Equivalency Evaluation to 2010 FBC

Similar documents
Equivalency Evaluation to 2010 FBC

Product Evaluation Report

Submittal Requirements for Product Evaluation - Doors

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: VELUX AMERICA LLC POST OFFICE 5001 GREENWOOD, SOUTH CAROLINA 29648


ESR ICC Evaluation Service, Inc. Issued December 1, 2006 This report is subject to re-examination in one year.

CREEK Technical Services, LLC

CREEK Technical Services, LLC

American National Standard

GENERATOR SHELTER IMPACT TEST REPORT (.08 Material)

New Gateway 101/I.S.2/A440

Residential skylight sizes 2008 edition

Kolbe Teutonic Series Air-Water-Structural Test Reports Manual

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: NATURAL LIGHT ENERGY SYSTEMS

3948 Townsfair Way, Suite 200 July 2013 Columbus, Ohio Toll Free Website

Euro Vista Pivot. Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL FOLDING SLIDING STACKING PIVOT

SUMMARY OF PROPOSED CHANGES,

DASMA DASMA

CITY OF LOS ANGELES CALIFORNIA

William R. Heiden III, P.E.

Euro Vista Pivot FPA HVHZ AMIA MI-DA DE H V HZ AFLO RIDA PRO D UC T

Not to be distributed outside of FM Approvals and its affiliates except by Customer

AAMA/WDMA/CSA 101/I.S.2/A NAFS North American Fenestration Standard/Specification for windows, doors, and skylights

Contents. Preface 6. 1 Scope General Outside of scope Terminology Units of measurement 13 1.

Louver Products Severe Duty, Stationary, Operable

EURO VISTA FOLD. Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL FOLDING SLIDING STACKING PIVOT

Code Compliance Research Report CCRR-0258

PREMIUM QUALITY VINYL WINDOWS & DOORS

FIBERGLASS DOORS for the Door Shop

DIVISION: METALS SECTION: COLD-FORMED METAL FRAMING REPORT HOLDER: WARE INDUSTRIES D/B/A MARINO\WARE

STANDARD FOR ROLLING SHEET DOORS

continuous mounting flange intended for direct attachment to roofing substrate.

%"!#!#%&'!# %##(%)"&#%$!!%'"%!'*%% SW 26 Street, Room 208,%! '#%# - '

PRODUCT EVALUATION Effective Date: July 1, 2014 RC-20

IMPACT RATED WINDSERT DOOR SYSTEM

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

Guide Specification SECTION VINYL WINDOWS

H U R R I C A N E R A T E D G A R A G E D O O R S

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

SFI SPECIFICATION 14.3 EFFECTIVE: AUGUST 25, 2017 *

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here)

Meeting ENERGY STAR Version 6.0

5400 Armor Max Plus Windows Maximum Impact Protection

Euro Vista Slide FPA HVHZ AMIA MI-DA DE H V HZ AFLO RIDA PRO D UC T

/TRA BuyLine 1561

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 *

ENLIGHTENED LIVING RESIDENTIAL SKYLIGHTS E-CLASS CURB-MOUNT ARCHITECTURAL SERIES

Table of Contents. 11 Line Bored Lock. Specifications. Certification Compliance. On the Cover

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: SPECIALTY WHOLESALE SUPPLY

HURRICANE RATED GARAGE DOORS

Euro Vista Multi Slide

Originally Issued: 09/26/2012 Revised: 09/29/2017 Valid Through: 09/30/2018

For BIS Use Only Doc: CED 50(7436) BUREAU OF INDIAN STANDARDS

SFI SPECIFICATION 39.2 EFFECTIVE: August 25, 2017 *

06 November /13675-R. Mr. Julian Reusing President & CEO GoliathTech Inc. 175B, rue Peladeau Magog, QC J1X 5G9. Dear Mr.

AAMA/WDMA/CSA 101/I.S.2/A440-08

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS

ORDER OF THE LIEUTENANT GOVERNOR IN COUNCIL

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued May 1, Legacy report on the 1997 Uniform Building Code

SFI SPECIFICATION 7.2 EFFECTIVE: DECEMBER 15, 2006 *

Draft Indian Standard SAFES Part 1 Specification (Fifth Revision)

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

PERFORMANCE TEST REPORT. Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent

FLEMING-BARON DOOR PRODUCTS 101 Ashbridge Circle Woodbridge, Ontario L4L 3R5 UL CERTIFIED HURRICANE RESISTANT DOOR & FRAME PRODUCT

Workforce Development Learning Center Course Outline. Emergency Vehicle Driving FIP 3601

WinGuard A M E R I C A S # 1 B R A N D O F I M P A C T - R E S I S T A N T W I N D O W S + D O O R S

AAMA/WDMA/CSA 101/I.S.2/A440-08

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: SS 145.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

INTEROFFICE MEMORANDUM

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: CR LAURENCE CO., INC.

