal 5X008018 5X008019 8.0 (203) 13.3 (337) 1.8 (45) 7.3 (186) 14.3 (6.59) 2 825 (390) Metal 5X009004 5X009003 8.0 (203) 13.3 (337) 1.8 (45) 7.3 (186) 14.3 (6.59) With automatic external drain, dimension is increased by 8.0 inches (203 mm), and weight is increased by 2.56 pounds (1.16 kg). *Plastic bowls include metal bowl guard. NOTE: For SPP threads, add the letter in front of the part number. bar 0.35 0.28 0.21 0.14 0.07 PRESSURE DROP psi 5 4 3 2 1 0 0 scfm 0 50 FLOW l/s 0 25 STNDRD 5-µm ELEMENT Pressure 100 psig (7 bar) 3/4 1 100 150 200 250 300 350 400 50 75 100 125 150 175 0.42 0.35 0.28 0.21 0.14 0.07 DIFFERENTIL PRESSURE psid psi 6 5 4 3 2 1 0 0 scfm 0 100 FLO W l/ s 0 50 5-µm ELEMENT Pressure psig (bar) 1-1/4 Ports 1-1/2 Ports 2 Ports 200 300 400 500 600 700 800 900 100 150 200 250 300 350 400 STNDRD SPEIFITIONS: mbient/media Temperature: Plastic owl: 40 to 125 F (4 to 52 ). Metal owl: 40 to 175 F (4 to 79 ). ody: luminum. owl capacity : 3/4 &1: 16-ounce (480-ml). 11/4, 11/2 & 2: 123-ounce (3700-ml). owl Drain: Internal automatic drain; optional manual drain or external automatic drain. owl Ring: luminum. Filter Element: 5-micron rated. Fluid Media: ompressed air. Pressure: 15 psig (1 bar) minimum with automatic drain. Plastic owl: 150 psig (10 bar) maximum. Metal owl: 200 psig (14 bar) maximum. Seals: Nitrile. 4 2009, ROSS ONTROLS. ll Rights Reserved.

40 0 2 4 0 6 8 R 100 x kpa psi 14 10 12 160 40 0 2 4 0 6 8 R 100 x kpa psi 14 10 12 160 High-apacity Regulators Regler レギュレーター jsxqysvjl Reguladores 减压阀 Ports: 3/4, 1, 11/4 & 11/2 Flow to 900 scfm Ports: 11/2, 2 & 3 Flow to 4000 scfm 80 120 80 120 200 IN OUT 200 IN OUT Self-Relieving Remote Pilot 11/2, 2 Port Size Self-Relieving Remote Pilot 3 Port Size Self-Relieving Manual Knob Self-Relieving Remote Pilot Dimensions inches (mm) Port Weight Size * ** Depth lb (kg) 3/4, 1 4.4 6.1 2.4 2.8 2.19 (111) (154) (62) (71) (0.99) 11/4, 11/2 4.9 6.4 2.1 2.8 2.50 (124) (162) (54) (71) (1.14) * Dome removal clearance: add 0.63 (16). ** ap removal clearance: add 0.65 (16.5). Less gauge. Dimensions inches (mm) Port Weight Size Depth lb (kg) 11/2, 2 6.4 5.0 3.0 2.8 8.94 (162) (127) (76) (71) (4.06) 3 8.4 7.36 3.74 8.00 21.77 (214) (187) (95) (203) (9.88) Less gauge. Regulators Reverse Flow; Piston Type; Knob Port ir Flow 0-100 0-50 Size scfm (I/s) psi psi 3/4 500 (236) 5X005049 5X005050 1 650 (300) 5X00D6003 5X006038 11/4 750 (350) 5X007003 5X007016 11/2 800 (380) 5X008001 5X008024 NOTE: For SPP threads, add the letter in front of the part number. Regulators Remote Pilot; Piston Type Port ir Flow Size scfm (l/s) Part Number 11/2 850 (400) 52118027 2 850 (400) 52119007 3 4000 (1900) 52119008 Nitrile Seals 3 4000 (1900) 5X009021 Viton Seals NOTE: For SPP threads, add the letter in front of the part number. STNDRD SPEIFITIONS: mbient/media Temperature: 40 to 175 F (4 to 79 ). ody: luminum. Fluid Media: ompressed air. Pressure: 300 psig (21 bar) maximum. Pressure: Manual: 0 to 100 psig (0 to 7 bar). Remote Pilot: 0 to 200 psig (0 to 14 bar). NOTE: pressure depends on the selection of the pilot regulator. Remote Pilot Port: 1/4 NPTF. Pressure Gauge: 0 to 200 psig (14 bar); 1/4 NPT gauge ports front and rear. Seals: Nitrile; optional Viton. Valve: 3/4 to 2 Ports - rass; 3 Port - luminum. www.rosscontrols.com 5

Port Sizes 1/4 and 3/8 Manual L-O-X Valves bsperrventile ロックアウトバルブ Rkkysokyk okyo Válvulas de Fechamento e Exaustão 安全锁定阀 Main ir and uxiliary Pneumatic Lockout/Tagout ROSS manual L-O-X (Lockout & Exhaust) valves are energy isolation valves and are generally used as the first valve in a line supplying compressed air to equipment. ir can be shut off by pushing the red L-O-X handle inward; downstream air is simultaneously exhausted through the L-O-X exhaust port. OSH compliance requires that the valve be padlocked in this position to prevent handle from being pulled out inadvertently during maintenance and/or servicing. The ROSS manual L-O-X valve has a large red operating handle for high visibility. When the handle is pulled out, there is full line pressure. short, full inward push of the handle closes off the flow of air, and quickly exhausts the pressure in the downstream line. This action is swift and doesn t require a difficult, slow, or confusing twisting action. The controlling spool of the valve employs seals made of very low-friction material. These seals enable the L-O-X spool to shift smoothly and easily even after being on standby for a long period of time. The exhaust port is threaded for the installation of a silencer or a line for remote exhausting. Two mounting holes are provided to simplify the installation of the L-O-X valve. Port Sizes 3/8 thru 11/4 Port Size Valve Model vg. v In-Out Exh. Number* 1 to 2 2 to 3 lb (kg) 1/4 1/4 Y15232002 1.9 1.9 2.3 (58) 6.5 (166) 1.0 (26) 0.9 (0.4) 3/8 3/8 Y15233012 2.5 2.6 2.3 (58) 6.5 (166) 1.0 (26) 0.9 (0.4) 3/8 3/4 Y15233002 6.0 8.0 6.3 (159) 8.8 (225) 2.0 (51) 1.5 (0.7) 1/2 3/4 Y15234002 7.1 8.3 6.3 (159) 8.8 (225) 2.0 (51) 1.5 (0.7) 3/4 3/4 Y15235012 8.6 9.5 6.3 (159) 8.8 (225) 2.0 (51) 1.5 (0.7 3/4 11/4 Y15235002 13 12 7.6 (194) 10.6 (270) 2.3 (57) 2.5 (1.1) 1 11/4 Y15236002 13 14 7.6 (194) 10.6 (270) 2.3 (57) 2.5 (1.1) 11/4 11/4 Y15237012 20 14 7.6 (194) 10.6 (270) 2.3 (57) 2.5 (1.1) 11/2 2 Y15238002 38 47 8.2 (209) 14.9 (379) 3.0 (77) 8.2 (3.6) 2 2 Y15239012 38 47 8.2 (209) 14.9 (379) 3.0 (77) 8.2 (3.6) *NPT standard. For SPP threads, insert a D after Y to the model number, e.g., YD15232002. Port Sizes 11/2 and 2 12 2 10 3 1 Manual L-O-X valve shown padlocked in closed position. The valve can only be locked in the closed position. Push/pull operation - Push the handle inward to exhaust downstream air (lockable in this position). Pull the handle outward to supply air downstream. For coordinating silencers, see MUFFL-IR Silencers (model numbers 55002003, 55003003, 55005003, 55007013 and 55009001). NOTE: Model number 55009001 is female threaded as is the exhaust port in the valve. Therefore, a pipe nipple will be needed in order to attach the muffler to the valve. UTION: These L-O-X valves are rated to 20 bar (300 psig), but the mufflers listed above are rated only to 10 bar (150 psig). These mufflers must not be used for applications with pressures greater than 10 bar (150 psig) or serious injury or damage could occur. L-O-X Sensing Port Series 15 manual L-O-X valves are now provided with 1/8 NPT sensing ports, enabling installation of a pressure sensing device such as the Pop-Up Indicator or Pressure Switch shown below. Standards suggest a method for verifying the release of energy after lockout. The ROSS 98830 Pop-Up Indicator offers 360 visibility and a redundant verification feature. y pushing on the red plunger, the operator can feel the presence of pressure and verify that the indicator is performing its sensing function. The ROSS 58686 Pressure Switch offers an electronic pressure sensing option that can be integrated into a safety monitoring system, which confirms energy isolation throughout the circuit. STNDRD SPEIFITIONS: mbient/media Temperature: 40 to 175 F (4 to 80 ). Flow Media: Filtered air; 5 micron recommended. Pressure: Port sizes 1/4 to 3/8: 15 to 145 psig (1 to 10 bar). Port sizes 3/8 to 2: 15 to 300 psig (1 to 20 bar). Lock Hole Diameter: Port sizes 1/4 to 3/8: 0.27 inch (7.06 mm). Port sizes 11/2 to 2: 0.38 inch (9.6 mm). Length of Hole: Port sizes 1/4 to 3/8: 0.43 inch (10.92 mm). Port sizes 11/2 to 2: 0.75 inch (19.1 mm). NOTE: Per specifications and regulations, these products are defined as energy isolation devices, NOT S EMERGENY STOP DEVIES. IMPORTNT NOTE: Please read carefully and thoroughly all of the UTIONS on the inside back cover. 6 2009, ROSS ONTROLS. ll Rights Reserved.

