North American Power Fuses

Similar documents
North American Power Fuses

UL/CSA Listed Power Fuses P F THE MOST POPULAR UL/CSA LISTED POWER FUSES TO MEET THE MOST POPULAR PROTECTION PRIORITIES

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

General Purpose US Fuses

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

UL248 North American Low Voltage Fuses

FUSES 8.1. Questions? Answers at Western US: CED-ELEV

Low-Peak 600V Class RK1

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

Application Information Need to know how? You ve turned to the right place...literally.

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

Low Voltage Fuses For Motor Protection

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6

G eneral Purpose Fuses

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Fuseology. Dual-Element, Time-Delay Fuse Operation

Bussmann. Circuit Protection Solutions

Low voltage, branch circuit fuses

High Speed Fuses. Section Contents Page

Low Voltage, Branch Circuit Rated Fuses

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

E-RATED/MEDIUM VOLTAGE FUSES

NH Solid Blades 690 VAC sizes 000 to 3

The easiest and fastest way to select and specify the right fuse

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings.

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

onlinecomponents.com

Semiconductor Fuses European Fuses

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

Special Purpose Fuses

Now - Up To 400A Mains!

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES

Control Circuit Protection

British BS 88 Fuses. High Speed Fuses. Introduction. General Information

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

Low-Peak fuses offer the industry s most advanced circuit protection

Accessories. For product data sheets, visit

HIGH-SPEED SEMICONDUCTOR FUSES CATALOG POWR-SPEED PRODUCTS HIGH-SPEED FUSES FUSE BLOCKS & HOLDERS

A. Submit manufacturer's literature and technical data before starting work.

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

ULTRASAFE Fuse Holders The safety evolution continues.

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

XT IEC Power Control Manual Motor Protectors

Application Information

N0N A 250V One-Time Class H Fuse

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate

Selection Guide. Control Circuit and Load Protection

Ferrule fuses. High Speed Fuses

Midget & Electronic Fuses

Industrial Control Transformers

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

Devices for Branch Circuits and Feeders

Specification made simple for selective coordination in a compact size

LgD Series Global Pro-tection Fuses 600 Volts AC Time Delay Amperes

Solar Combiner Solutions

Fuseology. High Speed Fuses

MAGNETIC MOTOR STARTERS

T CLASS T FUSE BLOCKS

Compact Circuit Protector (CCP) Application Note

Bussmann series Quik-Spec Coordination Panelboard

Selection Guide Motor Control Device Solutions

Fused Coordination Panelboard

Fuses Special Purpose

Medium voltage fuses Medium voltage fuses

Medium Voltage Metal-Enclosed Switches

OTEC Transfer switch open transition

Quik-Spec Coordination Panelboard Specifications

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Main Distribution Switchboard KRP-C_SP LPS-RK_SP KRP-C_SP DP1. Reduced Voltage Starter for Large Motor

1492-CB 1492-GH 1492-GS

Solar Combiner Solutions

JARD by MARS JARD by MARS

Equipment Protection. Transformers 600V or Less

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

ECET Distribution System Protection. Overcurrent Protection

Medium Voltage Metal-Enclosed Switches

KLKD SERIES 10x38 FUSES

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

JOSLYN CLARK VACUUM CONTACTORS

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

Bulletin 1489 Circuit Breakers. Selection Guide

Harmonization of IEC and North American Safety Standards

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

FUSE TECHNOLOGY Ambient temperature

Transfer switch OTEC open or delayed transition

Transcription:

North American Power Fuses The most popular North American power fuses to meet the most popular protection priorities. Your problem: Today, you need a time-delay power fuse that can handle normal surges. Tomorrow, it s a power fuse with a high interrupting rating and the added security of rejection dimensions. The day after that, one of those economical one-time power fuses will do the trick. ut where can you turn for all three? Our solution: Ferraz Shawmut s comprehensive power fuse offering covers a complete range of applications and a complete range of circuit-protection needs. Whether it s the characteristics of our Tri-onic time-delay fuses. The high current-limiting capacity of our original Amp-trap power fuses. The cost-efficient protection of our One-Time fuses. Or some other application-specific power fuse solution. Want more information fast? For more technical or applicationspecific information, please call our Power Fuse experts, at 978-462-6662; 416-252-9371 in Canada; or visit our website at us.ferrazshawmut.com. Class RK5 / Tri-onic TR & TRS DC-rated / Tri-onic TRS-RDC Class J / Amp-trap HSJ Class J / Amp-trap A4J Class L / Amp-trap A4Y Class L / Amp-trap A4T Class T / Amp-trap A3T & A6T Class RK1 / Amp-trap A2K & A6K Class RK1/Amp-trap HSRK Class G / Amp-trap AG Class CC / Amp-trap ATMR Class K-5 / OT, OTN & OTS One-time Class H / RF/RFS & RL/RLS Renewable

TRI-ONIC TR & TRS Time Delay/Class RK5 The industry s Most popular fuse for Motor circuit protection. Tri-onic SmartSpot fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product the TR and TRS current limiting time delay fuses are engineered for overcurrent protection of motors and transformers, service entrance equipment, feeder and branch circuits. Tri-onic proven time delay characteristic safely handles harmless starting currents and inrush currents associated with today s motors and transformers. Features/enefits Solid State SmartSpot Indicator Time delay for motor start-ups and transformer inrush currents without nuisance opening Current limiting for low peak let-thru current Rejection-style design prevents replacement errors (when used with recommended fuse blocks) Easy-to-read label for quick recognition and replacement Metal-embossed date and catalog number for traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings High-grade silica filler ensures fast arc quenching and high current limitation HIGHLIGHTS: Applications: Time Delay Current Limiting AC & DC Rated Motor Circuits Mains Feeders ranch Circuits Transformers Service Entrance Equipment General-purpose Protection Ratings TR AC: 1/10 to 600A 250VAC, 200kA I.R. DC: 1/10 to 2 8/10A & 35 to 400A, 250VDC, 20kA I.R.; 3 to 30A & 450 to 600A, 160VDC, 20kA I.R. Approvals UL Listed to Standard 248-12 File E2137 CSA Certified to Standard C22.2 No. 248.12 DC Listed to UL Standard 248 TRS only TRS AC: 1/10 to 600A 600VAC, 200kA I.R. DC: 1/10 to 12A, 600VDC, 20kA I.R.; 15 to 60A, 300VDC, 20kA I.R. 70 to 600A, 600VDC, 100kA I.R.

