AMERICAN RECIRCULATING SAND FILTER SYSTEMS

Similar documents
Washtenaw County DESIGN PROCEDURES AND ENGINEERING STANDARDS FOR PRESSURE DISTRIBUTION NETWORKS

PUMP TYPES. Pump Sizing. Dose to Gravity. Pumping to Gravity Distribution. Systems that need a Lift. Distribution Box and Tiered Trenches.

Pressure Distribution Design

Worksheet for pressure distribution system design Long form with instructions and tables Rev. August 2007

EQUAL DISTRIBUTION OF WASTEWATER USING LOW-PRESSURE DISTRIBUTION Larry D. Stephens, P.E. *

Orenco Automatic Distributing Valve Assemblies

Pressure Distribution. Western Canada Onsite Wastewater Management Association

Operation and Maintenance

Recirculating Media Filters OWNER'S MANUAL

Installation and Operation Instruction Manual INSMAN-201. Industrial Multi Media Single Tank

E-Z Treat Installation Guidelines

DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638

WSB clean: Installation Manual

Installation Manual. AdvanTex -AX20-RT Treatment Systems. Residential Applications. An illustrated guide to installing an Orenco AdvanTex

ABCD BFDC BEDA AB CDEFCC

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

Spiral Scraper Clarifier

GB-250. Submittal Specifications Installation Application Specific Details

PRESSURE GAGES AND TEST TAPS

5220 SERIES Z-Cell OWNER'S MANUAL

COURSE # 343 UNIT 4: ADVANTEX WASTEWATER TREATMENT SYSTEM. What you will learn in this lesson

LOWeFLOW -UV Treatment System O& M and Troubleshooting Manual January 2017

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

Series 774 Automatic Skid Package

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

Flood Dosed System Worksheet

OSCAR- LOWeFLOW Treatment System Homeowner s Manual. January 2016

Poly Electric and Non-Electric Drinkers (Models PCPE, PCPI, PCSE, PCSI, PFL-C, PFL-H, PCHI, PCHE, XCPE)

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

To ensure proper installation, digital pictures with contact information to before startup.

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

TNT SERIES WATER CONDITIONERS

Installation - Tank & Aerator

Installation Manual. AdvanTex AX100 Treatment Systems. Commercial Applications

PRESSURE DISTRIBUTION COMPONENT MANUAL FOR PRIVATE ONSITE WASTEWATER TREATMENT SYSTEMS (VERSION 2.0) January 30, 2001

Ruggedized Electric Pump Systems with Integrated Easy Touch Controls

GB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO:

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

Sequencing Batch Reactor. Reference Manual. Only modules bearing the NSF logo and designated PS1-XX are certified to NSF/ANSI Standards 40 and 245

RAS & WAS Pumps (FLYGT Pump)

Poly Electric Drinkers

Lane Reverse Q Pond Outlet Installation and Maintenance Guide

FPS- 80. Manual. Reverso Pumps, Inc. Ph: (954)

Installation & Design Maintenance for ILBP System

Access Riser Fits PRO370 and PRO380 Series

TotalPac 3 Firecyle III Wet pipe Remote controlled system

GREASE INTERCEPTOR REQUIREMENTS Lakeway Municipal Utility District

RAINWATER HARVESTING INSTALLATION GUIDE RH High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application

Sludge Thickening. Wastewater Treatment Review. Gravity Thickening

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

SECTION 1. Fleck Fiberglass Softeners. *Shown with factory SKID & Interconnecting Plumbing

Septic Tanks. Effluent Screen Cleaning. Effluent Screens. Surveying Abbreviations. Installation Keys. Septic Tanks, Holding Tanks & Pump Tanks

SAND FILTERS. Models: ECSF500, ECSF650, ECSF700, & ECSF800

Turbine STEP System SIMPLEX OR DUPLEX

OWS OPERATIONS & MAINTENANCE

ARIES THINWALL DRIPLINE

Multilift M, MD, MDV, and MD1 ranges

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Sequencing Batch Reactor. Maintenance Manual. Only modules bearing the NSF logo and designated PS1-XX are certified to NSF/ANSI Standards 40 and 245

