OPERATING INSTRUCTIONS MESURES. Portable sludge level measuring instrument, battery operated MES. MUDLine TGS

Similar documents
EGT MONITOR AND PROBE KIT BG FUEL SYSTEMS McDonald Road Dahlonega, GA (706) A Edition 03

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13

Thermocouple Thermometer Models

Barnant Company (Type J) (Type K) (Type T)

User Manual. NiMH/NiCd Charger N, N, N, N Series

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

No Infrared Refrigerant Leak Detector

Hand Held Pull Tester Instruction Manual Order No

Installation manual wall-mounted distributor

RUCKSACK PORTABLE USER GUIDE

Water Level Meter + Temperature

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Dräger X-am Mark II Pump External pump for multi-gas detectors

TIF8800X. Combustible Gas Detector. an spx brand. Owner s Manual. 99 Washington Street Melrose, MA Phone Toll Free

EGQ 212: Duct transducer, CO 2 and temperature

BATTERY CHARGER RS-1000 Instruction Manual

General Precautions. Personnel Precautions

Uninterruptible Power System

(Type J) (Type K) (Type T)

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

Installation manual portable distributors

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

DigiTemp. Digital Thermometer

U10 Jump Starter. User Manual

BATTERY CHARGER Instruction Manual

PureLite XStream. Self-Contained Powered Air Purifying Visor System. User Manual

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Bio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications

Sonic Meter. Soni. Operating Manual. Rev. A

Thermistor Thermometer MODEL NO

SurePower Battery Pack Guide

MODEL AP/W HIGH VOLTAGE HOLIDAY DETECTOR (NEW PRODUCT RELEASE 2015)

Instruction Manual. Vibration Calibrator VC20. Manfred Weber. Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str D Radebeul

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

CGD8800X CGD8800X220 Combustible Gas Detector

c-go 24V/6A 24V/8A 24V/12A

LTX RF LEVEL SENSOR. Instruction Manual

Digital Transformer Ratiometer

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

MODEL No s: PP3, PP3K

The D.E. Stearns Company Shreveport Louisiana U.S.A. D. E. STEARNS MODEL 14/20 REGULATED ,000 VOLT HIGH VOLTAGE HOLIDAY DETECTOR

OPERATING INSTRUCTIONS

DT304. Digital Temperature Logger INSTRUCTION MANUAL

Specification of Soneil Battery Charger

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

MPPT5012A-DUO-BT MPPT5025A-DUO-BT

Dräger X-am Pump External pump for multi-gas detectors

8000mAh Jump Starter User Manual

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Installation & Calibration

Battery Jump Pack. Instruction Manual for P/N Lithium Iron Phosphate (LiFePO4)

1.Safe testing IMPORTANT:

SurePower TM II Battery Pack Guide

Battery Booster Pack. Instruction Manual for P/N

SECTION 1 1 FEATURES ON NEW TOYOTA RAV4 EV. Overview of instruments and controls

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

IMPORTANT! DO NOT THROW AWAY THE SHIPPING CARTON AND PACKING MATERIAL

EGOLD-1000 Electronic Grease Level Detector

DIGITAL TORQUE GAUGE MODEL BTGE-G

12 VOLT 30 AMP DIGITAL SOLAR CHARGE CONTROLLER

OPERATING INSTRUCTION D. E. STEARNS MODEL 14/20 REGULATED ,000 VOLT HOLIDAY DETECTOR

INSTRUCTION MANUAL CAT Bio-Pump Plus

Bante220 Portable ph Meter Instruction Manual

Operator s Handbook for Compact High Voltage P20 & P40 POROSITY (HOLIDAY) DETECTORS

Defender 3000 Series Base Instruction Manual

ICS Integrated Cleaning System. Rechargeable Battery

Duo Charger. for BP-U Series Batteries. Owner's Manual. Please read before using this equipment.