TRI-ONIC Time Delay/Class RK5 Fuses TR & TRS Standard Fuse Ampere Ratings, Catalog Numbers Ampere Catalog Number Ampere Catalog Number Ampere Catalog Number Rating 250V 600V Rating 250V 600V Rating 250V 600V 1/10 TR1/10R TRS1/10R 3-1/2 TR3-1/2R TRS3-1/2R 50 TR50R TRS50R 15/100 TR15/100R TRS15/100R 4 TR4R TRS4R 60 TR60R TRS60R 2/10 TR2/10R TRS2/10R 4-1/2 TR4-1/2R TRS4-1/2R 70 TR70R TRS70R 3/10 TR3/10R TRS3/10R 5 TR5R TRS5R 75 TR75R TRS75R 4/10 TR4/10R TRS4/10R 5-6/10 TR5-6/10R TRS5-6/10R 80 TR80R TRS80R 1/2 TR1/2R TRS1/2R 6 TR6R TRS6R 90 TR90R TRS90R 6/10 TR6/10R TRS6/10R 6-1/4 TR6-1/4R TRS6-1/4R 100 TR100R TRS100R 8/10 TR8/10R TRS8/10R 7 TR7R TRS7R 110 TR110R TRS110R 1 TR1R TRS1R 8 TR8R TRS8R 125 TR125R TRS125R 1-1/8 TR1-1/8R TRS1-1/8R 9 TR9R TRS9R 150 TR150R TRS150R 1-1/4 TR1-1/4R TRS1-1/4R 10 TR10R TRS10R 175 TR175R TRS175R 1-4/10 TR1-4/10R TRS1-4/10R 12 TR12R TRS12R 200 TR200R TRS200R 1-6/10 TR1-6/10R TRS1-6/10R 15 TR15R TRS15R 225 TR225R TRS225R 1-8/10 TR1-8/10R TRS1-8/10R 17-1/2 TR17-1/2R TRS17-1/2R 250 TR250R TRS250R 2 TR2R TRS2R 20 TR20R TRS20R 300 TR300R TRS300R 2-1/4 TR2-1/4R TRS2-1/4R 25 TR25R TRS25R 350 TR350R TRS350R 2-1/2 TR2-1/2R TRS2-1/2R 30 TR30R TRS30R 400 TR400R TRS400R 2-8/10 TR2-8/10R TRS2-8/10R 35 TR35R TRS35R 450 TR450R TRS450R 3 TR3R TRS3R 40 TR40R TRS40R 500 TR500R TRS500R 3-2/10 TR3-2/10R TRS3-2/10R 45 TR45R TRS45R 600 TR600R TRS600R Note: Indicator not available (1/10-7) amps. 0-60A 61-600A Dimensions AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm 250V-TR FUSES 0-30 2 51 9/16 14 - - - - - - 31-60 3 76 13/16 21 - - - - - - 61-100 5-7/8 149 1-1/16 27 1/8 3 3/4 19 1 25 101-200 7-1/8 181 1-9/16 40 3/16 5 1-1/8 28 1-3/8 35 201-400 8-5/8 219 2-1/16 53 1/4 6 1-5/8 41 1-7/8 48 401-600 10-3/8 264 2-9/16 66 1/4 6 2 51 2-1/4 57 600V-TRS FUSES 0-30 5 127 13/16 21 - - - - - - 31-60 5-1/2 139 1-1/16 27 - - - - - - 61-100 7-7/8 200 1-5/16 34 1/8 3 3/4 19 1 25 101-200 9-5/8 244 1-13/16 46 3/16 5 1-1/8 28 1-3/8 35 201-400 11-5/8 295 2-9/16 66 1/4 6 1-5/8 41 1-7/8 48 401-600 13-3/8 340 3-1/8 80 1/4 6 2 51 2-1/4 57 Recommended Fuse locks With ox Connectors For Tri-onic Class RK5 Fuses Fuse Catalog Number Ampere 250V 600V Rating 1 Pole 3 pole 1 pole 3 pole 0-30 20306R 20308R 60306R 60308R 31-60 20606R 20608R 60606R 60608R 61-100 21036R 21038R 61036R 61038R 101-200 22001R 22003R 62001R 62003R 201-400 24001R 24003R 64001R 64003R 401-600 2631R 2633R 6631R 6633R

TRI-ONIC Time Delay/Class RK5 Fuses TR & TRS TR15 to 600 Time in Seconds TR1/10 to 12 Melting Time Current Data, 250V Fuses Current in Amperes Melting Time Current Data, 250V Fuses Current in Amperes Time in Seconds

TRI-ONIC Time Delay/Class RK5 Fuses TR & TRS TRS15 to 600 Melting Time Current Data, 600V Fuses Current in Amperes Time in Seconds TRS1/10 to 12 Melting Time Current Data. 600V Fuses Current in Amperes Time in Seconds

TRI-ONIC Time Delay/Class RK5 Fuses TR & TRS Peak Let-Thru Current Data TR30 to 600, 250 Volts AC Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes Peak Let-Thru Current Data TRS15 to 600, 600 Volts AC Maximum Instantaneous Peak Let-Thru Amperes Note: See Application Information page L9 for All Motor and Transformer Tables. Available Current in RMS Symmetrical Amperes

tri-onic TRS-RDC time delay/dc rated DC RATED FOR TOUGH DC APPLICATIONS The Tri-onic DC fuse series is designed for DC circuit protection in surface and underground mines. The TRS-RDC is MSHA approved and meets the industry s most severe third party requirements for 600VDC rated fuses. The TRS-RDC is a time-delay fuse with essentially the same time-current characteristic as the standard Tri-onic. Features/enefits DC rated for mine duty and other long time-constant applications Time delay for motor start-ups and high inrush loads without nuisance opening Rugged glass melamine body for superior Reliability in harsh environments HIGHLIGHTS: Applications: Ratings Approvals Time Delay DC Rated Mine Circuits Trailing Cables Pump Motors Rail Heaters DC: 1 to 30A 300VDC, 20kA I.R. (Consult Factory for Availability) DC: 35 to 400A 600VDC, 20kA I.R. MSHA Approval No. 28-26-0

TRI-ONIC Time Delay/600VDC Fuses TRS-RDC Standard Fuse Ampere Ratings, Catalog Numbers AMPERE CATALOG RATING NUMER 1/10 TRS1/10RDC 15/100 TRS15/100RDC 2/10 TRS2/10RDC 3/10 TRS3/10RDC 4/10 TRS4/10RDC 1/2 TRS1/2RDC 6/10 TRS6/10RDC 8/10 TRS8/10RDC 1 TRS1RDC 1-1/8 TRS1-1/8RDC AMPERE CATALOG RATING NUMER 1-1/4 TRS1-1/4RDC 1-4/10 TRS1-4/10RDC 1-6/10 TRS1-6/10RDC 1-8/10 TRS1-8/10RDC 2 TRS2RDC 2-1/4 TRS2-1/4RDC 2-1/2 TRS2-1/2RDC 2-8/10 TRS2-8/10RDC 3 TRS3RDC 3-2/10 TRS3-2/10RDC AMPERE CATALOG RATING NUMER 3-1/2 TRS3-1/2RDC 4 TRS4RDC 4-1/2 TRS4-1/2RDC 5 TRS5RDC 5-6/10 TRS5-6/10RDC 6 TRS6RDC 6-1/4 TRS6-1/4RDC 8 TRS8RDC 9 TRS9RDC 10 TRS10RDC AMPERE CATALOG RATING NUMER 12 TRS12RDC 15 TRS15RDC 17-1/2 TRS17-1/2RDC 20 TRS20RDC 30 TRS30RDC 35 TRS35RDC 40 TRS40RDC 45 TRS45RDC 50 TRS50RDC 60 TRS60RDC AMPERE CATALOG RATING NUMER 70 TRS70RDC 80 TRS80RDC 90 TRS90RDC 100 TRS100RDC 125 TRS125RDC 150 TRS150RDC 175 TRS175RDC 200 TRS200RDC 250 TRS250RDC 300 TRS300RDC 400 TRS400RDC 0-60 Amperes Dimensions 61-400 Amperes AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm 0-30 5 127 13/16 21 - - - - - - 31-60 5-1/2 139 1-1/16 27 - - - - - - 61-100 7-7/8 200 1-5/16 34 1/8 3 3/4 19 1 25 101-200 9-5/8 244 1-13/16 46 3/16 5 1-1/8 28 1-3/8 35 201-400 11-5/8 295 2-9/16 66 1/4 6 1-5/8 41 1-7/8 48 TRS-RDC60 to 400 Melting Time Current Data, 600V Fuses Current in Amperes Time in Seconds