Installation, Operation & Maintenance Manual. TotlSep (TS) Series. FRP Oil/Water Separator

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

ONSITE WASTEWATER TREATMENT SYSTEM Property Transfer Certification Instructions and Inspection Report

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Automatic Self-Cleaning Strainer/Filter Systems

DELPHIN cube. Reliable process Strong tanks Clever modules. Compact biological wastewater treatment plants with fixed-bed technology

SUBMERSIBLE SUMP PUMPS

Multilayer Energy Dissipating Inlet Column in Center-Feed Clarifiers 1

Automatic Self-Cleaning Strainer/Filter Systems

Installation Manual. AdvanTex AX-RT Treatment Systems. Residential Applications

3. The working pressure shall be 145 psi and tested to 230 psi.

AUTOMATIC CONTROL VALVES BY RAPHAEL

A u t o matic Backw ater V alve

LOW OPERATING COST LOW START-UP COST. Media TM has its own built-in. the initial savings over new mechanical

MICROPROCESSOR CONTROL WATER SUPPLY SYSTEM (MPR-01AW)

Aqua Green Utility Inc.

Elite Skimmer Installation Manual. Manufacturers of Quality Pond Equipment & Supplies Item #PBESIM

SUBMERSIBLE SUMP PUMPS

Fleck Top Mount Section 1 Fiberglass Softeners

Flygt TOP 65, 100 and 150. Turnkey pump stations

THS SERIES FILTER OWNER S/OPERATOR S MANUAL TANKS ONLY

OVERVIEW OPERATION. 2 Stormceptor EF Technical Manual

As diesel fuel ages it degrades in 2 ways: particulate formation, and biological growth.

Inst all a ti o n and Oper a tin g Instru c ti o n s

OPERATION & MAINTENANCE for Lamella plate separators OPERATION & MAINTENANCE QUICK GUIDE For models HB50 / HB20 / HB10

Duplex Commercial Pressurizer -DCP

Cleaning Systems Inc. 2 P Rev:03

W4100, W4200 & W4300 Electric Pump

Controller Specification Sheet

Overfill Prevention Valve

3 Spin Klin Battery Operation and Maintenance Manual

CTB3365x Introduction to Water Treatment

Iron Gate Feed Pump Manual

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Weld tabs are standard on all media tanks and screen filter housings.

APPENDIX G PH NEUTRALIZATION SYSTEM TECHNICAL MEMORANDUM

HYDROCARBON SEPARATORS

Transcription:

American Manufacturing Company, Inc. P.O. Box 549, Manassas, VA 20108 1-800-345-3132 AMERICAN RECIRCULATING SAND FILTER SYSTEMS ENGINEERING DESIGN GUIDELINES FOR COMMUNITY AND COMMERCIAL SIZED TREATMENT SYSTEMS S:\10 Engineering\Drip Design Com\RSFguidelines.doc

AMERICAN RECIRCULATING SAND FILTER SYSTEMS ENGINEERING & DESIGN GUIDELINES Table of Contents Section Description Page No I Overview 3 II Basic Components 3 III Sequence of Operation 4 IV Design Parameters 5 V Selecting a typical RSF Configuration 7 VI Standard RSF Configurations 8 AMERICAN MANUFACTURING COMPANY, INC. 5517 WELLINGTON ROAD, GAINESVILLE, VA 20155 1-800-345-3132 American Manufacturing Company, Inc., 2006-2 - www.americanonsite.com

