when it comes to quality! BMR GmbH 1

Similar documents
when it comes to quality! BMR GmbH 1

Cooling Unit KG-T 500

EPS/ELA-Series User Manual EPS/ELA 250W

Active Controlled Cooling System

Ag Features. Multi-Stage Charging. Solar Panel or DC Input. Maximum Power Point Tracking (MPPT) Very Low Power Consumption

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

Section 3 Technical Information

4.2 Component Identification

WEG Cooler. Table of Contents. Introduction and General Description. 3. Operational Specifications.. 4. Dimensional Specifications.

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

M u l t i P o w e r. CM MultiPower. Installation and Operating Manual

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Positive displacement batch controller

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

TABLE OF CONTENTS. Understanding the Troubleshooting Instructions...2 Signal Light...2 Harness Connections...2 Inspection...2

Phoenix Inverter

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

HIGH POWER SOLENOID DRIVER 1

Nexa 1200 Fuel Cell System

VP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

The Intelligent Valve Sensor. DeviceNet

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

Digital Pressure Regulator Sentronic PLUS Series 614

Pressure chlorine changeover unit C 7520

Electromagnetic Flow Monitor magphant

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

SAVER DSP SERIES. 3-10kVA USER MANUAL

8. Remote Control Panel P4 Control

CX-SERIES ADVANCED BATTERY CHARGER

PV Charge Controller SBC-7108 / 7112 / 7120

TABLE OF CONTENTS. Understanding the Troubleshooting Instructions...2 Signal Light...2 Harness Connections...2 Inspection...2

Generator Sets Controller 210. Operation Manual. Ver1.0

LF Series Spring Return Direct Coupled Actuator

Pressure Transmitters

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

Pure sine wave charger inverter Product Manual

Brake Chopper BC BC 4.1. Instruction and Operation Manual

StartSentry. UCS-80Kj and UCS-80KjC. Ultra Capacitor. Table of Contents

USER MANUAL EVAPORATIVE AIR COOLER OUR COMPLETE LINE

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Updated: October 2012

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Installation, Operation and Maintenance Manual

SR8-Plus 2 Phase Step Motor Drive

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Troubleshooting. CryoSmart 1 - CryoSmart 20

Phone: Fax: Web: -

UPS24 application instruction

DIESEL Engine Fire Pump Controllers Features

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

TRIPS AND FAULT FINDING

PURE SINE WAVE DC TO AC POWER INVERTER

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Installation and Operating Instructions. Solar System Controller ISC3020

September 2008 TEC, INTELLIGENT MONITORING SYSTEM

Operating Instructions for Plastic Flow Meter. Model: KSK

R-100 Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

Buchholz Relay MBP Gas and Oil Actuated Relay

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

Positive displacement flowmeter for continuous flow measurement

Installation Instructions

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

Subject Underhood G System Error Codes and Symptoms System or Parts affected

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

Digital Energy LP 11 Uninterruptible Power Supply kva

User Manual WT Combi-S Pure Sinus Wave Inverter

DEEP SEA ELECTRONICS PLC

HYDRUS ULTRASONIC METER

PV Charge Controller SBC-6108 / 6112 / 6120 / 6130

Number 1 in efficiency

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Number 1 in efficiency

STONESTAR AUSTRALIA PTY LTD

AA4006 Speed Sensitive Trip Unit. User Manual

Manual. Lynx Ion 24V/180Ah Lithium Ion Batteries

Transcription:

when it comes to quality! BMR GmbH 1

2 Cooling unit KG-T 500

Issue January 2017 1 General description 2 2 Savety instructions 3 3 Technical Data 3 4 Connector pin list 4 4.1 Connector electric 4 4.2 Connector cooling fluid 4 5 Block diagram 5 6 Display 6 7 Initial operation 8 8 Description of operation 9 9 Flow chart 10 10 Error messages 11 11 Installation 12 12 Service and care 12 13 Engineering detail 13 14 Shipment 14 15 Accessories 14 12 Other products of BMR GmbH 15 13 Quality commitment 16 when it comes to quality! BMR GmbH 1