HSJ HIGH SPEED/CLASS J Protect your wiring and power semiconductors with a single fuse. The new High Speed J (HSJ) combines the low I 2 t of a semiconductor fuse and the branch circuit performance of a Class J UL listed fuse. This fuse was designed for the starting characteristics of solid state motor controllers. The HSJ can provide branch circuit protection per NEC requirements, as well as very low I 2 t for protection of power semiconductors such as Diodes, SCR s, GTO s and SSR s. Features/enefits Optimized over-load capability for withstanding elevated levels of current during electronic motor controller starts Low I 2 t (low thermal energy) Excellent Cycling Ability for frequent starts/stops without nuisance opening Ratings Approvals HIGHLIGHTS: Current-Limiting AC & DC Ratings Low l 2 t Compact Size Applications: ranch Circuits Control Panels Electronic Motor Controllers Phase Controllers Drives Soft-Starters Solid State Relays AC: 1-600A 600VAC, 200kA I.R. 300kA I.R. Self Certified DC: 15-600A 500VDC, 100kA I.R. L/R 10mS HSJ (15 to 600A) UL Listed to Standard 248-8 File E2137 DC Listed to UL248 CSA Certified to Standard C22.2 No. 248.8

HIGH SPEED/CLASS J HSJ Standard Fuse Ampere Ratings, Catalog Numbers AMPERE RATING CATALOG NUMER OUTLINE FIGURE AMPERE RATING CATALOG NUMER OUTLINE FIGURE 1 HSJ1 1 90 HSJ90 2 3 HSJ3 1 100 HSJ100 2 6 HSJ6 1 110 HSJ110 2 10 HSJ10 1 125 HSJ125 2 15 HSJ15 1 150 HSJ150 2 17-1/2 HSJ17-1/2 1 175 HSJ175 2 20 HSJ20 1 200 HSJ200 2 25 HSJ25 1 225 HSJ225 2 30 HSJ30 1 250 HSJ250 2 35 HSJ35 1 300 HSJ300 2 40 HSJ40 1 350 HSJ350 2 45 HSJ45 1 400 HSJ400 2 50 HSJ50 1 450 HSJ450 2 60 HSJ60 1 500 HSJ500 2 70 HSJ70 2 600 HSJ600 2 80 HSJ80 2 Recommended Fuse locks With ox Connectors for Amp-trap Class J Fuses Fuse Ampere Catalog Number 600V OR LESS Rating 1 Pole 3 pole 0-30 US3J1I US3J3I 31-60 US6J1I US6J3I 61-100 61036J 61038J 101-200 62001J 62003J 201-400 64031J 64033J 401-600 6631J 6633J A variety of pole configurations and termination provisions is available. Dimensions Fig 1 Fig 2 AMPERE RATING A C D E F G H In. mm In. mm In. mm In. mm In. mm In. mm In. mm In. mm 15-30 2-1/4 57 13/16 21 - - - - - - - - - - - - 31-60 2-3/8 60 1-1/16 27 - - - - - - - - - - - - 61-100 4-4/8 117 1-1/8 29 1/8 3.2 3/4 19 1 25 3-5/8 92 3/8 10 9/32 7 101-200 5-3/4 146 1-5/8 41 3/16 4.8 1-1/8 29 1-3/8 35 4-3/8 111 3/8 10 9/32 7 201-400 7-1/8 181 2-1/8 54 1/4 6.3 1-5/8 41 1-7/8 48 5-1/4 133 17/32 13 13/32 10 401-600 8 203 2-1/2 64 3/8 9.5 2 51 2-1/8 54 6 152 11/16 18 17/32 13 10

HIGH SPEED/CLASS J HSJ I 2 t Data - 600 Volts AC, 100kA Max Clearing I 2 t @ Max Clearing I 2 t @ Watts Ampere 600V AC 100kA 480V AC 100kA Loss at Rating Pre-Arc 1 Fuse 2 in Series 1 Fuse 2 in Series Rated (A) (A 2 s x 10 3 ) (A 2 s x 10 3 ) (A 2 s x 10 3 ) (A 2 s x 10 3 ) (A 2 s x 10 3 ) Current 15 0.02 0.36 0.15 0.23 0.12 2.6 17.5 0.03 0.45 0.19 0.29 0.15 3.5 20 0.04 0.58 0.24 0.37 0.19 3.7 25 0.08 1.2 0.50 0.77 0.40 4 30 0.16 2 0.84 1.3 0.66 4.1 35 0.16 1.5 0.63 0.96 0.50 5.3 40 0.27 2.3 1.0 1.5 0.76 5.5 45 0.32 3.3 1.4 2.1 1.1 6 50 0.44 5.5 2.3 3.5 1.8 6.8 60 0.72 8.0 3.4 5.1 2.6 8.4 70 1.2 12 5.0 7.7 4.0 10 80 1.6 15 6.3 9.6 5.0 11 90 2.3 21 8.8 13 6.9 13 100 2.7 23 9.7 15 7.6 14 110 2.3 21 10 13.9 8 18 125 3.4 29 14 19 11 19 150 5.1 41 20 27 16 22 175 8.0 60 29 40 23 24 200 14 92 44 61 35 26 225 14 110 53 73 42 30 250 16 130 62 86 49 36 300 26 200 96 132 76 38 350 37 290 139 191 110 40 400 63 450 216 297 171 42 450 67 500 240 330 190 58 500 98 600 288 396 228 59 600 141 900 432 594 342 68 Clearing I 2 t vs Operating Voltage Watts Loss vs. % Rated Current 1.0 1.0 Correction Factor for I2t.8.6.4.2 110-600 AMP 15-100 AMP Correction Factor for Watts Loss.8.6.4.2 0 0 100 200 300 400 500 600 50 60 70 80 90 100 Operating Voltage (AC RMS Volts) Percent Rated Current 11

HIGH SPEED/CLASS J HSJ Peak Let-Thru Data - HSJ15 to 600, 600Volts AC Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes Clearing I 2 t at 500 VDC 100kA, L/R = 10mS DC Voltage vs. Time Constant AMPERE RATING CLEARING I 2 t @ 500 VDC L/R = 10 ms (A 2 s X 10 3 ) 15 0.12 17.5 0.18 20 0.24 25 0.46 30 0.91 35 0.60 40 0.92 45 1.3 50 2.2 60 3.2 70 4.8 80 6.2 90 8.9 100 10 110 8.8 125 13 150 19 175 28 200 46 225 52 250 59 300 96 350 136 400 230 450 270 500 390 600 560 DC Voltage Capability L/R Time Constant (ms) 12

HIGH SPEED/CLASS J HSJ Melting Time - Current Data, HSJ15 to 600, 600Volts AC Time in Seconds Available Current in RMS Symmetrical Amperes Time in Seconds Available Current in RMS Symmetrical Amperes 13