Piloted L-O-X Valves bsperrventile ロックアウトバルブ Rkkysokyk okyo Válvulas de Fechamento e Exaustão 安全锁定阀 Main ir and uxiliary Pneumatic Lockout/Tagout MNUL PILOT Operated just like the smaller manual L-O-X valve. The position of the red handle indicates instantaneous full flow pressurizing or exhausting capability. SOLENOID PILOT 3 1 Y3 2 Port Size Valve Model vg. v In-Out Exh. Number* 1 to 2 2 to 3 lb (kg) 11/2 21/2 Y27838006 68 70 8.4 (213) 10.2 (259) 6.6 (162) 15.3 (6.9) 2 21/2 Y27839006 70 70 8.4 (213) 10.2 (259) 6.6 (162) 15.3 (6.9) 21/2 21/2 Y27839016 70 71 8.4 (213) 10.2 (259) 6.6 (162) 15.3 (6.9) 3 21/2 39000829** 140 140 19.6 (496) 25.3 (643) 11.5 (292) 110 (49.9) *NPT standard. For SPP threads, insert a D after Y to the model number, e.g., YD27838006 or a D prefix on 3 L-O-X, e.g., D 39000829. Port Size Valve Model vg. v In-Out Exh. Number* 1 to 2 2 to 3 lb (kg) 1/4 1/2 Y27732072 2.5 3.1 7.1 (181) 8.4 (212) 6.5 (165) 3.5 (1.6) 3/8 1/2 Y27733072 3.6 5.3 7.1 (181) 8.4 (212) 6.5 (165) 3.5 (1.6) 1/2 1/2 Y27734082 3.3 5.3 7.1 (181) 8.4 (212) 6.5 (165) 3.5 (1.6) 1/2 1 Y27734072 6.3 9.2 7.1 (181) 9.0 (228) 6.9 (175) 4.3 (1.9) 3/4 1 Y27735072 7.7 11 7.1 (181) 9.0 (228) 6.9 (175) 4.3 (1.9) 1 1 Y27736082 8.0 12 7.1 (181) 9.0 (228) 6.9 (175) 4.3 (1.9) 1 11/2 Y27736072 23 34 8.1 (206) 11.8 (299) 6.9 (175) 8.0 (3.6) 11/4 11/2 Y27737072 30 32 8.1 (206) 11.8 (299) 6.9 (175) 8.0 (3.6) 11/2 11/2 Y27738082 30 31 8.1 (206) 11.8 (299) 6.9 (175) 8.0 (3.6) 11/2 21/2 Y27738072 68 70 9.3 (235) 13.8 (352) 7.3 (184) 17.5 (7.9) 2 21/2 Y27739072 70 70 9.3 (235) 13.8 (352) 7.3 (184) 17.5 (7.9) 21/2 21/2 Y27739082 70 71 9.3 (235) 13.8 (352) 7.3 (184) 17.5 (7.9) 3 21/2 39000896** 140 140 19.6 (496) 25.3 (643) 14.9 (379) 115 (53.0) * NPT standard. For SPP threads, insert a D after Y to the model number, e.g., YD27732072 or a D prefix on 3 L-O-X, e.g., D 39000829. **3 Inch L-O-X Valve for Lockout Top View and Mounting Dimensions - inches (mm) 3.9 (99) 10.0 (254) 3.9 (99) 10.0 (254) 3" NPT OUTLET 3" NPT INLET 14.6 (371) 14.6 (371) Manual Pilot - Model 39000829 Solenoid Pilot - Model 39000896 For coordinating silencers, see MUFFL-IR Silencers (model numbers 55004003, 55006003, 55008001 and 55009002). STNDRD SPEIFITIONS: mbient/media Temperature: Manual Pilot: 40 to 175 F (4 to 80 ). mbient Temperature: Solenoid Pilot: 40 to 120 F (4 to 50 ). Media Temperature: Solenoid Pilot: 40 to 175 F (4 to 80 ). Flow Media: Filtered air; 5 micron recommended. Pressure: Manual Pilot: Port sizes 1 to 21/2: 15 to 150 psig (1 to 10 bar). Port sizes 11/2 to 21/2: 30 to 150 psig (2 to 10 bar). Pressure: Solenoid Pilot: Port sizes 1/4 to 11/2: 15 to 150 psig (1 to 10 bar). Port sizes 11/2 to 21/2: 30 to 150 psig (2 to 10 bar). STNDRD SPEIFITIONS: For 3 inch L-O-X : Pressure: 30 to 150 psig (2 to 10 bar). Pilot Pressure: Must be equal to or greater than inlet pressure. Flow Media: Filtered air; 5 micron filter recommended. For model Y39000829 mbient/media Temperature: 40 o to 175 o F (4 o to 80 o ). For model Y39000896 Solenoids: or D power. Power onsumption: 87 V inrush, 30 V holding on 50 or 60 Hz; 14 watts on D. mbient Temperature: 40 o to 120 o F (4 to 50 o ). Media Temperature: 40 o to 175 o F (4 to 80 o ). www.rosscontrols.com 7

ir Distribution Luftverteilung エアーディストリビューション gok forj.k Distribuição de r 气流分配 Standard Size 12 Supply headers equipped with an auxiliary outlet 3/4 port Independent exhaust ports on circuit branches ll inlet and outlet ports are 3/4 size dditional 1/4 port on outlet Modules (of like size) can be stacked to fit application assembly hardware included Main ir Panel pplications Port 3/4 Port 3/4 PD-HR-N12- (NPT) PD-HR-12- (SPP) Supply header with regulator. 7.34 (184) 8.7 (221) 3.2 (82) 4.0 (1.9) PD-HR-N12- (NPT) PD-HR-12- (SPP) Supply header with regulator and check. 7.34 (184) 10.1 (257) 3.2 (82) 5.0 (2.3) NOTE: This circuit requires a downstream pressure release. PD-HRX-N12- (NPT) PD-HRX-12- (SPP) Supply header with regulator and L-O-X valve. 7.34 (184) 15.3 (387) 3.2 (82) 10.0 (4.6) PD-HRX-N12- (NPT) PD-HRX-12- (SPP) Supply header with regulator, check, and L-O-X valve. 7.34 (184) 15.3 (387) 3.2 (82) 10.0 (4.6) STNDRD SPEIFITIONS: For valves on this page. mbient Temperature: 40 to 120 F (4 to 50 ). Media Temperature: 40 to 175 F (4 to 80 ). Flow Media: Filtered air; 5 micron recommended. Pressure: 0 to 150 psig (0 to 10 bar). 8 2009, ROSS ONTROLS. ll Rights Reserved.

ir Distribution Luftverteilung エアーディストリビューション gok forj.k Distribuição de r 气流分配 Standard Size 20 ll inlet and exhaust ports are 11/4 size. s are 1 size dditional 1/4 port on outlet Supply headers equipped with an auxiliary 1 outlet port ommon exhaust port on circuit branches and headers Modules (of like sizes) can be stacked to fit application assembly hardware included Main ir Panel pplications Port 11/4 Port 1 PD-HR-N20- (NPT) PD-HR-20- (SPP) Supply header with regulator. Exhaust 8.7 (221) 13.1 (332) 3.4 (86) 10.0 (4.6) PD-HR-N20- (NPT) PD-HR-20- (SPP) Supply header with regulator and check. Exhaust 8.7 (221) 14.4 (365) 3.4 (86) 11.0 (5.0) NOTE: This circuit requires a downstream pressure release. PD-HRX-N20- (NPT) PD-HRX-20- (SPP) Supply header with regulator, and L-O-X valve. Exhaust Exhaust 8.7 (221) 17.9 (454) 3.4 (86) 13.0 (5.9) PD-HRX-N20- (NPT) PD-HRX-20- (SPP) Supply header with regulator, check, and L-O-X valve. Exhaust Exhaust 8.7 (221) 18.8 (477) 3.4 (86) 13.0 (5.9) STNDRD SPEIFITIONS: For valves on this page. mbient Temperature: 40 to 120 F (4 to 50 ). Media Temperature: 40 to 175 F (4 to 80 ). Flow Media: Filtered air; 5 micron recommended. Pressure: 0 to 150 psig (0 to 10 bar). www.rosscontrols.com 9

Economy Size 8 ir Distribution Luftverteilung エアーディストリビューション gok forj.k Distribuição de r 气流分配 Supply headers equipped with auxiliary outlet 3/4 NPT or SPP port. Gauges shipped loose for field installation. Modules can be stacked to fit application - assembly hardware included. For circuits with valves and other options, consult ROSS. Main ir Panel pplications Port 3/4 Port 1/2 MS-H-N8- (NPT) MS-H-8- (SPP) Supply header outlet. 3.2 (81.2) 2.8 (71) 3.8 (96.5) 3.0 (1.36) MS-HR-N8- (NPT) MS-HR-8- (SPP) Supply header with regulator. 4.1 (104) 4.7 (119) 6.7 (170) 4.2 (1.90) MS-HR-N8- (NPT) MS-HR-8- (SPP) Supply header with regulator and check. 4.1 (104) 4.7 (119) 9.3 (236) 4.67 (2.12) MS-HRX-N8- (NPT) MS-HRX-8- (SPP) Supply header with regulator and shut-off. 4.1 (104) 4.7 (119) 11.5 (292) 5.0 (2.27) MS-HRX-N8- (NPT) MS-HRX-8- (SPP) Supply header with regulator, check, and shut-off. 4.1 (104) 4.7 (119) 11.7 (297) 4.75 (2.15) STNDRD SPEIFITIONS: For valves on this page. mbient Temperature: 40 to 120 F (4 to 50 ). Media Temperature: 40 to 175 F (4 to 80 ). Flow Media: Filtered air; 5 micron recommended. Pressure: 0 to 150 psig (0 to 10 bar). 10 2009, ROSS ONTROLS. ll Rights Reserved.