1. General description The cooling unit KG-T 500 is controlled by an internal microprocessor. It has been designed to run high speed spindles like in cool ambience conditions. You are able to use it nearly for all types of spindles and cooling blocks. The maximum range of spindle power is 2000W. The KG-T 500 has an integrated and intelligent cooling fluid control. It depends on the temperature of the cooling fluid. According to requirements the fan power will be set to get more or less cooling power. This system runs always in an automatic mode and the users do not need any setting before starting or during operating. On the front panel you have a LCD-Display. It shows all modes of run and errors. Display shows: Operating hours and Software Version Temperature of return T R [ C] and air temperature T A [ C] Fan power [30-100%] Cooling fluid flow * [l/min] Error messages An internal relay shows the status of ready to operate of the KG-T500. This relay has the opportunity to be used as a normally open or as a normally close contact. By power on or in standby the relay will be energized. In an error case it will be set off. The tank of the cooling fluid has a volumetric capacity about 1,5 liters. Use distillated water with additives as cooling fluid. The current fluid level is shown at the front panel, look at marks for maximum and minimum range. The KG-T 500 has an integrated follow-up timer. When a STOP signal was send to the cooling unit, the cooling process will still keep going on for a defined time. Therefore the endurance of your spindle will be extended and spindle services will be coming at a later date. So you are able to reduce costs. 2 Cooling unit KG-T 500

2. Safety instructions In case of current overload or short circuit you have to be ensured, that the KG-T 500 will be disconnected to power supply. The cooling unit should never operate in an unsupervised run. Be careful by filling the tank of the KG-T 500. Wrong bearing fluid should be immediately taken off by a sponge or a try cloths. Before filling the KG-T 500 with cool fluid, please check the power supply. It should be separated from the cooler und control the de-energized mode of the system. Before starting the KG-T 500 please check all screw connection, cables, pipes and gaskets. Use only specified pipes like described in capture 3. 3. Technical Data TECHNICAL DATA Nominal Voltage Start input voltage Power input Cooling power Relais details Fuses LCD-Display Dimension (WxHxD mm) Pipe aperture Cool fluid Tank volume Flow rate Pressure 100-250 V AC / f=50hz max. 24V DC 80W max. 500W by ambient temperature <23 C max. 30W (30V DC / 1A) 2A 16x2 Matrix 438 x 131,5 x 308 Ø8 mm (outside diameter) Distilled water additives to protection against corrosion) 1,5 l max. 3,6 l/min. 1,4 bar (with when it comes to quality! BMR GmbH 3

4. Connector pin list 4.1 Connector electric Pinning of Control-Connector X1 (female) Pin 1: Relay normally open (NO) Pin 5: Input (start signal) Pin 2: Relay collective contact Pin 6: Output 24V DC Pin 3: Relay normally close (NC) Pin 7: disconnected Pin 4: GND (0V) Status of KG-T500: Relay contact on connector X1 female connector X1 KG-T 500 Status KG-T500 Power ON Standby / KG-T500 in work Error / Power OFF Status of relay energized not energized Normally open (Pin1-2) Relay contact close Relay contact open Normally close (Pin3-2) Relay contact Open Relay contact Close Connector X1 digital signals: X1/4: GND (internal 0V) X1/5: Input start signal U Input = 24 V DC KG-T 500 = ON U Input = 0 V DC KG-T 500 = OFF X1/6: Output power supply U out = 24 V DC (I max = 50mA) Mains voltage: Input voltage: 100 250 V AC 4.2 Connector cooling fluid Connector A1 Connector A2 Connector A3 Flow forward (fluid to spindle) Flow return (fluid from spindle) Fill port Info: The scope of delivery include 2 plug nipples (Typ NW5/DN5) for a house with an inside diameter of 6mm. 4 Cooling unit KG-T 500

5. Block diagram when it comes to quality! BMR GmbH 5

6. Display On the front panel you have a 16x2 LCD display which shows all modes of the KG-T 500. All these messages are possible: Startup: BMR GmbH KG-T500 Vers:1.3 Software Version Typ of cooler Ready mode (waiting for a start signal): BMR GmbH KG-T500 IS READY Operating time: OPERATING-HOURS: 124 h 23 min Minutes (0 59 min) Hours (max. 60.000 h) 6 Cooling unit KG-T 500

