ZWS-BAF Series. Instruction Manual. TDK-Lambda. ZWS-BAF Series Instruction Manual A H

Similar documents
ZWS-BP Series. Instruction Manual. TDK-Lambda. ZWS-BP Series. Instruction Manual A C

HWS 15A-150A Series. Instruction Manual

ZWD100PAF Series Instruction Manual

ZWD225PAF Series Instruction Manual

LS200 Series Instruction Manual

DRB-1 Series Instruction Manual

EVS RP6020. Instruction Manual

RP Instruction Manual

DRL-1 Series Instruction Manual

PFE700SA Series Instruction Manual

TDK Lambda TEP INSTRUCTION MANUAL

CN100A110 SERIES Instruction Manual

Instruction Manual. TDK-Lambda. PFE300SA 500SA Series INSTRUCTION MANUAL

Instruction Manual PFE500F 1000F SERIES. TDK-Lambda PFE500F 1000F Series INSTRUCTION MANUAL

HWS Series Instruction Manual

PAF500F24 SERIES Instruction Manual

CN-A110 SERIES Instruction Manual

PFE1000FA Series. Instruction Manual

PAF F280 SERIES Instruction Manual

CCG Series Instruction Manual

PAF F48 SERIES Instruction Manual

PAF SERIES. Features. Model naming method PAF 500 F / Conformity to RoHS Directive. Applications. Product Line up. DC/DC Module 400W-700W PAF

Basic Characteristics Data

Basic Characteristics Data

POWER-WIN TECHNOLOGY CORP.

Basic Characteristics Data

ZWD100PAF. Conformity to RoHS Directive

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

(DC/DC) SERIES to 96.5% (typical) Product Lineup. Ordering Information. Features. General Description. Super high efficiency

*Last time buy date of PAH200H: Mar. 29, *Last time buy date of PAH50S, 75S, 100S, 150S, 200S: Dec. 2, PAH450S PAH75D

Basic Characteristics Data

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Basic Characteristics Data

POWER-WIN TECHNOLOGY CORP.

Basic Characteristics Data

<Designed to meet harmonic current regulations> Board type, ultra-small size, and low cost

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

TDK-Lambda ZWS300BAF/A

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

Basic Characteristics Data

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

PRODUCT SPECIFICATION File: EA-250U1C-10 Date: May, 25, 2005

Basic Characteristics Data

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

GB60S 60W Single Output General Purpose Series

Basic Characteristics Data

Basic Characteristics Data

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

Open Frame Power Supplies

DH50 SERIES. DATASHEET Rev. A

PRODUCT SPECIFICATION File: EA-520H1U-01 Date: Apr., 7, 2005

TDK-Lambda ZWS240BP/A SPECIFICATIONS

MODEL LEP100F-24 LEP100F-36 LEP100F-48 DC OUTPUT +24V 4.2(Peak 7)A +36V 2.8(Peak 4.7)A +48V 2.1(Peak 3.5)A

Basic Characteristics Data

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

Basic Characteristics Data

MODEL ZWS50-BAF ZWS75-BAF ZWS100-BAF ZWS150-BAF ZWS300-BAF

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

2W, Low Cost DIP, Dual Output DC/DC Converters

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

(typ.) (Range) ±18 330# 89 MPW MPW

1. DBS series. Applications Manual

300W 600W 1000W 1500W

(typ.) (Range) Load

PRODUCT SPECIFICATION File: EA-400H2U-02 Date: Feb., 16, 2005

A Caspian Technology Company all materials presented are trade mark and copyright protected by C.M.TECHNOLOGY Pty Ltd

D R C- 4 0 s e r i e s

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

PRODUCT SPECIFICATION File: EA- 400ET1-10 Date: Jul., 28, 2006

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

SPECIFICATION FSP350-60APN(85) Bronze. (Erp2013) DATE:MAY, 14, 2013 表單編號 :7000P Page1

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Features. Description. Table of Contents

Basic Characteristics Data

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Basic Characteristics Data

PRODUCT SPECIFICATION File: EA-600ETF-C10 Date: Mar. 29, 2010

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

NIGHTJAR SERIES SST-NJ520

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

Top Microsystems Proprietary Specification P/N: A190047LV6 FSM RB VA.1 SPECIFICATION

MYPMA01218RCF-CAB Non-isolated type

SST-ST75F-ESS The essential silver standard

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Basic Characteristics Data

American Power Design, Inc.