AMC - Recirculating Sand Filter (RSF) GENERAL OVERVIEW & SEQUENCE OF OPERATION Overview of the AMERICAN MFG. COMPANY RSF SYSTEM The AMERICAN RSF utilizes age-old technology and EPA recirculating sand filter standards to provide secondary treatment to primary treated effluent. The primary treated effluent is either pumped or flows by gravity to a Recirculation/Pump tank. Tank is sized for 0.5 to 1.5 days peak design flow. Effluent is pumped to the sand filter on a timed basis via duplex alternating pump system. Pumps are effluent rated turbine pumps situated inside our patented Cool Guide (laminar flow collar). Recirculation rates, pump run times and pump rest times are adjustable. The effluent is distributed through hydraulically activated sequencing valves, which direct effluent to a manifold and onto a series of evenly spaced parallel PVC laterals with pre drilled orifices. A series of under drains collects the treated effluent. The American RSF recirculation technique allows for various recirculation rates including a 100% recirculation option during periods of low flow. Basic Components: Recirculation Tank: Total recirculation tankage shall be sized to equal a volume of a minimum of 0.5-1.5 days raw wastewater flow. For larger projects several smaller tanks may be used to feed sections (zones) of the RSF. Sand Filter Zone: A zone is a section of the RSF that has it s own duplex pump system, manifolds, laterals and sequencing valve. The zone will be timed dosed independently of other zones. Each zone will have several manifolds that will automatically be dosed on a rotational basis via a hydraulic sequencing valve. The number of zones required and the zone size will vary depending on GPD and the recirculation rate with many standard options available. RSF s with multiple zones typically have equal sized zones. Pumps: Each RSF zone shall have a duplex alternating pump system. Pumps are effluent rated submersible turbines each housed in a prefabricated patented laminar flow collar (LFC). Pumps shall have individual breakers and Hand-Off-Auto (H-O-A) switches. Cycle counters and ETM s are optional Force Main: The force main from each duplex pump system shall be typical 2.0 dia. SCH40 PVC pipe feeding the sequencing valve. The force mains from each pump shall each have a check valve, disconnect (SCH80 PVC) and a gate valve prior to teeing together to form a single feed line. Force main material and size may change per the engineer s specifications. Sequencing Valve: The hydraulically operated sequencing valve shall automatically rotate one outlet port every dose. Each outlet port feeds a manifold. The sequencing valve shall be located in a 30 dia. PVC riser. The valve shall be positioned to drain after each dose. Each valve shall have 3, 4 or 5 outlet ports. American Manufacturing Company, Inc., 2006-3 - www.americanonsite.com

Manifold Supplies: Typically 1.5 dia. SCH40 PVC pipe. Each manifold supply shall originate from an outlet port on the sequencing valve and feed one manifold. Manifolds: Manifolds are typically 1.25 SCH40. Each manifold shall evenly distribute effluent to 3, 4 or 5 distribution laterals. Manifolds within a zone are dosed individually. Manifolds are dosed when the rest timer has timed out and the there is enough effluent in the recirculation tank. After a manifold is dosed the next manifold must wait for the pump rest timer to time out again prior to being dosed. Laterals: Distribution laterals are typically 1.0 dia. Sch. 40 PVC with 1/8 dia. orifices spaced 2.0 on center. Lateral spacing is typically 2.0 on center. Lateral length varies but is standard 48. Under Drains: Typical 4 slotted class 125 PVC perforated under drainpipe. Slope is 0-0.1 %. Optional Motorized BRV: This optional electric valve provides for 100% recirculation to continually polish the effluent during periods of low flow. If the Off level float switch is the only float activated the Motorized BRV will automatically turn to divert all effluent collected from the under drains back to the recirculation tank. When the tank level returns to normal conditions the valve will automatically turn to divert water to the distribution box. The inlet port and both outlet ports are 4.0 SCH40 female slip connection. The valve operates on 115 volt and is housed in a 24 dia. PVC riser. Optional heater is available. Distribution Box: Collected effluent shall flow by gravity to the distribution box (ratio box). The d-box may be a prefabricated high-density polyethylene with one inlet port and typical 4 or 5 outlet ports depending on the desired recirculation ratio. Flow rates on certain projects may necessitate the need for a prefab concrete or cast in place d- box. The d-box shall evenly distribute the effluent through several ports with a specific number of ports returning to the recirculation tank and the remaining port to final discharge. SEQUENCE OF OPERATION The AMERICAN RECIRCULATING SAND FILTER is operated via a "state of the art" controller, which is activated by level sensing devices (standard mechanical differential float switch) located in a recirculation tank downstream of the primary settling process. Each controller manages one or more automatic alternating duplex pump systems. When activated by the rising level of effluent in the dosing tank, the controller will enable the dispersal cycle, and as dictated by the time clock, pump the effluent through a force main feeding a hydraulically activated sequencing valves. The sequencing valve will distribute effluent through one outlet port and into a single manifold feeding several parallel distribution laterals. The sand filter pump control panel is equipped with four float switches to control the timed doses to be discharged. The four float switches, "Redundant Off", "Standard Dose Enable", Peak Dose Enable", and "High Level" function as follows: w Redundant Off - The water level must be high enough to overcome the "Redundant Off" (first & bottom) float in order for the pump to be permitted to run. American Manufacturing Company, Inc., 2006-4 - www.americanonsite.com