Normal mode (RUN): Tr: 23C *1,2 L/min Ta: 21C FAN: 80% Flow Fanpower (30 100%) Temperatures: Return Tr and Air Ta Error message: FAN ERROR! FAN STOP Check FAN Fan failed Error message: FLOW ERROR! NO FLOW Check FLOW Flow is less than 0,5l/min Error message: Over temperature ERROR! TEMP>50C!!! STOP!!! Fluid temperature to high Nachlaufsteuerung: STOP in 5 Min. Temp. RL: 26C Follow-up timer No start signal, autocontrol activ when it comes to quality! BMR GmbH 7

7. Initial operation At first, check the KG-T 500 for external damages of transport. Connect the fluid pipes of the spindle with the KG-T 500 : Fluid from the KG-T 500 to the spindle set on connector 1 (Flow forward) Fluid from the spindle to KG-T 500 set on connector 2 (Flow return). DANGER: Before filling the tank with cool fluid, please check the power supply. It should be separated from the cooler unit and control the de-energized status of the system. Now open the tank and fill it to its maximum level. Be careful by doing this. Now use the BMR power cable to set the main supply of 100... 250V AC to the system. Start the KG-T 500 with the main power bottom at the front panel. When you read KG 500 IS READY on the display you are able to go on with the initial operation. Next step you need an external start signal of 24V DC on connector block X1/5. You have the possibility to use the internal start voltage on pin X1/6. Therefore you have to make a bridge between pin X1/5 and pin X1/6. By the first time of running you have to refill again the tank to its maximum level. How often you have to repeat that, depends on the length of your pipe system. Refill your KG-T 500 so often until you reached a constant fill level and your tank is free from air bubbles. Make a leak test at the end of your first run. 8 Cooling unit KG-T 500

8. Description of operation After power on the KG-T 500 shows the software version on the display. After a few seconds the operating hours appear on the LCD. When you can read KG 500 IS READY the initiation has been finished. The KG-T 500 is ready to start. The status relay will be energized until the system is ready or in a cooling process. In an error case the status relay will be de-energized. You need an external start signal on connector X1/5 to start cooling process. If there is no start signal the KG-T500 will be set into a standby mode. The fan power depends on the temperature measurement and it will be automatically controlled by the mainboard. The minimun fan power is 30%, the maximum range is 100%. The control of the fan power will be set in steps of 10%. To start the KG-T 500 you have to set an external signal of 24V DC von Pin X1/5. The cooling unit starts with a power of 30%. Under a temperture of 26 C the fan control will be set to 30% constantly. By a temperture more than 26 C the fan control will be switched on. By an increasing fluid temperatur the fan power will be forced up, too. When the cooling fluid temperature suddenly increases more than 40 C, the KG-T 500 turns into an QuickCooling mode. In this mode the fan power will be set to its maximum range of 100%. By falling fluid temperatur, the fan power will be reduced to a minimun necessary level. To stop the cooling process you have to remove the start signal on pin X1/5, set to ground (0V). The cooling unit did t stop immediately, an autotracking function will be started. The integrated follow-up timer has 2 different times to load. It depends on the last temperature measurement. Temperature > 30 C Stop in 5 min Temperature <= 30 C Stop in 1 min The remaining time to stop and the current temperature will be shown on the display. When the KG-T 500 operates in autotracking mode it s possible the make a restart anytime. when it comes to quality! BMR GmbH 9

9. Flow chart 10 Cooling unit KG-T 500

10. Error messages When an error appears, it s shown on a blinky display and you can hear an alarm signal. Until an error exists the status relay will de-energized. The relay is connected to X1 pin1-3. You have to analyse the reason for the error and you have to eliminate it quickly. When error has been removed the message on the display will be cleared automatically. If there is no more error the status relay will be energized again. The cooling capacity of the KGT 500 stands during an error message not fully available! The cause of the error should be rectified immediately. Error message on display: ERROR! FAN STOP Check FAN Reason: Relief: Fan breakdown or closed. Send KG-T 500 to BMR Company. Service! ERROR! NO FLOW Check FLOW Reason: Flow of fluid to less ( < 0,5 l/min). Pipes are closed. Less cooling fluid. Relief: Check fluid level at front panel, refill the tank. Check flow forward and return at KG-T 500. ERROR! TEMP>50 C!!! STOP!!! Reason: Relief: Temperature of cooling fluid to high (Tr > 50 C). Stop spindle drive immediately. Check data sheet of the spindle, which temperature range is allowed? Higher temperature range is sometimes possible. when it comes to quality! BMR GmbH 11

