with cable Model PA-mmm Simplifies switch wiring. Wide variety of connectors attached to cables. No wiring or staking work needed Shorter replacement time in unlikely event of switch malfunction Simultaneous mechanical assembly and electrical wiring Perfect for flexible production lines Usable even in harsh environments exposed to cutting oil (IP67) PA COMBINATIONS Switch side Wiring side (PA side) switch Cable with female connectors () SX Limit switch Proximity switch () LX Switches with preleaded connector Cable with tandem connectors SB () SN () LB General switches and actuators Cable with male connectors () Standard basic switch BX LN () Solenoid valve Pressure switch, flow switch, motor, etc. s for panel mounting Mounting () Panel V1 1
SELECTION GUIDE Example:PA-JSXHK-E PA- J SX HK-E Basic model number of wires Type shape PA- J I SX LX BX SB SN LB LN V1 0 0 HK-E SK CK *1. For lengths not listed, two cores, or cable for AC use, contact a branch or sales office. *. The 0.-m cable length can only be used with connector shape BX. *. s are not available with a CK cable. Description PA Series cable with connector cores AC (wire colors: brown, white, blue, black) (wire colors: brown, white, blue, black) (female) (female)* (male) (female)- straight (male) (female) - angle (male)* (female) - straight (male)* (female) - angle (male)* Panel mounting 0. m 0. m m m m m Dia. 6.0 oil-resistant vinyl insulated cable Vinyl insulated cable, high oil & vibration resistance, UL/NFPA79CM, CL Cable with polyurethane resin insulation, high oil & vibration resistance ORDER GUIDE PA- HK-E Series (mm ) Oil-resistant vinyl cabtyre cable / / / / 6.0 dia. 0. (0/0.08) 0. 0. PA-IBX0HK-E PA-IBX0HK-E PA-ISXHK-E PA-ISXHK-E PA-ISXHK-E PA-ISXHK-E PA-ILXHK-E PA-ILXHK-E PA-ISBHK-E PA-ISBHK-E PA-ISBHK-E PA-ILNHK-E PA-ILNHK-E PA-ISNHK-E PA-ISNHK-E PA-ILBHK-E PA-ILBHK-E
PA- SK Series (mm ) Vinyl-insulated cord with high resistance to oil and vibration (UL/NFPA79 CM, CL) / / / / 6.1 dia. 0. (8/0.08) 0. 0. PA-IBX0SK PA-IBX0SK PA-ISXSK PA-ISXSK PA-ISXSK PA-ISXSK PA-ILXSK PA-ILXSK PA-ISBSK PA-ISBSK PA-ISBSK PA-ISBSK PA-ILNSK PA-ILNSK PA-ISNSK PA-ISNSK PA-ILBSK PA-ILBSK PA- CK Series (mm ) Cable with polyurethane resin insulation, high oil & vibration resistance / 6.0 dia. 0. (1/0.08) 1 1 PA-ISX1CK PA-ISXCK PA-ISXCK PA-ISXCK PA-ISXCK PA-ISB1CK PA-ISBCK PA-ISBCK PA-ISBCK PA-ISBCK
Cables with male connectors (mm ) Terminal Oil-resistant vinyl cabtyre cable Cable with polyurethane resin insulation, high oil & vibration resistance 6.0 dia. 0. (0/0.08) 0. (1/0.08) 0. 0. 0. PA-IBX0HK PA-IBX0SK PA-IBX0CK For M ( dia. terminal) Panel-mounted connector (mm ) AC AWG0 (0. mm ) 0. PA-JV1K PA-IV1K APPLICATION EXAMPLES Lower maintenance costs due to faster replacement of switches Old way of wiring Existing switch Wiring with the PA Quick-connection switch (when connector- limit switch is used) Wiring and staking operation PA connector Easy screw-in connection
CONNECTOR SPECIFICATIONS*1 Item Operating voltage and current Insulation resistance Dielectric strength Initial contact resistance Mating/unmating force Mating cycles nut torque Cable pullout strength Vibration resistance Shock resistance Protective structure Operating temperature Operating humidity Material Specifications AC : Vac ma min., 0 Vac A : Vdc ma min., 1 Vdc A max. 0 MΩ min. (by 00 Vdc megger) 1,00 Vdc for 1 minute (across contacts, and between contacts and connector housing) 0 mω max. (excluding cable conductor-intrinsic resistance; at A with male-female contact combination) 0. to.0 N (per contact) 0 times 0.8 N m min.* 0 N min. to Hz, 1. mm peak-to-peak amplitude, hrs each in X, Y, and Z s 00 m/s, times each in X, Y and Z s IP67 (IP6 for panel-mounted ) to +70 C 9% RH max. Contacts: gold-plated brass Contact holder: glass-lined polyester resin Housing: polyester elastomer (panel-mounted : aluminum) Lock ring: Orange brass (for AC), Ni-plated brass (for ) Coupling: Orange brass (for AC), Ni-plated brass (for ) O-ring: NBR *1. Specifications assume Azbil male/female connectors. *. The recommended tightening torque is 0. to 0.6 N m. If fastened poorly, the IP67 protection may be lost, or the connector may come loose. CABLE SPECIFICATIONS Item Type of cable Sheath color PA-J PA-I 6.0 mm HK Oil-resistant vinyl insulated cable 0. mm (0/0.18) Gray PA-J PA-I 6.1 mm Vinyl-insulated cord with high resistance to oil and vibration (UL/NFPA79 CM, CL) Gray SK PA-I CK 6.0 mm Flexible oil-resistant andflame-resistant fluorine rubber cabtyre cable 0. mm (8/0.08) 0. mm (1/0.08) Black
