(Type J) (Type K) (Type T)

Similar documents
Barnant Company (Type J) (Type K) (Type T)

Thermocouple Thermometer Models

EGT MONITOR AND PROBE KIT BG FUEL SYSTEMS McDonald Road Dahlonega, GA (706) A Edition 03

Thermistor Thermometer MODEL NO

Single-Input Thermocouple. Thermometers Type J, K, T

Instruction Manual. Single-Input Thermistor Thermometer (Model )

Temp-14 Single Input Thermistor Thermometer

OPERATING MANUAL. Cole-Parmer Stir-Pak General-Purpose Laboratory Mixer. Model Number General-Purpose Laboratory Mixer System

OPERATING MANUAL HIGH PERFORMANCE PUMP HEAD. Model Cole Parmer

operating manual DL7 101 DIGITAL THERMOMETER


51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

DT304. Digital Temperature Logger INSTRUCTION MANUAL

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual


OPERATING MANUAL HAZARDOUS-DUTY PUMP DRIVE

Infrared Thermocouple Probe

True RMS Autoranging Multimeter

Autoranging Multimeter

DigiTemp. Digital Thermometer

Operator s Manual TC-253A. Temperature Converter

PUMP SYSTEM OPERATING MANUAL:

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

Defender 3000 Series Base Instruction Manual

Hybex Microsample Incubator

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Autoranging Industrial Multimeter

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Low Amp Probe EETA308A

Budget Series Digital Thermometer. Instruction manual Models 874F/C, 875F/C, 878 and 879

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

OPERATING INSTRUCTION

OPERATING INSTRUCTIONS

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

A419ABG-3C Electronic Temperature Control

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

SLA Battery Capacity Analyzer

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

Megohmmeter Test Probe

1.Safe testing IMPORTANT:

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Valor 2000 Series Instruction Manual

Table of Contents. 1. The Statement Overview Instrument Familiarization Method of use General Specifications...

Table of Contents Title Page No.

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY

TMD90A Dual Input Digital Thermometer

Salt 1 Pocket Salinity Tester Instruction Manual

Lumitester PD-30. Instruction Manual. Table of Contents

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Resistance thermometer with digital indicator Model TR75, battery operation

Thermo Fisher Scientific (U.S. and Canada only) 11 (847) (Outside U.S.) (847) (Local)

Instruction Manual. IT-1 Infrared Thermometer

MODEL PS-4 DIGITAL PORTION SCALE

i3000s/i2000 Flex AC Current Probe

User's Manual. Earth Ground Resistance Tester. Model Introduction

3000 SERIES DRY-BLOCK HEAT SOURCE

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Illustrations. Contents. Burns Connection Head. Models #22, #23 & #24 with Battery Powered LCD Indicator Instruction Manual

Model DS7060 Handrail Scale. User Manual

POCKET-TACH 100 MONARCH INSTRUMENT Rev 1.4. Instruction Manual. Printed in the U.S.A. Monarch Instrument 2001 all rights reserved

OPERATING INSTRUCTIONS

Switching DC Power Supply

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

1/16 DIN Temperature Controller E5CS

Marin Control Digital

Cole-Parmer Pro-Spense

OPERATING INSTRUCTIONS MESURES. Portable sludge level measuring instrument, battery operated MES. MUDLine TGS

KIT CONSISTS OF: FEATURES. S-Digit mini

User Guide. Model Insulation Tester / Megohmmeter. Introduction

ALP/4500 FRONT APPLY SWING ARM. Revision A

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

DIGITAL RCD(ELCB) TESTER

LEM~flex RR3020 AC Current Probe Operating Instructions Mode d emploi Bedienungshandbuch Manuale Operativo Manual de uso

Product Information. Kugelrohr Short-Path Distillation Apparatus. Operation Instructions Z V Apparatus Z V Apparatus

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Thermo-Anenometer Model Owner s Manual

IAQ-CALC TM Indoor Air Quality Meter

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

innovations in battery charging

innovations in battery charging

fax

323/324/325 Clamp Meter

Transcription:

Thermocouple Thermometer Models 91100-00 (Type J) 91100-10 (Type K) 91100-20 (Type T) Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com e-mail: techinfo@coleparmer.com A1299-0628 Edition 06