Economy Size 12 MS-HR-N12- (NPT) MS-HR-12- (SPP) Supply header with regulator. ir Distribution Luftverteilung エアーディストリビューション gok forj.k Distribuição de r 气流分配 Supply headers equipped with auxiliary outlet 3/4 NPT or SPP port. Gauges shipped loose for field installation. Modules can be stacked to fit application - assembly hardware included. For circuits with valves and other options, consult ROSS. MS-H-N12- (NPT) MS-H-12- (SPP) Supply header outlet. 3.2 (81.2) 2.8 (71) 3.8 (96.5) 3.0 (1.36) 4.6 (117) 7.2 (103) 7.5 (191) 5.4 (2.45) Main ir Panel pplications Port 3/4 Port 3/4 MS-HR-N12- (NPT) MS-HR-12- (SPP) Supply header with regulator and check. 4.6 (117) 7.2 (183) 10.4 (264) 5.87 (2.66) MS-HRX-N12- (NPT) MS-HRX-12- (SPP) Supply header with regulator and shut-off. 4.6 (117) 7.2 (183) 12.1 (307) 5.97 (2.71) MS-HRX-N12- (NPT) MS-HRX-12- (SPP) Supply header with regulator, check, and shut-off. 4.6 (117) 7.2 (183) 12.7 (323) 6.08 (2.76) STNDRD SPEIFITIONS: For valves on this page. mbient Temperature: 40 to 120 F (4 to 50 ). Media Temperature: 40 to 175 F (4 to 80 ). Flow Media: Filtered air; 5 micron recommended. Pressure: 0 to 150 psig (0 to 10 bar). www.rosscontrols.com 11

ir Distribution Luftverteilung エアーディストリビューション gok forj.k Distribuição de r 气流分配 Main ir Panel pplications Features: Supply headers equipped with 3/4 auxiliary outlet port on size 8 and 12 Supply header equipped with 1 auxiliary outlet port on size 20 Modules of same basic size can be stacked together to fit any application - assembly hardware included ommon exhaust port on size 20 header blocks More efficient use of space Reduced engineering cost Fast easy installation Reduced procurement Standardization and improved appearance Energy savings HOW TO ORDER (hoose your options (in red) to configure your valve model number.) PD HR N 12 PRODUT SERIES Standard...PD Economy... MS ONFIGURTION Header lock...h* Header + Regulator...HR Header + Regulator + heck...hr Header + Regulator + Lockout... HRX Header + Regulator + heck + Lockout...HRX *Only available on MS Series ir Distribution Stations. SI SIZE 3/4 inlet x 1/2 outlet...8* 3/4 inlet x 3/4 outlet... 12 11/4 inlet x 1 outlet... 20 *Only available on MS Series. THRED SPP (G)... NPT... N SE... S* *Only available on PD Series air distribution stations. STNDRD SPEIFITIONS: For valves on this page. mbient Temperature: 40 to 120 F (4 to 50 ). Media Temperature: 40 to 175 F (4 to 80 ). Flow Media: Filtered air; 5 micron recommended. Pressure: 0 to 150 psig (0 to 10 bar). 12 2009, ROSS ONTROLS. ll Rights Reserved.

ounterbalance for Mechanical Stamping Presses The ROSS counterbalance system integrates modern air valve technology with electrical controls to monitor and maintain appropriate counterbalance pressures. n automatic counterbalance system receives an input value (called the set pressure) for a particular die and then monitors and maintains the counterbalance pressure automatically. In its simplest form, the operator manually inputs this value from a die/pressure table. In more advanced systems, this can be pre-loaded using a die recipe program. The operator inputs a die number during set-up or the system can read the die number automatically, allowing the set value to be retrieved from stored tables. The standard OEM system includes two or more air cylinders attached between the slide and main frame, a pressure control regulator, a check valve, a surge tank, and a manual bleed off valve. The surge tank is used to store air displaced from the cylinders, since it would be cost prohibitive to refill the system with every stroke of the press. The system acts like an adjustable spring. The regulator is used to set the ylinder Surge tank Switch heck pressure for the total weight of the slide plus the die. The press OEM provides a chart for setting the pressure on any given die weight. This setting is the pressure at the full ram up position (top dead center). Surveys show however, that 90% of companies have pressures leed valve Regulator set at maximum plant pressure or 80-90 psi and never adjust it! Standard ounterbalance System Press position is given in degrees, which represents the position of the crankshaft during the press cycle. 0 degrees is referred to as TD (top dead center) and 180 degrees, where the work is done, is referred to as D (bottom dead center). s the crank moves from TD to D, we are in the downward stroke. s the crank moves from D back to TD, we are in the upward stroke. During the downward stroke, the weight of the slide and die are acted on by gravity, which pulls the slide away from the press drive, opening up small tolerances. When the upper and lower dies meet, the upper die decelerates until all tolerance openings close and the drive begins to push. This creates damaging shock loads throughout the press. fter this initial shock loading, the die is driven through the work and then immediately reversed to pull the die back up. efore the die can move upward, all of the tolerances are re-opened, sending additional shock loads into the system. Properly set counterbalance pressures will close these tolerances to eliminate shock loading. The adverse effects of an underbalanced condition include heavy shock loads, increased operating costs (due to the heavier motor loads required to lift the slide), lower parts rates and higher scrap costs, loss of ram parallelism and excessive wear to the drive, dies, gibs and cylinder packings. While an underbalanced condition is most undesirable, too much pressure in the system also has its drawbacks. n overbalanced condition consumes a great deal of flywheel energy, can reduce tonnage to the part and even result in the slide becoming stuck on bottom if there is not sufficient energy to overcome die separation, slide reversal and loading forces. The effects of an overbalanced condition include damage to shut height equipment, tripping of motor overloads, higher air consumption, excessive clutch and brake wear, inconsistent die velocity, inaccurate starting or stopping and higher maintenance costs. So, what is wrong with the equipment that came on the press? Nothing but it is a system with a number of minimal performance characteristics. If the system leaks, it is desirable to correct the pressure as quickly as possible and to maintain set pressures. The standard OEM system does not do this. The recovery time to increase pressure is long, due to the regulator effect, and has no way of decreasing pressure, should it be necessary. The ROSS automatic system takes pressure snap-shots (via a transducer mounted on the counterbalance tank) at a pre-determined window (TD), where set pressure values can be compared to actual pressure in the system. Depending upon requirements, the automatic Upper Die Upper Die counterbalance units can fill or exhaust to accurately maintain the set pressure. High flow poppet valves controlling large volumes of air offer Lower Die maximum adjustment speeds during production as well as during die Lower Die changes. Each unit has built-in check valves and a manual regulation circuit, should the automatic system require service. Lockout valves are Shock at die strike without counterbalances standard for required cylinder maintenance. Improper ounterbalance settings affect just about every area of press performance. Installing an automatic counterbalance system can improve performance, minimize wear, reduce strain on the press, reduce operating costs and enhance safety. www.rosscontrols.com 13

utomatic ounterbalance Gewichtsausgleich カウンターバランス cjkcj Hkkj ompensador 平衡力 utomatic Pressure ontrol pplications Interfaces with controls to monitor/maintain correct counterbalance pressure 3/4 units furnished with DIN electrical connections 1 & 11/4 units furnished with rad Harrison connectors 39001018Z (110 volts ) 39001018W (24 volts D) Economy 3/4 fill-dump. 4.2 (107) 7.5 (191) 5.7 (145) 6.0 (2.8) * For SPP threads add D prefix to the model number, e.g., D39001018W. PFD-MPRX-N12--E (110 volts ) PFD-MPRX-N12--W (24 volts D) 3/4 fill-dump with auto-manual select and parallel manual circuit. DUMP LOWDOWN 7.1 (181) 10.0 (254) 11.7 (298) 20.0 (9.1) * For SPP threads change N to in the model number, e.g., PFD-MPRX-12--E. FILL MN-UTO PFD-MSRX-N16--E (110 volts ) PFD-MSRX-N16--W (24 volts D) 1 fill-dump with auto-manual select and parallel manual circuit. DUMP LOWDOWN 8.3 (211) 15.4 (392) 12.1 (308) 45.0 (20.5) * For SPP threads change N to in the model number, e.g., PFD-MSRX-16--E. PFD-MSR1X-N16--E (110 volts ) PFD-MSR1X-N16--W (24 volts D) 1 fill-dump with auto-manual select and parallel remote manual adjustment circuit. 8.3 (211) 15.4 (392) 12.1 (308) 45.0 (20.5) * For SPP threads change N to in the model number, e.g., PFD-MSR1X-16--E. FILL MN- UTO DUMP FILL MN- UTO LOWDOWN Remote Pilot PFD-MSRX-N20--E (110 volts ) PFD-MSRX-N20--W (24 volts D) 11/4 fill-dump with auto-select and parallel manual circuit. DUMP LOWDOWN 10.4 (264) 26.5 (673) 19.2 (488) 87.0 (39.5) FILL * For SPP threads change N to in the model number, e.g., PFD-MSRX-20--E. MN- UTO 14 2009, ROSS ONTROLS. ll Rights Reserved.