CONNECTOR SHAPES SX LX BX SB SN LB LN Panel-mounted connector : AC, (J ), (I ) Lead colors: brown, white, blue, black PA- Gold-plated contacts Panel-mounted connector J: AC I : V1 K shape Appearance (L) V1 AC 0. m PA-JV1K PA-IV1K Contact arrangement and lead colors for male/female connectors side side For ac For dc For ac For dc Contact No. 1 Lead colors Brown White Blue Black 6
EXTERNAL DIMENSIONS OF CONNECTORS ( cables are shown) (female) Cord : H.S (male) (unit: mm) 1 dia. 1 dia. 1 dia. M1 1 dia. Cord : C (female) (male) Panel-mounted connector, catalog listing PA- V1K A: 18 dia. 0 dia. 1.6 dia. O-ring: 16 dia. x 1. dia. Lead wires: heat-resistant vinyl-insulated wire (UL style 07), AWG0 (0.0 mm), insulation external dia.. mm max. Brown. White Blue Black Panel cutout dimensions 1. dia. Panel thickness : 1 to mm Recommended mounting centers: 6 mm (suitable for socket wrench) 7
DIMENSIONS WHEN CONNECTED TO CONNECTOR-TYPE SWITCH (unit: mm) The dimensions below apply when the connector is attached. Add space for insertion/disconnection (approx. 1 mm) during actual fitting. - proximity switch with angle- PA Connection to connector- proximity switch (FL7M) For attachment to an angle PA, calculate the total length as follows: Total length = A + 0 mm - limit switch Connection to angle- PA - limit switch with straight PA Note: When a connector- switch and angle- PA are connected, the in which the PA cable exits may differ. Pay attention to this. PRECAUTIONS FOR USE Tightening the connector nut/lock ring Take special care if the mating part is made of resin, since the threads can easily be damaged when the connector is first tightened. When assembling the connector, align the center of the cores, push in as far as possible, and tighten. Tighten firmly by hand. The recommended tightening torque is 0. to 0.6 N m. The use of a tightening tool may damage the connector. When securing the lock ring of a PA- V1K, close firmly (0. to 0.6 N m) by hand, or using the dedicated tool. If the connector is not tightened firmly, IP67 protection may be lost, or the connector may come loose. Inserting and removing connectors Before inserting or removing connectors, be sure to turn the power OFF. When removing connectors, do not pull by the cable. Hold the connector by its body when removing. Cautions when bending cables The minimum bend radius of the cable is 80 mm. Make allowance for bends in the cable. R = 80 mm Protective structure IP67 does not imply complete waterproofing. Do not use where constantly exposed to water. Avoid use where external force (or weight) is applied continuously on the connecting section of the connector. The body is molded resin. Do not step on the body or place heavy objects on it. Inserting and removing connectors The of the angle plug is restricted by the groove in the opposing plug. When using LX, NX, SX, LB, or LN series connectors, check the position of the groove in the opposing plug. Cautions during replacement When removing connectors to replace the switch or cable, thoroughly wipe the connector and surrounding area to remove any water. After removing the connector, prevent it from being immersed in chemicals or powder, or being dropped. If the connector is accidentally immersed in liquid, allow it to dry completely before connecting again. If the connector is dropped in powder, completely wipe off any powder before connecting again. Failure to observe the above may result in short circuits or poor connections. 8