Superior by Design. Euro vista wood impact/non impact rated wood folding door systems

TITLE 16. TRANSPORTATION CHAPTER 27. TRAFFIC REGULATIONS AND TRAFFIC CONTROL DEVICES

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket

532: 2006 Bicycle tube valves and valve tubing Specification (third revision) 2414: 2005 Cycle and rickshaw pneumatic tyres (fourth revision)

Structurlam Mass Timber Corporation Revised October 11, 2018

Evaluation Report CCMC R Ram Jack Helical Foundation Systems and Devices

No skylight under the sun can outperform our solid-state system.

New $1500 Stimulus Plan Tax Credit

PRODUCT EVALUATION REPORT

Table of Contents. 11 Line Bored Lock. On the Cover

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

SFI SPECIFICATION 1.2 EFFECTIVE: FEBRUARY 9, 2006* PRODUCT: Multiple Disc Clutch Assemblies for Vehicles with Naturally Aspirated Engines

SFI SPECIFICATION 28.3 EFFECTIVE: APRIL 21, 2014 *

Centrifugal Roof Downblast Exhaust Fans

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

Centrifugal Roof Downblast Exhaust Fans

SFI SPECIFICATION 4.2 EFFECTIVE: OCTOBER 26, 1994*

AGREEMENT. (Revision 2, including the amendments entered into force on 16 October 1995) Addendum 102: Regulation No. 103

DEPARTMENT OF TRANSPORTATION FEDERAL AVIATION ADMINISTRATION TYPE CERTIFICATE DATA SHEET NO. A11EA

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

RETROFIT OF WINDOWS & DOORS (WINDLOAD PRESSURES)

StyleGuard IMPACT- When the storm is at its worst, our performance is at its best. RESISTANT WINDOWS DOORS AND

SFI SPECIFICATION 32.1 EFFECTIVE: MARCH 24, 2009 *

StyleGuard. Impact-Resistant Windows and Doors Edition

SINGLE SLIDING WINDOW 1000 SERIES 4-1/2" FRAME SINGLE SLIDER LIFT OUT

Cylindrical Lever Locks

Transcription:

Equivalency Evaluation to 2010 FBC Date: PTC Report No.: Report Revision No.: PTC Project No.: Product Mfg.: Product Name: Product Category: Product Sub-Category: Compliance Method: Prepared By: December 10, 2013 2270-EER 0 413-1014 Solatube International, Inc. 2210 Oak Ridge Way Vista, CA 92081 Solatube M74 DS Curb Mount Open Ceiling TDD with Amplifier - Dual Glazed Solatube M74 DS Curb Mount Open Ceiling TDD with Amplifier - Single Glazed Sky Lights Skylight Product Approval Rule 61G20-3.015 Equivalency of Standards Robert J. Amoruso, P.E. Florida P.E. License Number 49752 CERTIFICATE OF INDEPENDENCE and Robert J. Amoruso, P.E. do not have, nor will acquire, any financial interest in the company manufacturing or distributing product(s) covered by this Product Evaluation Report. and Robert J. Amoruso, P.E. do not have, nor will acquire any financial interest in any other entity involved in the approval process or testing of the product(s) covered by this Product Evaluation Report. Page 1

