Thirteen (13) UL listed fluorescent fixtures per booth will supply illumination.

Similar documents
Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

Open Front Booths. UL & ETL listed control panel. Air solenoid valve. 5/16" bolts with serrated lock nut. Industry-leading light levels

Engineered Products. Contact an Engineered Products team member today for your special projects.

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

INDUSTRIAL PRODUCT CATALOG

Global Finishing Solutions Table of Contents

Truck and Large Equipment

Global Finishing Solutions Table of Contents

Open Face Industrial Booths

SECTION AXIAL HVAC FANS

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

Model ND-2 Specification

Think Dustless..com MAGNUM 5000

Direct Gas-Fired Heating

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

SECTION CENTRIFUGAL HVAC FANS

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

Filtered Kitchen Supply Packaged Ventilator

SINGLE DUCT TERMINAL UNITS

Inline Fans [ 14 ] * UL is optional and must be specified.

TORIN by: AIRDEX Index Page No.

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

LOW PRESSURE MIXED FLOW FANS

forward curved inline duct blowers

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

TUBULAR CENTRIFUGAL INLINE FANS

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

HORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

MODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

Air Moving Solutions. low pressure mixed flow fans. QCLB QCLBR (Restaurant) QCLBSH (Smoke & Heat)

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

Global Finishing Solutions. Powder Booths. > Non-Recovery. > Cartridge System (Powder Collection) > High Production Systems.

SECTION DUCTWORK ACCESSORIES

HOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

Powder Booths. Non-Recovery Booths Cartridge Style Booths High Production Booths GLOBAL FINISHING SOLUTIONS.

Square Inline Fans with Multi-Directional Discharge

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

Custom Metal Fabrication - HVAC Air Duct and Fittings

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

KVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood

Industry best 5 year fan housing warranty, 1 year motor warranty

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

SECTION AIR TERMINAL UNITS

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

Tube Axial Inline Fans

Air Handling Unit Fan Selection Guide

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan MIXED FLOW FANS QSL QSLR QSLSH CATALOG 1060 MARCH 2017

Defining Innovation. mixed flow fans. TYPE QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat) QFE (Fume Hood Exhaust)

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

Direct Gas-Fired Make-up Air Heaters

TGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

TYPICAL SPECIFICATION: Critical Process Roof Top Unit 7/14/15

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

ceiling & inline/cabinet ventilators

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

Twin City Fan & Blower

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES

Requires Ductwork and Blower

Tubular Centrifugal Fans

Twin City Fan & Blower

NJK Precision Product NJK-02 Sensor Installation Guide

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

Transcription:

Quoted as per your request: two (2) Non-Pressurized, Drive-Thru, Full Down Draft, Paint Booth model: TDD-16-16-20-DT with interior working dimensions of 16-0 wide X 16-0 tall X 20-0 long. Overall dimensions will be 16-6 wide X 16-2 tall X 20-4 long. The two booths will be connected by a custom 16-0 wide x 16-0 high x 10-0 long 18 gage galvanized sheet metal vestibule with two (2) man doors and will be designed to handle the part load required. This is quoted per provided drawing. Two (2) 36, 10 HP, three phases, ODP, 208/230/460V, vane-axial fans each operating at 16,000 SCFM @ 2 static pressure will provide exhaust. Total air exhaust is 32,000 SCFM. Thirteen (13) UL listed fluorescent fixtures per booth will supply illumination. Two (2) set of product entry/exit bi-fold doors will provide a clear opening of 14 wide X 15-0 tall. Product door header will be notched to accommodate 6 I-Beam conveyor runs through-out. Four (4) personnel doors 30 wide X 84 tall with observation windows 14 ½ wide X 48 tall will provide egress. There will be one man-door in each booth and two man doors in connecting vestibule. An ETL listed EH-2734K heat only vertical, indoor heated air replacement unit will provide 32,000 SCFM of tempered replacement air to the shop. The AMU is capable of providing a 100 F temperature rise from its 3,000,000 BTU burner. The AMU controls will also provide controls for the exhaust fans (VFDs) and booth lighting. The AMU is designed for dump into room only thru a custom designed discharge plenum especially designed for this application and will be suspended from the ceiling per the drawing provided approximately 18 off the floor between conveyor rails. Exhaust, Intake, and Discharge duct (if quoted) is shown for estimation purposes only and assumes a straight run with no offsets. Actual ductwork requirements will be dictated by field conditions including but not limited to verified roof height, roof pitch, obstructions and local code restrictions. Based on 40 Pitched Roof with a 3/12 pitch. This roof height and pitch is subject to verification.

Qty. Description: 2 TDD-16-16-20-DT Non-Pressurized Solid Back Full Downdraft Booth Includes vestibule for connecting booths 1 EH-2734K Vertical Indoor AMU Heat Only w/controls for Exhaust Fans & Booth Lighting. 32,000 SCFM Dump into room. 1 Discharge Duct: 8 straight, (1) transition 1 Custom Discharge Plenum 7 W x 36 D x 17 L 1 Lot of AMU Intake Ductwork 46 includes elbows and transitions. Includes AMU Hood 2 MC36 Motor Cover 2 SPD36 Spiral Pipe Duct w/ Cleanout Door and connection ring (10 Sections) 10 SP36 Spiral Pipe Duct w/ connection ring (10 Section) 2 ARV36 Automatic Roof Ventilator 2 PRF36 Pitched Roof Flashing Total