w w w Standard Dose Enable - When the water level rises high enough to overcome the "Standard Dose Enable" (second) float and the time clock has timed out the preset time delay (rest between dosing cycles for two zone designs) the pump will activate and the lead zone is dosed. The pump will continue to run for the length of time as adjusted on the pump run timer and then shut off. The pump will remain off until the internal time clock again times out the preset time delay after which the pump will activate (as long as the "Standard Dose Enable" float is still up) and will run until the pump run timer finishes timing out. This process will repeat until the water level drops below the "Standard Dose Enable" float and the pump run timer has timed out. Peak Dose Enable - The control system will be equipped with a "Peak Dose Enable" circuit to manage peak flows and excess water use. If the rising water level activates the "Peak Dose Enable" (third) float, the "Pump - Off - Pump & Alarm" switch is set to "Pump", and the preset time delay has been exceeded ("Peak Dose Enable" rest between cycles), the lead zone will be dosed. When the Peak Dose Enable circuit has been deactivated the normal pumping cycle will resume. If the rising water level activates the "Peak Dose Enable" (third) float, the "Pump - Off - Pump & Alarm" switch is set to "Pump & Alarm", and the preset time delay has been exceed ("Peak Dose Enable" rest between cycles), the lead zone will be dosed and the "Peak Dose Enable" alarm will be activated. The audio portion of the alarm may be silenced by pressing the Test-Normal-Silence switch to the silence position. When the "Peak Dose Enable" float has returned to the down position the alarm will be deactivated and the normal pumping cycle will resume. High Level - If the water level rises enough to overcome the "High Level" (fourth) float, the audiovisual alarm will activate. The audio portion of the alarm may be silenced by pressing the Test-Normal-Silence switch (located on the outside of the control panel) to the silence position. The alarm circuit will latch until manually reset after the "High Level" float returns to its normal (down) position. The alarm circuit is manually reset by switching the High Level Reset/Off-Normal switch (located inside the control panel on the inner door) to the Reset position then back to normal. DESIGN PARAMETERS: Design parameters are based on EPA recommendations. Standard AutoCAD details are provided by American Manufacturing for use by the design engineer. MEDIA: Recommended effective size of the media ranges from 1.0-3.0 mm. Coarse material is preferred. Uniformity coefficient should be 3.5 to 4.0 (3.5 preferred) (Teske,1978; Hines and Favreau, 1975). The media must be carefully placed in the filter to prevent stratification of the material. It should be homogenous throughout its depth. To prevent the media from sifting into the gravel below, several inches of 1/4 to 3/8 pea gravel should be placed on top of the 1/2 to 3/4 size bottom layer of gravel before the media is added. American Manufacturing Company, Inc., 2006-5 - www.americanonsite.com