PureSine 150/300 Pure Sine Wave Inverter User s Manual

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-480 Series, 480W

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

American Power Design, Inc.

PG02S Series 2W DC/DC CONVERTER, SIP-Package

Transcription:

BEFORE USING THE POWER SUPPLY UNIT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. DNGER Never use this product in locations where flammable gas or ignitable substances are present. There are risks of igniting these substances and exploding by an arcing. WRNING Do not touch this product or its internal components while circuit is live, or shortly after shutdown. There may be high voltage or high temperature present and you may receive an electric shock or burn. While this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation. Do not make unauthorized changes to this product, otherwise you may receive an electric shock and void your warranty. Do not drop or insert anything into this product. It might cause a failure, fire and electric shock. Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. It might lead to fire and electric shock. In such cases, please contact us. Do not attempt repair by yourself, as it is dangerous for the user. Do not operate these products in the presence of condensation. It might lead fire and electric shock. CUTION This power supply is designed and manufactured for use within an end product such that it is accessible to SERVICE ENGINEERS only. Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on. Input voltage, current, power, ambient temperature and ambient humidity should be kept within specifications, otherwise the product will be damaged. Do not operate and store this product in an environment where condensation might occur. In such case, waterproof treatment is necessary. Do not use this product in environment with a strong electromagnetic field, corrosive gas or conductive substances. For applications, which require very high reliability (Nuclear related equipment, medical equipment, traffic control equipment, etc.), it is necessary to provide a fail-safe mechanism in the end equipment. Do not inject abnormal voltages into the output of this product. The injection of reverse voltage or over voltage exceeding nominal output voltage into the output terminal or signal terminal might cause damage to internal components. Never operate the product under over current or short-circuit conditions, or outside its specified Input Voltage Range. Insulation failure, smoking, burning or other damage may occur. This product contains a printed circuit board utilizing surface mounted devices. PCB stress such as bending, twisting etc. could cause damage. Therefore, please handle with care. When handling this product, hold the board edge and take care not to touch the component side. When installing this product in apparatus or equipment, mount it on spacers. The outputs of this product may, under fault conditions, exceed SELV voltage limits. Therefore the outputs must be protected in the end equipment to maintain SELV. This product has used Power Thermistor to protect the circuit from Inrush Current. Frequent repetition of input might cause damage to internal components because of generating surge current. Breaking of internal fuse is considered internal failure. In such cases, please contact us. The output power of ZWS3BF is considered to be a hazardous energy level (The voltage is 2V or more and the power is 2V or more). It must not be made accessible to users. Protection must be provided for Service Engineers against indirect contact with the output terminals and/or to prevent tools being dropped across them. While working on this product, the C input power must be switched off and the input and output voltage should be zero. The information in this document is subject to change without prior notice. Please refer to the latest version of the data sheet, etc., for the most up-to date specifications of the product. No part of this document may be copied or reproduced in any form without prior written consent of. Note: CE MRKING CE Marking, when applied to a product covered by this handbook, indicates compliance with the low voltage directive. 29--1H

1.Model name identification method ZWS BF / (*1) Option (*1) Blank : Standard type. / : With chassis and cover model. Rated Voltage /L : With chassis model. /CO2 : With coating on both sides of PCB model. Power type /R : With remote ON/OFF control model. (Option model /R : Only for ZWSBF, Series Name ZWS1BF, ZWS3BF) /T : With terminal model (Option model /T : Only for ZWS3BF) 2. Explanation ZWSBF ZWS7BF 3 2 1 COMPONENT SIDE CN1 7 6 3 2 1 COMPONENT SIDE CN1 7 6 VR1 VR1 8 8 ZWSBF ZWS1BF COMPONENT SIDE CN1 COMPONENT SIDE 3 2 1 VR1 CN2 7 6 8 3 2 1 CN2 CN3 CN1 VR1 7 6 9 9 8-1-