ACCESSORY THERMOCOUPLE PROBES Cole-Parmer offers a wide variety of thermocouple probes, wire, connectors, extension cables, switch boxes, accessories, and calibration services. The popular probes listed below have a nylon handle, a 5-ft coiled cord and a 316 SS sheath. General-purpose probes, 5 in long x 0.156 in dia with 0.093 in dia tip. 3 second time constant. Type J 08517-55 Type K 08516-55 Type T 08500-55 Penetration probes, 4 in long x 0.156 in dia sharp tip. 5 second time constant. Type J 08517-65 Type K 08516-65 Type T 08500-65 Surface probes, 10 in long with 5/8 in dia aluminum and ceramic tip. 6 second time constant. Type J 08517-60 Type K 08516-60 Type T 08500-60 Air/gas probes, 8 in long sheath with 1/4 in dia radiant heat shield. 45 second time constant. Type J 08517-75 Type K 08516-75 Type T 08500-75 39800-98 Carrying case. Hard plastic case with foam insert holds one meter and up to five probes. Measures 21 in W x 12 in H x 3 in D. 08520-05 Soft carrying case. Water-resistant cloth. Extra room for batteries or small probe. Measures 3.5 in W x 10 in H x 2 in D.

INTRODUCTION This versatile hand-held instrument provides highly accurate temperature measurements. The instrument is designed for easy operation and includes the following features: Operator selection of Celsius or Fahrenheit scale Resolution of 0.1 from 99.9 to 299.9 Four-digit LCD Hold feature for temporarily retaining a reading Field calibration capability Low battery warning Built-in tilt stand for easy hands-free operation Two blade female ANSI mini-connector input Operates with a wide selection of probes 1

SAFETY PRECAUTIONS THIS INSTRUMENT IS WARNING DESIGNED TO ACCEPT LOW LEVEL SIGNALS SUPPLIED BY STAN- DARD THERMOCOUPLES. UNDER NO CIR- CUMSTANCES SHOULD THE INPUT VOLTAGE EXCEED THE SPECIFIED 50V RMS. DO NOT USE OR STORE CAUTION THIS INSTRUMENT IN MICROWAVE OVENS OR ANY ABNORMALLY HOT OR COLD AREAS. WEAK BATTERIES SHOULD CAUTION NOT BE LEFT IN THE IN- STRUMENT. DEAD BATTERIES CAN LEAK AND CAUSE DAMAGE TO UNIT. VOLTAGES PRESENT AT DANGER THE THERMOCOUPLE MAY ALSO BE PRESENT AT THE BATTERY TERMI- NALS. ALWAYS DISCONNECT THE THERMO- COUPLE WHEN CHANGING BATTERIES. TO PREVENT IGNITION OF WARNING A HAZARDOUS ATMOS- PHERE, BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NON-HAZARDOUS. AFIN DE PREVENIR AVERTISSEMENT L'INFLAMMATION D'ATMOSPHERES DANGEREUSES, NE CHANGER LES BATTERIES QUE DANS DES EMPLACEMENTS DESIGNES NON DAN- GEREUX. TO PREVENT IGNITION OF WARNING A HAZARDOUS ATMOS- PHERE BY ELECTROSTATIC DISCHARGE, CLEAN WITH DAMP CLOTH. 2

SPECIFICATIONS THERMOCOUPLE PROBES Type Temperature Range Type J: 200 C to 1000 C ( 328 F to 1832 F ) Type K: 250 C to 1372 C ( 418 F to 2501 F ) Type T: 250 C to 400 C ( 418 F to 752 F ) Out of range display: - - - - Resolution: 0.1 /1 autoranging, 0.1 from 99.9 to 299.9, 1 outside this range. Accuracy > 99.9 : +(0.2% of reading +0.5 C) +(0.2% of reading +0.9 F) < 99.9 : +(0.25% of reading, +1 C) +(0.25% of reading +2 F) Display: 4-digit LCD with 0.5 in high numerals. Display update rate: 0.6 sec per update. Input: One thermocouple with ANSI connector. Input Protection: 50V rms Battery: Two AA, 1.5V alkaline ANSI-L40, IEC-LR6. Battery Life: 750 hours continuous, typical. Low battery indication Battery Symbol on when 8 to 10 hours of battery life remains. Battery symbol blinking: replace battery Operating Conditions Stated accuracy: 18 C to 28 C (64 F to 82 F) Useful range: 0 C to 40 C (32 F to 104 F) Storage: 40 C to 65 C ( 40 F to 149 F) Humidity (non-condensing): 10% to 90% 3