A4J FAST ACTING/Class J For excellent CURRENT LIMITING PROTECTION A4J Class J fuses deliver excellent current-limiting protection to a wide variety of applications. Their unique dimensions prevent the substitution of other fuses with lower voltage ratings, interrupting ratings, or current-limiting capability. Features/enefits High current limitation for low peak let-thru current Unique dimensions prevent replacement by other fuse classes Fiberglass body provides dimensional stability in harsh industrial environments Easy-to-read imprint label for quick recognition and replacement HIGHLIGHTS: Applications: Ratings Approvals Fast Acting Very Current-Limiting DC Ratings Capacitors Loadcenters Panelboards Switchboards us Duct Feeder Circuits Circuit reakers Lighting, Heating, and General Loads AC: 1 to 600A 600VAC, 200kA I.R. DC: 1 to 600A 300VDC, 100kA I.R. UL Listed to Standard 248-8 File E2137 CSA Certified to Standard C22.2 No. 248.8 DC Listed to UL 248 IEC 269-2-1 14

fast acting/class J Fuses A4J Standard Fuse Ampere Ratings, Catalog Numbers AMPERE CATALOG AMPERE CATALOG AMPERE CATALOG RATING NUMER RATING NUMER RATING NUMER 1 A4J1 50 A4J50 200 A4J200 3 A4J3 60 A4J60 225 A4J225 6 A4J6 70 A4J70 250 A4J250 10 A4J10 75 A4J75 300 A4J300 15 A4J15 80 A4J80 350 A4J350 20 A4J20 90 A4J90 400 A4J400 25 A4J25 100 A4J100 450 A4J450 30 A4J30 110 A4J110 500 A4J500 35 A4J35 125 A4J125 600 A4J600 40 A4J40 150 A4J150 45 A4J45 175 A4J175 Recommended Fuse locks With ox Connectors for Amp-trap Class J Fuses 1-60A 61-600A Fuse Ampere Catalog Number 600V OR LESS Rating 1 Pole 3 pole 0-30 US3J1I US3J3I 31-60 US6J1I US6J3I 61-100 61036J 61038J 101-200 62001J 62003J 201-400 64031J 64033J 401-600 6631J 6633J A variety of pole configurations and termination provisions are available. Refer to the fuse block section of this catalog for details. Dimensions AMPERE a C D e F G H RATING In. mm In. mm In. mm In. mm In. mm In. mm In. mm In. mm 1-30 2-1/4 57 13/16 21 - - - - - - - - - - - - 31-60 2-3/8 60 1-1/16 27 - - - - - - - - - - - - 61-100 4-5/8 117 1-1/8 29 1/8 3.2 3/4 19 1 25 3-5/8 92 3/8 10 9/32 7 101-200 5-3/4 146 1-5/8 41 3/16 4.8 1-1/8 29 1-3/8 35 4-3/8 111 3/8 10 9/32 7 201-400 7-1/8 181 2-1/8 54 1/4 6.3 1-5/8 41 1-7/8 48 5-1/4 133 17/32 13 13/32 10 401-600 8 203 2-1/2 64 3/8 9.5 2 51 2-1/8 54 6 152 11/16 18 17/32 13 15

fast acting/class J Fuses A4J A4J30 to 600 Maximum Instantaneous Peak Let-Thru Amperes Melting Time Current Data, 600V Fuses Current in Amperes Time in Seconds Peak Let-Thru Current Data 30 to 600, 600 Volts AC Available Current in RMS Symmetrical Amperes 16

A4Y CLASS l count on the high interrupting rating of our most widely-used class L fuse When it comes to protecting service entrance equipment, feeder circuits, and circuit breakers, A4Y fuses have been the industry s favorite. The A4Y is a 100% rated device and may be applied at continuous currents up to its ampere rating. A 4-second minimum time delay at 500% rating allows the A4Y to pass normal current surges and to coordinate with ground fault relays. Features/enefits Unique dimensions prevent replacement by other fuse classes lade stamped catalog numbers for permanent identification Glass melamine body and plated terminals provide superior reliability in harsh environments HIGHLIGHTS: Applications: Ratings Approvals Current-Limiting 4-Second Time Delay DC Ratings Uniform Characteristics in all Ampere Ratings Mains, Feeders Circuit reakers Loadcenters Panelboards Switchboards Metering Centers AC: 200 to 6,000A 600VAC,200kA I.R. DC: 200 to 2500A 300VDC, 100kA I.R. UL Listed to Standard 248-10 (601-6000A) File E2137 CSA Certified to Standard C22.2 No. 248.10 (601-6000A) Ferraz Shawmut Certified for DC per UL248 (601-6000A) Indicators Optional built-in fuse indicators (-TI) are available. Consult factory. 17

Class L Fuses A4Y Standard Fuse Ampere Ratings, Catalog Numbers AMPERE CATALOG AMPERE CATALOG AMPERE CATALOG RATING NUMER RATING NUMER RATING NUMER 200 A4Y200 801 A4Y801 2000 A4Y2000 250 A4Y250 900 A4Y900 2001 A4Y2001 300 A4Y300 1000 A4Y1000 2200 A4Y2200 350 A4Y350 1100 A4Y1100 2500 A4Y2500 400 A4Y400 1200 A4Y1200 3000 A4Y3000 450 A4Y450 1201 A4Y1201 3001 A4Y3001 500 A4Y500 1350 A4Y1350 3500 A4Y3500 600 A4Y600 1400 A4Y1400 4000 A4Y4000 601 A4Y601 1500 A4Y1500 4001 A4Y4001 650 A4Y650 1600 A4Y1600 4500 A4Y4500 700 A4Y700 1601 A4Y1601 5000 A4Y5000 750 A4Y750 1800 A4Y1800 6000 A4Y6000 800 A4Y800 2001-3000A 3001-4000A 4001-6000A 200-800A 801-2000A Dimensions AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm 200-600 8-5/8 219 2 51 5/16 8 1-5/8 41 2-13/32 61 601-800 8-5/8 219 2-1/2 63 3/8 9 2 51 2-13/32 61 801-1200 10-3/4 273 2-1/2 63 3/8 9 2 51 3-15/32 88 1201-1600 10-3/4 273 3 76 7/16 11 2-3/8 60 3-15/32 88 1601-2000 10-3/4 273 3-1/2 89 1/2 13 2-3/4 70 3-15/32 88 2001-2500 10-3/4 273 4-1/2 114 3/4 19 3-1/2 89 3-15/32 88 2501-3000 10-3/4 273 5 127 3/4 19 4 102 3-15/32 88 3001-4000 10-3/4 273 5-3/4 146 3/4 19 4-3/4 121 3-15/32 88 4001-5000 10-3/4 273 6-1/4 159 1 25 5-1/4 133 3-15/32 88 5001-6000 10-3/4 273 7-1/8 181 1 25 5-3/4 146 3-15/32 88 Safety Note: Class L fuses are dimensioned for one-way interchangeability. A Class L fuse of any lower ampere rating can be substituted for a given Class L fuse. 18

Class L Fuses A4Y A4Y200 to 6000 Melting Time Current Data, 600V Fuses Current in Amperes Time in Seconds Peak Let-Thru Current Data A4Y300 to 6000, 600 Volts AC Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes 19

A4T TIME DELAY/CLASS L when your heavier loads need protection a4t fuses won t let you down The high interrupting rating of A4T current limiting fuses is ideally suited for protecting mains, feeders, and general circuits. The 10-second time delay at 500% of fuse rating is ideal for large motors and other loads with a high inrush. A4T fuses are suitable for DC applications up to 500VDC. An A4T fuse can be applied to normal loads up to its full ampere rating to allow 100% rating of equipment. Features/enefits Unique dimensions prevent replacement by other fuse classes. lade-stamped catalog numbers for permanent identification Glass melamine body and plated terminals provide superior reliability in harsh environments HIGHLIGHTS: Applications: Ratings Approvals Current-Limiting Full 10-Second Delay DC Ratings Uniform Characteristics in all Ampere Ratings Motors Motor Controllers Transformers Mains Feeders AC: 200 to 2,000A 600VAC, 200kA I.R. DC: 200 to 2,000A 500VDC, 100kA I.R. UL Listed to Standard 248-10 (601-2000A) File E2137 CSA Certified to Standard C22.2 No. 248.10 (601-2000A) Ferraz Shawmut Certified for DC per UL248 (601-2000A) 20