ZWS3BF 7 3 2 1 COMPONENT SIDE 6 9 8 1 L : C Input terminal Live line (Fuse in line.) 2 N : C Input terminal Neutral line 3 : Earth ( ) Mounting hole (hole diameter : φ3.mm) These holes are connected to terminal of. Must be connected to Chassis (Conductor) of the equipment by metal spacer. The mounting surface of the spacer should be within Maxφ8mm. Mounting hole (hole diameter : φ3.mm) These holes are not connected to terminal of. 6 : 7 - : - 8 V.DJ : voltage adjust trimmer. The output voltage rises when a trimmer is turned clockwise. 9 ON/OFF Control (Option model /R : Only for ZWSBF, ZWS1BF, ZWS3BF) 3. Connection Method Pay attention to the input wiring. If it is connected to wrong terminal, the power supply will be damaged. Input must be off when making connections. Connect terminal of input connector to protective earth terminal. The output load line and input line shall be separated to improve noise sensitivity. Do not apply stress to PCB, when connecting or removing connector. Use input/output connector (housing) specified by the table below. Use the terminal pin SVH-21T-P1.1 or BVH-21T-P1.1, when output current per connector pin is or less. Use the terminal pin SVH-1T-P1.1 or BVH-1T-P1.1, when output current per connector pin is 7 or less. Use recommended crimping tool. Connector is not included with this product. (Refer to the following page) ZWSBF ZWS7BF COMPONENT SIDE COMPONENT SIDE CN1 CN1 LOD LOD VR1 VR1-2-

ZWS3BF ZWS1BF COMPONENT SIDE CN1 COMPONENT SIDE LOD CN3 VR1 CN2 CN1 LOD CN2 VR1 ZWS3BF LOD COMPONENT SIDE Input/ Connector Model Connector Housing Pin Maker Input ( ) ( CN1 ) ( CN3 ) Common B3P-VH(LF)(SN) VHR-N (In the case of ZWSBF BP-VH(LF)(SN) VHR-N ZWS7BF B6P-VH(LF)(SN) VHR-6N ZWSBF ZWS3BF B8P-VH(LF)(SN) VHR-8N ZWS1BF B6P-VH(LF)(SN) VHR-6N ZWS1BF B7P-VH(LF)(SN) VHR-7N MX per PIN) SVH-21T-P1.1 or BVH-21T-P1.1 (In the case of 7 MX per PIN) SVH-1T-P1.1 or BVH-1T-P1.1 Remote ON/OFF Control (Option model /R : Only for ZWSBF, ZWS1BF, ZWS3BF) Model Connector Housing Pin Maker CN2 B2B-XH-M XHP-2 BXH-1T-P.6 or SXH-1T-P.6 J.S.T. J.S.T. Hand Crimping Tool Hand Crimping Tool YC-1R(J.S.T) YC-93R(J.S.T) YC-11R(J.S.T) or YRS-11(J.S.T) Pin BVH-21T-P1.1 or SVH-21T-P1.1 BVH-1T-P1.1 or SVH-1T-P1.1 BXH-1T-P.6 or SXH-1T-P.6-3-

.Explanation of Function and Precautions -1. Input Voltage Range Input voltage range is single phase 8-26VC(7-63Hz) or 12-37VDC. Input voltage, which is out of specification, might lead unit damage. For cases where conformance to various safeties required, described as -2VC (-Hz). -2. Voltage Range voltage is set the rated value at shipment. V.DJ trimmer (VR1) can adjust the output voltage within the range. voltage range is within output voltage variable range. To turn the trimmer clockwise, the output voltage will be increased. ke note when the output voltage is increased excessively, over voltage protection (OVP) function may trigger and voltage will be shut down. Furthermore, when increasing the output voltage reduce the output current so as not to exceed the maximum output power. -3. Inrush Current This series equipped Power thermistor to limit the inrush Current. This series are Power thermistor method so that higher current will flow at higher ambient temperature or re-input condition. Please select input switch and fuse carefully with the high temperature and re-input the power condition. The Inrush Current value is under cold start at 2 in the specification. -. Over Voltage Protection (OVP) The OVP function (Inverter shut down method, manual reset type) is provided. OVP function operates within ZWS-1BF 3.3V: 11% - 1%, V: 11%- 1%, 12V-8V: 11%-13% of nominal output voltage, ZWS3BF 2V : 12%-1%, 12V,1V,36V,8V : 11%-13% of nominal output voltage. When OVP triggers, the output will be shut down. To reset OVP, remove the input of power supply for a few minutes, and then re-input. In addition, the setting value of OVP is fixed and not adjustable. Pay attention not to apply higher voltage externally to the output terminal to avoid unit failure. In case of inductive load, put protective diode in series to the output power line. -. Over Current Protection (OCP) ZWSBF, ZWS7BF : Fold back limit and Hiccup mode with automatic recovery. ZWSBF, ZWS1BF : 3.3V, V Constant current limit and Hiccup mode near shorted conditions with automatic recovery. : 12V - 8V Constant current limit with automatic recovery. ZWS3BF// : 12V - 8V Constant current limit with automatic recovery. OCP function operates when the output current exceeds 1% of maximum DC output current of specification. The outputs will be automatically recovered when the overload condition is canceled. Never operate the unit under over current or shorted conditions, which may leads damage or insulation failure. OCP setting is fixed and not to be adjusted externally. -6. Ripple & Noise The standard specification for maximum ripple value is measured according to measurement circuit specified by JEIT-RC9131B. When load lines are longer, ripple will becomes larger. In this case, electrolytic capacitor, film capacitor, etc. might be necessary to use across the load terminal. The output ripple cannot be measure accurately if the probe ground lead of oscilloscope is too long. 1mm Power Supply C1 C2 Load Coaxial Cable 1.m Ω C1 :.1uF Film Cap. C2 : uf Electric Cap. C3 : 7pF Ceramic Cap. R1 : Ω R1 C3 Oscilloscope Bandwidth : MHz --