Instruction Manual BALANCE CHARGER/DISCHARGER FOR NICD/NIMH/LITHIUM/PB BATTERIES

FOR YOUR PERMANENT FILE

MODEL 905V OPERATING INSTRUCTIONS

Jerome DOSIMETER POCKET PUMP OPERATOR S MANUAL

OD 8382 OPTICAL DISSOLVED OXYGEN AUTOCLEAN

SDS SERIES DC SUBMERISIBLE PUMPS

HEINE NT4 MED V

HI Portable Waterproof Skin ph Meter INSTRUCTION MANUAL

USER S GUIDE HIGH INTENSITY ULTRASONIC PROCESSOR

ADN-W L 10. Battery Charger. Instruction manual

BATTERY CHARGER Instruction Manual

K mAh Jump Starter

All In one uninterruptible power supply solutions

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Aqua SnakeEye. OA-09 Extended Life NiMH Battery. Operators Manual

MODEL H INSTALLATION INSTRUCTIONS

testo 108 Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Handleiding

Flashlights Unlimited Xenopus Electronix Deep Purple 405 Premium Inspection Lantern Operations Guide

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Intelligent NiMH/NiCd/Li-ion Charger TN456

Multistage Air Filtration Systems Instruction Manual

Flashlights Unlimited Xenopus Electronix Deep Purple 405 Multimode Inspection Lantern Operations Guide

Table of Contents. Product Registration 18 FAQ 19 Troubleshooting 20 Customer Support / Warranty 21

HYPERION EOS0606i-B USER S MANUAL Visit for the newest manuals and news

Chek-A-Cell TM TestEquipmentDepot.com. Instruction Manual Rev A 8/12

ASTRO ATS-8900 TABBER/STAMP AFFIXER OPERATOR MANUAL

with lcd display 12-42v

MTC Series. Marine Temperature Calibrator

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

User s Manual ENGINE IGNITION ANALYZER. General Technologies Corp.

Transcription:

MUDLine TGS Portable sludge level measuring instrument, battery operated OPERATING INSTRUCTIONS MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (+33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (+33) 01 34 10 16 05 - E-mail : info@bamo.fr PORTABLE SLUDGE LEVEL MEASURING INSTRUMENT 30-10-2006 MUDLine TGS 426 M1 01 B MES 426-01/1

CONTENTS 1 Description...................................................Page 3 2 Technical Data.....................................................3 3 CE Mark.........................................................3 4 Sludge Level Measuring Procedure.....................................4 Rapid Setup......................................................4 Measuring Procedure................................................4 5 Sensitivity adjustment...............................................4 High to low difference turbidity between clear and charged fluid or sludge......4 Increased High Sensitivity............................................4 6 Automatic storing value of immersion depth..............................4 7 Cleaning.........................................................5 8 Maintenance......................................................5 9 Battery Charger....................................................5 Charging Procedure..............................................5 Charger Functions...............................................5 10 Synopsis.........................................................6 426 M1 01 B 30-10-2006 Page 2

CAUTION: BEFORE ANY OPERATION, PLEASE READ THESE SAFETY PRECAUTIONS Do not open the housing! The device may only be connected to the included battery charger, which is described in the operating instructions! Clean the cable drum with integrated electronics with a humid duster only: do not immerse in or spray with water! 1 Description The portable MUDLine TGS is dedicated to measurements of sludge levels in settling and precipitation tanks, as well as in small effluent treatment plants. It detects the transition zone between the clear phase and the precipitated sludge, on the same time the depth is displayed and stored in memory (until the reset for the next measurement). The instrument can be set to the desired switching threshold adjusting the value with the sludge concentration" range switch and then a fine adjustment potentiometer. The instrument is functional to an immersion depth of up to 10 metres. 2 Technical Data Setting range / switching threshold Measuring range 1: Measuring range 2: Measuring accuracy: Ambient temperature: Housing and switches: standard highest sensitivity approximately 1 cm 0 +50 C Stand alone with handle ON / OFF main switch Auto switch-off after 7 min Sensitivity switch Fine adjustment potentiometer "Sensitivity" IP 44 (EN 60 529) Display: Indicators: LCD-panel 3-digits, immersion depth [cm] with measured data storage, with "low battery" signal 1 LED, red, for "Mud level detected" 1 Buzzer for "Mud level detected" Immersion probe: PVC / IP68 (10m max.) (EN 60 529) Cable: Accumulator charger supply: Dimensions: Mass: special type TPE-cable, 10 m long 230V AC (main) or 12V CC (car cigarette lighter plug) Maximum 2 h 30 min to complete a full recharging 300 x 210 x 180 mm 3500 g 3 CE Mark EMC directive (89/336/ECC), EN 50 081-1:1992, EN 50 082-2:1995 426 M1 01 B 30-10-2006 Page 3