Size 20 utterfly control valve included Slow raise cushion circuit included vailable mounted on a plate and pre-wired Furnished with rad Harrison connectors PFD-USMRR-N20--E (110 volts ) PFD-USMRR-N20--W (24 volts D) 1-1/4 fill-dump solenoid circuit, butterfly operator valve and remote low-down. Die ushion Module Ziehkissendämpfung ダイクッション MkbZ xíh lmofada 模具缓冲器 DUMP Port 11/4 Port 11/4 UTTERFLY VLVE 11.9 (303) 23.5 (597) 21.1 (536) 164.0 (74.7) FILL * For SPP threads change N to in the model number, e.g., PFD-USMSRR-20--E. Kit includes electrical junction box, twenty terminals, transducer (with integral pressure switch/digital gauge), four solenoid cords with cord grips, and 5-meter transducer cord with connector. Shown with mounting plate and pre-wired. (Option P PFD-USMRR-PN20--E) ccessory Kit (PFD-KIT): Transducer and electrical box available separately see page 26. Note: When ordering with option P (pre-mounted and pre-wired), order transducer and 5-meter cord separately. See page 26. Die lamping Ziehkissenspanner ダイクランプ MkbZ idm+ Grampo 模具夹具 Size 12 Ports 3/4 Includes electrical cords with cord grips Valves are built to the NSI mounting standard (ISO 5599/II valves also available onsult ROSS) Mounted on a plate and pre-wired Single Solenoid PD-121-PN16--E (110 volts ) PD-121-PN16--W (24 volts D) Double Solenoid PD-221-PN16--E (110 volts ) PD-221-PN16--W (24 volts D) 3/4 5/2 SE valve with pressure switch. Mounted on a steel plate, pre-piped and pre-wired to a NEM 12 junction box. PD-121-PN16--E/W PD-221-PN16--E/W Model Number* PD-121-PN16--E 6.8 (172) 16.0 (381) 15.0 (407) 25.0 (11.4) PD-221-PN16--E 8.2 (207) 16.0 (381) 15.0 (407) 25.0 (11.4) *Specify voltage and hertz when ordering. For SPP threads change N to in the model number, e.g., PD-121-P16--E. www.rosscontrols.com 15

12 Normally losed (N) 10 Mechanical Devices/Inline Poppet Valves 1 Normally Open (NO) 3/2 Valves 12 10 Mechanische Geräte 機械的機構 ;kaf=dh midj.k Dispositivos Mecânicos 机械装置 Flywheel rake, olster and Part Ejection pplications 2/2 Valves Normally losed (N) Normally Open (NO) 3 3 2 1 2 2 1 2 1 Port Valve Model Number* vg. V Size N NO N NO lb (kg) 1/4 27712001 27722001 2.3 2.3 3.6 (91) 3.2 (79) 6.9 (175) 2.5 (1.2) 3/8 27713001 27723001 3.8 3.3 3.6 (91) 3.2 (79) 6.9 (175) 2.5 (1.2) 1/2 27714011 27724011 4.0 3.5 3.6 (91) 3.2 (79) 6.9 (175) 2.5 (1.2) 1/2 27714001 27724001 7.7 6.5 4.6 (116) 3.2 (79) 7.6 (193) 3.3 (1.5) 3/4 27715001 27725001 9.0 7.3 4.6 (116) 3.2 (79) 7.6 (193) 3.3 (1.5) 1 27716011 27726011 9.0 7.9 4.6 (116) 3.2 (79) 7.6 (193) 3.3 (1.5) 1 27716001 27726001 24 21 6.7 (169) 4.1 (104) 10.4 (265) 7.0 (3.2) 11/4 27717001 27727001 29 20 6.7 (169) 4.1 (104) 10.4 (265) 7.0 (3.2) 11/2 27718011 27728011 29 21 6.7 (169) 4.1 (104) 10.4 (265) 7.0 (3.2) 11/2 27718001 27728001 49 49 8.7 (219) 5.2 (131) 11.8 (300) 15.5 (6.9) 2 27719001 27729001 57 57 8.7 (219) 5.2 (131) 11.8 (300) 15.5 (6.9) 21/2 27719011 27729011 64 72 8.7 (219) 5.2 (131) 11.8 (300) 15.5 (6.9) *NPT standard. For SPP threads, add a D prefix to the model number, e.g., D27712001. For 110 volts add Z suffix to the model number, for 24 volts D add W suffix to the model number. Port Sizes Valve Model Number* vg. V In-Out Exh. N NO N NO lb (kg) 1/4 1/2 27732001 27742001 2.8 2.5 3.6 (91) 3.2 (79) 7.2 (182) 2.5 (1.2) 3/8 1/2 27733001 27743001 4.0 3.0 3.6 (91) 3.2 (79) 7.2 (182) 2.5 (1.2) 1/2 1/2 27734011 27744011 3.8 3.0 3.6 (91) 3.2 (79) 7.2 (182) 2.5 (1.2) 1/2 1 27734001 27744001 7.8 7.2 4.6 (116) 3.6 (92) 7.9 (201) 3.3 (1.5) 3/4 1 27735001 27745001 9.4 7.2 4.6 (116) 3.6 (92) 7.9 (201) 3.3 (1.5) 1 1 27736011 27746011 10 7.2 4.6 (116) 3.6 (92) 7.9 (201) 3.3 (1.5) 1 11/2 27736001 27746001 29 21 6.7 (169) 4.9 (123) 10.4 (265) 7.0 (3.2) 11/4 11/2 27737001 27747001 31 22 6.7 (169) 4.9 (123) 10.4 (265) 7.0 (3.2) 11/2 11/2 27738011 27748011 31 21 6.7 (169) 4.9 (123) 10.4 (265) 7.0 (3.2) 11/2 21/2 27738001 27748001 69 58 8.7 (219) 6.4 (161) 12.4 (313) 16.5 (7.4) 2 21/2 27739001 27749001 70 60 8.7 (219) 6.4 (161) 12.4 (313) 16.5 (7.4) 21/2 21/2 27739011 27749011 71 55 8.7 (219) 6.4 (161) 12.4 (313) 16.5 (7.4) *NPT standard. For SPP threads, add a D prefix to the model number, e.g., D27732001. For 110 volts add Z suffix to the model number, for 24 volts D add W suffix to the model number. 4/2 Valves 4 2 14 3 1 Port Sizes Valve Model vg. In-Out Exh. Number* V lb (kg) 1/4 1/2 27762001 2.5 4.0 (100) 3.9 (97) 7.2 (182) 3.0 (1.4) 3/8 1/2 27763001 3.6 4.0 (100) 3.9 (97) 7.2 (182) 3.0 (1.4) 1/2 1/2 27764011 3.7 4.0 (100) 3.9 (97) 7.2 (182) 3.0 (1.4) 1/2 1 27764001 6.9 4.7 (118) 5.3 (135) 9.0 (228) 5.3 (2.4) 3/4 1 27765001 8.2 4.7 (118) 5.3 (135) 9.0 (228) 5.3 (2.4) 1 1 27766011 8.9 4.7 (118) 5.3 (135) 9.0 (228) 5.3 (2.4) 1 11/2 27766001 23 6.5 (166) 8.3 (211) 10.7 (271) 11.3 (5.1) 11/4 11/2 27767001 24 6.5 (166) 8.3 (211) 10.7 (271) 11.3 (5.1) 11/2 11/2 27768011 25 6.5 (166) 8.3 (211) 10.7 (271) 11.3 (5.1) *NPT standard. For SPP threads, add a D prefix to the model number, e.g., D27762001. For 110 volts add Z suffix to the model number, for 24 volts D add W suffix to the model number. STNDRD SPEIFITIONS: For valves on this page. Solenoids: or D power. Standard Voltages: 110 volts, 24 volts D. Power onsumption: 87 V inrush, 30 V holding on 50 or 60 Hz; 14 watts on D. mbient Temperature: 40 to 120 F (4 to 50 ). Media Temperature: 40 to 175 F (4 to 80 ). Flow Media: Filtered air; 5 micron recommended. Pressure: 1/4 to 11/2 Port Sizes: 15 to 150 psig (1 to 10 bar); 11/2 to 21/2 Port Sizes: 30 to 150 psig (2 to 10 bar). Pilot Pressure: When external supply is used, pressure must be equal to or greater than inlet pressure. IMPORTNT NOTE: Please read carefully and thoroughly all of the UTIONS on the inside back cover. 16 2009, ROSS ONTROLS. ll Rights Reserved.

DM 2 Series D Double Valves for lutch/rake Kupplung/remse クラッチ / ブレーキ Iaktk@ xfrjks/kd Embreagem/Freio 离合器 / 制动器 Double Valves with Total Dynamic Monitoring & omplete Memory Self Monitored - lutch/rake ontrol Size 2 Size 8 Size 30 Simplified Schematic Size 2, 4, 8, 12 and 30 Total Dynamic Monitoring With omplete Memory: Memory, monitoring, and air flow control functions are simply integrated into two identical valve elements. Valves lock-out due to asynchronous movement of valve elements during actuation or de-actuation, resulting in a residual outlet pressure of less than 1% of supply. Overt action is required for reset cannot be reset by removing and reapplying supply pressure. Reset can only be accomplished by remote air signal or by optional integrated electrical (solenoid) reset. asic 3/2 Normally losed Valve Function: Dirt tolerant, wear compensating poppet design for quick response and high flow capacity. Teflon back-up rings on pistons to enhance valve endurance operates with or without inline lubrication. Status Indicator (Optional): Includes a pressure switch with both normally open and normally closed contacts to provide status feedback to the press control system indicating whether the valve is in the lockout or ready-to-run condition. The Status Indicator can be ordered installed or purchased separately and added to any DM 2 base. Silencers: ll models include high flow, clog resistant silencers. Mounting: ase mounted with SPP or NPT pipe threads. and outlet ports on both sides provide for flexible piping (plugs for unused ports included). aptive valve-to-base mounting screws. Size 12 and 30 Intermediate Pilots: Increase pilot air flow for fast valve response, make it possible to use the same size solenoids as valve sizes 4 & 8, thereby reducing electrical power requirements for these larger valves. STNDRD SPEIFITIONS: Solenoids: ccording to VDE 0580. Enclosure rating according to DIN 400 50 IP 65. Two solenoids, rated for continuous duty (three with solenoid reset option). Standard Voltages: 110 volts, 50/60 Hz; 220** volts, 50/60 Hz; 24 volts D. For other voltages, consult ROSS. ** 220 volts not available in the U.S. (OSH regulations limit press control voltage to no more than 120 volts. Specify voltage and frequency on order. Power onsumption (each solenoid): Size 2: For primary and reset solenoids: 12 V maximun in rush, 9.8 V maximun holding on, 7.5 watts on D. Size 4, 12, 30: For primary and reset solenoids: 6.0 watts on D; 15.8 V inrush and 10.4 V holding on. Size 8: Primary solenoids: 15 watts on D; 36 V inrush and 24.6 V holding on. Reset solenoid: 6.0 watts on D; 15.8 V inrush and 10.4 V holding on. Enclosure rating: IP65, IE 60529. Electrical connection: Size 2: ISO 4400, Type. Order connectors separately. Size 4, 8, 12, 30: DIN 43650, Form. Order connectors separately. mbient Temperature: 15 to 120 F (-10 to 50 ). Media Temperature: 40 to 175 F (4 to 80 ). Flow Media: Filtered, lubricated or unlubricated (mineral oils according to DIN 51519, viscosity classes 32-46); 5 micron recommended. Pressure: Size 2: 45 to 150 psig (3 to 10 bar). Size 4, 8, 12, 30: 30 to 120 psig (2 to 8 bar). Pressure Switch (Status Indicator) Rating: ontacts - 5 amps at 250 volts, or 5 amps at 30 volts D. Monitoring: Dynamically, cyclically, internally during each actuating and de-actuating movement. Monitoring function has memory and requires an overt act to reset unit after lockout. Mounting orientation: Preferably horizontally (valve on top of base) or vertically (with pilot solenoids on top). IMPORTNT NOTE: Please read carefully and thoroughly all of the UTIONS on the inside back cover. www.rosscontrols.com 17