-7. Series Operation For series operation, either method () or (B) is possible. () Power Supply (B) Power Supply Load Load Load (*1) (*1) In case of (), please connect bypass diodes to prevent reverse voltage. Please select a bypass diode with maximum forward current rating more than output load current. nd maximum reveres voltage must withstand each power supply output voltage. *Series operation for ZWSBF, ZWS1BF, ZWS3BF possible without bypass diode. Never use when one of the unit not operate, which may leads damage. -8. Parallel Operation For parallel operation, method (B) is possible. () To increase the output current is not possible. Power Supply (B) To use as Back-up Power Supply 1. djust the output voltage of each power supply to be the same. 2. Set power supply output voltage higher by the forward voltage drop (Vf) of diode. Use within the specification for output voltage and output power. Power Supply Load Load -9. Isolation Test Isolation resistance between - is more than MΩat VDC. For safety operation, voltage setting of DC isolation tester must be done before the test. Ensure that the unit is fully discharged after the test. - : VDC More than MΩ ()ZWSBF, ZWS7BF Isolation Tester C(L) C(N) _ (B)ZWSBF, ZWS1BF, ZWS3BF Isolation Tester C(L) C(N) _ R(CN2) _ R(CN2) --

-1. Withstand Voltage This series is designed to withstand 3.kVC between input and output, 2.kVC between input and and VC between output and each for 1 minute. When testing withstand voltage, set current limit of the withstand voltage test equipment to 1m (output - : 2m). The applied voltage must be gradually increased from zero to the testing value and then gradually decreased for shut down. When timer is used, the power supply may be damaged by high impulse voltage at timer switch on and off. Connect input and output as follows. Input - (Dashed line) : 3.kVC 1min(1m) Input - (Solid line) : 2.kVC 1min(1m) ()ZWSBF, ZWS7BF (B)ZWSBF, ZWS1BF, ZWS3BF C(L) C(N) C(L) C(N) R(CN2) Withstand Voltage Tester Withstand Voltage Tester -R(CN2) - : VC 1min(2m) ()ZWSBF, ZWS7BF (B)ZWSBF, ZWS1BF, ZWS3BF C(L) C(N) C(L) C(N) R(CN2) Withstand Voltage Tester Withstand Voltage Tester -R(CN2) Note 1 : This product have monolithic ceramic capacitor in secondary circuit to. Some of the withstand voltage tester may generate high voltage at the matching with monolithic ceramic capacitor and may cause the unit damage. So, please check the waveform of applied voltage. Note 2 : In case of using external noise filter, capacitance between Input and might be increased. When testing withstand voltage between Input and, there is a possibility exceeding withstand voltage between and (VC). Please check the voltage between and. If the voltage exceeding withstand voltage, please add external capacitor to and. It can decrease the voltage. On the other hand, no need to check the voltage in case of and is shorted. The example of noise filter circuit that may increasing capacitance value between Input and (Capacitance value in dashed line is added.) External capacitor adding point or short point. Even in the case of V and, There is a similar effect. -6-