Time Delay/Class L Fuses A4T Standard Fuse Ampere Ratings, Catalog Numbers AMPERE CATALOG AMPERE CATALOG AMPERE CATALOG RATING NUMER RATING NUMER RATING NUMER 200 A4T200 601 A4T601 1100 A4T1100 250 A4T250 650 A4T650 1200 A4T1200 300 A4T300 700 A4T700 1400 A4T1400 350 A4T350 750 A4T750 1500 A4T1500 400 A4T400 800 A4T800 1600 A4T1600 450 A4T450 900 A4T900 1800 A4T1800 500 A4T500 1000 A4T1000 2000 A4T2000 600 A4T600 200-800A 801-2000A Dimensions AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm 200-600* 8-5/8 219 2 51 5/16 8 1-5/8 41 2-13/32 61 601-800 8-5/8 219 2-1/2 63 3/8 9 2 51 2-13/32 61 801-1200 10-3/4 273 2-1/2 63 3/8 9 2 51 3-15/32 88 1201-1600 10-3/4 273 3 76 7/16 11 2-3/8 60 3-15/32 88 1601-2000 10-3/4 273 3-1/2 89 1/2 13 2-3/4 70 3-15/32 88 Safety Note: Class L fuses are dimensioned for one-way interchangeability. A Class L fuse of any lower ampere rating can be substituted for a given Class L fuse. 21

Time delay/class l Fuses A4T A4T200 to 2000 Time in Seconds Maximum Instantaneous Peak Let-Thru Amperes Melting Time Current Data, 600V AC/500V DC Fuses Current in Amperes Peak Let-Thru Current Data A4T300 to 2000, 600 Volts AC Available Current in RMS Symmetrical Amperes 22

A3T & A6T fast acting/class T these small dimension fuses are the right fit... for a tight fit Fast acting A3T and A6T Class T fuses combine two highly desirable features -- high current limitation and a small physical size. Their unique dimensions prevent the substitution of other fuses with lower voltage ratings or current limiting capability. These fuses have glass melamine bodies for superior dimensional stability and catalog numbers stamped into the blades for permanent identification. Features/enefits Extremely current limiting for low peak let-thru current Unique dimensions prevent replacement by other fuse classes lade-stamped catalog numbers for permanent identification Small physical size for greater design flexibility HIGHLIGHTS: Fast Acting Extremely Current Limiting Small Physical Size DC Ratings Applications: Loadcenters Panelboards Switchboards Circuit reakers Metering Centers Recommended Fuse locks With ox Connectors for Amp-trap Class T Fuses Ampere Rating 30 60 100 200 400 600 1-pole 30306T 30606T 31031T 32031T 34031T 36031T Catalog Number 300V 3-pole 1-pole 30308T 60306T 30608T 60606T 31033T 61031T 32033T 62031T 34033T 64031T 66031T A variety of pole configurations and termination provisions are available. Refer to the fuse block section of this catalog for details. 600V 3-pole 60308T 60608T 61033T 62033T Ratings A3T AC:1 to 1200A 300VAC, 200kA I.R. DC: 1 to 1200A 160VDC, 50kA I.R. A6T AC: 1 to 800A 600VAC, 200kA I.R. DC: 1 to 800A 300VDC, 100kA I.R. Approvals UL Listed to Standard 248-15 File E2137 CSA Certified to Standard C22.2 No. 248.15 DC Listed to UL Standard 248 23

fast acting/class t Fuses A3T & A6T Standard Fuse Ampere Ratings, Catalog Numbers Ampere Catalog Number Ampere Catalog Number Ampere Catalog Number Rating 300V 600V Rating 300V 600V Rating 300V 600V 1 A3T1 A6T1 60 A3T60 A6T60 300 A3T300 A6T300 3 A3T3 A6T3 70 A3T70 A6T70 350 A3T350 A6T350 6 A3T6 A6T6 80 A3T80 A6T80 400 A3T400 A6T400 10 A3T10 A6T10 90 A3T90 A6T90 450 A3T450 A6T450 15 A3T15 A6T15 100 A3T100 A6T100 500 A3T500 A6T500 20 A3T20 A6T20 110 A3T110 A6T110 600 A3T600 A6T600 25 A3T25 A6T25 125 A3T125 A6T125 700 A3T700 A6T700 30 A3T30 A6T30 150 A3T150 A6T150 800 A3T800 A6T800 35 A3T35 A6T35 175 A3T175 A6T175 1000 A3T1000 40 A3T40 A6T40 200 A3T200 A6T200 1200 A3T1200 45 A3T45 A6T45 225 A3T225 A6T225 50 A3T50 A6T50 250 A3T250 A6T250 A3T A6T A3T 1-60 A6T 1-30 A6T 31-60 A3T 61-1200 Dimensions A6T 61-800 AMPERE A C D F G J RATING In. mm In. mm In. mm In. mm In. mm In. mm In. mm A3T 1-30.88 22.4.41 10.3 - - - - - - - - - - 31-60.88 22.4.56 14.1 - - - - - - - - - - 61-100 2.16 54.9.81 20.6.12 3.2.75 19.0 1.56 39.6.28 7.1.82 20.8 101-200 2.44 62.0 1.06 26.9.19 4.8.88 22.4 1.70 43.2.34 8.6.83 21.1 201-400 2.75 69.8 1.33 33.8.25 6.4 1.00 25.4 1.84 46.7.41 10.4.84 21.3 401-600 3.06 77.7 1.62 41.1.31 7.8 1.25 31.8 2.03 51.6.48 12.2.84 21.3 601-800 3.38 85.8 2.08 52.8.38 9.7 1.75 44.4 2.22 56.4.55 14.0.88 22.4 801-1200 4.00 102 2.52 64.0.44 11.2 2.00 50.8 2.53 64.3.61 15.5 1.03 26.2 A6T 1-30 1.50 38.1.57 14.5 - - - - - - - - - - 31-60 1.57 39.9.81 20.6 1.51 38.4 1.00 25.4 - - - - - - 61-100 2.95 75.0.82 20.8.12 3.2.75 19.0 2.35 59.7.28 7.1 1.58 40.1 101-200 3.26 82.8 1.07 27.2.19 4.8.88 22.4 2.51 63.7.34 8.6 1.61 41.0 201-400 3.62 92.1 1.62 41.3.25 6.4 1.00 25.4 2.72 69.1.41 10.4 1.70 43.2 401-600 3.98 101.2 2.06 52.4.31 7.9 1.25 31.8 2.95 75.0.48 12.2 1.70 43.2 601-800 4.33 110.0 2.50 63.5.37 9.5 1.75 44.4 3.17 80.5.56 14.1 1.70 43.2 24

fast acting/class t Fuses A3T & A6T A3T30 to 1200 Melting Time Current Data, 300V Fuses Current in Amperes Time in Seconds Peak Let-Thru Current Data A3T30 to 1200, 300 Volts AC Maximum Instantaneous Peak Let-Thru Amperes 25

fast acting/class t Fuses A3T & A6T A6T1 to 800 Current in Amperes Time in Seconds Maximum Instantaneous Peak Let-Thru Amperes Melting Time Current Data, 600V Fuses Peak Let-Thru Current Data A6T30 to 800, 600 Volts AC Available Current in RMS Symmetrical Amperes 26