HYDRAULIC LOADING RATE: Hydraulic loading rates are dependent on the media size. They should range from 3.0-5.0 gpd/sq.ft. based on forward flow. A recirculation rate of 3:1 to 5:1 (recycle:forward flow) is typically used (Hines & Favreau, 1975). DOSING & DISTRIBUTION: Each zone will be dosed 48-120 times per day with ideal volumes equaling 1-2 gal/orifice/dose. Flow rate (gpm) per lateral is determined by lateral length, orifice size, orifice spacing and head pressure. All run and rest times are easily adjustable. Orifice shields are required to prevent clogging of the orifice from the outside. Distribution shall be primarily through low-pressure pipe using standard low-pressure distribution design procedures. A hydraulically activated sequencing valve automatically rotates flow through several manifolds. Each sequencing valve is supplied by a duplex alternating submersible pump system controlled by automatic time and level settings. FILTER ENCLOSURE: Most large-scale commercial filters are constructed in ground. A typical 30-mil PVC liner is placed over a shallow (2.0 ) sand-leveling layer. The liner extends up and over the four sidewalls. Sidewalls are supported by 1/2 untreated plywood. All pipes penetrating the liner shall be equipped with an appropriately sized liner boot. Smaller filters are usually made of either prefabricated or poured in-place concrete or masonry walls set on a poured slab. Any portion of exposed filter walls should be well insulated to protect from freezing. Covers may be necessary in severe climates. Buried sand filters are covered with a light filter fabric and several inches (typical 6 ) of soil with established vegetation (i.e. grass). A sandy loam is recommended. OPERATION & MAINTENANCE: Routine O & M is required for all recirculating sand filters. Influent and effluent sampling and analysis is typically required on a periodic basis. Verification of flow rates, run times, rest times, pump & controls operation is standard. Flushing of laterals and measuring of orifice head pressure should be done annually. Normal sludge measurement procedures should be used to determine if a pump out is required. American Manufacturing Company, Inc., 2006-6 - www.americanonsite.com

SELECTING A TYPICAL RSF CONFIGURATION: Area Required: GPD / Recirculation Rate (3.0-5.0 gpd/sq.ft.) = SF Area Required (sq. ft.) Sand Filter Length: Typical Sand Filter Length = 50 Sand Filter Width: Area Required (sq.ft.) / 50 length Determine Number of Laterals Required: Typical lateral spacing: 2.0 Note: Sand filter length is 50 but laterals have 1 ft separation from both ends creating an effective lateral length of 48. Width (ft.) / Lateral Spacing (typ. 2 ) = Number of 48 laterals required Determine which standard configuration to use: Refer to selection chart in Table 1 EXAMPLE: 20,000 gpd w/ a 5.0 gpd/sq.ft. loading rate Area Required: 20,000 GPD / 5.0 gpd/sq.ft. = 4000 sq. ft. required Sand Filter Length: Typical Sand Filter Length = 50 Sand Filter Width: Area Required (sq.ft.) / 50 length 4000 sq.ft. / 50 = 80 width Determine Number of Laterals Required: Typical lateral spacing: 2.0 Width (ft.) / Lateral Spacing (typ. 2 ) = Number of 48 laterals required 80 ft / 2.0 ft. = 40 laterals of 48 length required. Determine which standard configuration to use: Refer to selection chart in Table #1 Options for 40 laterals from Table #1 are SF 245 or SF 254 American Manufacturing Company, Inc., 2006-7 - www.americanonsite.com

Table #1 STANDARD RSF CONFIGURATIONS No. of SF Configuration Example SF 245 Laterals Options SF Sand Filter 8 SF 124 9 SF 133 2 Sequencing Valves 12 SF 134, SF 143 4 Manifolds per SEQ Valve 15 SF 135, SF 153 5 Laterals per Manifold 16 SF 144 18 SF 233 All lateral lengths are 48'. 20 SF 145, SF 154 24 SF 234, SF 243 25 SF 155 27 SF 333 30 SF 235, SF 253 32 SF 244 36 SF 334, SF 343, SF 433 40 SF 245, SF 254 45 SF 335, SF 353 48 SF 434, SF 443, SF 344 50 SF 255 60 SF435, SF 345, SF 453, SF 354 64 SF 444 75 SF 355 80 SF 445, SF 454 100 SF 455 www.americanonsite.com American Manufacturing Company, Inc., 2006-8 - www.americanonsite.com