PRODUT DM 2 Series D Double Valves for lutch/rake THRED SPP... D NPT... N N/ (no base)... X REVISION LEVEL Kupplung/remse クラッチ / ブレーキ Iaktk@ xfrjks/kd Embreagem/Freio 离合器 / 制动器 HOW TO ORDER (hoose your options (in red) to configure your valve model number.) DM2D D 4 2 1 1 STTUS INDITOR 1...YES X... NO RESET TYPE 1...REMOTE 2... SOLENOID 4... MNUL SI SIZE 2...2 4...4 8...5 12...6 30...8 SE PORT SIZE Size 2 1/4 inlet 1/4 outlet...0 3/8 inlet 3/8 outlet...1 Size 4 1/2 inlet 1/2 outlet...2 1/2 inlet 3/4 outlet...3 Size 8 3/4 inlet 3/4 outlet...4 1 inlet 1 outlet...5 Size 12 1inlet 1outlet...6 1inlet 11/2 outlet...7 Size 30 1 inlet 2 outlet...8 Valve only (less base)... X Note: DM 2 size 2 solenoids require DIN Form electrical connectors (see page 25). VOLTGE... 24 volts D... 110 volts, 50/60 Hz **... 220 volts, 50/60 Hz ** 220 V not available in the U.S. (OSH regulations limit press control voltage to no more than 120 volts ). SE MODEL NUMERS and SE SPEIFI INFORMTION Port Size ase Status Weight Model Number* Indicator lb (kg) 1/4 1/4 187291 No 1.7 (0.8) 1/4 1/4 187391 Yes 2.1 (1.0) 3/8 3/8 187491 No 1.7 (0.8) 3/8 3/8 187591 Yes 2.1 (1.0) 1/2 1/2 169791 No 1.7 (0.8) 1/2 1/2 169891 Yes 2.3 (1.1) 1/2 3/4 169991 No 1.7 (0.8) 1/2 3/4 170091 Yes 2.3 (1.1) 3/4 3/4 170191 No 3.6 (1.6) 3/4 3/4 170291 Yes 4.2 (1.9) 1 1 170391 No 3.6 (1.6) 1 1 170491 Yes 4.2 (1.9) 1 1 170591 No 6.2 (2.8) 1 1 170691 Yes 6.8 (3.1) 1 11/2 170791 No 6.2 (2.8) 1 11/2 170891 Yes 6.8 (3.1) 11/2 2 170991 No 12.0 (5.4) 11/2 2 171091 Yes 12.6 (5.7) *NPT port threads. For SPP threads add a D prefix to the model number, e.g., D170091. SIZE 2 4.41 (112.0) 4.50 (114.3) DIMENSIONS inches (mm) View X (ase mounting hole pattern) Valve envelope (ased in overall hole dimnsions at left.) 0.22 (5.6) (4 places) Weight: Valve and base assembly with status indicator and solenoid reset: 5.0 lb (2.3 kg). 1.19 (30.2) 1.00 (25.3) 0.82 (20.9) 10.02 (254.6) with Status Indicator 7.82 (198.7) 3.20 (81.3) 4.00 (101.6) 4.00 (101.6) 2.07 (52.6) 0.25 (6.4) 18 2009, ROSS ONTROLS. ll Rights Reserved.

SIZE 4 DM 2 Series D Double Valves for lutch/rake Kupplung/remse クラッチ / ブレーキ Iaktk@ xfrjks/kd Embreagem/Freio 离合器 / 制动器 DIMENSIONS inches (mm) View X (ase mounting hole pattern) Weight: Valve and base assembly with status indicator and solenoid reset: 6.0 lb (2.8 kg). SIZE 8 View X (ase mounting hole pattern) Weight: Valve and base assembly with status indicator and solenoid reset: 9.1 lb (4.2 kg). SIZE 12 View X (ase mounting hole pattern) Weight: Valve and base assembly with status indicator and solenoid reset: 15.5 lb (7.1 kg). SIZE 30 View X (ase mounting hole pattern) Weight: Valve and base assembly with status indicator and solenoid reset: 32.6 lb (14.8 kg). www.rosscontrols.com 19

SERPR L-G Double Valves for lutch/rake Kupplung/remse クラッチ / ブレーキ Iaktk@ xfrjks/kd Embreagem/Freio 离合器 / 制动器 Size 4 Self Monitored - lutch/rake ontrol Y Y Y YD 3 1 Manual Reset L (Lockout Indicator) YE 2 Port Monitor Valve Model Number verage V * Size Size Reset Right Left In-Out Out-Exh. lb (kg) 4 3/8 Manual 3573D3191 3573D3195 3.0 6.0 7.4 (188) 6.3 (160) 7.4 (188) 8.3 (3.7) 4 3/8 Remote 3573D3192 3573D3196 3.0 6.0 7.4 (188) 6.3 (160) 7.4 (188) 8.3 (3.7) 4 1/2 Manual 3573D4211 3573D4215 3.0 8.0 7.4 (188) 6.3 (160) 7.4 (188) 8.3 (3.7) 4 1/2 Remote 3573D4212 3573D4216 3.0 8.0 7.4 (188) 6.3 (160) 7.4 (188) 8.3 (3.7) 4 3/4 Manual 3573D5211 3573D5215 3.0 9.0 7.4 (188) 6.3 (160) 7.4 (188) 8.3 (3.7) 4 3/4 Remote 3573D5212 3573D5216 3.0 9.0 7.4 (188) 6.3 (160) 7.4 (188) 8.3 (3.7) *NPT standard. For SPP threads, add a D prefix to the model number, e.g., D3573D3191. Sizes 8, 12, 30 Lockout Indicator 3 1 Sol. Sol. Y 1 2 3 4 Y Port Valve Model Number verage V Size Size w/ Overrides w/o Overrides In-Out Out-Exh. lb (kg) 8 1/2 35734142 35734162 3.5 8.5 8.5 (216) 7.1 (180) 12.3 (312) 15.3 (6.9) 8 3/4 35735142 35735162 4.0 12 8.5 (216) 7.1 (180) 12.3 (312) 19.0 (8.6) 12 3/4 35735152 35735172 8.0 15 9.0 (228) 8.5 (216) 13.4 (340) 19.0 (8.6) 8 1 35736152 35736172 4.0 12 8.5 (216) 7.1 (180) 12.3 (312) 15.3 (6.9) 12 1 35736162 35736182 8.5 19 9.0 (228) 8.5 (216) 13.4 (340) 19.0 (8.6) 12 11/4 35737162 35737182 9.0 21 9.0 (228) 8.5 (216) 13.8 (351) 19.0 (8.6) 30* 11/4 35737152 35737172 20 42 12.4 (314) 11.1 (282) 17.7 (450) 37.5 (16.9) 30* 11/2 35738162 35738182 21 43 12.4 (314) 11.1 (282) 17.7 (450) 37.5 (16.9) *NPT standard. For SPP threads, add a D prefix to the model number, e.g., D35734142. 2 inch port size available on size 30 valves. Order part number 1999H77 flange kit separately. STNDRD SPEIFITIONS: For valves on this page. Pilot Solenoids: Two, rated for continuous duty. Standard Voltages: 110 volts D, 24 volts D. Other voltages available. Power onsumption: Size 4: Each solenoid, 30 V inrush, 16 V holding on 50 or 60 Hz; 11 watts on D. Sizes 8,12,30: Each solenoid, 87 V inrush, 30 V holding on 50 or 60 Hz; 14 watts on D. Electrical onnections: Size 4 uses Form DIN connectors at solenoids. Size 8, 12 and 30 has built-in terminal strip. Z (Pneumatic Reset Port) mbient Temperature: 40 to 120 F (4 to 50 ). Media Temperature: 40 to 175 F (4 to 80 ). Flow Media: Filtered air; 5 micron recommended. Pressure: Size 4: 30 to 100 psig (2 to 7 bar). Sizes 8,12,30: 30 to 125 psig (2 to 8.5 bar). L-G Reset Pressure: Size 4: Remote pneumatic reset models require a pressure of at least 30 psig (2 bar). Manual reset models use internal valve pressure. Sizes 8,12,30: 60 psig (4 bar) minimum. Port: Models are available with the inlet port on either the right or the left side of the valve body (size 4 only). IMPORTNT NOTE: Please read carefully and thoroughly all of the UTIONS on the inside back cover. 2 20 2009, ROSS ONTROLS. ll Rights Reserved.