A2K & A6K class RK1 these FAST-ACTING FUSES DELIVER A HIGH DEGREE OF CURRENT LIMITATION WHERE YOU NEED IT MOST Current-limiting A2K and A6K fuses provide excellent protection where high available short circuit currents exist. These fast-acting fuses are particularly good for branch/feeder circuits and back-up protection. Features/enefits Rejection style design prevents replacement by other fuse classes Fiberglass body provides dimensional stability in harsh industrial environments Easy-to-read imprint label for quick recognition and replacement High degree of current limitation for low peak let-thru current HIGHLIGHTS: Applications: Ratings Approvals Highly Current-Limiting Fast Acting Rejection Style Loadcenters Panelboards Switchboards us Duct Feeder Circuits Non-inductive Loads Lighting Circuits A2K AC: 1 to 600A 250VAC, 200kAI.R. DC: 1 to 600A 250VDC, 200kA I.R. A6K AC: 1 to 600A 600VAC, 200kA I.R. DC: 1 to 600A 300VDC, 20kA I.R. UL Listed to Standard 248-12 File E2137 CSA Certified to Standard C22.2 No. 248.12 Ferraz Shawmut Certified for DC per UL248 27

fast acting/class rk1 Fuses A2k & A6k Standard Fuse Ampere Ratings, Catalog Numbers Ampere Catalog Number Ampere Catalog Number Ampere Catalog Number Rating 250V 600V Rating 250V 600V Rating 250V 600V 1 A2K1R A6K1R 35 A2K35R A6K35R 175 A2K175R A6K175R 3 A2K3R A6K3R 40 A2K40R A6K40R 200 A2K200R A6K200R 4 - A6K4R 45 A2K45R A6K45R 225 A2K225R A6K225R 5 A2K5R A6K5R 50 A2K50R A6K50R 250 A2K250R A6K250R 6 A2K6R A6K6R 60 A2K60R A6K60R 300 A2K300R A6K300R 8 - A6K8R 70 A2K70R A6K70R 350 A2K350R A6K350R 10 A2K10R A6K10R 80 A2K80R A6K80R 400 A2K400R A6K400R 12 A2K12R - 90 A2K90R A6K90R 450 A2K450R A6K450R 15 A2K15R A6K15R 100 A2K100R A6K100R 500 A2K500R A6K500R 20 A2K20R A6K20R 110 A2K110R A6K110R 600 A2K600R A6K600R 25 A2K25R A6K25R 125 A2K125R A6K125R 30 A2K30R A6K30R 150 A2K150R A6K150R Recommended Fuse locks With ox Connectors For Amp-trap Class RK1 Fuses Dimensions 0-60A 61-600A Fuse Catalog Number Ampere 250V 600V Rating 1 Pole 3 pole 1 pole 3 pole 0-30 20306R 20308R 60306R 60308R 31-60 20606R 20608R 60606R 60608R 61-100 21036R 21038R 61036R 61038R 101-200 22001R 22003R 62001R 62003R 201-400 24001R 24003R 64001R 64003R 401-600 2631R 2633R 6631R 6633R A variety of pole configurations and termination provisions are available. Refer to the fuse block section of this catalog for details. AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm 250V-A2K FUSES 0-30 2 51 9/16 14 - - - - - - 31-60 3 76 13/16 21 - - - - - - 61-100 5-7/8 149 1-1/16 27 1/8 3 3/4 19 1 25 101-200 7-1/8 181 1-9/16 40 3/16 5 1-1/8 28 1-3/8 35 201-400 8-5/8 219 2-1/16 53 1/4 6 1-5/8 41 1-7/8 48 401-600 10-3/8 264 2-9/16 66 1/4 6 2 51 2-1/4 57 600V-A6K FUSES 0-30 5 127 13/16 21 - - - - - - 31-60 5-1/2 139 1-1/16 27 - - - - - - 61-100 7-7/8 200 1-5/16 34 1/8 3 3/4 19 1 25 101-200 9-5/8 244 1-13/16 46 3/16 5 1-1/8 28 1-3/8 35 201-400 11-5/8 295 2-9/16 66 1/4 6 1-5/8 41 1-7/8 48 401-600 13-3/8 340 3-1/8 80 1/4 6 2 51 2-1/4 57 28

FAST ACTING/CLASS RK1 FUSES A2K & A6K A2K30 to 600 Melting Time Current Data, 250V Fuses Current in Amperes Time in Seconds Peak Let-Thru Current Data A2K30 to 600, 250 Volts AC Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes 29

FAST ACTING/CLASS RK1 FUSES A2K & A6K A6K30 to 600 Current in Amperes Time in Seconds Maximum Instantaneous Peak Let-Thru Amperes Melting Time Current Data, 600V Fuses Peak Let-Thru Current Data A6K30 to 600, 600 Volts AC Available Current in RMS Symmetrical Amperes 30

HSRK high speed/class rk1 High speed rk1 (HSRK) Protect your electrical power wiring and power semiconductors with a single fuse. The new HIGH SPEED RK1 (HSRK) combines semiconductor fuse performance with NEC branch circuit compliance. The fuse was designed with two specific applications in mind: 1. To provide semiconductor fuse performance to solid state drive applications but in the larger RK body sizes that have been typically installed in older systems. 2. To provide industrial power applications with the most current limiting fuse available, which in turn provides the best arc flash mitigation available to power systems using the larger RK size fuses. Highlights: Current Limiting Low I 2 t Drive protection in larger RK body sizes for older installations Fast acting Applications: ranch circuits AC drives Solid state controllers Feeder circuits Arc flash mitigation Features/enefits Most current limiting RK1 available Provides the best Arc flash mitigation for feeder and branch circuits (non motor load circuits) Excellent cycling ability for frequent drive starts and stops without nuisance opening Extremely Low I 2 t Ratings AC: (70 to 600A) 600VAC, 200KA I.R. 300KA I.R. Self certified Approvals HSRK (70 to 600A) UL listed to 248-12 File E2137 CSA certified to C22.2 - No. 248.12 31

Amp-trap HIGH SPEED/CLASS RK1 HSRK Standard Fuse Ampere Ratings, Catalog Numbers Ampere Catalog # Ampere Catalog # Rating 600V Rating 600V 70 HSRK70R 200 HSRK200R 80 HSRK80R 225 HSRK225R 90 HSRK90R 250 HSRK250R 100 HSRK100R 300 HSRK300R 110 HSRK110R 350 HSRK350R 125 HSRK125R 400 HSRK400R 150 HSRK150R 450 HSRK450R 175 HSRK175R 500 HSRK500R 600 HSRK600R Recommended Fuse locks With ox Connectors For Amp-trap Class RK1 Fuses Fuse Ampere Catalog Number 600V Rating 1 pole 3 pole 61-100 61036R 61038R 101-200 62001R 62003R 201-400 64001R 64003R 401-600 6631R 6633R A variety of pole configurations and termination provisions are available. Refer to the fuse block section of this catalog for details. 70-600A Dimensions AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm 600V-HSRK FUSES 61-100 7-7/8 200 1-5/16 34 1/8 3 3/4 19 1 25 101-200 9-5/8 244 1-13/16 46 3/16 5 1-1/8 28 1-3/8 35 201-400 11-5/8 295 2-9/16 66 1/4 6 1-5/8 41 1-7/8 48 401-600 13-3/8 340 3-1/8 80 1/4 6 2 51 2-1/4 57 32

Amp-trap HIGH SPEED/CLASS RK1 HSRK I 2 t Data HSRK (Amp Rating)R Ampere Rating (A) Pre-arc (A 2 s X 10 3 ) Max Clearing I 2 t @ 600V AC (A 2 s X 10 3 ) 70 1.2 14 80 1.6 17 90 2.3 24 100 2.7 26 110 2.3 23 125 3.4 32 150 5.1 45 175 8.0 65 200 14 100 225 14 110 250 16 130 300 26 200 350 37 290 400 63 450 450 67 500 500 98 600 600 141 900 I 2 t vs Working Voltage Watts Loss vs % Rated Current Correction Factor for l 2 t Correction Factor for Watts Loss Working Voltage (AC RMS Volts) % Rated Current 33