4 Sludge Level Measuring Procedure Switch the instrument on, 002 is displayed (= offset). Rapid Setup: Set range selector switch to 1. Punch through and clear any floating sludge with a tool. Immerse the probe down to the cable gland. Set the potentiometer just below the point at which the LED lights up and the horn sounds. Measuring Procedure: Immerse the measuring probe deeper into the fluid. The horn sounds and the LED lights up when the sludge phase is reached. The immersion depth of the measuring probe can now be read from the digital display. 5 Sensitivity adjustment High to low difference turbidity between clear and charged fluid or sludge: Prepare a sample with the desired concentration of sludge in a bucket. Fill in Keep close another bucket full of clear water. Immerse the measuring probe into the sludge specimen to a depth of at least 10 cm. Adjust the potentiometer as described above. Repeat several times if necessary. Increased High Sensitivity: When the turbidity is very low for a minimal sludge concentration, you may use the Highest sensitivity range: select measuring range 2. Minimal turbidity differences are then detected. Proceed as described above to complete the adjustment. CAUTION! In this mode, the instrument detects very low turbidity differences between purified and turbid water and extremely small suspended particles! 6 Automatic storing value of immersion depth When sludge level is detected: the horn sounds continuously and the LED lights up Hold the measuring probe at this depth for approximately 5 seconds. The horn signal changes from continuous to intermittent. The LED changes from continuous to blinking mode. The probe may now be removed. The horn signal stops, but the LED continues to blink. Read the stored immersion depth value. Delete it with the on-off / reset button. The LED lights off and a value of 000 to 005 is displayed. The instrument is now ready for the next measurement. 426 M1 01 B 30-10-2006 Page 4

7 Cleaning Clean the drum with integrated electronics with a humid duster. Do not immerse it or spray water on it. The measuring probe and the cable can be cleaned under running water with a soft brush. Do not use high-pressure water blasters or steam cleaners, the submersible pressure transducer will otherwise be damaged. Use mild household cleaners only: do not use solvents or degreasing agents! 8 Maintenance The device is maintenance-free if used for its intended purpose.. 9 Battery Charger LOW BATT appears on the LCD panel when the battery is weak. The integrated, rechargeable NiMH battery can be quickly and reliably recharged with the included ACS 410 mobile battery charger. Recharging time for a fully depleted battery is about 2 h 30 min. The charger can be connected either to a 230 V mains outlet, or to a 12 V automotive cigarette lighter with the help of the included DC connector cable. Charging Procedure: Remove the dust cap from the recharging socket on the MUDLine TGS. Plug the connector cable into the charger and screw into place. Plug the charger into a 230 V mains outlet, (or to an automotive cigarette lighter via the DC connector cable). The red LED on the charger blinks for about 10 seconds, testing the battery connection. The LED then remains continuously lighting, battery is recharging. The green LED lights up and the red LED goes out: The battery is fully recharged and the charger has switched to the trickle-charge mode. If the battery is defective, the red LED continues to blink after the test phase. The yellow knob can be used to fully deplete the batteries, but this is not necessary with the NIMH batteries! CAUTION: After charging, fit on the dust cap back to the charging socket on the MUDLine TGS! Charger Functions: Recharging is monitored by a micro-controller. A test is performed before recharging, it detects defective batteries. The charger is automatically switched to the trickle-charge operating mode as soon as the batteries are fully recharged, i.e. the charger can be left connected to the MUDLine TGS for long periods of time. The yellow knob can be used to fully deplete the batteries, but this is not necessary with the NIMH batteries. 426 M1 01 B 30-10-2006 Page 5

10 Synopsis 426 M1 01 B 30-10-2006 Page 6