Dimensions 3 cm D x 8.4 cm W x 15.8 cm H (1.2 in x 3.3 in x 6.2 in) Weight with batteries: 227 grams (8 ounces) Ingress protection: Meets IEC-529 IP-54 for dust and water-resistant enclosures. Intrinsic safety This product is energy limited for intrinsically safe operation in hydrogen atmospheres per Class I, Division 1, Groups A, B, C and D hazardous (classified) locations for UL per UL913 and CSA per C22.2 No. 0-M1982 and No. 157-M1987. Maximum surface temperature: 135 C (T4); UL file No. E182612 (1997). Compliance: (For CE Mark) EN61326-1/A1: 1998 (EU EMC Directive) 4

BATTERY INSTALLATION AND REPLACEMENT CAUTION WEAK BATTERIES SHOULD NOT BE LEFT IN THE INSTRUMENT. DEAD BATTERIES CAN LEAK AND CAUSE DAMAGE TO UNIT. VOLTAGES PRESENT AT DANGER THE THERMOCOUPLE MAY ALSO BE PRESENT AT THE BATTERY TERMI- NALS. ALWAYS DISCONNECT THE THERMO- COUPLE WHEN CHANGING BATTERIES. TO PREVENT IGNITION OF WARNING A HAZARDOUS ATMOS- PHERE, BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NON-HAZARDOUS. AVERTISSEMENT AFIN DE PREVENIR L'INFLAMMATION D'ATMOSPHERES DANGEREUSES, NE CHANGER LES BATTERIES QUE DANS DES EMPLACEMENTS DESIGNES NON DAN- GEREUX. 5

If battery indicator turns on, battery life is approximately 8 to 10 hours. The battery indicator will start blinking with less than 1 hour of life remaining. AT THIS POINT, BATTERY MUST BE CHANGED. IF BATTERY VOLTAGE GOES TOO LOW, DIS- PLAY WILL GO BLANK. See SPECIFICATIONS for battery type. 1. Before changing battery, turn instrument off and disconnect thermocouple. 2. Loosen screw and lift battery cover off back of case. 3. Remove the two AA batteries. 4. Insert two new batteries observing polarity. 5. Install cover and tighten screw. 6

CONNECTING A THERMOCOUPLE Use the correct thermocouple type for your instrument. Using an incorrect thermocouple type will result in erroneous readings. Thermocouples are color coded by type using the North American ANSI Color Code as follows: TYPE J K T COLOR Black Yellow Blue Thermocouple connectors have one wide blade and one narrow blade. Do not force connector in backwards. Connect thermocouple to receptacle at top of instrument as shown in the following illustration. Thermocouple wiring polarity must be correct. If readings decrease as the temperature increases, the thermocouple wires may be reversed. The red wire is negative for thermocouple wires manufactured in North America. 7

8

9

OPERATION Note: Be sure the thermocouple you are using matches the instrument setting indicated on the unit. 1. Press the ON/OFF key. The thermometer performs a self-test and all display digits and indicators, as shown below, should remain on for approximately two seconds. 2. If a thermocouple is not connected or if the thermocouple is defective, the display will indicate OPEn. 3. Select C or F by pressing the C/ F key. Temperature scale can be switched at any time. The thermometer remembers the last selected scale the next time you turn the power on. 4. For optimum instrument accuracy, allow one minute for ambient temperature stabilization. If the unit has been stored at an extreme ambient condition, more time will be needed. Thermocouples are sensitive at the tip or measuring junction. When taking temperature measurements, allow time for the reading to stabilize. Multiplying the time constant of the probe by 5 will give you the approximate time required. Note that the readings will automatically change to 1 resolution below 99.9 or above 299.9. If desired, press the HOLD key to retain the reading on the display. Press HOLD key again for normal operation. If the display shows "- - - -" the temperature reading is out of range of the instrument. 10