Project Scope Evaluate equivalency of testing standards used for the performance testing of Solatube M74 DS Curb Mount Open Ceiling TDD - Dual Glazed for conformance to the 2010 Florida Building Code Building and Residential Volumes excluding the High Velocity Hurricane Zone (HVHZ) and Solatube M74 DS Curb Mount Open Ceiling TDD - Single Glazed Tubular Daylight Devices for conformance to the 2010 Florida Building Code Building and Residential Volumes including the High Velocity Hurricane Zone (HVHZ). Description of Product Installation Requirements See Reference 1 for a description of the product, its installation and other pertinent data related to its approved use. Performance and Testing Standards Reference 2.a conducted air, water and structural testing including impact and cyclic loading to the following standard(s). 1. AAMA/WDMA/CSA 101/I.S.2/A440-08, North American Fenestration Standard/Specification for windows, doors, and skylights. 2. AAMA/WDMA/CSA 101/I.S.2/A440-11, North American Fenestration Standard/Specification for windows, doors, and skylights. 3. ASTM E1886-05, Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials. 4. ASTM E1996-02, Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters Impacted by Windborne Debris in Hurricanes. 5. ASTM E1996-05, Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes. 6. ASTM E1996-06, Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes. 7. ASTM E1996-09, Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes. 8. TAS201-94, Impact Test Procedures. 9. TAS202-94, Criteria for Testing Impact & Non-Impact Resistant Building Envelope Components Using Uniform Static Air Pressure. 10. TAS203-94, Criteria for Testing Products Subjected to Cyclic Wind Pressure Loading. Reference 2.b.i conducted plastic testing to the following standard(s). 1. ASTM D638-03, Standard Test Method for Tensile Properties of Plastics 2. ASTM D638-06, Standard Test Method for Tensile Properties of Plastics Page 2

3. ASTM D1929-96 (2001)e1, Standard Test Method for Determining Ignition Temperature of Plastics. 4. ASTM D1929-12, Standard Test Method for Determining Ignition Temperature of Plastics. 5. ASTM D2843-99(2004), Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics. 6. ASTM D2843-10, Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics. 7. ASTM E84-04, Standard Test Method for Surface Burning Characteristics of Building Materials Reference 2.b.ii conducted plastics testing to the following standard(s) in which NOA No. NOA 12-0605.05 confirms that plastic testing meets the 2010 FBC/FRC. 1. ASTM D638, Standard Test Method for Tensile Properties of Plastics 2. ASTM D1929, Standard Test Method for Determining Ignition Temperature of Plastics. 3. ASTM D2843, Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics. References and Supporting Documents 1) Drawings a. SOLA0011, Rev. 0, dated 12/10/13, Solatube M74 DS Curb Mount TDD with Amplifier - Dual Glazed Installation Anchorage Details. b. SOLA0012, Rev. 0, dated 12/10/13, Solatube M74 DS Curb Mount TDD with Amplifier - Single Glazed Installation Anchorage Details. 2) Testing a. Performance Testing i. Architectural Testing Inc. Test Report No. C5760.02-301-44-R4, dated 10/14/13, Solatube M74 DS-O-DP-FC-L2-REG & M74 DS-O-DPP-FC-L2-REG Tubular Daylight Device testing to AAMA/WDMA/CSA 101/I.S.2/A440-08 AND AAMA/WDMA/CSA 101/I.S.2/A440-11 - Solatube M74 DS Curb Mount Open Ceiling TDD - Single and Dual Glazed ii. Architectural Testing Inc. Test Report No. C5760.03-301-44-R4, dated 10/14/13, Solatube M74 DS-O-DP-FC-L2-REG & M74 DS-O-DPP-FC-L2-REG Tubular Daylight Device testing to ASTM E1886-05 and ASTM E1996-02/05/06/09 - Solatube M74 DS Curb Mount Open Ceiling TDD - Single and Dual Glazed iii. Architectural Testing Inc. Test Report No. C5760.05-301-18-R2, dated 10/14/13, Solatube M74 DS-O-DP-FC-L2-REG Tubular Daylight Device testing to TAS 201, TAS 202 and TAS 203 - Solatube M74 DS Curb Mount Open Ceiling TDD - Single Glazed b. Plastics Testing i. International Code Council Evaluation Services Evaluation Reports 1. ICC-ES ESR-1407 2. ICC-ES ESR-1864 3. ICC-ES ESR-1659 Page 3