Two (2) Non-Pressurized Drive- Thru Downdraft Paint Booth Model: TDD-16-16-20- DT Booth with Connecting Vestibule Dimensions: Interior Exterior Width: 16-0 16-6 Height: 16-0 16-2 Depth: 20-0 60-4 Scope: Air flows in through the Filtered roof of the booth, flows downward through the work area, then down into an exhaust pit located in the floor. Filtered exhaust air is drawn through the pit and discharged to the atmosphere through the exhaust stacks. This booth is provided complete, with all necessary hardware to meet the applicable national requirements established by OSHA and the NFPA for paint booth construction. PIT WORK BY OTHERS. WE WILL PROVIDE PIT DRAWING WITHIN ONE WEEK OF THE ORDER AND WILL UTILIZE MAN-WEIGHT GRATING ONLY. Construction Features: Panels: Panels are fabricated from 18-gauge prime quality galvanized steel precision punched on 6 centers for maximum rigidity. Panels are fastened together with 5/16 bolts and are to be sealed with the provided caulk following assembly. Columns and Beams: Fabricated from structural steel members, precision punched on 6 centers to match corresponding panels. (W6X9 & Web Joist Support Steel for support of 1,500 lb. parts) Illumination: Lighting is provided by 48 long, 4-tube, 32 watt, T-8, fluorescent type fixtures. Each is mounted behind tempered safety glass that is sealed from the interior of the spray booth with a continuous gasket placed around the perimeter of the light window s opening. All fixtures are UL listed and approved for their intended use and placement. Fixtures are supplied with dual ballasts to accept either 120V or 277V power. Each booth will have Thirteen (13) LIGHTS. There 11 open style light fixtures and 2 Class I Div. II Light fixtures.

Filtration: Intake air filters: Rated by UL as Class 2 and are EPA registered as environmentally safe. Filters are self-supporting in an internal frame sized 20 x 20 x 1. One (1) set of filters will be supplied with this unit. Exhaust air filters are a fiberglass paint arrestor pad made specifically for the collection of paint overspray. These filters are UL rated as Class 2. A filter holding grid is provided for each filter cell. This unit is provided with one (1) set of filters. Two (2) manometers will be provided with the unit to monitor the filter resistance and thereby the filters life and efficiency Exhaust Fan Units: A Vane-axial type duct fan specifically designed and constructed for use in paint spray booths and similar applications is provided for exhaust. A precision balanced, fabricated, aluminum non-sparking fan blade moves the air through the fan. Bearings are mounted in rubber isolators for smooth operation. The motor, drive, and bearings are isolated from the exhaust air stream. The bearings are sized with a minimum average life, per AFBMA, in excess of 200,000 hours when operating at the maximum RPM of the fan size. Two (2) 32 vane-axial fans with 10 HP @ motors operating at 16,000 SCFM of exhaust is supplied. Total air exhausted is 32,000 SCFM Air Replacement Units: This unit will have ONE (1) EH-2734K heat only direct fired, natural gas heaters; designed, assembled, wired and factory tested, providing a minimum of 32,000 SCFM of clean tempered air @ 3/4 ESP, and having the ability of providing a minimum 100 degree temperature rise from its 8,171 million BTU burners. Total air supplied is 32,000 SCFM. Controls and gas train to be AGA designed. This unit is equipped with an casing for its vertical configuration and discharge. A volume control damper is provided to vary the air volume. The AMU s control panel will be equipped with the starters for the exhaust fan. Mounting stands and the inlet screen and filters are provided for each AMU.

Product Doors: Two (2) set of product entry/exit bi-fold doors are fabricated with tube steel frames hung on structural channel jambs. These doors are skinned with an 18-gauge galvanized steel sheet, sealed to the frame with rubber sealant and screwed in place. These doors are provided with an open cell foam rubber weather stripping seal about the perimeter and a neoprene rubber sweep seal at the threshold. The mounting hardware provided includes a FM approved panic type safety latch, one (1) door limit switch and four (6) door pulls. These shall be bi-fold doors having a clear opening of approximately 14 wide by 15-4 tall. Door header will be equipped with two conveyor cut-outs for 6 I-Beam conveyor. Personnel Doors: Four (4) personnel doors with observation windows 14 ½ wide X 48 tall are provided as 18-gauge galvanized steel units sized at 30 x 84 and are provided prehung in a heavy gauge steel frame ready for mounting to the spray booth. The mounting hardware includes a FM approved panic type safety latch, one (1) limit switch, striker plate and two (2) door pulls. Mixing & Storage Room: Model ATR-PMR1015 Inside Dimensions are 15 Long x 10 Wide x 8 High Galvanized 18-gage nut and bolt Single Wall panel construction. Exhaust System: (1) 12 Tube Axial Fan. Lighting System (2) Ceiling mounted open type mounted behind clear glass, 4-48" T- 8 color corrective tubes and electronic ballast. Man Access Door: (1) Personnel Access Door with observation window. Exhaust Duct Package: (1) 12 Diameter Exhaust Duct package for a 15 high roof, Damper Cap (excludes offsets). Assembly Hardware: Included with All Mixing & Storage Rooms are Intake Filters, Fan, Motor, Drives, Sheet Metal Screws, Nuts, Bolts, Etc., and Blueprints.

(2) PAINT BOOTHS W/BLDG. AMU (1) PMR-1015 Paint Kitchen w/ductwork MONORAI L SYSTEM: Includes: 1,540 of 6 Standard I-beam (For Twin rails and Supports) 100 (1) Ton Trolley s Added Steel etc, to mount AMU to the conveyor supports: MECHANICAL INSTALLATION The above includes building the supports and conveyor ELECTRICAL INSTALLATION Customer is responsible for ( Gas & Compressed Air Plumbing, and Fire Suppression) Please Call For Print 877-263-8733