FIELD CALIBRATION The thermometer is factory calibrated and does not require calibration before use. The CAL function allows single point calibration of the thermometer, at 0 C (32 F) to compensate for thermocouple offset error. It is not necessary to perform a field calibration to obtain specified meter accuracy. Use the field calibration feature to improve thermometer/ probe accuracy or to compensate for thermocouple drift. 1. Follow steps 1 through 4 in OPERATION section. 2. Pack sensing end of probe in a container tightly packed with crushed ice and filled with distilled water. Allow temperature to stabilize. 3. Press and hold the CAL key for 5 seconds to enter the calibration mode, the CAL annunciator on the display starts blinking. Release the CAL key. 4. If the measured temperature is from 10 C to 10 C (14 to 50 F), when the temperature reading is stable, press the CAL key. The CAL indicator will stop blinking and the reading will be set to 0 C (32 F). The CAL indicator will remain turned on, indicating a field calibration is active. If Err is displayed, either the displayed reading is outside the above limits or the batteries are weak. CANCELING A FIELD CALIBRATION 1. Turn the thermometer off. 2. Hold the CAL key down while pressing the ON/OFF key. The field calibration is canceled and the thermometer reverts to the default factory calibration. The CAL annunciator is now turned off. 11

FIELD CALIBRATION LOCKOUT AND RE-ENABLE The calibration lockout feature, prevents any field calibration changes. The lockout remains in effect until a lockout re-enable has been performed. Use the following procedures to lockout or re-enable the field calibration operation. Lockout Procedure 1. Turn the thermometer off. 2. Simultaneously press and hold the CAL and the C/ F keys down and momentarily press the ON/ OFF key. Continue to hold the CAL and C/ F keys for at least 5 seconds. Re-Enable Procedure 1. Turn the thermometer off. 2. Simultaneously press and hold the HOLD and the CAL keys down and momentarily press the ON/OFF key. Continue to hold the HOLD and CAL keys until the display blanks. 12

MAINTENANCE Properly used, the thermometer should maintain calibration indefinitely and not require service other than occasional cleaning of the housing and changing of the batteries. CLEANING TO PREVENT IGNITION OF WARNING A HAZARDOUS ATMO- SPHERE BY ELECTROSTATIC DISCHARGE, CLEAN WITH DAMP CLOTH. Do not clean with abrasives or solvents. Use mild detergents, never immerse nor use excessive fluid. BATTERIES If there is no display when the thermometer is turned on, check condition of the two AA batteries. Also check that the battery terminals are clean and batteries are properly installed. If replacement is necessary, refer to the BATTERY INSTALLATION AND REPLACEMENT section for replacement procedure. 13

SERVICE SUBSTITUTION OF COM- WARNING PONENTS MAY IMPAIR INTRINSIC SAFETY. LA SUBSTITUTION DE AVERTISSEMENT COMPOSANTS PEUT COM- PROMETTRE LA SECURITE INTRINSEQUE. There are no internal adjustments or user replaceable parts. If Err followed by the numbers 1 through 9 is displayed (see example below) return unit for service. Note that Err alone may be displayed during improper field calibration. Note: Serial number label is located inside battery compartment. 14 A-1925-32 Rev. F Printed in U.S.A. 060900

EU DECLARATION OF CONFORMITY Name of Apparatus: DIGI-SENSE Thermocouple Thermometer Model Numbers: 91100-00, -10 and -20 Description of Apparatus: Electronic Thermometer using a Thermocouple Probe 91100-00 (Type J), -10 (Type K) and -20 (Type T) Barnant Company declares that the above models are in conformity to the following harmonized standard and directives: Applicable Applicable Manufacturer s Directives Specifications Report Number 89/336/EEC EN61326-1/A1: TR9648 92/31/EEC 1998 93/68/EEC Manufacturer: Barnant Company Division Cole-Parmer Instrument Company 28W092 Commercial Avenue Barrington, IL 60010 USA Tel.: 847-381-7050 Manufacturer s Signature: James W. Doll Vice President, Engineering 5 October, 2000 Date 15

WARRANTY The Manufacturer warrants this product to be free from significant deviations from published specifications. If repair or adjustment is necessary within the warranty period, the problem will be corrected at no charge if it is not due to misuse or abuse on your part as determined by the Manufacturer. Repair costs outside the warranty period, or those resulting from product misuse or abuse, may be invoiced to you. The warranty period for this product is noted on the Warranty Card. PRODUCT RETURN To limit charges and delays, contact the seller or Manufacturer for authorization and shipping instructions before returning the product, either within or outside of the warranty period. When returning the product, please state the reason for the return. For your protection, pack the product carefully and insure it against possible damage or loss. Any damages resulting from improper packaging are your responsibility. TECHNICAL ASSISTANCE If you have any questions about the use of this product, contact the Manufacturer or authorized seller. Trademarks bearing the symbol in this publication are registered in the U.S. and in other countries. A-3477-51 Rev. F Printed in U.S.A. 060900