Amp-trap HIGH SPEED/CLASS RK1 HSRK Watts Loss Data HSRK70 600R, 600V AC Peak Let-Thru Data HSRK70 600R, 600V AC Ampere Rating (A) Watts Loss at Rated Current 70 10 80 11 90 13 100 14 110 18 125 19 150 25 175 26 200 27 225 35 250 43 300 45 350 47 400 53 450 62 500 63 600 83 Maximum Peak Let-Thru Current (A) 60Hz RMS Symmetrcal Prosective Current (A) Melting Time Current Data HSRK70 600R, 600V AC Prearcing Time(s) Prearcing Time(s) Prearc Current (A RMS)±8% Prearc Current (A RMS)±8% 34

AG class G amp-trap ag fuses fit right in to a wide variety of industrial applications The Ferraz Shawmut Amp-trap AG fuse series is a complete line of Class G fuses. AG fuses safely fit a wide variety of applications. Class G fuses are made in four physical sizes and provide good branch-circuit protection for lighting, heating, and appliance circuits. Features/enefits Four unique sizes from ½-60 amperes do not allow inter-changeability with other fuse classes Fiberglass bodies provide dimensional stability in harsh industrial settings HIGHLIGHTS: Applications: Ratings Approvals Current-Limiting Time Delay (above 5A) Lighting Heating* Appliances ranch Circuits AC: 1/2 to 20A 600VAC, 100K A I.R. 25 to 60A, 480VAC, 100k A I.R. UL Listed to Standard 248-5 File E2137 CSA Certified to Standard C22.2 No. 248.5 * Except in Canada, where fuses must be P or D type. Dimensions Standard Fuse Ampere Ratings, Catalog Numbers AMPERE CATALOG AMPERE CATALOG RATING NUMER RATING NUMER 1/2 AG1/2 15 AG15 1 AG1 20 AG20 1-1/2 AG1-1/2 25 AG25 2 AG2 30 AG30 3 AG3 35 AG35 AMPERE A C RATING In. mm In. mm In. mm 1/2-15A 1.31 33.3.406 10.3.28 7.1 20A 1.41 35.8.406 10.3.28 7.1 25, 30A 1.62 41.2.406 10.3.28 7.1 35-60A 2.25 57.2.406 10.3.50 12.7 Cross Reference: AG will replace the following fuses: ussmann SC, Littelfuse SLC 4 AG4 40 AG40 5 AG5 45 AG45 6 AG6 50 AG50 8 AG8 60 AG60 10 AG10 35

Time Delay/Class g Fuses ag AG1 to 10 Current in Amperes Time in Seconds Current in Amperes Melting Time Current Data, 480V Fuses AG15 to 60 Melting Time Current Data, 480V Fuses Time in Seconds Maximum Instantaneous Peak Let-Thru Amperes Peak Let-Thru Current Data AG1 to 60, 480 Volts AC Available Current in RMS Symmetrical Amperes 36

ATMR class CC SMALL FUSE - IG PROTECTION FOR GENERAL CIRCUITS Amp-trap ATMR fuses, in the Class CC family, are the smallest dimension 600VAC/DC fuses suitable for branch circuit protection. The ATMR is a popular choice for economical protection of control circuits and control circuit transformers where available short circuit currents exceed 10,000 amperes. ATMR s rejection dimensions prevent substitution by lesser rated fuses. These fast acting fuses give current limiting protection to general circuits. Features/enefits Rejection style design prevents replacement errors when used with recommended fuse blocks Versatile design for individual component and branch circuit protection HIGHLIGHTS: Applications: Ratings Approvals Fast Acting Very Current-Limiting Control Circuits Lighting General Loads ranch Circuit Protection AC: 1/10 to 30A 600VAC, 200kA I.R. DC: 1/10 to 30A 600VDC, 100kA I.R. UL Listed to Standard 248-4 File E2137 CSA Certified to Standard C22.2 No. 248.4 DC Listed to ULStandard 248 Standard Fuse Ampere Ratings, Catalog Numbers AMPERE CATALOG AMPERE CATALOG RATING NUMER RATING NUMER 1/10 ATMR1/10 3-1/2 ATMR3-1/2 1/8 ATMR1/8 4 ATMR4 2/10 ATMR2/10 5 ATMR5 1/4 ATMR1/4 6 ATMR6 3/10 ATMR3/10 7 ATMR7 1/2 ATMR1/2 8 ATMR8 3/4 ATMR3/4 9 ATMR9 1 ATMR1 10 ATMR10 1-1/4 ATMR1-1/4 12 ATMR12 1-1/2 ATMR-1-1/2 15 ATMR15 2 ATMR2 20 ATMR20 2-1/2 ATMR2-1/2 25 ATMR25 3 ATMR3 30 ATMR30 37

FAST ACTING/Class CC Fuses atmr Dimensions Recommended Fuse locks For Amp-Trap Class CC Fuses CATALOG NUMER ULTRASAFE Screw Connector Pressure Plate Number of Indicating with Double Connector Copper ox Poles Fuse Holders Quick Connects with Double Connector Quick Connects ADDER 30310R 30320R 30350R 1 USCC1I 30311R 30321R 30351R 2 USCC2I 30312R 30322R 30352R 3 USCC3I 30313R 30323R 30353R 3 USFMCCI Refer to the Class CC Fuse lock section of this catalog for other details. ATMR1/10 to 30 Melting Time Current Data, 600V Fuses Current in Amperes Time in Seconds Maximum Instantaneous Peak Let-Thru Amperes Peak Let-Thru Current Data ATMR3/4 to 30, 600 Volts AC Current in Amperes 38

ONE-TIME OT/OTN/OTS class K-5 for versatility and economy, these general purpose fuses are hard to beat OT, OTN and OTS general purpose fuses provide low cost protection for feeder and branch circuits serving lighting, heating, and other non-motor loads. OT, OTN and OTS fuses will safely interrupt available short circuit currents up to 50,000 amperes in all ratings. OT, OTN and OTS fuses are not rejection fuses care should be taken to ensure that replacement fuses do not have lower interrupting ratings than original fuses. OTN 15 through 60 satisfy the Canadian electrical code requirement for Type P, low melting-point, non-time delay fuses. Features/enefits Easy to read imprint label for quick recognition and replacement Low cost for high protection value HIGHLIGHTS: Applications: Ratings Approvals Versatile Lowest cost protection for circuits serving non-inductive loads Feeders ranch Circuits Resistive Heating Residential and Small Commercial Installations OT AC: 1 to 600A 250VAC, 50kA I.R. DC: 1 to 600A 250VDC, 20kA I.R. OTN (Canada) AC: 15 to 60A 250VAC, 50kA I.R. OTS AC: 1 to 600A 600VAC, 50kA I.R. DC: 1 to 600A 300VDC, 20kA I.R. UL Listed to Standard 248-9 File E2137 CSA Certified to Standard C22.2 No. 248.9* Ferraz Shawmut Certified for DC per UL248 *The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design use OTN 15-60. 39