4. ICC-ES ESR-2590 ii. Miami-Dade Product Control Notice of Acceptance (NOA) No. 1. NOA 12-0605.05 3) Reports a. PTC Report No. 2270, Rev. 0, Solatube M74 DS Curb Mount Open Ceiling TDD with Amplifier Product Evaluation to the 2010 FBC, Dated 12/10/13, signed and sealed by Robert J. Amoruso, P.E. 4) 2010 Florida Building Code & 2010 Florida Residential Code a. Testing and Labeling Requirements i. Section 1606.1.2 Opening Protection ii. Section R301.2.1.2 Opening Protection iii. Section 1715.5.2.1.1 Testing and Labeling of Skylights iv. Section 1715.5.2.1.2 Skylights and Sloped Glazing v. Section R308.6.9 Testing and labeling of skylights vi. Section 2610 Light-Transmitting Plastic Skylight Glazing vii. Section 2610.2 Light-Transmitting Plastic Skylight Glazing, Mounting viii. Section R308.6.8 Curbs for skylights. b. Glazing Requirements i. Section 2405.1 Sloped Glazing and Skylights - Scope ii. Section 2405.2 Allowable Glazing Materials and Limitations iii. Section R308.6 Skylights and Sloped Glazing c. Plastics Requirements (HVHZ requirements shown for information only) i. Section 2603.3 Foam Plastic Insulation ii. Section 2606.4 Specifications, Light-transmitting plastics iii. Section 2612.2/R4412.1.2 Definitions, Approved Plastics Page 4

Equivalency Evaluation Air, Water and Structural; Impact and Cyclic Performance testing meets one or more of the adopted 2010 Florida Building Code and 2010 Florida Residential Code. For product evaluation and product approval, the following code adopted testing standard versions will be used. 1) AAMA/WDMA/CSA 101/I.S.2/A440-08 2) ASTM E1886-05 3) ASTM E1996-09 4) TAS 201-94, TAS 202-94 and TAS 203-94 based on 2010 FBC/FRC (see reference 2.a.iii for testing). Solatube TDD Performance Testing Testing Standard Standard Revision Level Florida Building Code 2010 FBC 2010 FRC AAMA/WDMA/CSA 101/I.S.2/A440 08 05 & 08 08 AAMA/WDMA/CSA 101/I.S.2/A440 11 05 & 08 08 ASTM E1886 05 05 05 ASTM E1996 02 02, 06 & 09 02, 06 & 09 ASTM E1996 05 02, 06 & 09 02, 06 & 09 ASTM E1996 06 02, 06 & 09 02, 06 & 09 ASTM E1996 09 02, 06 & 09 02, 06 & 09 Equivalency Evaluation Plastics Testing The changes in revision level of the ASTM Standard Test Methods and Practices as part of the 2010 FBC and 2010 FRC have been reviewed and found not to affect the method of testing, acceptance criteria, or reporting criteria in such a manner as to result in any change in the performance of the aforementioned product. As such, test results obtained from testing to these standards are valid for demonstrating compliance to the 2010 FBC/FRC. The following table compares the revision levels of the Standards used in testing vs. those required by the 2010 FBC/FRC. It has been determined that Standards used in testing are equivalent to those in the 2010 FBC/FRC in accordance with Product Approval Rule 61G20-3.015(5)(d) Equivalence of Standards. For product evaluation and product approval, the following code adopted testing standard versions will be listed. 1) ASTM G155-05a 2) ASTM D635-06 3) ASTM D638-03 4) ASTM D1929-96(2001)e1 5) ASTM D2843-99(2004)e01 6) ASTM E84-07 Page 5

ITEM NO. 1 2 16 MATERIAL Sheffield / Makrolon SL Eastman / Spectar Plaskolite / Vivak R-Max / TSX-8500 DOW / Thermax Sheathing Solatube TDD Plastics Testing ASTM Standard Standard Revision Level Florida Building Code 2010 FBC 2010 FRC ASTM G155 05a ** 05a n/a ASTM D638 03 ** 03 n/a ASTM D635 06 ** 06 03 ASTM D1929 96(2001)e1 ** 96(2000)e1 96(2001)e1 ASTM D2843 99(2004)e01 ** 99(2004)e01 99 ASTM D635 03 06 03 ASTM D1929 96(2001)e1 96(2000)e1 96(2001)e1 ASTM D2843 99(2004) 99(2004)e01 99 ASTM D635 06 06 03 ASTM D1929 ASTM D1929-12 96(2000)e1 96(2001)e1 ASTM D2843 10 99(2004)e01 99 04 07 07 ASTM E84 04 07 07 ASTM D635 03 06 03 28 Plaskolite / Optix ASTM D1929 96(2001)e1 96(2000)e1 96(2001)e1 ASTM D2843 99(2004) 99(2004)e01 99 **NOA 12-0605.05 confirms testing meets 2010 FBC. Page 6