Sizes 8 to 30 SERPR E-P Double Valves for lutch/rake Kupplung/remse クラッチ / ブレーキ Iaktk@ xfrjks/kd Embreagem/Freio 离合器 / 制动器 Self Monitored - lutch/rake ontrol SOL INPUT OM. SOL INPUT RESET SOL RESET SOL SOL INPUT OM. RESET SOL RESET SOL 3 1 2 3 4 5 6 7 8 9 a b 1 2 3 4 5 6 7 8 9 a b 2 1 c c Dual Input Wiring Diagram Single Input Wiring Diagram During lock-out: Terminals 3 and 7 are connected which allows a panel light, bell, or other electrical device to be wired to terminal 7 and serve as a lockout indicator. Single Input Signal and Dual Input Signal models are available in the E-P series of double valves. oth models can be equipped with, or without, manual overrides. Single input valves require only one main solenoid signal wired into the terminal strip of the E-P monitored double valve. The main solenoid signal is wired into terminal 1 and internally jumpered to the second main solenoid. ommons are wired into terminal 3. This allows both solenoids to be energized and de-energized simultaneously for proper valve operation. Dual Input valves require two solenoid signals wired independently into the terminal strip of the E-P monitored double valve. One main solenoid signal is wired into terminal 1 and the second main solenoid signal is wired into terminal 5. ommons are wired into terminal 3. oth solenoid signals must arrive simultaneously for proper valve operation. Valve Model Number Port Single Signal Input Dual Signal Input vg. V Size Size w/ Overrides w/o Overrides w/ Overrides w/o Overrides In-Out Out-Exh lb (kg) 8 1/2 35734141 35734161 35734341 37534361 3.5 8.5 8.5 (216) 7.2 (184) 11.4 (288) 11.8 (5.3) 8 3/4 35735141 35735161 35735341 35735361 4.0 12 8.5 (216) 7.2 (184) 11.4 (288) 11.8 (5.3) 12 3/4 35735151 35735171 35735351 35735371 8.0 15 8.6 (219) 8.6 (219) 12.0 (303) 15.5 (7.0) 8 1 35736151 35736171 35736351 35736371 4.0 12 8.5 (216) 7.2 (184) 11.4 (288) 11.8 (5.3) 12 1 35736161 35736181 35736361 35736381 8.5 19 8.6 (219) 8.6 (219) 12.0 (303) 15.5 (7.0) 12 11/4 35737161 35737181 35737361 35737381 9.0 21 9.0 (228) 8.5 (216) 12.8 (324) 15.5 (7.0) 30 11/4 35737151 35737171 35737351 35737371 20 42 12.4 (314) 11.1 (282) 17.3 (440) 35.0 (15.8) 30 11/2 35738161 35738181 35738361 35738381 21 43 12.4 (314) 11.1 (282) 17.3 (440) 35.0 (15.8) *NPT standard. For SPP threads, add a D prefix to the model number, e.g., D35734141. 2 inch port size available on size 30 valves. Order part number 1999H77 flange kit separately. STNDRD SPEIFITIONS: For valves on this page. Pilot Solenoids: Two, rated for continuous duty. Standard Voltages: 110 volts D, 24 volts D. Other voltages available. Power onsumption: Each solenoid, 87 V inrush, 30 V holding on 50 or 60 Hz; 14 watts on D. E-P Reset Solenoid: Rated for intermittent duty. Voltages: 24-48 or 100-120 volts or D (for E-P only). mbient Temperature: 40 to 120 F (4 to 50 ). Media Temperature: 40 to 175 F (4 to 80 ). Flow Media: Filtered air; 5 micron recommended. Pressure Range: 30 to 125 psig (2 to 8.5 bar). IMPORTNT NOTE: Please read carefully and thoroughly all of the UTIONS on the inside back cover. www.rosscontrols.com 21

Size 1 & 2 rossflow TM Double Valves* Kupplung/remse クラッチ / ブレーキ Iaktk@ xfrjks/kd Embreagem/Freio 离合器 / 制动器 External Monitoring - lutch/rake ontrol * Non-monitored rossflow TM Size 1 rossflow TM Size 2 Valve ssembly vg. Response onstants Valve Model vg. V Pressure Press. Switch Port Sizes Dimensions inches (mm) F Weight Size Number* 1-2 2-3 Switches** Provision 1 & 2 3 M In-Out Out-Exh. lb (kg) 1 35732632 0.9 1.4 None Yes 1/4 1/4 2.7 (69) 3.3 (84) 5.0 (127) 28 4.6 3.4 2.1 (95) 1 35732640 0.9 1.4 None No 1/4 3/8 2.7 (69) 3.3 (84) 5.0 (127) 24 4.4 3.1 2.1 (95) 1 35732642 0.9 1.4 Two Yes 1/4 1/4 2.7 (69) 3.3 (84) 7.5 (191) 28 4.6 3.4 2.5 (1.14) 1 35732644 1.2 1.7 Two Yes 3/8 3/8 2.7 (69) 3.3 (84) 7.6 (195) 25 3.1 2.8 2.9 (1.32) 1 35732645 1.2 1.7 None Yes 3/8 3/8 2.7 (69) 3.3 (84) 5.1 (130) 25 3.1 2.8 2.5 (1.14) 2 35734620 3.7 6.6 None No 1/2 1/2 3.4 (86) 3.2 (81) 6.3 (160) 30 1.2 1.0 4.3 (1.95) 2 35734632 3.7 6.6 None Yes 1/2 1/2 3.4 (86) 3.2 (81) 6.5 (165) 30 1.2 1.0 4.3 (1.95) 2 35734640 3.7 9.0 None No 1/2 3/4 3.4 (86) 3.2 (81) 6.5 (165) 25 1.1 0.9 4.3 (1.95) 2 35734642 3.7 6.6 Two Yes 1/2 1/2 3.4 (86) 3.2 (81) 9.0 (229) 30 1.2 1.0 4.8 (2.18) 2 35734643 4.2 9.0 None No 3/4 3/4 3.4 (86) 3.2 (81) 6.5 (165) 25 1.1 0.9 4.7 (2.13) 2 35734644 4.2 9.0 Two Yes 3/4 3/4 3.4 (86) 3.2 (81) 9.0 (165) 25 1.1 0.9 5.2 (2.36) 2 35734645 4.2 9.0 None Yes 3/4 3/4 3.4 (86) 3.2 (81) 6.5 (165) 25 1.1 0.9 4.7 (2.13) 2 35734652 3.7 9.0 None Yes 1/2 3/4 3.4 (86) 3.2 (81) 9.0 (165) 25 1.1 0.9 4.3 (1.95) * Model number includes base. For SPP threads, order with a D prefix. For JIS threads, order with a J prefix. Valve and base can be ordered separately; consult ROSS. ** Only valves with pressure switches should be used to control clutch/brake mechanisms on press machinery. The pressure switches must be used in conjunction with a monitoring device to assist with OSH compliance (Ref. 1910.217). Valve Response Time The constants below, designated M and F, can be used to determine the amount of time required to fill or exhaust a volume of any size using the following formula: Vlv. Resp. Time (msec)= M + F *V M= avg. time for parts movement F= msec. per cubic inch of volume V= volume in cubic inches *Pressure Switches & Monitoring: Valves without pressure switches must not be used to control clutch/brake mechanisms on press machinery. Valves with pressure switches must be used in conjunction with an external monitoring device to assist with OSH compliance (Ref. 1910.217). The valves on this page do not have a built-in monitor, and must only be used in conjunction with an external monitoring system. Such monitoring system must be capable of inhibiting the operation of the valve in the event of a failure within the valve. STNDRD SPEIFITIONS: For valves on this page. Pilot Solenoids: Two, rated for continuous duty. Standard Voltages: 110 volts D, 24 volts D. Other voltages available. Power onsumption: Size 1: Each solenoid, 12 V maximum inrush, 9.8 V maximum holding on 50 or 60 Hz; 7.5 watts nominal on D. Size 2: Each solenoid, 8.5 V maximum inrush, 8.5 V maximum holding on 50 or 60 Hz; 6 watts maximum on D. Electrical onnections: Uses two cord-grip connectors at solenoids (order separately). To customer s external monitor Size 1: DIN 43650 Form connector P/N 266K77. Size 2: Din 43650 Form connector P/N 937K87. mbient Temperature: 40 to 120 F (4 to 50 ). Media Temperature: 40 to 175 F (4 to 80 ). Flow Media: Filtered air; 5 micron recommended. Pressure: 40 to 100 psig (2.8 to 7 bar). UTION: If the system must be reset, electrical signals to both solenoids must be removed to prevent the machine from immediately recycling and producing a potentially hazardous condition. IMPORTNT NOTE: Please read carefully and thoroughly all of the UTIONS on the inside back cover. 22 2009, ROSS ONTROLS. ll Rights Reserved.