-11. Remote ON/OFF Control (Option model /R : ZWSBF, ZWS1BF, ZWS3BF only) Remote ON/OFF control (CN2) function is available as option. ( /R). Using this function allows the user to turn the output on and off without having to turn the C input on and off. However, for Cover & Chassis type (MODEL: ZWS-BF/) cannot be used. It is controlled by the voltage applied to R and R. This circuit is in the Secondary (output) side of the power supply unit. Do not connect in the Primary (input) side. nd this circuit is isolated from the Secondary (output). Power Supply R SW R & -R terminal condition SW ON (Higher than.v) Condition ON 1kΩ R SW OFF (Lower than.8v) OFF -R E R : External resistance E : External voltage level External voltage level: E. - 12.VDC 12. - 2.VDC External resistance : R No required 1.kΩ -7-

.Mounting Directions -1. Derating according to the Mounting Directions. Recommended standard mounting method is (). Method (B)-(F) are also possible. Refer to the output derating below. Load(%) such as below derating curve indicates output power. () Standard Mounting () (B) (C) (D) (E) (F) FIN FIN -2. Derating Make sure that the specified temperature range is maintained. CONVECTION COOLING ZWSBF 12 2-1 1 2 3 7 ZWS7BF 12 2-1 1 2 3 7 ZWSBF, ZWS1BF Load(%) 12 2-1 1 2 3 7-1 - 3 Mounting (),(B),(C) Mounting (D) Mounting (E) Mounting (F) Mounting (),(B),(C) Mounting (D) Mounting (E) 9 88 Mounting (F) 7 6 7 7 Mounting (),(B) Mounting (C) Mounting (D),(E) Mounting (F) -1-3 Mounting (),(B) Mounting (C) Mounting (D),(E) 91 83 7 Mounting (F) 82 88 7 88 77 6 7 6 3 8 7 3 3-1 - 3 7 Mounting (),(B) Mounting (C),(E) Mounting (D) Mounting (F) Mounting (),(B) Mounting (C),(E) Mounting (D) Mounting (F) 8 7 7 2-8-

ZWS3BF-12,1 12 Mounting () Mounting (B),(C) Mounting (D) Mounting (E),(F) 2-1 1 2 3 7-1 - 2 3 Mounting () Mounting (B),(C) Mounting (D) Mounting (E),(F) 8 82 68 6 2 6 36 28 7 2 2 1 ZWS3BF-2, 36, 8 12 Mounting (),(B) Mounting (C) Mounting (D) Mounting (E),(F) 2-1 1 2 3 7-1 - 1 2 7 Mounting (),(B) Mounting (C) Mounting (D) Mounting (E),(F) 68 6 86 88 73 2 6 6 6 36 28 2 2 1 FORCED IR COOLING ZWSBF, ZWS7BF, ZWSBF and ZWS1BF 12 Mounting () - (F) Cooling : Wind velocity.7m/s -1-7 Mounting () - (F) 7 Electrolytic capacitor allowable Max temparature Model ZWSBF C6 C llowable Max temparature C1 7 C (for 2V,8V) C2 7 C (for 3V-1V) 2 ZWS7BF C 7 C (for 2V,8V) 7 C (for 3V-1V) -1 1 2 3 7 ZWS3BF-12, 1 ZWSBF ZWS1BF C - C 7 C (for 2V,8V) 7 C 7 C (for 3V-1V) 12 Mounting () - (F) Cooling : Wind velocity 1.m/s -1-7 Mounting () - (F) Electrolytic capacitor allowable Max temparature Model ZWS3BF -12, 1 llowable Max temparature C6 7 C C2 7 C 2-1 1 2 3 7-9-