11. Installation To assembly the KG-T 500 into a spindle system you need a horizontal under-floor. We allow an addiction to the horizontal of maximum 10. More addiction may be causes failure of fluid run. Leakage fluid can damage the KG-T 500. The aspirating holes of the cooling unit are on the floor panel. When they are closed the cooling power of the KG-T 500 will be decrease and the efficiency factor decreases, too. Keep them always clean and open. The air delivery ports are on the rear side. Please keep a distance of minimum 10 cm to a wall. The coolant hoses should be kept as short as possible. For too long cooling hoses reduce the coolant flow! We also recommend a minimum hose diameter of 6mm. 12. Service and care Before starting the KG-T 500 please check the cooling fluid level at the front panel. We advise you to change the cooling fluid after 4 6 weeks. When you see floating particle inside the tank please change cooling fluid immediately. A lot of floating particle can plug pipes and heat exchanger. Please control all aspirating holes and delivery ports. After 2000 operating hours we recommended to send the KG-T 500 to the BMR company for aftersale service and machine care. 12 Cooling unit KG-T 500

13. Engineering detail MAX KG-T500 BMR GmbH KG-T500 MIN ON OFF Tank (A3) Fluid Level Control Display Power Switch Powercable Fan out Flow forward (A1) Flow return (A2) Connector (X1) D E F G C A B A = 438mm D = 40,0mm G = 131,5mm B = 81,5mm E = 65,5mm F = 90,0mm C = 41,5mm Deepness = 340mm (without any connectors) when it comes to quality! BMR GmbH 13

14. Scope of delivery 1 x Cooling Unit KG-T 500 1 x Plug connector (7 pins female) 2 x Male coupling NW5 / DN5 for coolant hose (6mm inside diameter) 1 x Hooper 1 x 2 liter freezing agent or concentrate for 2l 1 x power cable 15. Accessories 1l freezing agent Male coupling NW5( 6mm diameter) Male coupling NW5( 8mm diameter) Male coupling NW5( 9mm diameter) ONE PRODUCT IS NOT ENOUGH 14 Cooling unit KG-T 500

MORE PRODUCTS OF BMR GMBH Sealing Air Follow-Up Control Nominal voltage: Start input voltage: Power consumption: Relay details: Accu: SFU 0156 Remote-Control 24VDC (+/- 10%) max. 24 VDC 7W 30VDC / 1A; 60VDC /0,3A; 125VDC / 0,5A 12V / 1,5Ah Als Option ist ein Fernsteuer-Adapter zum direkten Anschluss an das I/O Interface an der Stiftleiste SL2 verfügbar. On option a remote controller is available which can directly be connected with the I/O interface at SL2. By this, the required duty speed can be adjusted with a potentiometer and the converter can be started and stopped with a rocker switch. The status of the digital outputs is indicated on LEDs. The solution for monitoring and control of the sealing air of the machine Life time extension for all spindles operated in wet ambient conditions Protection against dripping fluids even at power off by sealing air overshoot time Full control for integration into PLC by I/O Spindle-Illumination-Ring All required voltages are generated within this adapter, so the converter can be controlled and tested very easily. A quick test and setting into action of the converter becomes possible even without external control signals. Spindles Don t you know the problem, that despite of lighting systems, exactly at the point where you need to see something, a shadow appears or there is too less light? High - frequency spindles are essential in today's adaption technology. Each application requires a specific solution. Optionales Zubehör: With the new spindle illumination ring of BMR GmbH this problem belongs to the past!.and many more! OUR QUALITY COMMITMENT when it comes to quality! BMR GmbH 15

100% Made in Germany 100% precision 100% reliability 100% support 100% flexibility Subject to technical alterations. January 2017 16 Cooling unit KG-T 500

when it comes to quality! BMR GmbH 17

18 Cooling unit KG-T 500