5/2 r o s smi r r o r Double Valves 5/2 r o s smi r r o r double valve with pressure switch r o s smi r r o r 5/2 Sizes 2 & 4 are G ertified Size 2 Model* Port Sizes V Pressure Replacements* Number 1 2, 3, 4, 5 1-2 1-4 2-3 4-5 Switch lb (kg) Valve No. ase No. 77763410 1/2 3/8 2.0 1.6 1.6 2.8 Without 11.1 (282) 4.1 (104) 3.2 (81) 7.6 (3.4) 77763400 99691 77763411 1/2 3/8 2.0 1.6 1.6 2.8 With 11.1 (282) 6.7 (170) 3.2 (81) 8.4 (3.8) 77763401 99691 * Model number includes base supplied with NPT threads. For SPP threads, order model or base with a D prefix, e.g. D77763410, D99691. For 110 volts add Z suffix to the model number, for 24 volts D add W suffix to the model number, e.g., 77763411Z, 77763401W. Size 4 77764420 3/4 1/2 3.2 3.4 2.7 7.2 Without 12.1 (307) 4.3 (109) 4.1 (104) 10.2 (4.6) 77764400 104991 77764421 3/4 1/2 3.2 3.4 2.7 7.2 With 12.1 (307) 6.9 (175) 4.1 (104) 11.2 (5.1) 77764401 104991 77765410 3/4 3/4 3.2 3.4 2.7 7.2 Without 12.1 (307) 4.3 (109) 4.1 (104) 10.2 (4.6) 77764400 115391 77765411 3/4 3/4 3.2 3.4 2.7 7.2 With 12.1 (307) 6.9 (175) 4.1 (104) 11.2 (5.1) 77764401 115391 * Model number includes base supplied with NPT threads. For SPP threads, order model or base with a D prefix, e.g., D77764420, D104991. For 110 volts add Z suffix to the model number, for 24 volts D add W suffix to the model number, e.g., 77764421Z, 77764401W. Size 4 SE S77764H10 SE 12 SE 12 3.2 3.4 2.7 7.2 Without 12.1 (307) 4.3 (109) 4.1 (104) 10.2 (4.6) 77764400 1159G91 S77764H11 SE 12 SE 12 3.2 3.4 2.7 7.2 With 12.1 (307) 6.9 (175) 4.1 (104) 11.2 (5.1) 77764401 1159G91 * Model number includes base. For 110 volts add Z suffix to the model number, for 24 volts D add W suffix to the model number, e.g., S77764H11Z, 77764401W. Pressure Switches: Pressure switch provides a signal when valve is in a faulted position. Pressure Switch The ROSS 5/2 r o s smirror double valve features: overed by multiple global patents and patents pending Interrelated dual stainless steel precision spool & sleeve construction ase-mounted, four-way, five port, two position design Designed to enable users to comply with current safety regulations Optional pressure switch to provide signal for external monitoring Pilot Valve hambers Pilot Valve PPLITIONS: musement park rides Pinch point applications Die clamp applications Long cylinder stroke applications Shearing equipment This valve is not designed for controlling clutch/brake mechanisms on mechanical power presses. ase ase 1 2 5 4 ir Supply 3 STNDRD SPEIFITIONS: For valves on this page. Pilot Solenoids: Rated for continuous duty. Standard Voltages: 110 volts D, 24 volts D. Other voltages available. Power onsumption: Each solenoid, 18 V inrush, 14 V holding on 50 or 60 Hz; 6 watts on D. Electrical onnections: Uses cord-grip connectors at solenoids. Order connectors separately (see page 25). mbient Temperature: 40 to 120 F (4 to 50 ). Flow Media: Filtered air; 5 micron recommended. Pressure: 40 to 150 psig (2.5 to 10 bar). Media Temperature: 40 to 175 F (4 to 80 ). IMPORTNT NOTE: Please read carefully and thoroughly all of the UTIONS on the inside back cover. www.rosscontrols.com 23

2 fi 11 ccessories Zubehör アクセサリー Lkgk;d midj.k cessórios 辅助配件 Series 19 heck Valves ROSS check valves are self-actuating and designed to provide free air flow in one direction, and to be closed to flow in the opposite direction. X Y Z Valve Port Valve Model vg. Type Size Number* V lb (kg) X 1/8 1968D1005 0.5 2.7 (67) 1.2 (29) 1.0 (25) 0.5 (0.2) 1/4 1968D2005 0.5 2.7 (67) 1.2 (29) 1.0 (25) 0.5 (0.2) 1/4 1968D2001 2.9 2.8 (71) 1.6 (40) 1.4 (35) 0.5 (0.2) Y 3/8 1968D3001 3.7 2.8 (71) 1.6 (40) 1.4 (35) 0.5 (0.2) 1/2 1968D4001 3.9 3.7 (94) 1.5 (40) 1.4 (35) 0.5 (0.2) 1/2 19684107 5.2 4.8 (122) 3.2 (81) 1.8 (46) 0.9 (0.4) 3/4 19685107 8.6 4.8 (122) 3.2 (81) 1.8 (46) 0.9 (0.4) 1 19686117 8.3 4.8 (122) 3.2 (81) 1.8 (46) 0.9 (0.4) 1 19686107 17 5.4 (137) 4.3 (109) 2.3 (58) 2.0 (0.9) Z* 11/4 19687107 22 5.4 (137) 4.3 (109) 2.3 (58) 2.0 (0.9) 11/2 19688117 22 5.4 (137) 4.3 (109) 2.3 (58) 2.0 (0.9) 11/2 19688107 50 7.5 (191) 5.7 (145) 3.5 (89) 4.7 (2.1) 2 19689107 50 7.5 (191) 5.7 (145) 3.5 (89) 4.7 (2.1) 21/2 19689117 50 7.5 (191) 5.7 (145) 3.5 (89) 4.7 (2.1) *NPT port threads. For SPP threads add a D prefix to the model number, e.g., D1968D1005. STNDRD SPEIFITIONS: For valves on this page. mbient/media Temperature: 40 to 175 F (4 to 80 ). Flow Media: Filtered air; 5 micron recommended. Pressure: 5 to 150 psig (0.3 to 10 bar). Signal Pressure: Must be equal to or greater than inlet. MUFFL-IR Silencers ROSS MUFFL-IR silencers substantially reduce exhaust noise levels yet produce little back pressure. Typical impact noise reduction is in the 20 25 d range. MUFFL-IR Silencer male threads illustrated Male Pipe Threads For ports 1/8 through 11/4 Female Pipe Threads For ports 11/4 through 21/2 Port NPT Model verage Size Threads Number* V lb (kg) 1/8 Male 55001003 2.0 0.8 (21) 2.2 (56) 0.3 (0.1) 1/4 Male 55002003 2.0 0.8 (21) 2.2 (56) 0.3 (0.1) 3/8 Male 55003013 2.0 0.8 (21) 2.2 (56) 0.3 (0.1) 3/8 Male 55003003 5.7 1.3 (32) 3.8 (96) 0.5 (0.2) 1/2 Male 55004003 7.0 1.3 (32) 3.8 (96) 0.5 (0.2) 3/4 Male 55005013 7.0 1.3 (32) 3.8 (96) 0.5 (0.2) 3/4 Male 55005003 15 2.0 (51) 5.6 (142) 1.5 (0.7) 1 Male 55006003 18 2.0 (51) 5.6 (142) 1.5 (0.7) 11/4 Male 55007013 18 2.0 (51) 5.6 (142) 1.5 (0.7) 11/4 Female 55007001 37 2.5 (64) 5.9 (149) 2.3 (1.0) 11/2 Female 55008001 38 2.5 (64) 5.9 (149) 2.3 (1.0) 2 Female 55009001 50 3.0 (77) 7.3 (185) 3.5 (1.6) 21/2 Female 55009002 65 4.0 (102) 6.9 (173) 3.5 (1.6) *NPT port threads. For SPP threads add a D prefix to the model number, e.g., D55001003. Pressure Range: 150 psig (10 bar) maximum. Pressure Gauges Port Size Model Number* Range psig (bar) Diameter inches (mm) 3 4 1 5 0 40 60 20 0 6 80 7 100 lb/in 2 bar 8 120 140 9 160 180 200 14 10 13 12 1/8 54001002 0-160 (0-11) 1.7 (43) 1/4 54002010 0-60 (0-4) 2.2 (56) 1/4 54002011 0-200 (0-14) 2.2 (56) 1/4 54002012 0-300 (0-21) 2.2 (56) *NPT port threads. For SPP threads add a D prefix to the model number, e.g., D54001002. IMPORTNT NOTE: Please read carefully and thoroughly all of the UTIONS on the inside back cover. 24 2009, ROSS ONTROLS. ll Rights Reserved.

ccessories Zubehör アクセサリー Lkgk;d midj.k cessórios 辅助配件 all Valves (2/2) hrome plated ball lowout-proof stem w/adjustable packing RTFE seats and seals Pressure range: 29 Hg to 600 psig Temperature range: 35 to 400 F Locking/Relieving all Valves (3/2) hrome plated ball lowout-proof stem w/adjustable packing RTFE seats and seals Pressure range: 29 Hg to 600 psig Temperature range: 35 to 400 F *NPT Only *NPT Only Model Number* 1/4 164H74 3/8 165H74 1/2 166H74 3/4 167H74 1 168H74 11/4 169H74 11/2 170H74 2 171H74 Model Number* 1/4 172H74 3/8 173H74 1/2 174H74 3/4 175H74 1 176H74 11/4 177H74 11/2 178H74 2 179H74 Liquid Filled Gauges Liquid filled ase: Stainless steel, 2 1/2 diameter Scale: Dual (Lb/in 2 bar x100 kpa) Dial range: 0 to 160 psig ourdon tube type: NSI grade onnection: rass 1/4 NPT center back mount Surge protector: Standard DIN Form Electrical onnectors WIRED ONNETORS have 2 meter (61/2 ft) cord with three 18 gauge conductors. ord exits upward, and is available in either 6 mm or 10 mm diameter. Safety Relief Valve djustable setpoint pressure range: 2 to 300 psig (factory set at 125 psig) ronze construction Plated steel spring, washers, stem, lever luminum alloy cap Teflon PF flourocarbon seat 1 NPT Maximum temperature: 400 F Male Model Number 54002014 (NPT) D54002014 (SPP) Part Numbers of Form Electrical onnectors onnector Type Without Light With Light* For use with dropcord (ord not included) 937K87 936K87* Wired with 6-mm cord 721K77 720K77* Wired with 10-mm cord 371K77 383K77* For use with threaded conduit 723K77 724K77* Part Numbers of Form Electrical onnectors onnector Type Without Light With Light* For use with dropcord 266K77 267K77* (ord not included) *Specify solenoid voltage when ordering. Model Number 111H74-125 (125 psi max.) NPT 111H74-150 (150 psi max.) NPT 111H74-230 (230 psi max.) NPT D111H74-125 (125 psi max.) SPP D111H74-150 (150 psi max.) SPP D111H74-230 (230 psi max.) SPP www.rosscontrols.com 25