ZWS3BF-2, 36, 8 12 v -1-7 Mounting () - (F) Cooling : Wind velocity.7m/s Mounting () - (F) Mounting () - (F) Electrolytic capacitor allowable Max temparature Model ZWS3BF -2, 36, 8 llowable Max temparature C6 7 C C2 7 C 2-1 1 2 3 7 Cooling : Wind velocity 1.m/s -1-7 Mounting () - (F) 7 The entire component must be cooled. The maximum temperature of the electrolytic capacitor C6, C1 and C2 must keep lower than Electrolytic capacitor allowable Max temperature in the above table. s reference, set wind velocity at.7m/s (ZWS-1BF), 1.m/s (ZWS3BF-12, 1),.7m/s or 1.m/s (ZWS3BF-2, 36, 8). For ZWS3BF, maximum output power is different from convection cooling and forced air cooling. Please confirm specifications, and be careful. ZWSBF, ZWS7BF ZWSBF () C6 C1 () C2 C6 C2 ZWS1BF ZWS3BF () () C6 C1 C2 C6 C2-3. Derating curve depending on input voltage(zws3bf only) Load(%) The following input voltage derating curve assumes maximum output power is % 8 9 Input voltage (VC) -1-

-. Mounting Method Insert the spacer (Maxφ8) of height more than 8mm to lift the unit. nd use all mounting holes for the unit installation. The vibration spec is specified under this mounting condition. Please use mounting hole B as needed. Vibratility-resistant improves Mounting Holes size ZWSBF, ZWS7BF, ZWSBF, ZWS1BF ZWS3BF holes φ3.mm. holes φ3.mm. B (Input) (Input) Height more than 8mm spacer Height more than 8mm spacer llowable area by metal pieces is from each PCB corners. Refer to figure below. Condition to meet Isolation & Withstand Voltage standard. More than mm More than mm Component side PCB More than mm More than mm More than 8mm Keep mm space from the surfaces and sides of PCB. Especially, 8mm space is necessary from the solder surface. If the space is not enough, the specification of isolation and withstand will not be satisfied. ke the space in the power supply surroundings and the upper area of components to keep enough for convection cooling. More than mm -11-

should be connected to the protective earth terminal of the equipment. lso 2 mounting holes are should be connected to the Chassis (Conductor) by metal spacer. If not, the conducted noise, radiation noise and output noise will increase. - N L Protective Earth Wire Input Chassis (Conductor) Metal spacers 6. Wiring Method (1) The output load line and input line shall be separated each other and twisted individually to improve noise. (2) Use all lines as thick and short as possible to made lower impedance. (3) Noise can be reduced by attaching a capacitor to the load terminals. () For safety and EMI considerations, connect between terminal of input connector and protective earth terminal firmly. () Select the wire materials to the J.S.T connector as follows. WIRE : WG#22~WG#18 WIRE : WG#22~WG#16 7. External Fuse Rating Refer to the following fuse rating when selecting the external fuses that are to be used on input line. Surge current flows when line turns on. Have to use slow-blow or time-lag type fuse, not fast-blow fuse. Fuse rating is considered by in-rush current value at line turn-on. Do not select the fuse according to input current (RMS.) values under the actual load condition ZWSBF : 3.1 ZWS7BF : 3.1 ZWSBF : 3.1 ZWS1BF :. ZWS3BF : 6.3 8. Before concluding that the unit is at fault (1) Check if the rated input voltage is connected. (2) Check if the wiring of input and output is correct. (3) Check if the wire thickness is enough. () Check if the output current and output wattage dose not over specification. () Check if the output voltage control (V.DJ) is properly adjusted. OVP might be triggered and output shut down. (6) udible noise can be heard when input voltage waveform is not sinusoidal wave. (7) udible noise can be heard daring Dynamic-Load operation. (8) Ensure that a large capacitor is not connected on the output side. Please use within maximum capacitance shown below. (ZWS3BF is no specification.) Maximum external capacitance Model 3.3V V 12V 1V 2V 8V ZWSBF ZWS7BF 1,uF,uF 2,uF uf ZWSBF ZWS1BF 1,uF No specification -12-

9. Warranty Period Warranty Period applies for Mounting Method (). For damages occurring at normal operation within this warranty period, repair is free of charge. For other mounting methods, please inquire to. CONVECTION COOLING ZWSBF, ZWS7BF ZWS1BF ZWSBF ZWS3BF-12, 1 ZWS3BF-2, 36, 8 FORCED IR COOLING ZWSBF, ZWS7BF ZWSBF, ZWS1BF ZWS3BF Following cases are not covered by warranty. (1) Improper usage like dropping products, applying shock and defects from operation exceeding specification of the units. (2) Defects resulting from natural disaster (fire, flood etc). (3) Unauthorized modifications or repair by the buyers defects not cause by our company. -13-