ONE-TIME general purpose/class K-5 Fuses ot/otn/ots Standard Fuse Ampere Ratings, Catalog Numbers Ampere Catalog Number Ampere Catalog Number Ampere Catalog Number Rating 250V 600V Rating 250V 600V Rating 250V 600V 1 OT1 OTS1 30 OT30, OTN30* OTS30 125 OT125 OTS125 2 OT2 OTS2 35 OT35, OTN35* OTS35 150 OT150 OTS150 3 OT3 OTS3 40 OT40, OTN40* OTS40 175 OT175 OTS175 4 OT4 OTS4 45 OT45, OTN45* OTS45 200 OT200 OTS200 5 OT5 OTS5 50 OT50, OTN 50* OTS50 225 OT225 OTS225 6 OT6 OTS6 60 OT60, OTN60* OTS60 250 OT250 OTS250 7 OT7 65 OT65 300 OT300 OTS300 8 OT8 OTS8 70 OT70 OTS70 350 OT350 OTS350 10 OT10 OTS10 75 OT75 OTS75 400 OT400 OTS400 12 OT12 OTS12 80 OT80 OTS80 450 OT450 OTS450 15 OT15, OTN15* OTS15 90 OT90 OTS90 500 OT500 OTS500 20 OT20, OTN20* OTS20 100 OT100 OTS100 600 OT600 0TS600 25 OT25, OTN 25* OTS25 110 OT110 OTS110 * In Canada Recommended Fuse locks With ox Connectors For One-Time Class K-5 Fuses Dimensions 0-60A 61-600A Fuse Catalog Number Ampere 250V 600V Rating 1 Pole 3 pole 1 pole 3 pole 0-30 20306 20308 60306 60308 31-60 20606 20608 60606 60608 61-100 21036 21038 61036 61038 101-200 22001 22003 62001 62003 201-400 24001 24003 64001 64003 401-600 2631 2633 6631 6633 A variety of pole configurations and termination provisions are available. Refer to the fuse block section of this catalog for details. AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm 250V-OT, OTN FUSES 0-30 2 51 9/16 14 - - - - - - 31-60 3 76 13/16 21 - - - - - - 61-100 5-7/8 149 1-1/16 27 1/8 3 3/4 19 1 25 101-200 7-1/8 181 1-9/16 40 3/16 5 1-1/8 28 1-3/8 35 201-400 8-5/8 219 2-1/16 53 1/4 6 1-5/8 41 1-7/8 48 401-600 10-3/8 264 2-9/16 66 1/4 6 2 51 2-1/4 57 600V-OTS FUSES 0-30 5 127 13/16 21 - - - - - - 31-60 5-1/2 139 1-1/16 27 - - - - - - 61-100 7-7/8 200 1-5/16 34 1/8 3 3/4 19 1 25 101-200 9-5/8 244 1-13/16 46 3/16 5 1-1/8 28 1-3/8 35 201-400 11-5/8 295 2-9/16 66 1/4 6 1-5/8 41 1-7/8 48 401-600 13-3/8 340 3-1/8 80 1/4 6 2 51 2-1/4 57 40

ONE-TIME general purpose/class K-5 Fuses ot/otn/ots OT30 to 600; OTN 30, 60 Melting Time Current Data, 250V Fuses Current in Amperes Time in Seconds OTS30 to 600 Melting Time Current Data, 600V Fuses Peak Let-Thru Current Data OT, OTN & OTS30 to 600, 250 and 600 Volts AC Maximum Instantaneous Peak Let-Thru Amperes Time in Seconds Current in Amperes Available Current in RMS Symmetrical Amperes 41

RENEWALE RF/RFS & RL/RLS class H traditional protection for circuits with less than 10,000a SHORT CIRCUIT CURRENT RF and RFS general purpose fuses are suitable for application where available short circuit currents do not exceed 10,000 amperes. RF and RFS renewable fuses use matched RL and RLS die-cut zinc links from 1 to 600 amperes in 32 ratings. Features/enefits Knurled bushings for ease of disassembly Rugged construction for maximum service life Precision die-cut renewal links renew quickly and give repeatable performance HIGHLIGHTS: Applications: Ratings Approvals Renewable 32 Renewal Link Ratings General purpose loads where short circuits are 10,000 amperes or less RF AC: 1 to 600A 250VAC, 10kA I.R. RFS AC: 1 to 600A 600VAC, 10kA I.R. UL Listed to Standard 248-7 File E2137 CSA Certified to Standard C22.2 No. 248.7 42

RENEWALE Class h Fuses/links RF/rfS & rl/rls Standard Fuse Ampere Ratings, Catalog Numbers Ampere Catalog Number Ampere Catalog Number Ampere Catalog Number Rating 250V 600V Rating 250V 600V Rating 250V 600V 1 RF1/RL1 RFS1/RLS1 45 RF45/RL45 RFS45/RLS45 225 RF225/RL225 RFS225/RLS225 2 RF2/RL2 RFS2/RLS2 50 RF50/RL50 RFS50/RLS50 250 RF250/RL250 RFS250/RLS250 3 RF3/RL3 RFS3/RLS3 60 RF60/RL60 RFS60/RLS60 300 RF300/RL300 RFS300/RLS300 5 RF5/RL5 RFS5/RLS5 70 RF70/RL70 RFS70/RLS70 350 RF350/RL350 RFS350/RLS350 6 RF6/RL6 RFS6/RLS6 80 RF80/RL80 RFS80/RLS80 400 RF400/RL400 RFS400/RLS400 10 RF10/RL10 RFS10/RLS10 90 RF90/RL90 RFS90/RLS90 450 RF450/RL450 RFS450/RLS450 15 RF15/RL15 RFS15RLS15 100 RF100/RL100 RFS100/RLS100 500 RF500/RL500 RFS500/RLS500 20 RF20/RL20 RFS20/RLS20 110 RF110/RL110 RFS110/RLS110 600 RF600/RL600 RFS600/RLS600 25 RF25/RL25 RFS25/RLS25 125 RF125/RL125 RFS125/RLS125 30 RF30/RL30 RFS30/RLS30 150 RF150/RL150 RFS150/RLS150 35 RF35/RL35 RFS35/RLS35 175 RF175/RL175 RFS175/RLS175 40 RF40/RL40 RFS40/RLS40 200 RF200/RL200 RFS200/RLS200 Recommended Fuse locks With ox Connectors For Renewable Class H Fuses Fuse Catalog Number Ampere 250V 600V Rating 1 Pole 3 pole 1 pole 3 pole 0-30 20306 20308 60306 60308 31-60 20606 20608 60606 60608 61-100 21036 21038 61036 61038 101-200 22001 22003 62001 62003 201-400 24001 24003 64001 64003 401-600 2631 2633 6631 6633 0-60A A variety of pole configurations and termination provisions is available. Refer to the fuseholder section of this catalog for details. Dimensions 61-600A AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm 250V-RF FUSES 0-30 2 51 9/16 14 - - - - - - 31-60 3 76 13/16 21 - - - - - - 61-100 5-7/8 149 1-1/16 27 1/8 3 3/4 18 1 25 101-200 7-1/8 181 1-9/16 40 3/16 5 1-1/8 28 1-3/8 35 201-400 8-5/8 219 2-1/16 54 1/4 6 1-5/8 41 1-7/8 48 401-600 10-3/8 264 2-9/16 66 1/4 6 2 51 2-1/4 57 600V-RFS FUSES 0-30 5 127 13/16 21 - - - - - - 31-60 5-1/2 139 1-1/16 27 - - - - - - 61-100 7-7/8 200 1-5/16 34 1/8 3 3/4 18 1 25 101-200 9-5/8 244 1-13/16 46 3/16 5 1-1/8 28 1-3/8 35 201-400 11-5/8 295 2-9/16 67 1/4 6 1-5/8 41 1-7/8 48 401-600 13-3/8 340 3-1/8 80 1/4 6 2 51 2-1/4 57 43