ccessories Zubehör アクセサリー Lkgk;d midj.k cessórios 辅助配件 Pressure Switches 3 to 150 psi pressure range (adjustable) 475 psi maximum pressure High shock resistance & set point stability SPDT double break contacts NEM 4, 13 enclosure Diaphragm actuated Non-adjustable differential Numerical range scale window UL and S listed Indicator light 5 pin mini-connector Model Number 717H30* (NPT) D717H30* (SPP) *Specify voltage when ordering. 1/4 NPT Female inlet Visual Pop-Up Indicator or Pressure Switch (electrical) May be installed on all L-O-X valves with pressure sensing port Provides a means to verify the release of downstream pressure to next obstruction Verification Option Model Number Port Size* Pop-Up Indicator 98830 1/8 Pressure Switch 58686 1/8 * Pressure sensing port threads are NPT on all L-O-X valves models. (including SPP) Gauge Shut-Off llows gauge installation without system shutdown Male-female ported for compact installation Nickel plated brass construction Rated to 250 psi Junction ox 1/4 NPT female Model Number 112H74 1/4 NPT male 6 x 10 X 4 deep 20 pre-mounted terminals NEM 12 construction Model Number 608F94 Three Function Transducer with Integral Pressure Switch and Digital Gauge Pressure setpoint range Overpressure limit urst pressure Port connection Supply voltage Status indicators Outputs Switch point accuracy Programmable switch delay Repeatability Wetted parts Protection rating Electrical connections 7.5 to 150 psi 700 psi 2000 psi 1/4 NPT female 18 to 30 volts D 1 red LED: switched output status, 3 numeric LEDs: system pressure Programmable NO or N (with window function) & 4 20 m output + 1.5% of full range 0 to 50 seconds + 0.25% of full range 304 stainless steel, ceramic cell, Viton O-ring NEM 3, 4, 12, 13, IP65 Quick disconnect MIRO D type Single Function Unit Transducer Only: 935H30 5 Meter ord: 936H30 Model Number 911H30 26 2009, ROSS ONTROLS. ll Rights Reserved.

PRE-INSTLLTION or SERVIE 1. efore servicing a valve or other pneumatic component, be sure that all sources of energy are turned off, the entire pneumatic system is shut off and exhausted, and all power sources are locked-out (ref: OSH 1910.147, EN 1037). 2. ll ROSS products, including service kits and parts, should be installed and/or serviced only by persons having training and experience with pneumatic equipment. ecause any installation can be tampered with or need servicing after installation, persons responsible for the safety of others or the care of equipment must check every installation on a regular basis and perform all necessary maintenance. 3. ll applicable instructions should be read and complied with before using any fluid power system in order to prevent harm to persons or equipment. In addition, overhauled or serviced valves must be functionally tested prior to installation and use. 4. Each ROSS product should be used within its specification limits. In addition, use only ROSS parts to repair ROSS products. Failure to follow these directions can adversely affect the performance of the product or result in the potential for human injury. FILTRTION and LURITION 5. Dirt, scale, moisture, etc. are present in virtually every air system. lthough some valves are more tolerant of these contaminants than others, best performance will be realized if a filter is installed to clean the air supply, thus preventing contaminants from interfering with the proper performance of the equipment. ROSS recommends a filter with a 5-micron rating for normal applications. 6. ll standard ROSS filters and lubricators with polycarbonate plastic bowls are designed for compressed air applications only. Do not fail to use the metal bowl guard, where provided, to minimize danger from high pressure fragmentation in the event of bowl failure. Do not expose these products to certain fluids, such as alcohol or liquefied petroleum gas, as they can cause bowls to rupture, creating a combustible condition, hazardous leakage, and the potential for human injury. Immediately replace a crazed, cracked, or deteriorated bowl. When bowl gets dirty, replace it or wipe it with a clean dry cloth. autions Warranty 7. Only use lubricants which are compatible with materials used in the valves and other components in the system. Normally, compatible lubricants are petroleum base oils with oxidation inhibitors, an aniline point between 180 F (82 ) and 220 F (104 ), and an ISO 32, or lighter, viscosity. void oils with phosphate type additives which can harm polyurethane components, potentially leading to valve failure and/or human injury. If you have questions regarding whether a lubricant used on your system is compatible with ROSS products, please contact ROSS. VOID INTKE/EXHUST RESTRITION 8. Do not restrict the air flow in the supply line. To do so could reduce the pressure of the supply air below the minimum requirements for the valve and thereby cause erratic action. 9. Do not restrict a valve s exhaust port as this can adversely affect its operation. Exhaust silencers must be resistant to clogging and have flow capacities at least as great as the exhaust capacities of the valves. ontamination of the silencer can result in reduced flow and increased back pressure. ROSS expressly disclaims all warranties and responsibility for any unsatisfactory performance or injuries caused by the use of the wrong type, wrong size, or inadequately maintained silencer installed with a ROSS product. POWER PRESSES 10. Mechanical power presses and other potentially hazardous machinery using a pneumatically controlled clutch and brake mechanism must use a press control double valve with a monitoring device. double valve without a self-contained monitoring device should be used only in conjunction with a control system which assures monitoring of the valve. ll double valve installations involving hazardous applications should incorporate a monitoring system which inhibits further operation of the valve and machine in the event of a failure within the valve mechanism. ENERGY ISOLTION/EMERGENY STOP 11. Per specifications and regulations, ROSS L-O-X and manual L-O-X with EEZ-ON operation products are defined as energy isolation devices, NOT S EMERGENY STOP DEVIES. Products manufactured by ROSS are warranted to be free of defects in material and workmanship for a period of one year from the date of purchase. ROSS obligation under this warranty is limited to repair or replacement of the product or refund of the purchase price paid solely at the discretion of ROSS and provided such product is returned to ROSS freight prepaid and upon examination by ROSS such product is found to be defective. This warranty shall be void in the event that product has been subject to misuse, misapplication, improper maintenance, modification or tampering. THE WRRNTY EXPRESSED OVE IS IN LIEU OF ND EXLUSIVE OF LL OTHER WRRNTIES ND ROSS EXPRESSLY DISLIMS LL OTHER WRRNTIES EITHER EXPRESSED OR IMPLIED WITH RESPET TO MERHNTILITY OR FITNESS FOR PRTIULR PURPOSE. ROSS MKES NO WRRNTY WITH RESPET TO ITS PRODUTS MEETING THE PROVISIONS OF NY GOVERNMENTL OUPTIONL SFETY ND/OR HELTH LWS OR REGULTIONS. IN NO EVENT SHLL ROSS E LILE TO PURHSER, USER, THEIR EMPLOYEES OR OTHERS FOR INIDENTL OR ONSEQUENTIL DMGES WHIH MY RESULT FROM REH OF THE WRRNTY DESRIED OVE OR THE USE OR MISUSE OF THE PRODUTS. NO STTEMENT OF NY REPRESENTTIVE OR EMPLOYEE OF ROSS SHLL EXTEND THE LIILITY OF ROSS S SET FORTH HEREIN. www.rosscontrols.com 27

GLOL Reach with a LOL Touch sm ROSS ONTROLS Troy, MI., U.S.. Telephone: + 1-248-764-1800 Fax: + 1-248-764-1850 In the United States: ustomer Service: 1-800-GET ROSS (438-7677) Technical Service: 1-888-TEK-ROSS (835-7677) www.rosscontrols.com ROSS EUROP GmbH Langen, Germany Telephone: + 49-6103-7597-0 Fax: + 49-6103-74694 Email: info@rosseuropa.com www.rosseuropa.com ROSS SI K.K. Kanagawa, Japan Telephone: + 81-427-78-7251 Fax: + 81-427-78-7256 www.rossasia.co.jp ROSS UK Ltd. irmingham, United Kingdom Telephone: + 44-121-559-4900 Fax: + 44-121-559-5309 Email: sales@rossuk.co.uk ROSS SOUTH MERI Ltda. São Paulo, razil EP 09725-020 Telephone: + 55-11-4335-2200 Fax: + 55-11-4335-3888 Email: vendas@ross-sulamerica.com.br DIMFLUID s.a.s. Saint Ouen, France Telephone: + 33-01-49-45-65-65 Fax: + 33-01-49-45-65-30 Email: dimafluid@dimafluid.com www.dimafluid.com ROSS ONTROLS (HIN) Ltd. Shanghai, hina Telephone: + 86-21-6915-7951 Fax: + 86-21-6915-7960 Email: alvinzhurong@vip.163.com Your local ROSS distributor is: ROSS ONTROLS INDI Pvt. Ltd. hennai, India Telephone: + 91-44-2624-9040 Fax: + 91-44-2625-8730 Email: rossindia@airtelbroadband.in There are ROSS Distributors Throughout the World To meet your requirements across the globe, ROSS distributors are located throughout the world. Through ROSS or its distributors, guidance is available for the selection of ROSS products, both for those using pneumatic components for the first time and those designing complex pneumatic systems. This catalog presents an overview of the extensive ROSS product line. Other literature is available for engineering, maintenance, and service requirements. If you need products or specifications not shown here, please contact ROSS or your ROSS distributor. They will be happy to assist you in selecting the best product for your application. Printed in the U.S.. - Rev. 11/09 Supersedes all previous editions of 450 bulletins. 2009, ROSS ONTROLS. ll Rights Reserved. Form 10155